| 1 | L-1₹23.0 LAccepted-AOC HOUSE NO 120 1 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 411014 | PUNE | MAHARASHTRA | 411014 | ₹23.0 L | L-1 | Accepted-AOC Lowest Bidder |
| 2 | L-2₹23.2 L+₹28,600 (1.25%)Rejected-Finance HOUSE NO1201 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 410 501 | PALGHAR | MAHARASHTRA | 410501 | ₹23.2 L+₹28,600 (1.25%) | L-2 | Rejected-Finance Other than Lowest Bidder |
| Sl No | Description | Qty | Unit | M/s. AMIT ASSOCIATES L2 | NILESH SUBHASH KARALE L1 |
|---|---|---|---|---|---|
| 1.00 | Supply and Installed testing and commissioning of AC, 3 phase, 50 Hz 160 KVA capacity transformer step down outdoor/indoor type 11/0.433 KV 50 Hz copper wound, oil cooled (ONAN) complete with oil tank including forst fill of ISI marked insulating oil up to top level, oil level indicator, breather with silica gel, lifting works, drain valve ,air vent valve, tackel wheel with channel and lowring arrangement with external cooling tubes, core type,delta connected on primery side (HV) and star connected on secondery side (LV) in accodance with vector symbol DYN-11 (vector Group-4) with neutral brought out on secondary side (LV side) OFF load tap changer with mannual voltage regulation 0.433 KV suitable steps/position on HV side to galvanised of 22KV on LV side and provision of following accessories and connecting with electrical system, earthing etc, including all jionting materials testing and commissioning all as per IS 1180-2014 anf energy efficiency level-II including filling of transformer oil having conforming to IS:335-1993 and shall of following :- | 1 | Each | 9,40,000 ₹9,40,000 Lowest | 9,50,000 ₹9,50,000 |
| 1.0103 Nosporcelene HT bushings with brass/gun metal bushing rods complete with nut and washers on primary (HV) side, suitable for HT, 11KV XLPE cable of size 3 core 95/120sqmm. | |||||
| 1.0204 Nosporcelene HT bushings with brass/gun metal bushing rods complete with nut and washers onsecondary (LV) side, suitable for LT, 11KV/0.433 KV XLPE Cable. | |||||
| 1.03Oil conservator with filter type drain valve and oil level guage. | |||||
| 1.04De-hydrating breather with first fill dehydrating agent (silica gel). | |||||
| 1.05Explosive vent. | |||||
| 1.06Thermometer pocket on tank cover. | |||||
| 1.07One No 100MM dia, dial type thermometer vapour pressure type having range 0-120 degree colsius with metal guard having minimum reading ature indicator with resisting device for transformer. | |||||
| 1.08Two earthing terminals to be provided diagonally on either side of tank ver to facilitate fixing of 50x6mm galvanised from strip for earthing of neutral and body. | |||||
| 1.09Rating plate and terminal marking. | |||||
Tender Value
₹17.5 L
EMD Value
₹35,000
Closing Date
30 Sept 2024, 6:00 pmClosed
GE(AF) Naliya No. 1
GE AIR FORCE STATION NALIYA NO 01
SPECIAL REPAIRS TO TRANSFORMERS AND PROVN OF LT PANEL AND 30KVA STABILIZER FOR SDR RADIO SETS AT AF STATION NALIYA
2023_MES_634420_4
8946/E
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naliya
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(AF) Naliya No. 1
₹35,000
Yes
27 Aug 2025
9 Sept 2024
3 Oct 2024
9 Sept 2024
30 Sept 2024
16 Sept 2024
Amount
Supply and Installed testing and commissioning of AC, 3 phase, 50 Hz 160 KVA capacity transformer step down outdoor/indoor type 11/0.433 KV 50 Hz copper wound, oil cooled (ONAN) complete with oil tank including forst fill of ISI marked insulating oil up to top level, oil level indicator, breather with silica gel, lifting works, drain valve ,air vent valve, tackel wheel with channel and lowring arrangement with external cooling tubes, core type,delta connected on primery side (HV) and star connected on secondery side (LV) in accodance with vector symbol DYN-11 (vector Group-4) with neutral brought out on secondary side (LV side) OFF load tap changer with mannual voltage regulation 0.433 KV suitable steps/position on HV side to galvanised of 22KV on LV side and provision of following accessories and connecting with electrical system, earthing etc, including all jionting materials testing and commissioning all as per IS 1180-2014 anf energy efficiency level-II including filling of transformer oil having conforming to IS:335-1993 and shall of following :-
03 Nosporcelene HT bushings with brass/gun metal bushing rods complete with nut and washers on primary (HV) side, suitable for HT, 11KV XLPE cable of size 3 core 95/120sqmm.
04 Nosporcelene HT bushings with brass/gun metal bushing rods complete with nut and washers onsecondary (LV) side, suitable for LT, 11KV/0.433 KV XLPE Cable.
Oil conservator with filter type drain valve and oil level guage.
De-hydrating breather with first fill dehydrating agent (silica gel).
Explosive vent.
Thermometer pocket on tank cover.
One No 100MM dia, dial type thermometer vapour pressure type having range 0-120 degree colsius with metal guard having minimum reading ature indicator with resisting device for transformer.
Two earthing terminals to be provided diagonally on either side of tank ver to facilitate fixing of 50x6mm galvanised from strip for earthing of neutral and body.
Rating plate and terminal marking.
Oil level gauge.
Oil level filter valve.
Lifting lugs.
Oil filling hole with cap/plug with connecting plate complete.
Air relief valve plug.
Fore plain solid cast steel detachable rockters.
First filling of new and usable transformer oil IS-335/93 (Fourth revision) marked filtered and tested up to 45KV dielectric strenght 2.5mm between testing electroly.
Separate neutral bushing to be provided for earthing.
Provision of 2 nos danger boards 250/200mm size made of 1.6mm thick plate, viterous enamale white letters figures of voltage and conventional skall and benes in singal red colours on frant side. The rear side of the plate also be enamalled.
Any other fittings/accessories so as to confirm the whole transformer to IS 1180 : 2014.
Tapping range (+) 7.5% to (-) 7.5% of 2.5% each, 7 steps.
Percentage impedance at 75 at rated - 4.5%
LV winding - 160KVA (copper wound) Enegergy efficients level.
Supply and Installed testing and commissioning of AC, 3 phase, 50 Hz 250 KVA capacity transformer step down outdoor/indoor type 11/0.433 KV 50 Hz copper wound, oil cooled (ONAN) complete with oil tank including forst fill of ISI marked insulating oil up to top level, oil level indicator, breather with silica gel, lifting works, drain valve ,air vent valve, tackel wheel with channel and lowring arrangement with external cooling tubes, core type,delta connected on primery side (HV) and star connected on secondery side (LV) in accodance with vector symbol DYN-11 (vector Group-4) with neutral brought out on secondary side (LV side) OFF load tap changer with mannual voltage regulation 0.433 KV suitable steps/position on HV side to galvanised of 22KV on LV side and provision of following accessories and connecting with electrical system, earthing etc, including all jionting materials testing and commissioning all as per IS 1180-2014 anf energy efficiency level-II including filling of transformer oil having conforming to IS:335-1993 and shall of following :-
03 Nosporcelene HT bushings with brass/gun metal bushing rods complete with nut and washers on primary (HV) side, suitable for HT, 11KV XLPE cable of size 3 core 95/120sqmm.
04 Nosporcelene HT bushings with brass/gun metal bushing rods complete with nut and washers onsecondary (LV) side, suitable for LT, 11KV/0.433 KV XLPE Cable.
Oil conservator with filter type drain valve and oil level guage.
De-hydrating breather with first fill dehydrating agent (silica gel).
Explosive vent.
Thermometer pocket on tank cover.
One No 100MM dia, dial type thermometer vapour pressure type having range 0-120 degree colsius with metal guard having minimum reading erature indicator with resisting device for transformer.
Two earthing terminals to be provided diagonally on either side of tank cover to facilitate fixing of 50x6mm galvanised from strip for earthing of neutral and body.
Rating plate and terminal marking.
Oil level gauge.
Oil level filter valve.
Lifting lugs.
Oil filling hole with cap/plug with connecting plate complete.
Air relief valve plug.
Fore plain solid cast steel detachable rockters.
First filling of new and usable transformer oil IS-335/93 (Fourth revision) marked filtered and tested up to 45KV dielectric strenght 2.5mm air gap between testing electroly.
Separate neutral bushing to be provided for earthing.
Provision of 2 nos danger boards 250/200mm size made of 1.6mm thick plate, viterous enamale white letters figures of voltage and conventional skall and benes in singal red colours on frant side. The rear side of the plate also be enamalled.
Any other fittings/accessories so as to confirm the whole transformer to IS 1180 : 2014.
Tapping range (+) 7.5% to (-) 7.5% of 2.5% each, 7 steps.
Percentage impedance at 75 at rated - 4.5%
LV winding - 160KVA (copper wound) Enegergy efficients level.
Supply, fabricate, test and commissioning of LT electrical out door distribution panel board floor mounted cubical type dust proof, weather proof, vermin proof, astehically desiggned, having at least IP-54 degree of ingress protection, fabricated from 3mm thick CRCA sheet with front and rear opening including bus bar chamber, continuous GI strip earth bus bar 4 strips of Copper bus bar suitable Amps capacity, insulated color sleeves, procelain/epoxy insulators, rail channels cable alloy, danger notice board including over angle iron frame of size 40 x 40 x 6mm, 30 cm grouted in ground floor and 30 cm above GL including necessary excavation, foundation, PCC etc complete with locking arrangement duly powder coated painted of approved color connecting incoming & outgoing cable connection with suitable lugs, nuts, bolts, washers and cable joints, prewired complete with PVC insulated fire retardant copper conductor cable complete including:-
Servo controlled voltage stabilizer (Confirming as per BIS: 9815: Part 1: 1994 reaffirmed 2009) 3-phase, 50Hz, Naturally Oil Cooled, Indoor/Outdoor, Unbalanced Type, Copper Wound, Digital Display st Type, Relay Free Smooth and Silent Operation with 1 filling of Transformer oil (IS335: 1993 reaffirmed 2005) having following specification: (1) Input voltage 300V-480V or as per ground requirements (2) Output voltage stabilized at any designed/desired voltage 415V ± 1% (Adjustable) (3) Rated frequency 50 Hz (4) No distortion in wave form (5) Response time not to exceed 10 mille seconds (6) Sensitivity (±)1% (7) Rate of correction 8 Volt/second for single phase and 20 Volt/second for phase to phase (8) No load losses less than 0.5% (9) Full load losses less than 2.5% (10) Duty cycle - continuous 24 x 7 (11) Efficiency more than 95% (12) Type of load: 3 phase, unbalanced type (13) Digital display Voltmeter/Ampmeter (14) Capacity: 30 KVA (15) Make : Volina and equivalant PROTECTIONS 1. Over load/Short circuit protections 2. High/Low voltage cut off 3. By pass arrangement in case of emergency 4. Single phase sequence change protection OPTIONAL PROTECTION Ingress Protection (IP) upto IP42/IP45 also incliudes grouted on floor which is 1.3 m above GL including necessary excavation, foundation, PCC etc complete with locking arrangement duly powder coated painted of approved color connecting incoming & outgoing cable connection with suitable lugs, nuts, bolts, washers and cable joints, prewired complete with PVC insulated fire retardant copper conductor cable complete all as directed by EIC.
M & L for Earthing complete with Copper earth plate electrode 600x600x3.15 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to copper earth strip of 20 x 3 mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shwon in electrical plate no 3 of SSR part 1 including Charcoal, Rock salt, necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reingorcement, watering funnel 32 mm dia light grade for protection of earth electrode 20 mm dia for watering all as speicified and directed and tested on completion. Note : - The unit rate quoted shall deemed to have included for GI protection pipe, Copper earth strip up to 7.5 mtr, GI water pipe, wire mesh , funnel , excavation, RCC pit cover complete all as specified.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm copper strip complete all as specified and as directed.
M/s. AMIT ASSOCIATES (BID ID -3112147)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .