Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹28.9 LAccepted-AOC | 1 | Accepted-AOC AOC | |
| 2 | 2₹30.5 L+₹1.6 L (5.47%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | 2 | Rejected-Finance NOT L1 | |
| 3 | 3₹31.0 L+₹2.1 L (7.16%)Rejected-Finance | 3 | Rejected-Finance NOT L1 | |
| 4 | 4₹31.4 L+₹2.5 L (8.48%)Rejected-Finance PLOT NO 44 SIDDARTH PARK BEHIND ICE FACTORY KODKI ROAD BHUJ PIN 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | 4 | Rejected-Finance NOT L1 | |
| 5 | 5₹31.8 L+₹2.9 L (10.0%)Rejected-Finance | 5 | Rejected-Finance NOT L1 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
5 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY BHUJ
GE ARMY BHUJ
SPECIAL REPIRES AND PROVN OF CERTAIN E M MINOR WORKS AT BHUJ AND GANDHIDHAM UNDER GE ARMY BHUJ
2022_MES_505402_1
8884
Open Tender
Civil Works
Item Rate
120 days
ARMY AREA GANDHDHAM AND BHUJ
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY BHUJ
₹56,000
Yes
8 Apr 2022
3 Feb 2022
7 Mar 2022
3 Feb 2022
5 Mar 2022
18 Feb 2022
60 days
Amount
Supply and fixing ceiling fans complete with blades, down rods, remote with accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) with external driver and making necessary connetion from ceiling fan to ceiling rose with PVC insulated FRLS 3 core 0.5 sqmm copper flexible conductor complete all as specified and directed by Engineer- in- charge.
Supply and fixing LED street light fitting of capacity 35 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver with impact and corrosion resistant including all fixing accessories complete with IP 65 protection complete all as specified and directed by Engineer-in-charge.
M&L Prestressed concrete pole, 9.0 metres long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom,class 10 complete including providing 4 Nos of 30 cm wide bands with Black & yellow paint starting from plinth level and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete all as specified and directed by Engr-in-charge.
M&L Plain cement Concrete Type D-2 1:4:8 (using 40 mm graded aggregate) in foundations, filling and mass etc complete all as specified .
M&L plain cement concrete type B-1 1:2:4 mix (using 20 mm graded stone agg) as in coping, parapets , bed plates, kerb and the like rounded or chamfered on edges complete all as specified and directed.
M&L of Earthing complete with galvanized steel earth plate electrode 60 x60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to GI earth lead 4 Sqmm dia by means of bolts nuts, check nut and washers of GI and GI tubing 40 mm bore, light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) typeC 1 pre cast RCC (1:2:4) type B1 cover slab 450 x 450 x 50 mm with one handle for lifting made out of 8 mm dia MS bar, wire mash, 20 mm bore GI tubing for watering ,charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed Electrical plate no 3 of SSR Part-I comlete all as specified.
M&L Supply, lay, jointing and testing XPLE insulated LT under ground cable, 1100 volts grade heavy duty, armoured with multi stranded aluminium conductor laid in trenches/ ducts, in pipes or on poles etc complete all as specified and as directed for the size 16 Sqmm 4 core.
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 mtr wide including getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including leveling spreading watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed .
Removing of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
M&L for spreading clean dry sand in cable trenches for cushioning of cable protection complete all as directed. Note :- Sand will be measured after punning.
Supplying and laying reinforced precast concrete cable cover, class LV, type 2 , size 300 mm x 180 mm x 40 mm laid flat in trenches for cable protection all as specified and directed.
S&F GI pipe 32 mm light grade with all fitting fixed to electric pole and laid in road crossing for cable protection with suitable size clamp, nut bolt and washers all as directed.
M&L for three core PVC insulated sheathed(heavy duty) unarmoured aluminium conductor cable (for phase and neutral) of size 1.5 Sqmm 3 Core for connection drawing through pole or GI brackets of street light fittings with junction box complete all as directed.
Supply and fix Weather Proof PVC Junction Box made of 2 mm thick of size 250x200x100 mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32 A - 01 No MCB SP 06 Amps 10 KA - 01 No incl 02 Nos Cable Glands suitable for inserting cable not less than 50 sqmm with 02 No 01 mm GI plate (150x50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to IP 65 complete including fixing on street light pole with MS Clamps, bolts, nuts and washers all as specified and directed by Engr-in-Charge.
Supply and fixing mounting bracket made out of medium grade GI tubing 32 mm bore 1.5 M long & bend to shape including 02 Nos MS Clamps, Nut Bolts, Washers etc all as directed by EIC.
Supply and fix Weather Proof PVC Junction Box made of 2 mm thick for mounting of digital type time switch 110-240V 1 C/O - 2 Mod in street light circuit to control the ON/OFF timing of street/parameter including power contactor 3 pole , 1NO+1NC of capacity 20 Amps confirming to IP 65 complete all as specified and directed by Engr-in-Charge.
S&F GI pipe 15 mm light grade with all fitting fixed to cable junction box to street light fitting for cable protection with suitable size clamp, nut bolt and washers all as directed.
M&L for Drilling vertically from average ground level for 300 mm dia pilot bore hole in any type of strata by mud flash rotary rig including cost of bentonite powder . Drilling shall be done by mud flash rotating equipment and bore shall be unsealed at least for requried hours to the entire depth of bore holes, depth of bore hole from 0 to 15 Meters depth including sub soil complete all as specified and directed
M&L, Drilling vertically from average ground level for 300 mm dia pilot bore hole in any type of strata by mud flash rotary rig and including cost of bentonite powder. Drilling shall be done by mud flash rotating equipment and bore shall be unsealed at least for 72 hours to the entire depth of bore holes, depth of bore hole from 0 to 15 Mtr depth including sub soil complete all as specified and directed with the following items :-(i) Depth of bore holes from 15 m to100 m depth.ote for serial No. 1& 2 :- (a) The pilot bore wells shall be drilled on tentative location as approved by GE. Tentative location which shall be obtained from Geological department of GWS&SB by the contractor. (b) If the yield is insufficient as considered by /GE then pilot bore shall be drilled at new place as directed by GE. Payment shall however be made only for drilling as per actual. (c) Rig, tools and plants etc required for completion of work and their cartage. (d) Collection of soil Strata at every 3m depth or change in strata met with during the bore shall be plotted against the depth on a tracing paper in the form of strata chart and blue print in sex truplicate shall be submitted to deptt for record. (e) Actual depth of final bore shall be decided based on the result of electro logging and TDS report. (f) Soil / strata testing report shall be done through Geo hydrology department for water aquifier details of the location if required and submitted to the Engr incharge
M&L for Electro logging test of the pilot bore hole by using logger equipment including all necessary arrangements for chemical analysis, bactriological test of sample of yield obtained from pilot bore to astertain potability of water all as specified and directed Note : The contractor shall submit electrologging result with recommended bore assembly details in duplicate for approval of GE.
M&L for Drilling (Reaming) pilot hole 300 mm dia in any type of soil/alluvial strata by rotary rig direct mud circulation method by using bentonite clay in prepared circulating mud to prevent caving in of borewell and developing bore into a full fledged bore hole of 400 mm dia including all equipment tools and plants shall be provided for completion of job at this own cost for a depth of 0 to 15 m including sub soil complete all as specified and directed.
All as per item No. 4 above but in sand/stone strata including clay packing for 300 mm dia to 400 mm dia bore hole from 15 m to 100 m depth.
Development and testing for yield including all necessary arrangements for testing and developing, including lowering and removing of 100 mm dia drop line and 32 mm dia air line for development of each water bearing zone come across upto the full depth of deep bore well of size 300 mm dia for complete period of development of bore, air compressor 600 CFM / 150 PSI running till sand free discharge obtained etc all as specified and directed by engr-in-Charge.
Supplying lowering, jointing, connecting and fixing following sizes of HDPE casing pipes into bore hole including providing suitable size of bore plug, HDPE pipe clamp, Nut bolts, bottom lowering plate, column pipe clamp, borewell cover made up of MS sheet 3 mm thick, split type and both side locking arrangement and making 3"/4" hole for insertion of column pipe in centre of the bore well including welding works and cover shall be suitable for 200 mm dia bore well etc complete all as specified and directed :- Note : The assembly of casing pipes shall be lowered as per electrogging test report and recommended assembly details.(a) 200 mm dia RCC blank pipe 25 mm thick
(b) 200 mm dia x 25 mm thick RCC strainer pipes with 75 Nos of 5 mm size holes per meter length
Supply and fix HDPE (High density polyethylene) pipe, PE-63 grade, ISI marked , as per IS 4984, PN 10, size 3inch, Outer dia 75 mm, 10 kg/cm2, suitable for bore wells including providing SS nipples (03 Nos) of suitable size flanged type complete all as specified and directed.
M&L for sanitary sealing of tube well with PCC (1:2:4) type B1 using 20mm graded stone aggregate upto a depth of 1 mtr from ground level and 0.45 mtr above ground level (Square type of ext dimensions 600 mm x 600 mm) around tube well casing, plat from of ext dimensions 1200 x 1200 x150mm at ground level with PCC 1:4:8 type D2 foundation using 40mm stone aggregate including necessary form work and supply and placing of 80mm bore light grade, GI pipe, at two places each 1.5m in length for pouring of peagravel (in future) and capping with screwed cap at top side end etc complete all as specified and directed.
M&L for strata sample (at every 3 meters depth) one set in suitable box pattern, earth sample strata should be produced as per IS and submitted to the department. The box shall be 2nd class hard wood with suitable locking arrangement etc complete all as specified and directed.
Supply and fix UPVC pipe Sch 80 grade, ISI marked , Outer dia 75 mm, 10 kg/cm2, suitable for bore wells including providing SS nipples (03 Nos) of suitable size flanged type complete all as specified and directed.
S&F polypropelene rope 28 mm dia, ISI marked, heavy duty grade complete.
Supply and fix PVC insulated and PVC sheathed multi stranded copper conductor cable for submersible pump set, ISI marked, conforming to IS-864 of size 3 core 6 Sqmm, 1100 volts grade, including necessary water proof connection to submersible pump at cable lead complete all as specified and directed.
Supply install, testing and commissioning multi stage S.S submersible pump, with S.S Bowl and connected with 90 mm dia column pipe by means of S.S flange and Connecting SS Nipple and 6 Sqmm copper conductor submersible cable having dilfuser casing construction and impellers dynamically balanced rotor and pump shaft with impeller with outlet size 80 mm and motor 5 HP suitable for operation on 3 phase 415 volts, S1 duty complete including lowering into borewell etc complete all as specified and directed.
Supply and fixing, connecting and testing of Non return valve flanged type complete as locking device with bolts, nuts, rubber gaskets etc including jointing materials of size 90 mm OD, complete all all as specified and directed
Supply and fixing of PVC air valve 25 mm dia bore with required length of PVC pipes, clamps etc complete all as specified and directed
Supply and fixing of well cap of 200 mm dia size pipe on pipe all as specified and complete with locking arrangement complete.
Supply and fixing of screwed MS bail plug of size 200 mm dia size 6 mm thick of 1 mtr long with MS rod 25 mm dia size welded to 200 mm from bottom bail hook complete all as specified and directed by Engr-In-Charge.
M/s Bombay Novelty Stores
Ashok Electric and Electronics
M/S S. SINGH TRADERS
machine vision plus
M/S PRADEEP ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .