Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹30.2 L+₹2.7 L (10.0%)Rejected-Finance 121004 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹32.1 L+₹4.6 L (16.8%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | Rejected-Technical PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | - | Rejected-Technical Not enlisted in appropriate category | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
24 Oct 2020, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2020_MES_380910_1
GE MAINT EZHIMALA 8345
Open Tender
Electrical Maintenance Service
Item Rate
332 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE MAINT EZHIMALA
₹70,000
Yes
19 Nov 2020
28 Sept 2020
26 Oct 2020
28 Sept 2020
24 Oct 2020
12 Oct 2020
28 Sept 2020 - 8 Oct 2020
Amount
Note applicable for all Items of BOQ:- (FOR SPECIAL ATTENTION OF BIDDERS) If the lowest quoted amount is less than the estimated cost of the work mentioned in NIT, the lowest bidder will have to submit FDR/BGB in favour of Accepting Officer within 7 (Seven) days of opening of Financial Bid for the difference in estimated cost and quoted amount. In case the said FDR/BGB is not submitted within stipulated period as mentioned above, the contractor shall be banned for 6 months and his bid will be rejected. FDR/GBG will be released only after completion of entire work and production of proof for the payment of wages to all the workers employed under the contract is paid not less than the minimum wages notified by the Central Govt./State Govt. whichever is more
Outsourcing services for Operation of 11 KV Substation NO 1 comprising of HT/LT switch gears, HT/LT Machineries and all connected accessories mentioned below round the clock including Sundays and holidays by employing two skilled ITI qualified electrician per each shift (0600hrs to 1400 hrs, 1400 hrs to 2200 hrs and 2200 hrs to 0600 hrs ) and to carry out the following routine works as directed by Engineer- In- Charge. The Equipment's details are:- (a) 11 KV 400 amps Vacuum circuit breaker with relays and controls - 07 nos. (b) 11KV/433 V step down transformer of capacity 100 KVA - 01 No. (c) LT control panel - 01 No. (d) 11 KV Metering panel - 01 No (e) Battery bank with Battery charger - 01 no . (f) HT Bus coupler with Ring main supply system - 01 Set (g) DG Det 01 Nos
Outsourcing services for Operation of 11 KV Substation NO 4 comprising of HT/LT switch gears, HT/LT Machineries and all connected accessories mentioned below round the clock including Sundays and holidays by employing one skilled ITI qualified electrician per shifts (0600hrs to 1400 hrs, 1400 hrs to 2200 hrs and 2200 hrs to 0600 hrs) and to carry out the following routine works as directed by Engineer- In- Charge. The Equipment details are :- (a) 11 KV 400 amps Vacuum circuit breaker with relays and control- 04 Nos. (b) 11 KV OSFU 400 Amps- 03 Nos. (c) 11KV/433 V step down transformer of capacity 315 KVA- 02 No. (d) LT control panel - 01 No. (e) PF Improvement Capacitor panel - 01 No. (f) Battery bank with Battery charger- 01 No.
Outsourcing services for Operation of 11 KV Substation NO 9 comprising of HT/LT switch gears, HT/LT Machineries and all connected accessories mentioned below round the clock including Sundays and holidays by employing two skilled ITI qualified electrician per shifts ( 0600hrs to 1400 hrs, 1400 hrs to 2200 hrs and 2200 hrs to 0600 hrs ) and to carry out the following routine works as directed by Engr- In- Charge. The equipment details are :- (a) 11 KV 400 amps Vacuum circuit breaker with relays and control- 11 Nos. (b) 11KV/433 V stepdown transformer of capacity 500 KVA- 01 No. (c) 11KV/433 V stepdown transformer of capacity 1000 KVA- 02 Nos. (d) LT control panel - 03 Nos. (e) PF Improvement Capacitor panel - 01 No. (f) Battery bank with Battery charger- 01 No. (g) HT Bus coupler with Ring Main - 01 No. (h) DG Set 320 KVA- 01 No. (j) DG set panel - 01 No .
NOTES FOR SL ITEM NO 02, 03 & 04 (i) Spares if any required for replacement shall be supplied by MES (ii) The tradesmen shall be well qualified in respective trade and shall wear approved uniform as directed by Engineer- in- charge while on duty. He shall be well conversant with preventive measures (First Aid) in case of electrical accidents and fire fighting systems and maintain log books for Sub Stations (iii) The Unit rate quoted shall include stationery required to maintain attendance register, duty roster, payment register, display board, complaint register, Log sheet and other register as directed by Engineer- in-Charge. The unit rate also include distilled water, grease etc for battery maintenanance ,cleaning materials like cotton waste etc. (iv) The contractor will prepare duty roster well in advance and got it approved by Engineer - In- Charge and one copy of the roster shall be displayed in the notice board . (v) Supplying of stationary, uniform, tool and plant required for day to day maintenance for sub Station maintenance all as directed by Engineer in charge. (vi) Contractor is fully responsible for cleanliness of the area of substations.
Neptune Engineers and Builders
S. M. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .