| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 CrAccepted-AOC 0 TANDA VILLAGE KHAIRPUR TANDA AYODHYA VILLAGE TOWN POST MAKHDOOM NAGAR CITY AMBEDKAR NAGAR AMBEDAKAR NAGAR UTTAR PRADESH 224190 INDIA | AMBEDKAR NAGAR | UTTAR PRADESH | 224190 | ₹3.9 Cr | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹5.0 Cr+₹1.1 Cr (27.3%)Rejected-Finance OPP RAM MANDIR NALIYA KUTCH 370655 | KACHCHH | GUJARAT | 370655 | ₹5.0 Cr+₹1.1 Cr (27.3%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹5.7 Cr+₹1.7 Cr (44.2%)Rejected-Finance | ₹5.7 Cr+₹1.7 Cr (44.2%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹5.7 Cr+₹1.8 Cr (45.3%)Rejected-Finance PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | ₹5.7 Cr+₹1.8 Cr (45.3%) | L4 | Rejected-Finance Not lowest |
| 5 | L5₹6.2 Cr+₹2.2 Cr (57.1%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹6.2 Cr+₹2.2 Cr (57.1%) | L5 | Rejected-Finance Not lowest |
Tender Value
Refer Docs
EMD Value
₹4.3 L
Closing Date
10 Oct 2022, 6:00 pmClosed
CE(AF) GANDHINAGAR
LEKEVADA PATIA, CHILODA, CRPF CAMPUS GANDHINAGAR
RECONSTRUCTION OF MD ACCN FOR AIRMEN (PH-II) AT AF STN NALIYA
2022_MES_547269_1
88236
Open Tender
Civil Works
Works
540 days
GE(AF) NALIYA
AS PER NIT TENDERS DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE(AF) NALIYA
₹4.3 L
Yes
22 Oct 2022
24 Aug 2022
11 Oct 2022
24 Aug 2022
10 Oct 2022
27 Sept 2022
29 Aug 2022 - 7 Sept 2022
Amount
NOTE: Schedule ‘A’ Part I to X are under Ser No. 1.00 to 10.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out by the Contractor for Excavation & Earth works as listed in Sch `A’ Part II
Lump sum price worked out by the Contractor for Internal Water Supply as listed inSch `A’ Part III
Lump sum price worked out by the Contractor for Internal Electrification as listed in Sch 'A' Part IV
Lump sum price worked out by the Contractor for Road/Path/Culvert/Hard standing as listed in Sch 'A' Part V
Lump sum price worked out by the Contractor for Sewage Disposal as listed in Sch `A’ Part VI.
Lump sum price worked out by the Contractor for External Water supply as listed in Sch `A’ Part VII
Lump sum price worked out by the Contractor for External Electrification as listed in Sch `A’ Part VIII
Lump sum price worked out by the Contractor for Fire Fighting as listed in Sch `A’ Part IX.
Lump sum price worked out by the Contractor for Demolition and Dismantling as listed in Sch `A’ Part X.
SCHEDULE 'A' PART - XI (MISC ITEMS) (Note : The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
Supply and fix, testing and commisioning of black steel pipes confirming to IS: 1239/3589 (Heavy duty) including all fittings like anchor fasteners, couplings, bends, elbows, tees, flanges etc. welding as required painting with one coat of red-oxide primer and two or more coats of synthetic enamel paints to give an even shade incl all civil breakages, cutting holes and chases in brick walls , filling the annular space between pipe & wall/slab/beam with hand mixed concrete 1:2:4 and making good with cement mortar completeall as directed for size 40 mm dia (wall thickness as per IS-1239) complete all as specified and directed.
Supply installation testing and commissioning of Carbon Dioxide (CO2) type Fire Extinguisher capacity 4.5 kg conforming to IS 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets, PESO/CCOE Approved cylinder body and confirms to IS : 7285, High grade Enamel painted externally with PO Red finish, wheel operated controllable discharge high Pressurebress valve confirming to IS : 3224 which is provided with pressure relief dischargeable and easy to service, non conductive agent for electrical use without risk to operator ,CO2 gas disappiears quickly leaving no residue applicable on class B & C and electrically started fire, B rating 21B started fire, A Rating-3A, Rating 21B, safety pin is of SS material, Sheet metal thickness: 1.0 mm, Helium Leak Detection Tested ISI Approved IS 15683:2006. 5 years Warranty complete all as specified and directed.
Supply installation testing and commissioning of ABC type Fire Extinguisher capacity 6 kg filled with Mono Ammonium Phosphate powder 50% conforming to IS 14609, powder coated MS body stored Pressure type Discharge time 18 Sec, controllable discharge is 90%, applicable on class A,B & C and electrically started fire, A Rating-3A, Rating 21B, safety pin is of SS material, Sheet metal thickness: 1.0 mm, Helium Leak Detection Tested ISI Approved IS 15683:2006. 5 years Warranty complete all as specified and directed.
Material and Labor for costruction of valve chamber, with inner space of size (1050mm x 750mm x 1000mm) (L x B x D) in PCC(1:3:6) block masonry built in CM(1:4) with MS cover 3 mm thick and 50 x 50 x 6 mm angle iron frame work with locking arrangements including excavation and earth work PCC (1:4:8) type D2 for foundation PCC /Bed coping in cement concrete (1:2:4)type B-1 plastering 15 mm thick with CM(1:4) t over a coat of red oxide primer on all steel surfaces complete all as specified and directed.
Supply, install, testing and commissioning LT Panel, Outdoor type, dust and vermin proof, totally enclosed, platform mounted, factory made (Protection Class IP-54) having front openable shutter with locking arrangement made out of CRCA steel sheet 3.15 mm thick with MS angle iron frame work of size 40 mm x 40 mm x 6 mm thick, duly painted all as specified including necessary foundation bolts, PCC ( 1:2:4), type B-1 platform of suitable size for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system with suitable insulated copper busbar of capacity not less than 200 Amps and shall be complete with internal wiring with copper conductor, and including the following accessories : -
Taking out unserviceable LT cables from excavated trenches, ducts, wall, pole etc including removing cable covers, sand, cable joints, pipes, clamps etc and including earthwork excavation and returning and filling the trenches etc, for the cable sizes up to 25 sqmm 2/4 core complete all as specified and directed.
Taking out unserviceable GI tubing from excavated trenches, , wall, etc for the sizes up to 25 mm including earthwork excavation and returning and filling the trenches etc complete all as specified and directed.
Supply, install, testing and commissioning and testing factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) indoor type, platform mounted, including suitable angle iron (4 Nos leg) for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 300 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 2.00 mm CRCA sheet 75mm x 30 mm thick MS Channel frame, duly powder coated finish ,thimbling and cable entry boxes with cable gland incld painting with two coat of synethetic enamel paint over a coat of red oxide primer. Front and back side opening type with aprons for cable entry with double door shutter and locking arrangement, danger plate and earthing terminal and suitable PCC work. The scope of work includes provision of the following :-
(A) Main Incoming (a) MCCB 4 pole 100 Amps, 36 KA, 415V -01 No ( from proposed commercial panel) (b) Bus bar (copper strip) 300 Amp, 4 pole (c) Digital panel meter (Amp,Voltage meter) including CTs -01 No. (d) Digital Indication Lamp Set-1 (B) Outgoing (e) MCCB SPN 40 Amp 230 V 50 Hz - 3 Nos (f) Slot for electronic energy meter - 12 Nos. Note : Contractor shall submit GA drawing for approval of GE before procurement.
M&L for TV socket along with non metallic rigid PVC heavy duty conduit concealed in wall (min 20mm dia (external)) from suitable entry point upto socket. complete all as specified and directed.
M & L for submain wiring with one run of three core PVC insulated and FR PVC sheathed copper cable of 2.5 Sqmm multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC concealed conduits heavy duty grade ISI marked 25 mm dia (External) with wall thickness not less than 1.8 mm with conduit accessories complete all as specified and directed Note: one run of cable and 1 run of conduit shall be measured and paid as one meter length of unit.
M & L for submain wiring with one run of three core PVC insulated and FR PVC sheathed copper cable of 1.5 Sqmm multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC concealed conduits heavy duty grade ISI marked 25 mm dia (External) with wall thickness not less than 1.8 mm with conduit accessories complete all as specified and directed Note: one run of cable and 1 run of conduit shall be measured and paid as one meter length of unit.
M/s. Shree Shakti Enterprise
RAMDEV CONSTRUCTION CO.
KALIKAY ENTERPRISES
Vijay Construction Co
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .