Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹25.1 L+₹58,330 (2.38%)Rejected-Finance 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹26.8 L+₹2.3 L (9.43%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹27.9 L+₹3.4 L (13.8%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹28.5 L+₹4.0 L (16.3%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L5 | Rejected-Finance Higher bid value |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
4 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2020_MES_360064_1
GE MAINT EZHIMALA 8314
Open Tender
Electrical Maintenance Service
Item Rate
180 days
GE(MAINT)EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE MAINT EZHIMALA
₹70,000
Yes
20 Aug 2020
10 Jul 2020
6 Aug 2020
10 Jul 2020
4 Aug 2020
23 Jul 2020
10 Jul 2020 - 20 Jul 2020
60 days
Amount
Taking down old unserviceable overhead ACSR conductor of any type complete as specified and directed by EIC
Taking down old unserviceable GI earth wire of any type from distribution span complete as specified and directed by EIC
Taking down old unserviceable MS channel,cross arm, clamp, and all accessoties complete as specified and directed by EIC
Taking down old unserviceable insulator of any size complete as specified and directed by EIC
Taking down the unserviceable LT UG cable of size of 95 to 300 sqmm 3.5 core/04 core including removing electrical connection and keeping side serviceable cable include removing cable protection cover etc all as specified.
-ditto- all as per Item No 5.00 above but size up to 70 sqmm complete as specified.
Excavation in trenches not exceeding 1.5 metre in width and depth and getting out in hard and dense soil complete as specified and as directed. Note: excavation has to be done manually only
Returning and filling in including levelling watering and well ramming into layers not exceeding 25 cm in hard/dense soil
Removal of excavated soil to a distance not exceeding 50 metres and depositing at a level not exceeding 1.5 metre from starting point.
Supply and spreading crushed stone sand for cushioning and covering of the UG cable in trenches complete as specified and directed.
Supply and lay PCC un reinforced cable cover of size 250 mmx150mmx40mm , class LV type I flat for cable protection complete as specified and directed.
Relaying of PCC un reinforced LT cable cover of size 250 mmx150mmx40mm item obtained from Item Nos.5.00 & 6.00 complete as specified and directed by EIC.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs, glands XLPE insulated heavy duly galvanised steel strip armoured LT1100 volt grade with aluminium conductors of size 150 sqmm 3.5 core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.13.00 above but size of 120 sqmm 3.5core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.13.00 above but size of 95 sqmm 3.5core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.13.00 above but size of 70 sqmm 3.5core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.13.00 above but size of 50 sqmm 3.5 core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.13.00 above but size of 35 sqmm 3.5 core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.13.00 above but size of 25 sqmm 3.5 core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.13.00 but size of 16 sqmm 4.0 core complete as specified and directed Make Havells, RPG, Polycab.
-ditto- all as per Item No.13.00 above but size of 10 sqmm 4.0core complete as specified and directed Make Havells, RPG, Polycab.
Relaying cable obtained from taking out in trench/fixing to walls/pipe/pole with proper saddles XLPE insulated heavy duly galvanised steel strip armoured LT cable size up to 70 sqmm sqmm 3/3.5/4 core complete as specified and directed
-ditto- all as per Item No.18.00 above but cable size 95 to 300 sqmm 3.5 core
Cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.30 metre and depth 0.6 metre all as directed and making good the road/hard using pre mix bituminous mixture materials as required at site to match with the existing surface all as specified. NOTE: Before using the hand drilling/ breaker machine diamond cutter will be used all as directed by EIC
Supply and fix in replacement of GI tubing light grade 50 mm nominal dia in trench/road/pole for cable protection complete as specified and directed. Make Surya, Jindal
-ditto- all as per Item No.25.00 above but size of 80 mm nominal dia
Supply ang Jointing LT straight through joint 1100 volt , size up to 35 Sqmm 3.5/4 core complete as specified and directed
Supply ang Jointing LT straight through joint 1100 volt , size 50 Sqmm to 95 Sqmm 3.5/4 core complete as specified and directed
Supply ang Jointing LT straight through joint 1100 volt , size 120 Sqmm to 300Sqmm 3.5/4 core complete as specified and directed
Supply and fix in replacement of MCB 63 Amps TPN 240/415 Volts, 'C' curve Make : Havells/L&T /Legrand
Supply and fix in replacement of MCCB up to100 Amp 16 KA /415volt rating/415volt TPN fixed thermal rating. Make:- L&T/ABB/ Havells.
Supply and fix in replacement of MCCB 125 Amp 25 KA /415volt rating four pole fixed thermal rating. Make L&T/ABB/ Havells.
Supply and fix in replacement of MCCB 250 Amp 25 KA/415volt rating four pole fixed thermal rating. Make L&T/ABB/ Havells.
Supply and fix in replacement of MCCB 400Amp 36 KA/415volt rating four pole fixed thermal rating. Make L&T/ABB/ Havells.
Supply and fix in replacement of MCCB 630Amp 36 KA rating TPN fixed thermal rating. Make L&T/ABB/ Havells.
S&F in replacement of Industrial switchgear Busbar chamber 6 way 400 Amps of size 60 x 45 x 30cm outdoor type made with 3mm thick MS sheet powder coated with necessary canopy and fixed on 25x25x6mm angle iron frame with required PCC foundation all as directed.
-ditto- all as per Item No.36.00 but of capacity 630 Amps
S&F in replacement of LT feeder pillar box made out of 3mm thick MS sheet outdoor type powder coated of size 45x45x30cm with 250A rated aluminium busbar 6 way with necessary canopy and fixed on 25x25x6mm angle iron frame with required PCC foundation including MCCB 4 pole 160 A 16 kA as incomer and MCB TPN 63 A - 6 Nos as outgoing complete as specified and as directed.
ROTECH ENGINEERS AND BUILDERS
G P ENGINEERS
pk janardhanan
ANAND REFRIGERATION
devan enterprises
KDR CONSTRUCTION
R.K. Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .