Tender Value
₹16.6 L
EMD Value
₹16,600
Closing Date
16 Nov 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Electric (R&B) Division, Bhuj
Providing and Erecting Passanger Lift for Disabled Person in Mamlatdar and Sub Registrar Office at Muli, Taluka- Muli, Dist- Surenranagar. ( G+1 Floor)
357993
10/02 OF 2026/2027
Open
Electrical
Works
Kutch
7 documents required · 7 mandatory
₹900
EXECUTIVE ENGINEER ,ELECTRICAL(ROAD AND BUILDING) DIVISION,BHUJ
₹16,600
23 Oct 2026
23 Oct 2026
23 Oct 2026
16 Nov 2026
23 Oct 2026
120 days
Name of Work:- Providing and Erecting Passanger Lift for Disabled Person in
Mamlatdar and Sub Registrar Office at Muli, Taluka- Muli,
Dist- Surenranagar. ( G+1 Floor)
Rate at which the
materials will be
Sr. No. Quantity Particulars charged to the
Signature of the Contractor Deputy Executive Engineer
Electrical R&B Sub Division
Executive Engineer
Electrical R&B Division
Name of Work:- Providing and Erecting Passanger Lift for Disabled Person in Mamlatdar and Sub Registrar
Office at Muli, Taluka- Muli, Dist- Surenranagar. ( G+1 Floor)
Sr. Quantities Estimated Rate
No. estimated but
may be more or Total amount
may be more or Total amount
less Description of Item. according to
In Figures In Words estimate
1 1 Ea Supplying, Erecting, Testing & Commissioning the passenger lift 1588226.01 Rupees Fifteen
having following main features: Lakh(s) Eighty Eight
13 Passengers, Ground plus 1 upper floor with Rated Speed of Thousand Two
1.0 m/sec., Hundred Twenty Six
And Paise One Only
(C) With General PLUS ADDITIONAL SPECIAL FEATURES
attached herewith. Prem. Cat.
(A) GENERAL DESCRIPTION OF LIFTS.
[1] GEAR LESS LIFT DRIVE (MRL) comprising of High
Starting torque Lift 3 phase 440 V A. C. Permanent Magnet
Synchronous motor of proper rating with high efficiency shall be
[2] Micro processor based / PLC, ACVVVF, vector control drive
with encoder feedback closed loop system shall be used for lift car
and door operation which shall be full collective selective
operation hall call demand response, UP/DOWN hall stops, Main,
Up/ Down Contactor with overload and phase reversal relay and
safety controls.
[3] Car with M S platform with bracings of adequate size and to
sustain the impact load cabin + passenger with safety factor of fire
for steel and side panels of Stainless steel of sheet of grade
duty. Car ceiling will be S.S. finishes with aesthetic appearance
with LED ceiling lights. Car flooring shall be of anti skid PVC
with choice of colour of engineer in charge. Car doors shall be of
stainless steel grade 304, hairline finish with centre opening /
telescopic automatic doors. Car panel will also be S.S.
finished with emergency stop device, mechanical door safety
device, facility of auto/ attended mode. All car panel buttons and
all floor switches must be with brail language as per lift act.
[4] All landing doors must be fire rated for 2 hour shall be fully
automatic centre opening/ telescopic opening made of hairline
finish steel grade of 304 with key holes and infrared curtains with
Unlocking facility from outside
[5] Appropriate battery operated emergency light in the car along
with alarm switch shall be provided. Also, Emergency Light &
Fan should start immediately without any Time Delay as soon as
[6] Digital scrolling indicator system for up-down arrow along
with floor position indicator shall be provided inside the car and at
[7] Full height infra red curtain with multiple cross / crossing light
beams shall be provided.[8] Automatic Rescue Device (ARD)
shall be provided accordingly of passenger capacity with Manual
Rescue Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over loading
shall be provided such that doors kept open till excess load is
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with automatic sleep timer
shall be provided.
[12] Voice annunciator with suitable music shall be provided in lift
[13] Self diagnostics system for operational and safety parameters
shall be provided in control panel.
[14] Mechanical over speed governor with governor calibration as
per actual site parameters and submission of calibration certificate
submission, door key holes in the floor doors, fireman switch shall
[15] Lift machine hoisting arrangement in the lift machine room
and monkey ladder for lift pit should be provided by the lift
agency, along with the other steel structure works, foundations for
the machine etc…
[16] In the hoist way fascia plate shall be provided without any
extra cost, where ever required as / if directed by engineer in
[17] Permanent wiring with necessary safety devices like RCCB in
all circuit, Over Voltage Under Voltage protection and THD
eliminator in circuit for lift machine room and lift well with proper
numbers of light points, with fixtures, exhaust fan and plug points
shall be provided by the agency. Only 3 phase Power Supply shall
be made available by department in lift machine room. Necessary
Earthing as per Lift Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and alteration in lift
shaft and machine room related to erection of lift shall be made by
lift agency without any extra cost. (granite/marble fixing around all
landing door openings are not in lift agency’s scope.)
[19] Agency has to provide all working drawings and documents
and liaison services for obtaining all necessary permission from lift
inspector and other authorities. [20] acrylic transparent
licence/display A4 size holder in lift car
[20A] As per statutory requirement of Govt. Of Gujarat lift &
escalator act 2000, lift agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after lift erection
and provide report by third party authorized by concern licensing
authority 5.agency has to provide third party insurance upto
completion of free maintenance period and submit the document
[21] Car Panel Operating Buttons with floor position
indicator/buttons must be of Auto Glow type clearly visible when
view from inside cabin.
[22] For Physically Handicapped person Full Length Handrails of
hairline finish steel grade of 304 should be provided at appropriate
height on the Rear & Side Wall Panels in Lift Car.
(B) SPECIAL FEATURES DESCRIPTION OF LIFTS for
PREMIUM category
1. Advanced control system dual 64 bit embedded microprocessor
with CANBUS Serial Communication mode including
Regenerative power efficient operation,on site programming
facility, Anti nuisance, Pte-opening, BMS/RMS with necessary
online real time monitoring system having necessary connectivity
for remote monitoring & other suitable supporting hardware &
software devices to fulfil the purpose.
2. Floor Indication LCD Display with call registration & brail
mark with arrival gong and hall lantern & TFT Screen in the car
with MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive SS Moonrock finish /
Hair Line / Honeycomb for car and all Doors, All landing doors
must have fire rating up to 2 hours and car door must have multi-
level crisscross beam door protection.
4. To & fro communication system & wiring (i.e. car , control
room & guard room ) and Each elevator are equipped with remote
monitoring system.agency has to provide mobile app and user id
and password for monitoring
2 55 Ea Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable 676.70 Rupees Six Hundred
multistrand Copper conductor for 1.1 KV. to be laid on wall Seventy Six And
with necessary clamps or in existing trench / pipe at road Paise Seventy Only
crossing or floor of following size of cables.
(A) 4 core 10 Sq. mm
3 2 Ea Providing & erecting 415 V MCB Four Pole for Motor & 668.62 Rupees Six Hundred
Inductive Load (C Curve) having 10KA breaking capacity & Sixty Eight And
confirms to IS :8828 in existing box having following capacity Paise Sixty Two
(b)40 Amp. Cat.III Only
4 2 Ea Plastic enclosure fitted with DIN rail suitable for incorporating 108.07 Rupees One
Three /Four nos. MCB Hundred Eight And
Paise Seven Only
5 30 Kg Providing and erecting required size Copper strip for earthing of 794.87 Rupees Seven
H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using Hundred Ninety
copper clamp. Four And Paise
Eighty Seven Only
6 2 Ea Supplying & erecting earth pit of minimum bore dia.150mm size 4591.46 Rupees Four
approved make Earthing Electrode consisting Pipe-in-Pipe Thousand Five
Technology as per IS 3043-1987 made of corrosion free hot Hundred Ninety One
dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200 And Paise Forty Six
Micron galvanising, Inner pipe dia of 25 mm having 200-250
Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive compound
with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover. (A)(approved
make OEM has to submit test certificate including value of earth
resistance of installation duly stamped and signed by agency and
officer Incharge has to ensure the value of earthing resistane
mentioned in test Certificate) & having back filling compound of
(B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm /
meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at
no load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to retain
moisture for long time Necessary test report must be submitted by
(a) For Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
In Words : Rupees Sixteen Lakh(s) Sixty Thousand Twenty Six And Paise Ninety One Only
I/We am/are willing to carry out the work at ____________% above/below (in Figures)__________________________ percent Above /
below (in words) the estimated rates mentioned above amount of my\our tender works out as under :-
Estimated amount put to Tender Rs._________________
Deduct _____% below Rs._________________
(-)Less For Dismantle Material Rs._________________
Net Amount Rs._________________
Estimated amount put to Tender Rs. _________________
(-)Less For Dismantle Material Rs. _______________
Net Amount Rs. _________________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local situation regarding
material,labour and other factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications and other tender documents of
this work and agree to execute the same accordingly.
(Signature of the Contractor) Deputy Executive Engineer
Electrical R&B Sub Division
Executive Engineer
Electrical R&B Division
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be considered as final.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
lift amc New GR 2026.pdf
notice no 10.pdf
sbd muli.pdf
special conditions.pdf
SCH A and B.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .