Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.3 LAccepted-AOC | 1 | Accepted-AOC Awarded being L1 | |
| 2 | 2₹10.5 L+₹1.0 L (10.9%)Rejected-Finance | 2 | Rejected-Finance Rejected being other than L1 | |
| 3 | 3₹11.7 L+₹2.2 L (23.0%)Rejected-Finance | 3 | Rejected-Finance Rejected being other than L1 | |
| 4 | 4₹12.1 L+₹2.6 L (27.0%)Rejected-Finance DOOR NO 4 202 MASJID STREET EPURUPALEM CHIRALA 533166 | CHIRALA | 533166 | 4 | Rejected-Finance Rejected being other than L1 | |
| 5 | Rejected-Technical NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | - | Rejected-Technical Since b(i) category as per NIT not exist with bidder, to be rejected |
| Sl No | Description | Qty | Unit | K VENUGOPALA SWAMY L2 | BEST ENGINEERING L4 | PAVANI INFRAS L1 | K R ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | S&F in replacement of LT junction box outdoor, single door opening front side with caldron sliding locking arrangement suitable size make out of CRCA Sheet of 3.15 mm thick with powder coated painting, frame made out of flat iron 45 x 45 x 6 mm and four numbers of 100 Amps aluminum bars duly insulated on insulators / suitable size Bakelite sheet fixed horizontally including making necessary drilling on bus bars for fixing of out going cable upto 95 Sqmm XLPE - 05 Nos with minimum gap as per IE standards and one No MCCB of capacity 63 A, 4 Pole, 415 V 25 KA complete ( free space between MCCB / busbar and other connection items should be provided,) including removing of existing Jn box and excavation work and fixing arrangement on ground by using suitable type of PCC, nuts & bolts, danger notice sticker, cable glands, internal wiring with FRLS copper sires of suitable size complete all as specified and directed
Note for 1 & 8: Before placing the order the contractor should submit the Drg for approval of AGE(I) | 2 | Each | 45,000 ₹90,000 | 35,500 ₹71,000 Lowest | 37,000 ₹74,000 | 42,999 ₹85,998 |
| 2.00 | Supply, installation, commissioning and testing of LT Feeder Pillar Box out door, double door type made out of CRCA Sheet of 3.15 mm thick with powder coated painting frame suitable size for fixing the I/C & O/G MCCB mentioned below and four numbers of 150 Amps aluminum strips / bars duly insulated on insulators - 4 Nos / suitable size Bakelite sheet, free space between MCCBs / busbar and other connection items should be provided, the space between ground to panel should be 20 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement of tower bolt type, danger notice sticker, provn of cable entry and exit arrangement for Al cable size upto 120 Sqmm and glands, thimbling for connection of cable to MCCBs/bus bar etc and internal wiring with FRLS copper wires of suitable size and marking of each MCCB function with suitable size, removing old unsv panel letter and including the following complete all as specified and directed:-
(A) Main Incoming
(i) MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 100 Amps, 415 volts, 50 Hz, rupturing capacity 26 KA - 01 No.
(ii) Onload changeover 4 pole 100 Amp capacity - 01
(Open execution)
(iii) LED Multifunctional Panel meter to measure voltage, current frequency, power factor, kWH, etc with all connected CTs
(iv) LED indicating lamps with colour Red, Yellow, Blue (03 Lights) - 01 Set
(B) Main Outgoing
(i) MCCB conforming to IS:13947 (Part-II), IEC-947, TPN (4 pole), 63 Amps, 415 volts, 50 Hz, rupturing capacity 16 KA - 02 No.
(ii) MCB TPN 6-32 Amps, 10 kA, C Curve - 07 Nos | 1 | Each Job | 1,05,000 ₹1,05,000 Lowest | 1,20,000 ₹1,20,000 | 1,30,000 ₹1,30,000 | 1,59,999 ₹1,59,999 |
| 3.00 | Material & Labour for fixing of MCCB 415 V, 16 KA, 3 Pole 63 A including taking down old burn out MCCB and making necessary arrangement for fixing the new one like cutting, welding, screwing, connector (links) of suitable size to connect the MCCB with bus bar, thimble of suitable size, nuts & bolts, extended links etc complete required for fixing the new one in existing location complete all as specified and directed | 5 | Each | 5,000 ₹25,000 | 4,200 ₹21,000 | 4,000 ₹20,000 | 1,599 ₹7,995 Lowest |
| 4.00 | All as per item No 3 above but capacity 100 Amps 25 KA complete all as specified and directed | 3 | Each | 6,300 ₹18,900 | 5,500 ₹16,500 | 5,000 ₹15,000 | 2,499 ₹7,497 Lowest |
| 5.00 | All as per item No 3 above but capacity 160 Amps 25 KA complete all as specified and directed | 2 | Each | 8,500 ₹17,000 | 75,000 ₹1,50,000 | 7,000 ₹14,000 | 6,999 ₹13,998 Lowest |
| 6.00 | All as per item No 3 above but capacity 250 Amps 36 KA complete all as specified and directed | 3 | Each | 20,000 ₹60,000 | 15,200 ₹45,600 | 15,000 ₹45,000 | 12,399 ₹37,197 Lowest |
| 7.00 | M&L for MCB TP of capacity 32 Amp 10 KA including taking down old burn out MCB and making necessary arrangement for fixing the new one and connecting the cable complete all as specified and directed | 10 | Each | 1,750 ₹17,500 | 1,400 ₹14,000 | 1,000 ₹10,000 Lowest | 2,499 ₹24,990 |
| 8.00 | Supply, installation, commissioning and testing of LT Feeder Pillar Box outdoor type, double door made out of CRCA Sheet of 3.15 mm thick with powder coated painting and four numbers of 100 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided, the space between ground to panel should be 20 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, suitable size of lugs to connect cable to the panel I/C and O/G, internal wiring with FRLS copper wires and comprising and including the following complete all as specified and directed:-
A. Incoming:
a) MCCB 4 Pole, 63 Amps, 25 kA, Adjustable thermal and adjustable magnetic setting. - 01 No.
B. Outgoing:
a) MCB TPN 40/32 Amps - 6
b) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs
c) LED indicating lamps with colour Red, Yellow, Blue - 01 Set | 1 | Each Job | 75,000 ₹75,000 Lowest | 89,000 ₹89,000 | 95,000 ₹95,000 | 1,59,999 ₹1,59,999 |
| 9.00 | M&L for painting LT Panel/Feeder pillar/Jn boxes of any size by rubbing/ scrapping old surface with one coat of red oxide and two coats of synthetic enamel paint including repair/replacement of hinges of suitable size and external locking arrangements i.e sliding bolts by screwing/welding, tinkering works and complete all as specified and as directed. | 10 | Each Job | 3,000 ₹30,000 | 2,200 ₹22,000 | 2,000 ₹20,000 | 1,599 ₹15,990 Lowest |
| 10.00 | S&F In repair 10 Sqmm PVC Insulated Single Core Unsheathed Industrial Flexible copper Cable conforming to IS 694:1990 with Flexible Bright Annealed Copper Conductor for Voltage Grade 1100 Volts along with Copper lugs and fixed complete all as specified and as directed. | 100 | Rm | 135 ₹13,500 | 200 ₹20,000 | 90 ₹9,000 Lowest | 204 ₹20,400 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
16 Sept 2025, 6:00 pmClosed
AGE (I) SURYALANKA
AGE (I) SURYALANKA MILITARY ENGINEER SERVICES BAPATLA POST -522 102 SURYALANKA
AS PER BOQ AND TENDER DOCUMENT
2025_MES_727946_1
AGE(I)/SL/8684
Open Tender
Electrical and Maintenance Works
Works
180 days
SURYALANKA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE (I) SURYALANKA
₹19,000
20 Nov 2025
26 Aug 2025
18 Sept 2025
26 Aug 2025
16 Sept 2025
2 Sept 2025
26 Aug 2025 - 31 Aug 2025
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .