| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹48.7 LAccepted-AOC | 1 | Accepted-AOC AOC | |
| 2 | 2₹49.7 L+₹96,922.10 (1.99%)Rejected-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | 2 | Rejected-AOC NOT ACCEPTED | |
| 3 | 3₹50.0 L+₹1.2 L (2.50%)Rejected-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | 3 | Rejected-AOC NOT ACCEPTED | |
| 4 | 4₹50.4 L+₹1.7 L (3.40%)Rejected-AOC RAMBHAWAN MOUNT ABU SADAR BAZAR MOUNT ABU PIN 307 501 | MOUNT ABU | SIROHI | RAJASTHAN | 307501 | 4 | Rejected-AOC NOT ACCEPTED | |
| 5 | 5₹50.6 L+₹1.8 L (3.74%)Rejected-AOC | 5 | Rejected-AOC NOT ACCEPTED |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
26 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY BHUJ
GE ARMY BHUJ
PROVN OF CERTAIN E/M ITEMS AT SIYOT AND BHUJ UNDER GE(A) BHUJ
2023_MES_610337_1
8144
Open Tender
Civil Works - Others
Item Rate
180 days
ARMY AREA BHUJ AND SYOT
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY BHUJ
₹97,000
Yes
14 Sept 2023
24 Jul 2023
28 Aug 2023
24 Jul 2023
26 Aug 2023
8 Aug 2023
Amount
Supply,installation, testing and commissioning of 100KVA automatic servo controlled Voltage stabilizer for automatic operation,auto reset, automatic monitoring and controlling as per latest IS,oil standard as per IS 335 & ISO 9001-2008,Stabilizer standard as per IS9815 or latest IS, Protection over voltage &under voltage including over load & short circuit,single phase preventer, over current electronic protection, operating temperature 60°c, digital mutimeter 3-line display to read input,output voltage, current, PF, KVA, KW,Frequency, indication for mains on,output on ,low cut off,high cut off, heavy duty AC synchronous motor, wave form same as input,input frequency 50Hz +/-3Hz,efficiency >98%,regulation +/-1%, output voltage 415 V, three phase naturally oil cooled outdoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 100 KVA, unbalanced type, equipped with advanced micro controller control module, display module digital LCD display for true RMS voltage ¤t and power, current status indications and parameters, auto/manual facility of operation from front panel controls,mobility ruggedized construction, castor mounted for easy movement, PCC foundation above ground level as per manufaturer Drg or as directed by EIC, mounting on wheels including locking arrangement bypass facility in case of emergency with bypass switch, smooth and silent operation with servomotor and copper wound transformers in CRGO laminations complete all as specified and directed by EIC
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron strip 25 X 4 mm , (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed.
NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 4 mm galvanised iron earth strip complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core
Supply, installation, testing and comissioning 100 KVA , 415/415V (fixed ratio), 3 phase, 50 Hz, ONAN cooled oil immersed double copper wound outdoor type isolation transformer complete with first filling of IS: 335 ISI marked filtered & dehydrated transformer oil electrostatic shield between primary &secondary winding and other standard fittings / accessories delta on 415V side and star on 415 V with vector group DYN-II including overload and undercurrent protection, surge protection as per ANSI/IEEE standards C62.41,1991 (IEEE,587 Category A and B) IEC 1000-4 and 1000-5, operating temperature upto 60°C, operating humidity 95% relative (non condensing), efficiency 98%, PCC foundation above ground lever as per manufaturer Drg or as directed by EIC, mounting on wheels including locking arrangement, bypass arrangement with bypass switch, Earth to neutral voltage should be less than one volt complete all as specified and directed by EIC.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables.
S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
Supply, install, test & commissioning of microprocessor based networkable analogue addressable upto 128 nodes 2 loop fire alarm control panel, LCD display, the panel should be equipped with sufficient nos. of loop. Each loop shall have a capacity of 127 analogue addressable devices and 127 Base sounders/base sounder beacons and shall have upto 500 event logs history. Automatic battery charger, including 24 V sealed lead acid batteries sufficient for 24 hours normal working & capable of operating the system for 24 Hours during an emergency condition as required. The panel shall certified to EN54-2/EN54-4
The panel shall be fully expandable via common plug in loop driver boards, 5.25 Amp/10.25 Amp. Power supply and charger to EN-54 part4, dedicated RS232 serial port for direct PC or MODEM connection, optional remote printer. The panel shall have LAN connectivity option & all data can be controlled or stored on cloud. Panel shall have option to invert inputs and outputs, all as specified and directed. Make- Apollo, Hochiki or Honeywell.
Supply, install, test & commissioning of analogue addressable manual call point with integral short circuit isolator, analogue addressable protocol having status LED for alarming & standby mode, electronically addressed, approved by LPCB, all as specified and directed Make- Apollo, Hochiki or Honeywell
Supply, install, test & commissioning of response indicator for detector on false ceiling all as specified and directed. Make- Apollo, Hochiki or Honeywell .
Supply, fix, test & commissioning of 2 core x 1.5 sq mm. multistrand copper cable, FRLS, armoured laid through conduits fixed on wall/ceiling/loop using proper clamp/clips complete all as specified and directed.
Supply and lay PVC insulated FRLS single core copper cable of size 4 core 1.5 sqmm with steel conduit including accessories of dia 25 mm complete all as specified and directed
Supply, fix and commissioning fire alarm sounders / sierens electronic type horizontal single stage continuous normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation of +5 db 1500 m range complete all as specified and directed
Supply, install, test & commissioning of analogue addressable dual relay controller with integral short circuit isolator which allow 2 independently controlled change over relays, relays operated at 30 V DC at 1 Amps having auxiliary monitored input, followed by analogue addressable protocol, electronically addressed, approved by LPCB, all as specified and directed.
Supply, install, test & commissioning of active repeater panel to be integrated with fire alarm control panel, larger touch screen LCD display the status of any fire/fault of Integrated fire alarm panels, all as specified and directed.
Supply, fix, PVC conduit heavy duty 25mm dia size for pasing cable including saddle clips and all conncteed accessories complete all as specfied and dircted complete all as specified and directed.
supply and fix 10 watt wall mounted CD speaker complete all as speicifed and directed.
Supply and fix PA address system main consoles with in build 125W amplifier, low power consumption, Compact size complete all as sepcfied and directed. Model: Ravel Ekonics.
supply and fix microphone set complete all as sepcfied and directed.
supply and fix suitable gauge audio cable for speaker all as sepcfied and directed.
M&L for point wiring with using 2.5 qmm (nominal area) multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including conclead PVC conduit of adequate size fixed into the surface with PVC rawl plugs with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- (a) one light point controlled by one,one way switch NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision PVC modular box with modlar plate
supply and fix modular switch 6A complete all as specified and directed
supply and fix modular socket 6A 3 pin complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
S &F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V
S &F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth
M&L for flame proof distribution board SPN 8 way (total enclosed dust and flame proof IP 65 protection) including dlame proof MCB SP 5 to 30 A 240 Volts AC 10KA (4 Nos) ans SPN 20A 230V Ac 50 Hz 16KA (01 Nos) flame proof suitable for gas group I/IIA/IIB/IIC as per IS-2148 of 1981 having degree of protection IP-55 as per IS-2147 of 1962 cast aluminium alloy LM-6 construction light gray epoxy shade No 631 of IS-5 powder coating having provision for one number internal and two num,ber external screws for earthing also having O ring neoprene rubber gasket hardware in external steel construction havoing two number ET-1 to 1/4 ET bracket incoming and 12 Nos 3/4 ET outgoing cable entry from bottom side also having terminals 4 nos suitable for 200A Aluminium busbar type and 12 nos 2.5/4 sqmm clip on type and certified flame proof by CMRI Dhanbad and all specfied and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core
M&L for Wiring for circuit/submain wiring alongwith earth wire of sizes 2X 2.5 sqmm and 1X1.5sqmm of FRLS,1100V, ISI marked is PVC insulated copper conductor, single core cable drawn in and including surface mounted ERW stove enameled metallic rigid conduit of 25mm dia with necessary fixing accessories and fititng such a s tees,bend elbow conncetor NOTE: Two run of 2.5 sqmm, one run of 1.5sqmm earth conductor and one RM of ERW conduit shall be measured as one meter
Supply and fixing MCB SPN, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
S&F MCB single pole, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed
supplying, installing, commissioning and testing of inverter type split air conditioning unit 1.5 Ton indoor / outdoor complete with cordless remote control unit ,High ambient cooling,Adjustable mode and with in built with BEE 5 star rating inverter type with CFC refrigerant 1.5 tonne capacity complete and comprising of the following :- a) Refrigerant copper pipe of suction and discharge line with insulation over pipe , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including drilling into wall of any size and thicknes ,complete wiring for evaporator & condensing unit with fixing of suitable size of copper cable,b) fixing outdoor unit at suitable height and supply of bracket of 2 nos for holding outdoor unit and make odd the disturbed surface to match with the existing surface after pluging the holes complete all as specified and directed.
supply and fix metal clad AC enclosure IP 30 protection with 20A MCB SP as incomer and plug ans socket 2P+E complete all as specfied
M/L for Sub main wiring with 2 runs of PVC FRLS insulated unsheathed multi stranded single core copper conducter 4 Sqmm drawn through PVC conclead conduit including accessaries with 4sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up ,all as directed. Note: (a)2 runs of cable and one run earth wire and conduit will be measured as one length. (b) cutting chases in to the wall of any thickness , fixing suitable size conduit and drawing copper conductor and and make odd the disturbed surface to match with the existing surface after pluging the holes complete all as specified and directed.
Supply,installation, testing and commissioning of 500KVA automatic servo controlled Voltage stabilizer for automatic operation,auto reset, automatic monitoring and controlling as per latest IS,oil standard as per IS 335 & ISO 9001-2008,Stabilizer standard as per IS9815 or latest IS, Protection over voltage &under voltage including over load & short circuit,single phase preventer, over current electronic protection, operating temperature 60°c, digital mutimeter 3-line display to read input,output voltage, current, PF, KVA, KW,Frequency, indication for mains on,output on ,low cut off,high cut off, heavy duty AC synchronous motor, wave form same as input,input frequency 50Hz +/-3Hz,efficiency >98%,regulation +/-1%, output voltage 415 V, three phase naturally oil cooled outdoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 500 KVA, unbalanced type, equipped with advanced micro controller control module, display module digital LCD display for true RMS voltage ¤t and power, current status indications and parameters, auto/manual facility of operation from front panel controls,mobility ruggedized construction, castor mounted for easy movement, PCC foundation above ground level as per manufaturer Drg or as directed by EIC, mounting on wheels including locking arrangement bypass facility in case of emergency with bypass switch, smooth and silent operation with servomotor and copper wound transformers in CRGO laminations complete all as specified and directed by EIC
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron strip 25 X 4 mm , (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed.
NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 4 mm galvanised iron earth strip complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core
Supply, installation, testing and comissioning 500 KVA , 415/415V (fixed ratio), 3 phase, 50 Hz, ONAN cooled oil immersed double copper wound outdoor type isolation transformer complete with first filling of IS: 335 ISI marked filtered & dehydrated transformer oil electrostatic shield between primary &secondary winding and other standard fittings / accessories delta on 415V side and star on 415 V with vector group DYN-II including overload and undercurrent protection, surge protection as per ANSI/IEEE standards C62.41,1991 (IEEE,587 Category A and B) IEC 1000-4 and 1000-5, operating temperature upto 60°C, operating humidity 95% relative (non condensing), efficiency 98%, PCC foundation above ground lever as per manufaturer Drg or as directed by EIC, mounting on wheels including locking arrangement, bypass arrangement with bypass switch, Earth to neutral voltage should be less than one volt complete all as specified and directed by EIC.
Electricals India
ARTI CONSTRUCTION
M/s Matadeen Ramchandra Agarwal
r s corporation
KALIKAY ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .