NAVAL DOCKYARD VISAKHAPATNAM PIN 530014
RFP FOR SR OF TUG SAHAYAK
2019_NAVY_299364_1
COM/0346/SHK/SR OL-20/A
Open Tender
Marine Services
120 days
NAVAL DOCKYARD VISAKHAPATNAM
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹22.4 L
Yes
NAVAL DOCKYARD VISAKHAPATNAM
24 Jan 2020
19 Nov 2019
20 Dec 2019
19 Nov 2019
19 Dec 2019
30 Nov 2019
19 Nov 2019 - 19 Dec 2019
6 Dec 2019
HULL DEFECT LIST/ WORK PACKAGE - SR 19 001 Docking- Vessel to be docked in both versions. Note 1:- Firms not to quote view docking, undocking and dock blocks preparation will be done by Navy and the job is required to be carried out in Navy Premises (i.e ND(V) slipway). Note 2:- Last date of Undocking -06 Mar 17
002 Hull Cleaning (a) Under Water and Boot Top Area HP jet clean entire under water area and boot top area (with a pressure not exceeding 3000 PSI) including ship side and remove the marine growth/barnacles and prepare for survey. (a) U/W area: 350 Sqm,(b) Boot Top area: 150 Sqm
002 Hull Cleaning (b) Above Water Area including Bulwark Clean the entire above water area with HP Jet washing (not exceeding 3000 PSI) and present for survey
002 Hull Cleaning (c) Super Structure Area Clean the entire Super Structure Area area with HP Jet washing (not exceeding 3000 PSI) and present for survey
002 Hull Cleaning (d) Weather Decks Area (including fittings) Clean the entire weather deck area with HP Jet washing (not exceeding 3000 PSI) and present for survey
002 Hull Cleaning (e) Miscellanious Tanks Manually clean Following tanks and present for survey Fore Peak Tanks (03nos) Ballast Tanks(02 Nos), Cable locker-01 Fresh water tanks Fire fightining foam tanks Cofferdams (02)
002 Hull Cleaning (f) Internal Compartments - Engine Room and SRP compartment Manually clean following internal compartments and present for survey. (i) Engine room. (ii) SRP compartment
002 Hull Cleaning (g) Fuel Tanks Fuel / RU Tanks Manually clean following Fuel/RU tanks and present for survey. (a) Fuel Tank (02 nos) (b) RU Tanks (02 nos) (c) Lub Oil Tank (02 nos)
003 Hull survey (a) Visual Survey External and Internal Hull survey. Carry out visual and hammer survey/UTG survey in accordance with NO 01/15 of under water hull , boot top area, above water hull, super structure, weather decks and all internal compartments(i.e. FW tanks, ballast tanks, fore peak tank, engine room, steering compartment, FO tanks, cofferdams, all stiffeners and deck fittings etc..All manholes to be inspected and repaired to ensure water tightness, chalk impression test to be carried out. Approx. area: 3000 Sqm Firm to submit 07 copies of Hull survey report . Firm to prove the welds by non-destructive tests and by hose test on completion of welding.
003 Hull survey (b) UTG Survey External and Internal Hull survey. Quote for UTG survey points at various locations.
004 Steel Renewals Quote for steel renewal at various locations as per survey report. Note 1:- Quoted repair cost shall include cost of both sides blasted and primed Grade `A’ quality ship building steel for shell and IS 2062 Grade `B’ quality steel for non structural works, degutting/regutting/ renewal of all obstructions in way of steel renewals including lagging/panelling, minor fittings/ equipments with their foundations, ventilation systems, staging etc., as indicated by survey team / RMT, proving of the weld runs by non-destructive tests and by hose test on completion of welding, pressure testing and proving of tanks where steel renewal undertaken etc. Note 2:- Firms to indicate cost of new panelling(2mm thick) and Lagging (2" MFMB) material in the budgetary cost for 50 sqm each.
005 Build ups Carry out build ups as indicated by the Hull survey team/ Surveyor (a) 25 x 25 mm - 300 Nos
005 Build ups Carry out build ups as indicated by the Hull survey team/ Surveyor (b) 50 x50 mm - 150 Nos
006 Fairing Carryout fairing of deformed structures as indicated by Hull Survey Team/ Surveyor
007 Re-welding run Carry out re-welding runs on weld seams as indicated by Hull survey team/ QC/ RMT.
008 Sea tube (a) Hydro jet blasting, survey and pressure testing of sea tube including sea chest to be carried out. Dia - 300mm
008 Sea tube (b) carryout renewal of defective seatubes, OD-300mm, schedule 80.
009 Draught Marks Draught marks corroded/eaten away, to be renewed and painted. Both Roman and Numeric.
010 Sacrificial Anodes (a) Renew Sacrificial anodes (MK-I) those consumed more than 50% Note:- Anodes Navy/COY supply.
010 Sacrificial Anodes (b) Renew Sacrificial anodes (MK- V) those consumed more than 50% Note:- Anodes Navy/COY supply.
011 Surface preparation. Under Water area including Boot top area (a) Spot blasting to SA 2.5 on paint damaged areas/ renewed plate areas as per the paint OEM rep recommendation for paint application.
011 Surface preparation Under Water area including Boot top area (b) Sweep blasting to SA 1 on the rest of the underwater areas for removal of anti-fouling and application of tie coat and 03 coats of anti-fouling.
012 Painting Under Water Area including Boot top area - AKZO NOBEL Scheme. Paint under water area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: Primer - Intergard 269 primer -40-50 microns
012 Painting Under Water Area including Boot top area - AKZO NOBEL Scheme. Paint under water area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat: Anti Corrosive - Intersheild 300 (Aluminium) - 150 microns
012 Painting Under Water Area including Boot top area - AKZO NOBEL Scheme. Paint under water area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Anti Corrosive - Intersheild 300 (Bronze) - 150 microns
012 Painting Under Water Area including Boot top area - AKZO NOBEL Scheme. Paint under water area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (d) 4th Coat: Tie Coat: Intergard 263 - 125 microns
012 Painting Under Water Area including Boot top area - AKZO NOBEL Scheme. Under Water Area - Painting - AKZO NOBEL Scheme. Paint under water area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (e) 5th Coat: A/F: Intersmooth360(Brown) - 150 microns
012 Painting Under Water Area including Boot top area - AKZO NOBEL Scheme. Paint under water area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (f) 6th Coat: A/F: Intersmooth360(Dark Red) - 150 microns
012 Painting Under Water Area including Boot top area - AKZO NOBEL Scheme. Paint under water area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (g) 7th Coat: A/F: Intersmooth360(Brown) - 150 microns
012 Painting Under Water Area including Boot top area - AKZO NOBEL Scheme. Paint under water area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (h) 8th Coat: A/F Intersmooth360 (Black) - 150 microns DFT
013 Surface prepartion Above Water Area and Bulwark including guardrails (a) Carry out mechanical cleaning to ST3 standard for paint application as per survey report by Paint OEM rep
013 Surface prepartion Above Water Area and Bulwark including guardrails (b) Carry out mechanical cleaning to ST1 standard for paint application as per survey report by Paint OEM rep
014 Painting Above Water Area and Bulwark including guardrails - AKZO NOBEL Scheme. Paint above water area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: Intergard 269 50 microns DFT
014 Painting Above Water Area and Bulwark including guardrails - AKZO NOBEL Scheme. Paint above water area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat:Intergard 5600 (Grey) - 125 microns DFT
014 Painting Above Water Area and Bulwark including guardrails - AKZO NOBEL Scheme. Paint above water area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Intergard 5600 (Red) - 125 microns DFT
014 Painting Above Water Area and Bulwark including guardrails - AKZO NOBEL Scheme. Paint above water area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (d) 4th Coat:Interthane 990 (Grey) - 60 microns DFT
015 Surface prepartion Super Structure and Deck Fittings (a) Carry out mechanical cleaning to ST3 standard as survey report of Paint OEM for paint application.
015 Surface prepartion Super Structure and Deck Fittings (b) Carry out mechanical cleaning to ST1 standard as survey report of Paint OEM for paint application.
016 Painting Superstructure and Deck fittings - AKZO NOBEL Scheme. Paint super structure area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: Intergard 269 - 50 microns DFT
016 Painting Superstructure and Deck fittings - AKZO NOBEL Scheme. Paint super structure area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat:Intergard 5600 (Grey) - 125 microns DFT
016 Painting Superstructure and Deck fittings - AKZO NOBEL Scheme. Paint super structure area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Intergard 5600 (Red) - 125 microns DFT
016 Painting Superstructure and Deck fittings - AKZO NOBEL Scheme. Paint super structure area with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (d) 4th Coat:Interthane 990 (Grey) - 60 microns DFT
017 Surface prepartion Weather Deck and fittings (a) Carry out mechanical cleaning to ST3 standard for paint application as per survey report by Paint OEM rep
017 Surface prepartion Weather Deck and fittings (b) Carry out mechanical cleaning to ST1 standard for paint application as per survey report by Paint OEM rep
018 Painting Weather Deck and fittings - AKZO NOBEL Scheme. Paint weather decks and fittings with following paint scheme. Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: primer - Intergard 269 -50 microns DFT
018 Painting Weather Deck and fittings - AKZO NOBEL Scheme. Paint weather decks and fittings with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat: Intersheild 300 - 300 microns
018 Painting Weather Deck and fittings - AKZO NOBEL Scheme. paint with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Intersheild 852 (Non Skid D.A. Grey) - 800 microns
019 Surface preparation Internal compartments -Tanks (a) Carry out mechanical surface preparation to ST 3 standards for paint application whereever peeled off / paint defective in fore peak (02) ballast tank(01) cable locker (01) Coffer dam (01)
019 Surface preparation Internal compartments -Tanks (b) Carry out mechanical surface preparation to ST 1 standards for paint application whereever peeled off / paint defective in fore peak (02) ballast tank(01) cable locker (01) Coffer dam (01)
020 Painting Fore peak Tank, Ballast tank, Cable locker and Cofferdam - AKZO NOBEL Scheme. Paint fore peak tanks,cofferdams and cable locker with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: primer - Intergard 269 -50 microns DFT
020 Painting Fore peak Tank, Ballast tank, Cable locker and Cofferdam - AKZO NOBEL Scheme. Paint fore peak tanks,cofferdams and cable locker with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat: Anticorrosive Intershield 300 (Aluminum) - 150 microns
020 Painting Fore peak Tank, Ballast tank, Cable locker and Cofferdam - AKZO NOBEL Scheme. Paint fore peak tanks,cofferdams and cable locker with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3rd Coat: Anticorrosive Intershield 300 (Bronze) - 150 microns
021 Surface preparation Fresh water tanks, Foam tank and Fresh water gravity tanks. (a) Carry out mechanical cleaning to ST 3 standard as survey report of Paint OEM for paint application. Fresh water tanks, Foam tank and Fresh water gravity tanks
021 Surface preparation Fresh water tanks, Foam tank and Fresh water gravity tanks. (b) Carry out mechanical cleaning to ST1 standard as survey report of Paint OEM for paint application. Fresh water tanks, Foam tank and Fresh water gravity tanks
022 Painting Fresh water tanks, Foam tank and Fresh water gravity tanks - AKZO NOBEL Scheme. AKZO NOBEL Scheme. Paint both fresh water tanks/ foam tanks with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: Interline 850 - 150 microns DFT
022 Painting Fresh water tanks, Foam tank and Fresh water gravity tanks - AKZO NOBEL Scheme. Paint both fresh water tanks/ foam tanks with following paint scheme:- note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2rd Coat: Interline 850 - 150 microns DFT
023 Surface Preparation Internal Compartments - Bilges of Engine Room and ASP Compartment (a) Carry out mechanical cleaning to ST 3 standard as survey report of Paint OEM for paint application.
023 Surface Preparation Internal Compartments - Bilges of Engine Room and ASP Compartment (b) Carry out mechanical cleaning to ST 1 standard as survey report of Paint OEM for paint application.
024 Painting Bilges of Engine Room and ASP Compartment - AKZO NOBEL Scheme. Paint bilges of Engine room and ASP compartment with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: primer - Intergard 269 - 50 microns DFT
024 Painting Bilges of Engine Room and ASP Compartment - AKZO NOBEL Scheme. Paint bilges of Engine room and ASP compartment with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also (b) 2nd Coat: Anticorrosive - Intersheild 300 (Aluminium) - 150 microns
024 Painting Bilges of Engine Room and ASP Compartment - AKZO NOBEL Scheme. Paint bilges of Engine room and ASP compartment with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also (c) 3rd Coat: Anticorrosive - Intersheild 300 (Bronze) - 150 microns
025 Surface Preparation Bulkheads of Engine room and SRP compartments and living spaces. (a) Carry out mechanical cleaning to ST 3 standard as survey report of Paint OEM for paint application.
025 Surface Preparation Bulkheads of Engine room and SRP compartments and living spaces. (b) Carry out mechanical cleaning to ST 1 standard as survey report of Paint OEM for paint application.
026 Painting Bulkheads of Engine room and SRP compartments and living spaces - Akzo Nobel Scheme. Paint bulkheads of Engine room and SRP compartments and living spaces ,with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (a) 1st Coat: primer - Intergard 269 - 50 microns DFT
026 Painting Bulkheads of Engine room and SRP compartments and living spaces - Akzo Nobel Scheme. Paint bulkheads of Engine room and SRP compartments and living spaces ,with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (b) 2nd Coat: White interior fire retradant paint(JSS 8010-72:2001-100 microns
026 Painting Bulkheads of Engine room and SRP compartments and living spaces - Akzo Nobel Scheme. Paint bulkheads of Engine room and SRP compartments and living spaces ,with following paint scheme:- Note:- Quoted repair cost shall be inclusive of cost of paints also. (c) 3nd Coat: White interior fire retradant paint(JSS 8010-72:2001-100 microns
027 Air Pressure Testing Air Pressure Test the following tanks to 0.14 Kg per Sq. Cms and rectify the defects any observed during pressure testing and prove. note:- APT and proving of those tanks wherein steel renewal undertaken as part of steel renewal DL. 0003(c) above is that of Firm's liability with No Additional Cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this DL. Serial. (a) Fresh Water Tank
027 Air Pressure Testing Air Pressure Test the following tanks to 0.14 Kg per Sq. Cms and rectify the defects any observed during pressure testing and prove. note:- APT and proving of those tanks wherein steel renewal undertaken as part of steel renewal DL. 0003(c) above is that of Firm's liability with No Additional Cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this DL. Serial. (b) Ballast Tank
027 Air Pressure Testing Air Pressure Test the following tanks to 0.14 Kg per Sq. Cms and rectify the defects any observed during pressure testing and prove. note:- APT and proving of those tanks wherein steel renewal undertaken as part of steel renewal DL. 0003(c) above is that of Firm's liability with No Additional Cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this DL. Serial. (c) Forepeak Tank
027 Air Pressure Testing Air Pressure Test the following tanks to 0.14 Kg per Sq. Cms and rectify the defects any observed during pressure testing and prove. note:- APT and proving of those tanks wherein steel renewal undertaken as part of steel renewal DL. 0003(c) above is that of Firm's liability with No Additional Cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this DL. Serial. (d) Fuel Tank
027 Air Pressure Testing Air Pressure Test the following tanks to 0.14 Kg per Sq. Cms and rectify the defects any observed during pressure testing and prove. note:- APT and proving of those tanks wherein steel renewal undertaken as part of steel renewal DL. 0003(c) above is that of Firm's liability with No Additional Cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this DL. Serial. (e) Aft Peak Tank
027 Air Pressure Testing Air Pressure Test the following tanks to 0.14 Kg per Sq. Cms and rectify the defects any observed during pressure testing and prove. note:- APT and proving of those tanks wherein steel renewal undertaken as part of steel renewal DL. 0003(c) above is that of Firm's liability with No Additional Cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this DL. Serial. (f) Fire fighting Foam Tank
027 Air Pressure Testing Air Pressure Test the following tanks to 0.14 Kg per Sq. Cms and rectify the defects any observed during pressure testing and prove. note:- APT and proving of those tanks wherein steel renewal undertaken as part of steel renewal DL. 0003(c) above is that of Firm's liability with No Additional Cost and those tanks where no steel renewals undertaken only would be considered for payment as per the indicated rates under this DL. Serial. (g) Cofferdam
028 Bilge Platform plate Renew bilge platform plate. Material- aluminium chequered plate, thickness- 05 mm
029 Bilge Platform Supporting brackets Bilge platform supporting brackets at indicated locations to be renewed. Mat - ms
030 Key Fender Head & Stern fenders All key fenders to be removed, inspected and surveyed and necessary repairs to be attended on fender securing brackets(C Channel) and associted hull fittings ,Head and stern D shaped key fenders perished/ cracked. coaming plate, securing nuts/ bolts and partition plates in between fenders corroded, thinned and holed. All fasteners to be renewed. Fastener mat : MS (a) Top and bottom securing brackets/ plates and partition plates length varies from 430 mm to 850 mm x 8mm thick
030 Key Fender Head & Stern fenders All key fenders to be removed, inspected and surveyed and necessary repairs to be attended on fender securing brackets(C Channel) and associted hull fittings ,Head and stern D shaped key fenders perished/ cracked. coaming plate, securing nuts/ bolts and partition plates in between fenders corroded, thinned and holed. All fasteners to be renewed. Fastener mat : MS (b) Head key fenders to be renewed with white colour fenders of EPDM rubber as per NES 170.Shore Hardness - 70 to 74 (+/- 5) . Crossection size 300mmx300mm. Length of fenders varies between 430mm to 850 mm.
030 Key Fender Head & Stern fenders All key fenders to be removed, inspected and surveyed and necessary repairs to be attended on fender securing brackets(C Channel) and associted hull fittings ,Head and stern D shaped key fenders perished/ cracked. coaming plate, securing nuts/ bolts and partition plates in between fenders corroded, thinned and holed. All fasteners to be renewed. Fastener mat : MS (c) Stern key fenders to be renewed with white colour fenders EPDM rubber as per NES 170. Crossection size 300mmx300mm. Length of fenders varies between 450 mm to 1000 mm.
030 Key Fender Head & Stern fenders All key fenders to be removed, inspected and surveyed and necessary repairs to be attended on fender securing brackets(C Channel) and associted hull fittings ,Head and stern D shaped key fenders perished/ cracked. coaming plate, securing nuts/ bolts and partition plates in between fenders corroded, thinned and holed. All fasteners to be renewed. Fastener mat : MS (d) MS Nuts and bolts - 26 mm dia, Length of bolt rod varies between 1225mm to 620 mm.
031 Tyre fenders Tyre fender damaged on P&S side , to be renwed with used aircraft tyre fenders moulded with 8 mm white natural rubber. Mat- Rubber, colour-white . No painting or coating of any other form will be permitted. Vendors to adhere sow (a) OD 750mm; ID 400mm width of tyre- 360 mm
037 Tyre fenders Tyre fender damaged on P&S side , to be renwed with used aircraft tyre fenders moulded with 8 mm white natural rubber. Mat- Rubber, colour-white . No painting or coating of any other form will be permitted. Vendors to adhere sow (b) Securing chains: 16 mm dia
031 Tyre fenders Tyre fender damaged on P&S side , to be renwed with used aircraft tyre fenders moulded with 8 mm white natural rubber. Mat- Rubber, colour-white . No painting or coating of any other form will be permitted. Vendors to adhere sow (c) Shackles 16 mm dia
031 Tyre fenders Tyre fender damaged on P&S side , to be renwed with used aircraft tyre fenders moulded with 8 mm white natural rubber. Mat- Rubber, colour-white . No painting or coating of any other form will be permitted. Vendors to adhere sow (d) Securing Brackets of Tyre Fenders damaged / detoriartyed to be renewed
031 Tyre fenders Tyre fender damaged on P&S side , to be renwed with used aircraft tyre fenders moulded with 8 mm white natural rubber. Mat- Rubber, colour-white . No painting or coating of any other form will be permitted. Vendors to adhere sow (e) Tyre fenders , OD- 1000 MM, ID 800 MM for fwd and aft . Width-350 mm
032 Under water fenders (a) Fabrication of C Channel and fitment (as per enclosed drawings) on u/w hull for securing of u/w rubber fenders, size of the C Channels 1000 X 270 X 100 mm , mat-ms size 10 mm, (As necessary) (cost including cutting and positioning / shaping of and welding of brackets as per drawing ) Note : removal and refitment of panneling / lagging in the way to facilitate hot work for welding of brackets are to consider by the firm and cost including the same
032 Under water fenders (b) Fenders to be fitted in Black colour below water line and Above water line with-white colour. Specification - EPDM rubber as per NES 170, D fenders as per enclosed drawing. Fenders is to be fitted as per user requirment .
032 Underwater fenders securing arrangment (c) Fenders is to be secured with proper nut, bolt and washers as per sample. (Mat - MS with nickel coating), Nut & Bolt Dia -20 mm, bolt Length-370 mm, Washer dia-22mm) (Note : QUOTE FOR NUTS BOLTS AND ASSOCIATED ACCESSORIES also)
033 Bulwark coaming Bulwark coaming coaming plate corroded and thinned. To be included in hull in survey and renew as per survey report. To be quoted under steel renewal. (a) Bulwark area
033 Bulwark coaming Bulwark coaming pipes corroded and thinned. To be included in hull in survey and renew as per survey report. To be quoted under steel renewal. (b) Pipe On Bulwark
033 Bulwark coaming (c) Frames deformed at various locations on weather deck including bulwark frames
034 Anchor and chain cable Anchor and Anchor chain cable. Anchor and Anchor chain cable and associated fittings are to be mechanically cleaned, eased for free movement, hydro jet blast chain cable to bare metal, paint with black bituminous paint post survey IAW NO 07/11 and refit back. Renew off all such parts which declared unservicebile & prove load test and submit load test certificate to CoY office. note : -The job involves removal of all anchor accessories, laying out and hydro jet blasting for survey and painting and final refitment post survey by ND (V) (a) Chain cable
034 Anchor and chain cable Anchor and Anchor chain cable. Anchor and Anchor chain cable and associated fittings are to be mechanically cleaned, eased for free movement, hydro jet blast chain cable to bare metal, paint with black bituminous paint post survey IAW NO 07/11 and refit back. Renew off all such parts which declared unservicebile & prove load test and submit load test certificate to CoY office. note : -The job involves removal of all anchor accessories, laying out and hydro jet blasting for survey and painting and final refitment post survey by ND (V) (b) Swivel piece
034 Anchor and chain cable Anchor and Anchor chain cable. Anchor and Anchor chain cable and associated fittings are to be mechanically cleaned, eased for free movement, hydro jet blast chain cable to bare metal, paint with black bituminous paint post survey IAW NO 07/11 and refit back. Renew off all such parts which declared unservicebile & prove load test and submit load test certificate to CoY office. note : -The job involves removal of all anchor accessories, laying out and hydro jet blasting for survey and painting and final refitment post survey by ND (V) (c) Lug less joining shackles
034 Anchor and chain cable Anchor and Anchor chain cable. Anchor and Anchor chain cable and associated fittings are to be mechanically cleaned, eased for free movement, hydro jet blast chain cable to bare metal, paint with black bituminous paint post survey IAW NO 07/11 and refit back. Renew off all such parts which declared unservicebile & prove load test and submit load test certificate to CoY office. note : -The job involves removal of all anchor accessories, laying out and hydro jet blasting for survey and painting and final refitment post survey by ND (V) (d) Stopper/Compressor
034 Anchor and chain cable Anchor and Anchor chain cable. Anchor and Anchor chain cable and associated fittings are to be mechanically cleaned, eased for free movement, hydro jet blast chain cable to bare metal, paint with black bituminous paint post survey IAW NO 07/11 and refit back. Renew off all such parts which declared unservicebile & prove load test and submit load test certificate to CoY office. note : -The job involves removal of all anchor accessories, laying out and hydro jet blasting for survey and painting and final refitment post survey by ND (V) (e) Anchors including spare anchor
035 Anchor windlass Overhaul Anchor windlass , prove for satisfactory operation. Note :- Overhaul involves removal of drum,gearbox, renewal of brake lining, OH of motor and ovrhaul of all these items and refitment.
036 Capstan Overhaul Q- deck capstan and prove for satisfactory operation. Dia 400 mm note :- Overhaul involves removal of drum,gearbox, renewal of brake lining, OH of motor and ovrhaul of all these items and refitment.
037 Single bollards (a) Single bollards corroded, thinned and holed. To be renewed as per survey report.Details :- Size of pipe: 280mm diax1200 mm Height. Doubler plate of dia 300mm and 10mm thick, dummy plate of 300mm dia and 12mm thick, supporting bracket of bollard pipe of 380mmx360mmx10mm. Tripping bracket of size 250mmx150mm and 03 no.s on each bollard.
037 Single Bollard (b) Provision of 06 in nos single bollrads on weather decks on both sides (P&S), details - Size of pipe: 300mm diax1500 mm Height. Doubler plate of dia 300mm and 10mm thick, dummy plate of 300mm dia and 12mm thick, corroded to be renewed including supporting bracket of bollard pipe of 380mmx360mmx10mm. Tripping bracket of size 250mmx150mm 03 no.s on each bollard. T bracket length of 200 mm and dia 50 mm. is to be fitted on bollard.
038 Twin Bollard Twin bollards corroded, thinned and holed, to be renewed as per survey .Details (Dia of bollard pipe: 270mm, Height of bollard: 620mm, Size of bollard base/ foundation: 1140mmx380mmx 220mm; Doubler plate size: 1240mmx500mm; side rods of bollard pipe: 520mmx40mmdia rod; Dummy plate 300mm dia x12mm thick.
039 Rubber beading Rubber beading of following wt doors , hatches,scuttles perished/cracked to be renewed and chalk test to be proved. WT door. (a) Rubber beading size: 45mmx20mm; specification as per sample)
039 Rubber beading Rubber beading of following wt doors , hatches,scuttles perished/cracked to be renewed and chalk test to be proved. (b) WT door.Operating clips to be overhauled
040 WT hatch. (a) Rubber beading size: 43mmx25mm
040 WT hatch. (b) Operating clips to be overhauled
040 WT hatch. (c) Ventilator/Sky light clips to be overhauled.
040 WT hatch. (d) Funnel ventilator clips to be overhauled.
041 WT Hatch clips 10 in no hatch clips broken / damaged. To be renewed. Mat. MS
042 WT Hatch metal coaming Metallic coaming of 05 in no WT Hatches on weather deck corroded and thinned. To be renewed as per survey report. Area - 4 Sqm.
043 Single arm davit Overhauling of Single arm davit is to be carried out, prove for satisfactory opertaion, (make and model Hemant eng mumbai). Load testing of davit to be carried out post overhauling.
044 Steel wire rope Servicibilty checks of steel wire rope is to be carried out and renewed if unserviceable and load tested upto 1.5 times of SWL.as per INBR 1552 (SWL- 1250 kgs), Submit a copy of load test to this office.
045 PIPE LINES Chemical cleanig of soil and fresh water pipe lines at various places , renewed/repaired if any defect.
046 NWT doors NWT wooden doors at various locations perished /damaged. To be renewed/repaired .
047 Ventilation Following mushroom type ventilators to be removed, cleaned/ overhauled and fitted beck. ( a) Dia: 550mm dia
047 Ventilation Following mushroom type ventilators to be removed, cleaned/ overhauled and fitted beck. (b) Dia - 360mm dia
048 Towing Hook Towing hook to be overhauled and load tested to 25 Tons . note 1 -The job involves overhaul of operating handle, steel wire rope and in way pullies.note 2 - Firm to project for load testing to CoY. Load testing will be undertaken by ND(VZG). Any defects occurred during load testing will be rectified by the firm.
049 Tanks/Manhole (a) Manholes to be renewed as per survey carried in DL No. 0002 Size of manhole: 720x520x08mm thick
049 Tanks/Manhole (b) 04 No.s Handles of 10mm dia rod and length 400mm corroded /thinned /holed to be remewd
049 Tanks/Manhole (c) Neoprene rubber joints of 720mmx520mmx06mm perished/deterioted to be renwed
049 Tanks/Manhole (d) Nuts and bolts/ studs of 16mm dia and 50mm length - 20 no.s on each manhole. Mat SS
049 Tanks/Manhole (e) Distance piece and flanges: Dia 150mm (including rubber joints)
050 Nav Light Nav light foundation (Port & Stbd) corroded, to be renewed. Size: 620mmx620mmx300mm and thickness 6mm, Mat MS
051 Drainage System (a) Deck Drain pipes corroded/ holed, to be renewed. Dia 2 1/2 inch. Mat: GI note : Pipes / fittings should be secured with rubber packings and clamps uniformly
051 Drainage System (b) Scupper with coaming of drain pipe ( leading from 01 deck to No. 1 deck and bridge top to platform deck corroded/ thinned, to be renewed. Size: 250mmx200mm
051 Drainage System (c ) Deck drain pieces on upper deck corroded, to be renewed. Dia 2 1/2 inch, each of length 01Mtr. note-The job involves removal/renewal and fitment of pipes/ panelling/ lagging/ trunking in the way.
051 Drainage System (d) 4" Soil pipes of Crew, ED's and Master's bathroom to be removed chemically cleaned and fit back.
051 Drainage System (e) Repair of 4" soil pipes to be carried out
052 Extinguishers Provision of following extinguishers at various places. (a) 9 Ltr AFFF extinguisher
052 Extinguishers Provision of following extinguishers at varios places (b) 2 Kg CO2 Extinguisher
052 Extinguishers Provision of following extinguishers. (c) 10 Kg DCP extinguisher
052 Extinguishers Provision of followingff hoses at varios places (d) Fire hoses
053 Foam solution Supply of Type 3% AFFF concentrate for forming mechanical foam
054 Deck covering Deck underlay (Macrotech) to be preiared/ renewed at uprooted/ damaged/ steel renewed, accommodation areas, Wheel house and bathrooms. (a) Surface preparation and application of EROP. And Mass 98.
054 Deck covering Deck underlay (Macrotech) to be preiared/ renewed at uprooted/ damaged/ steel renewed, accommodation areas, Wheel house and bathrooms (b) Surface preparation to be carried out by buffing on Mass 98 and application of Mass 96.
054 Deck covering Deck underlay (Macrotech) to be preiared/ renewed at uprooted/ damaged/ steel renewed, accommodation areas, Wheel house and bathrooms (c) Surface preparation and application of sealer coat on entire area
055 Chairs Chairs in bridge and master/crew cabin damaged/ broken/ including cushion & roller wheels Chairs is to be replaced with roller chairs. As per sample.
056 Lifebuoy (a) Lifebuoys to be painted as per sample including lettering and symbols. Size: 300mmx100mmx06mm
056 Lifebuoy (b) Realocating of lifebuoy frames on wheel house bulkheads (P &S).
057 Life raft roller beam Life raft roller beams leading from weatherdeck to life raft deck corroded/thinned/holed. To be repaired/renewed. Mat- ms pipe, dia of the pipe- 10 cm
058 Liferraft securing Stand Securing stand of Life rafts perished and damaged. To be renewed alongwith rubber lining and supporting frame, including fitment of HRG Mat-DMR 249 A , Thickness- 06mm.
059 Awnings Realocating of Existing Awning Shade frame of Gi pipes and fittment of the same on foxle area of the vessel on superstructure buklhead for smoth function for draining out of accumlated water : 3m x 6 m approx. Mat: GI pipes including Awning mat-PVC.
060 Name board Tug name board persihed/damaged , to be repaired /renewed , wherever required (a) Vessel iluminating board-01,
060 Name board Tug name board persihed/damaged , to be repaired /renewed , wherever required (b) Vessel name board- 02 including electopalting
060 Name board (c) Word letter of tug name on bulwark perished at fwd and stern , to be repaired/renewed, whererever required, tug name is to be painted with flourocent paint.
061 Door locks Mortise lock of non wt door defectice at various locations , All defective moritse locks to be renewed.
062 Locking arrangment Locking arrangement is to be provided in all the wt doors at various locations including hasp and staple arrangment
063 Sunmica Deck head sunmica damaged at various locations , to be repaired/renewed
064 MFMB lagging Degutting/reguttng of Mfmb lagging at accomodation area,wheel house to be carried out.
065 Sanitry system SS Wash basin, corroded/thinned/holed to be repaired/renewed. (a) Wash basin Note:- Quoted repair cost shall include cost all items.
065 Sanitry system wc of crew and master cabin corroded/thinned/holed to be repaired/renewed (b) .wc commode Note:- Quoted repair cost shall include cost all items.
065 Sanitry system wash basin including drain pipes of crew and master cabin corroded/thinned/holed to be repaired/renewed (c) wash basin including drain pipes Note:- Quoted repair cost shall include cost all items.
065 Sanitry system (d)SS tap: 1/2 inch damaged to be renewed. Note:- Quoted repair cost shall include cost all items.
065 Sanitry system (e).Supply pipes deformed to be renewed. Mat : Cu-Ni, dia: ½‟‟ Note:- Quoted repair cost shall include cost all items
065 Sanitry system (f) Drain pipe: Mat-MS,dia- 2‟‟ to be renewed. Note:- Quoted repair cost shall include cost all items
065 Sanitry system (g) Flush valves - Mat - Brass, Dia - 2" to be removed , eased out and fitted back Note:- Quoted repair cost shall include cost all items
065 Sanitry system (h) Mirror as per sample to be renewed. Note:- Quoted repair cost shall include cost all items
065 Sanitry system (j) SS stop cock 1’’ to be renewed. Note:- Quoted repair cost shall include cost all items
065 Sanitry system (k) Fw pipe lines to be renewed. (Dia. 1 inch) (Mat - CuNi) Note:- Quoted repair cost shall include cost all items
065 Sanitry system (l) Shower head including bath fittings to be renewed. Note:- Quoted repair cost shall include cost all items
066 Foot step Foot step on foxle near bollard corroded/thinned/holed, including foundations , to be renewed/repairerd, as per survey repert, mat- Al chequerd plate.
067 Panelling panelling in living spaces/whell house and other areas , damaged at varios locations , to be renewed/repaired. (Mat-Wood)
068 Kit Lockers Kit lockers in crew cabin and master cabin damaged to ber renewed/ repaired, (mat-CRCA)
069 Ladder Ladders to be manufactureda and welded on bulwark at stem , (Mat-MS) (Length- 2mtr) (Width- 0.5mtr)
070 Mast winch Mast winch jammed , to be eased including all in ways pulleys
071 Fisherman Plate Corroded/Thin/holed , to be renewed Mat-MS (a) Fish plate size: 20x20 inch, 10mm thickness
071 Fisherman Plate Corroded/Thin/holed , to be renewed Mat-MS ( b) Doubler plate size:28x28inch, 10 mm thickness
071 Fisherman Plate Corroded/Thin/holed , to be renewed Mat-MS (c) Angle bar 3 x1.5 inch
072 Butterfly nut SS butterfly nuts and tumbler bolt of engine room sky light &exhaust flaps broken. To be renewed. Dia of bolt : 20 mm & 6 inch length (Mat-SS) including rubber beading . Rmt-4 rmt
073 Guard rail Guard rails on 01 & 02 deck (Port side) corroded/perished . To be repaired/renewed. (Mat-GI Pipe) Dia of guard rail pipe:1 ¾’’,
074 Stanchions Stanchions on 01 & 02 deck (Port side) corroded/perished . To be repaired/renewed. (Mat-GI Pipe) Dia of stanchions pipe : 1.5" dia Pipe, 1Mtr length each
075 Non WT door Non water tight door of bridge and living spaces damaged including frames, to be repaired/renewed.
076 Mob marker MOB marker stand on (p&s) damaged . To be renewed/repaired.
077 Ventilation Wire mesh of all air vent corroded/perished. To be renewed.
078 Remote oprating valve Remote operating valve of fore peak tank, jammed , to be repaired and operation proven.
079 Rubber beading Rubber beading of vent openings and goose neck deteriorated. To be renewed.
080 Supporting frames Supporting frames of bulwark on (P&S) side buckled. To be repaired/renewed. Mat-MS . To be repaired as per Hull survey report
081 Vent flaps Vent flaps deformed on A bracket, to be renewed
082 Bulwark doors Bulwarks doors including hand rails on weather deck jammed /dented/damaged. To be renewed/ repaired.
083 Cleats MS cleats on (p&s) bulwark damaged, to be renewed as per sample
084 Boxes (a) Fire hoses securing boxes and its glass damaged at various locations , to be renewed/repaired
084 Boxes (b) Boxes of variuos control panel corroded/thinned/holed at varios locations, to be renewed as per existing as fitted sample. (Mat-MS)
085 Woodeen cup board Wooden lockers damaged at various locations to be repaired/renewed
086 Sofa Sofa cushion torned in ED ,Master and crew rest room , to be renewed.
087 Panneling SS panneling at indicated locations damged to be renewed.
088 Water Purifier Provision Of Drinking Water Purifier of 9 Ltr Capacity For Domestic Use In Galley And Crew Dinning Hall. Work Also Involves Fitment, Piping Arrangement And Commissioning Of The System. –With 02 Set Of Spares Including Filter And Membrane. Work Includes Provisioning Of Following Spares Also :- (a) RO Membrane Welded -02 , (b) RO Membrane High Flow-02 (c) Inline Carbon filter-02 ,(d) Inline Sediment Filter- 02 , (e) Activated Carbon Filter (Excel Elite) , (f) Post Carbon Filter-02
089 Water Cooler Serviceability checks of water cooler in crew dining hall is to be carried out.capacity-20 ltr
090 Fixed H2s Sensor Provision of Fixed H2S sensors in the vicinity of STP compartment. (OEM - Hi-Point Services Pvt. Ltd.) Including installation of sensors and control pannel. Note:- Trial report along with H2S sensors calibration certificate by OEM to be submitted.
091 Portable H2S Sensors. Provision of Portable H2S sensors . (OEM - Hi-Point Services Pvt. Ltd.) Note:- Trial report alongwith H2S sensors calibration certificate by OEM to be submitted.
092 Bunk Bunk in crew rest room / master room damaged to be repaired
093 Panelling panelling in living spaces/whell house and other areas , damaged at varios locations , to be renewed/repaired. Mat Sunmica
ENGINEERING WORK PACKAGE CLASS AUTHORITY : IRS NOTE : ALL DEFECTS RELATED TO SR-19 OF TUG SAHAYAK WILL BE UNDER SUPERVISION OF IRS. 1001 EQPT:FIRE/BILGE PUMP MAKE : BE PUMPS,TYPE-CETRIFUGAL SELF PRIMING MOTOR DRIVEN, MODEL- MA843KKS-6-316-MS3, CAP: 30 CMH
1001 EQPT:FIRE/BILGE PUMP (1) Carry out overhauling of Pump as per maker's instruction manual. (a) Dismantle pump completely. (b) Examine all parts for wear & tear,renew worned out parts (c) Renew Mechanical seal & bearings.
1001 EQPT:FIRE/BILGE PUMP (2) Suction and discharge pressure gauges to be calibrated. range 0-120 psi and 30”-30psi and renewed with (Glecerin filled)
1001 EQPT:FIRE/BILGE PUMP (3) Renew Instrumentation gauge pipes with suitable end fittings . mat: CuNi dia:1/4” ( If required)
1001 EQPT:FIRE/BILGE PUMP (4) Rectify lekages in self priming unit ,renew flexible hoses if required size 15mm
1001 EQPT:FIRE/BILGE PUMP (5) Renew three jaw coupling & rubber spider coupling between pump & motor.
1001 EQPT:FIRE/BILGE PUMP (6) Coupling/Belt Guard to be renewed / Manufactured, If perished.
1001 EQPT:FIRE/BILGE PUMP (7) Carry out alignment of pump with motor and prove for satisfactory performance with general Fire & bilge system.
1002 EQPT: GS PUMP MAKE : BE PUMPS,TYPE-CETRIFUGAL SELF PRIMING MOTOR DRIVEN, MODEL- MA843KKS-6-316-MS3, CAP: 35CMH
1002 EQPT: GS PUMP (1) Carry out overhauling of Pump as per maker's instruction manual. (a) Dismantle pump completely. (b) Examine all parts for wear & tear,renew worned out parts (c) Renew Mechanical seal & bearings.
1002 EQPT: GS PUMP (2) Suction and discharge pressure gauges to be calibrated. range 0-120 psi and 30”-30psi and renewed with (Glecerin filled)
1002 EQPT: GS PUMP (3) Renew Instrumentation gauge pipes with suitable end fittings . mat: CuNi dia:1/4” ( If required)
1002 EQPT: GS PUMP (4) Rectify lekages in self priming unit ,renew flexible hoses if required size 15mm
1002 EQPT: GS PUMP (5) Renew three jaw coupling & rubber spider coupling between pump & motor.
1002 EQPT: GS PUMP (6) Coupling/Belt Guard to be renewed / Manufactured, If perished.
1002 EQPT: GS PUMP (7) Carry out alignment of pump with motor and prove for satisfactory performance with general Fire & bilge system.
1003 EQPT: VOITH COOLING WATER PUMPS MAKE: BEST&CROMPTON PUMPS, TYPE-CETRIFUGAL MOTOR DRIVEN,MODEL-CNW 100-200 (FIRM NOT TO QUOTE) MAKE: BEST&CROMPTON PUMPS, TYPE-CETRIFUGAL MOTOR DRIVEN,MODEL-CNW 100-200
1003 EQPT: VOITH COOLING WATER PUMPS (1) Carry out overhauling of Pump as per maker's instruction manual. (a) Dismantle pump completely. (b) Examine all parts for wear & tear,renew worned out parts (c) Renew Mechanical seal & bearings.
1003 EQPT: VOITH COOLING WATER PUMPS (2) Suction and discharge pressure gauges to be calibrated. range 0-120 psi and 30”-30psi and renewed . (Glecerin filled gauges)
1003 EQPT: VOITH COOLING WATER PUMPS (3) Renew Instrumentation gauge pipes with suitable end fittings . mat: CuNi dia:1/4” ( If required)
1003 EQPT: VOITH COOLING WATER PUMPS (4) Rectify lekages in self priming unit ,renew flexible hoses if required size 15mm
1003 EQPT: VOITH COOLING WATER PUMPS (5) Renew three jaw coupling & rubber spider coupling between pump & motor.
1003 EQPT: VOITH COOLING WATER PUMPS (6) Coupling/Belt Guard to be renewed / Manufactured, If perished.
1003 EQPT: VOITH COOLING WATER PUMPS (7) Carry out alignment of pump with motor and prove for satisfactory performance with general Fire & bilge system.
1004 EQPT: DOMESTIC FRESH WATER PUMPS MAKE: BE PUMPS, TYPE-CETRIFUGAL SELF PRIMING MOTOR DRIVEN,MODEL- A01210K-1B-304-WCF-MS3, Cap: 1 CMH
1004 EQPT: DOMESTIC FRESH WATER PUMPS (1) Carry out overhauling of Pump as per maker's instruction manual. (a) Dismantle pump completely. (b) Examine all parts for wear & tear,renew worned out parts (c) Renew Mechanical seal & bearings.
1004 EQPT: DOMESTIC FRESH WATER PUMPS (2) Suction and discharge pressure gauges to be calibrated. range 0-120 psi and 30”-30psi and renewed with (Glecerin filled)
1004 EQPT: DOMESTIC FRESH WATER PUMPS (3) Renew Instrumentation gauge pipes with suitable end fittings . mat: CuNi dia:1/4” ( If required)
1004 EQPT: DOMESTIC FRESH WATER PUMPS (4) Rectify lekages in self priming unit ,renew flexible hoses if required size 15mm
1004 EQPT: DOMESTIC FRESH WATER PUMPS (5) Renew three jaw coupling & rubber spider coupling between pump & motor.
1004 EQPT: DOMESTIC FRESH WATER PUMPS (6) Coupling/Belt Guard to be renewed / Manufactured, If perished.
1004 EQPT: DOMESTIC FRESH WATER PUMPS (7) Carry out alignment of pump with motor and prove for satisfactory performance with general Fire & bilge system.
1005 EQPT: SALVAGE PUMP MAKE: BEST & CROMPTON, MODEL- BWL 1525,TYPE: CENTIFUGAL, SELF PRIMING ENGINE DRIVEN,Cap: 200 CMH
1005 EQPT: SALVAGE PUMP (1) Carry out overhauling of Pump and renew parts if equired:-Dismantle pump completely. Examine all parts for wear. Renew shaft, impeller, mechanical seal, bearing, bearing bracket, bearing bushes, shaft sleeve, keys, gaskets, rubber bellow, where applicable.
1005 EQPT: SALVAGE PUMP (2) Renew coupling pads, mechanical seal, bearings, grease cups,and worn out parts.
1005 EQPT: SALVAGE PUMP (3) Suction and discharge pressure gauges(Glecerin filled) to be renewed. Range 30”-0” & 0-100psi
1005 EQPT: SALVAGE PUMP (4) Instrumentation gauges pipes with suitable end fittings to be renewed. mat: CuNi dia:1/4”
1005 EQPT: SALVAGE PUMP (5) Coupling Guard to be renewed / Manufactured
1005 EQPT: SALVAGE PUMP (6) Carry out alignment of pump with motor and Pump to be proved for satisfactory performance post work completion..
1006 EQPT : FUEL OIL TRANSFER PUMP MAKE : RAYSONS, MODEL-RGP 2 MT ,TYPE: ROTARY GEAR PUMP, CAP: 02 CMH
1006 EQPT : FUEL OIL TRANSFER PUMP (1) Carry out overhauling of Pump and renew parts if equired:-Dismantle pump completely. Examine all parts for wear. Renew shaft, Drive and idler Gears, mechanical seal, bearing, bearing bracketr, bearing bushes, shaft sleeve, keys, gaskets etc.
1006 EQPT : FUEL OIL TRANSFER PUMP (2) Suction and discharge pressure gauges(Glecerin filled) to be renewed if declared BER. range 30”-0” and 0-07 bar
1006 EQPT : FUEL OIL TRANSFER PUMP (3) Overhaul & reset relief valve.(set pr.-5Kg/cm2)
1006 EQPT : FUEL OIL TRANSFER PUMP (4) Coupling Guard to be renewed / Manufactured if required.
(5) Instrumentation gauges pipes with suitable end fittings to be renewed. if required. mat: CuNi dia:1/4”
1006 EQPT : FUEL OIL TRANSFER PUMP (6) Carry out alignment of pump with motor andPump to be proved for satisfactory performance post work completion.
1007 EQPT : EXTERNAL FIRE FIGHTING PUMP MAKE : JASON ENGINEERING AS, POWER CONSUMPTION 772 KW, PUMP, CAP: 1500 CMH
1007 EQPT : EXTERNAL FIRE FIGHTING PUMP (1) Carry out overhauling of Pump and renew parts if equired:-Dismantle pump completely. Examine all parts for wear. Renew shaft, impeller, mechanical seal, bearing, bearing bracket, bearing bushes, shaft sleeve, keys, gaskets, rubber bellow, where applicable.
1007 EQPT : EXTERNAL FIRE FIGHTING PUMP (2) Renew coupling pads, mechanical seal, bearings, grease cups,and worn out parts.
1007 EQPT : EXTERNAL FIRE FIGHTING PUMP (3) Suction and discharge pressure gauges(Glecerin filled) to be renewed. Range 30”-0” & 0-100psi
1007 EQPT : EXTERNAL FIRE FIGHTING PUMP (4) Instrumentation gauges pipes with suitable end fittings to be renewed. mat: CuNi dia:1/4”
1007 EQPT : EXTERNAL FIRE FIGHTING PUMP (5) Coupling Guard to be renewed / Manufactured
1007 (a) EQPT : FIFI PUMP POWER TAKE OFF ASSEMBLY PUMPS : EUREKA PUMPS 250X350 DGF, MODEL DF A6468-000, 182.02, 45TMB1480958 REDUCTION GEAR BOX: MAKE - JASON ENGG, MODEL - 255VK-1.12-CCW-02, SL NO-1881-56-11
1007 (a) EQPT : FIFI PUMP POWER TAKE OFF ASSEMBLY (1) Check and inspection the gear mechanism/tooth of gear box.
1007 (a) EQPT : FIFI PUMP POWER TAKE OFF ASSEMBLY (2)Check and inspection bearings of gear box.if found defective to be Replaced.
1007 (a) EQPT : FIFI PUMP POWER TAKE OFF ASSEMBLYCheck the perfomance of clutch-in & declutch mechanism with pneumatic valves.
1007 (a) EQPT : FIFI PUMP POWER TAKE OFF ASSEMBLY (3)Renew gear box oil with fresh oil. HP 90. ( supplied by Firm)
1007 (a) EQPT : FIFI PUMP POWER TAKE OFF ASSEMBLY (4)Carry out alignment of pump with power take off assembly & engine.
1007 (a) EQPT : FIFI PUMP POWER TAKE OFF ASSEMBLY (5)Pump to be proved for satisfactory perfomance post work completion.
1008 EQPT: PORTABLE SUBMERSIBLE BILGE / FIRE PUMPS MAKE : MODI INDUSTRIES (FC), Model- M-120 NM,,Capacity- 20 TPH
1008 EQPT: PORTABLE SUBMERSIBLE BILGE / FIRE PUMPS (1) Submersible pump to be overhauled, and Pump to be proved for satisfactory performance post work completion.
1008 EQPT: PORTABLE SUBMERSIBLE BILGE / FIRE PUMPS (2) If declared BER , to be procured and provided for stand by / Emergency pumping out of bilge systems(with hoses, dia-100 mm, length- 25 meter).
1009 EQPT: PORTABLE NON SUBMERSIBLE PUMPS MAKE : MODI INDUSTRIES (FC), DIESEL ENGINE DRIVEN Model- DC-8Y-DE,,Capacity- 37 TPH
1009 EQPT: PORTABLE NON SUBMERSIBLE PUMPS (1) Non Submersible pump to be overhauled including its engine part, Pump to be proved for satisfactory performance post work completion. ,
1010 EQPT: PORTABLE SUBMERSIBLE SALVAGE PUMPS MAKE : MODI INDUSTRIES (FC), Model- M-504 NM,,Capacity- 40 TPH
1010 EQPT: PORTABLE SUBMERSIBLE SALVAGE PUMPS (1) Pumps to be overhauled,Pump to be proved for satisfactory performance post work completion. if declared BER , to be procured and provided for stand by / Emergency pumping out of bilge systems(with hoses, dia-100 mm, length- 25 meter).
1011 EQPT: PORTABLE SUBMERSIBLE FIRE PUMP MAKE : MODI INDUSTRIES (FC), Model- M-554 NT,,Capacity- 100 TPH
1011 EQPT: PORTABLE SUBMERSIBLE FIRE PUMP (1) Submersible pump to be overhauled, Pump to be proved for satisfactory performance post work completion.
1012 EQPT: HAND PUMPS (E/R Bilge,FO,LO,FW,Forward Bilge) ( All pumps are Hard to Operate) MAKE: M/S WESTINDIA TRADERS
1012 EQPT: HAND PUMPS (1) Dismantle and Clean pumps internally, renew wear down parts if required.
1012 EQPT: HAND PUMPS (2) Renew Wooden handles of all pumps.
1012 EQPT: HAND PUMPS (3) Pump to be boxed back and proved for satisfactory performance.
1012 EQPT: HAND PUMPS (4) Pump Suction cocks to be overhauled
1013 EQPT: DD COMPRESSOR ENGINE MAKE: HATZ DIESEL, MODEL- IB20
1013 EQPT: DD COMPRESSOR ENGINE (1) Renew injector nozzle and calibrate Injector .
1013 EQPT: DD COMPRESSOR ENGINE (2) Calibrate FIP and governor assembly .
1013 EQPT: DD COMPRESSOR ENGINE (3) Drain Lub oil sump, Clean and charge with new oil supplied.
1013 EQPT: DD COMPRESSOR ENGINE (4) Renew air filter element, fuel filter element, and lub oil filter element.
1013 EQPT: DD COMPRESSOR ENGINE (5) Renew piston rings.
1013 EQPT: DD COMPRESSOR ENGINE (6) Renew Exhaust silencers.
1013 EQPT: DD COMPRESSOR ENGINE (7) Chemical Cleaning of exhaust line.and renew insulation/lagging of the exhaust pipe.
1013 EQPT: DD COMPRESSOR ENGINE (8) Securing clamp of exhaust trunking.
1013 EQPT: DD COMPRESSOR ENGINE (9) Engine to be proved for satisfactory performance along with compressor post work completion.
1014 EQPT: AIR COMPRESSOR, MAKE : ATLAS COPCO MODEL-LT5-60KE (Main compressor),LT- 3-60Khe(DD compressor), TYPE: 2 STAGE RECIPROCATING TYPE,CAPACITY:- 12.4 CMH at 30 Bar Complete overhaul of compressors to be carried out including following jobs :-
1014 EQPT: AIR COMPRESSOR (1) Inspect both big end and small end bearings of connecting rod . Renew if recommended by QC.
1014 EQPT: AIR COMPRESSOR , (2) Lub oil sump to be drained, Cleaned, renew the sight glass if required. and new oil to be charged in sump.(lub oil will be provided by the Navy)
1014 EQPT: AIR COMPRESSOR (3) Piston rings to be renewed
1014 EQPT: AIR COMPRESSOR (4) Luboil pressure gauge (glycerin filled) to be renewed.(0-100 psi)
1014 EQPT: AIR COMPRESSOR (5) Air inlet filter element of compressor to be renewed
1014 EQPT: AIR COMPRESSOR (6) Instrumentation gauges pipes with suitable end fittings to be renewed mat: CuNi dia:1/4”
1014 EQPT: AIR COMPRESSOR (7) Suction and discharge pressure gauges(Glycerin filled) to be renewed. range 0-10 bar and 0-50 bar
1014 EQPT: AIR COMPRESSOR (8) Pressure switches to be calibrated (cut in 15 and cut out at 30 bar).if found defective same to be renewed.
1014 EQPT: AIR COMPRESSOR (9) Oil separator of compressors to be Cleaned.
1014 EQPT: AIR COMPRESSOR (10) Chemical Cleaning and pressure testing of air bottles to be carried out capacity: 500ltrs TP: 45 bar
1014 EQPT: AIR COMPRESSOR (11) Relief valves on air bottles to be set to 48 bar. Clibrate the same.Renew if required.
1014 EQPT: AIR COMPRESSOR (12) Renew air system cocks(dia 20mm)
1014 EQPT: AIR COMPRESSOR (13) Lub oil pressure gauge to be renewed.range 0-4kg/cm2
1014 EQPT: AIR COMPRESSOR (14) Survey the condition of the foundation, renew if recommended by QC.
1014 EQPT: AIR COMPRESSOR (15) Coupling/Belt Guard to be renewed / Manufactured if required.
1014 EQPT: AIR COMPRESSOR (16) Check condition of shock and vibration mountings. Replace if necessary as per OEM specs.
1014 EQPT: AIR COMPRESSOR (17) Pressure test of the valves, renew if required Sea chest blow through isolating valve 12mm Ø globe
1014 EQPT: AIR COMPRESSOR (18) Pressure test of the valves, renew if required Shore supply isolating valve 40mm Ø globe
1014 EQPT: AIR COMPRESSOR (19) Pressure test of the valves, renew if required "Air to general usage" valves 12mm Ø globe
1014 EQPT: AIR COMPRESSOR (19 a) " Air to sea chest main isolating valve" 30mm Ø globe
1014 EQPT: AIR COMPRESSOR (20) Pressure test of the valves, renew if required Main Engine Air system relief valve. set pressure : 15 bar
1014 EQPT: AIR COMPRESSOR (21) Pressure test of the valves, renew if required Main engine air Starting system reducer 40mm Ø, SP : 10 bar
1014 EQPT: AIR COMPRESSOR ,(22) Pressure test of the valves, renew if required -Air bottles outlet to main engines 40mm Ø globe
1014 EQPT: AIR COMPRESSOR (23) Pressure test of the valves, renew if required Compressor to be boxed back and carry out capacity trials of compressor.
1015 EQPT/SYSTEM: SEWAGE TREATMENT PLANT MAKE/MODEL: M/S Wartsila Hamworthy, STA-2C, Cap 27 Persons Note : Firms to quote after on sight inspection of equipment / plant, complete STP system to be overhauled and proved, including all components, Pumps, compressor, all valves, guages, strainers, filters and renew all components declared BER, all tanks, system pipes to be cleaned, all chemicals / catalists to be charged amd complete system to be proved on completion of work
1015 EQPT/SYSTEM: SEWAGE TREATMENT PLANT (1) Surge tanks to be chemically Cleaned
1015 EQPT/SYSTEM: SEWAGE TREATMENT PLANT (2) Portable Compressor to be overhauled.
1015 EQPT/SYSTEM: SEWAGE TREATMENT PLANT (3) Overboard pump to be overhauled.
1015 EQPT/SYSTEM: SEWAGE TREATMENT PLANT (4) Ventury to be dismantled Cleaned internally and boxed back
1015 EQPT/SYSTEM: SEWAGE TREATMENT PLANT (5) Inline strainer to be dismantled and strainer element to be renewed
1015 EQPT/SYSTEM: SEWAGE TREATMENT PLANT (6) Air filter element to be renewed.
1015 EQPT/SYSTEM: SEWAGE TREATMENT PLANT (7) Air regulator to be dismantled Cleaned and boxed up and set pressure to be set at range 1-150 psi
1015 EQPT/SYSTEM: SEWAGE TREATMENT PLANT (8) Electro catalytic cell to be dismantled and acid Cleaned using 6%-10% solution of water and muriatic acid.
1015 EQPT/SYSTEM: SEWAGE TREATMENT PLANT (9) All flexible hoses to be renewed
1015 EQPT/SYSTEM: SEWAGE TREATMENT PLANT (10) Complete assembly and system pipe to be painted post work completion as per color code.
1016 EQPT: HARBOUR DIESEL GENERATOR, MAKE: M/s KOEL ,MODEL: 4R1040T, 50 KVA (i) 1000 hourly routine is to be carried out on DG inclunding following jobs.
1016 EQPT: HARBOUR DIESEL GENERATOR, (1) Carry out visual examination of engine for Cleanliness and leakages if any, rectify them.
1016 EQPT: HARBOUR DIESEL GENERATOR, (2) Replace all v belts
1016 EQPT: HARBOUR DIESEL GENERATOR, (3) Check valve clearance and adjust if reqd.
1016 EQPT: HARBOUR DIESEL GENERATOR, (4) Check turbo charger for abnormal sound if any.
1016 EQPT: HARBOUR DIESEL GENERATOR, (5) Change centrifuge filter and Replace it with sealing kit.
1016 EQPT: HARBOUR DIESEL GENERATOR, (6)Change engine oil.
1016 EQPT: HARBOUR DIESEL GENERATOR, (7) Replace duplex lube oil filters.
1016 EQPT: HARBOUR DIESEL GENERATOR, (8) Replace element of dry type air filter.
1016 EQPT: HARBOUR DIESEL GENERATOR, (9) Replace duplex fuel filters
1016 EQPT: HARBOUR DIESEL GENERATOR, (10) Change joint of rocker cover
1016 EQPT: HARBOUR DIESEL GENERATOR, (11) Coolant to be tooped up
1016 EQPT: HARBOUR DIESEL GENERATOR, (12) carry out perfomance trial post work completion.
1017 EQPT:DIESEL GENERATOR, (1) Carry out visual examination of engine for Cleanliness and leakages if any.Rectify them.
1017 EQPT:DIESEL GENERATOR (2)Check the valve clearance & adjust if required.
1017 EQPT:DIESEL GENERATOR, (3)Clean sea water strainer.
1017 EQPT:DIESEL GENERATOR, (4)Clean the heat exChanger internally.
1017 EQPT:DIESEL GENERATOR, (5)Clean the centrifuge filter and Replace with sealing kit.
1017 EQPT:DIESEL GENERATOR, (6) Change the engine lube oil.
1017 EQPT:DIESEL GENERATOR, (7)Replace the cartridge of duplex lube oil filter.
1017 EQPT:DIESEL GENERATOR, (8)Replace the element of dry type air Cleaner.
1017 EQPT:DIESEL GENERATOR, (9) Replace the V belts.
1017 EQPT:DIESEL GENERATOR, (10) Replace the cartridge of duplex fuel filter.
1017 EQPT:DIESEL GENERATOR, (11) Change joint of rocker cover.
1017 EQPT:DIESEL GENERATOR, (12) Top up the coolant.
1017 EQPT:DIESEL GENERATOR, (13) Replace fuel hoses.
1017 EQPT:DIESEL GENERATOR, (14) Replace wire braded hoses.
1017 EQPT:DIESEL GENERATOR, (15) Replace high pressure fuel pipes.
1017 EQPT:DIESEL GENERATOR, (16) Replace the ' o' ring of the drain plug.
1017 EQPT:DIESEL GENERATOR, (17) Replace the rubber hoses of charge air cooler inlet & outlet pipe.
1017 EQPT:DIESEL GENERATOR, (18) Clean CAC and Replace with service kit.
1017 EQPT:DIESEL GENERATOR, (19) Replace the air Cleaner hose.
1017 EQPT:DIESEL GENERATOR, (20) Disconnect the expansion bellow and Replace the joints.
1017 EQPT:DIESEL GENERATOR, (21) Disconnect the lub oil inlet pipe to turbocharger.Replace the joints.
1017 EQPT:DIESEL GENERATOR, (22) Disconnect the lube oil drain pipe to turbocharger. Replace the joint.
1017 EQPT:DIESEL GENERATOR, (23) Replace the joint of turbo charger exhaust manifold.
1017 EQPT:DIESEL GENERATOR, (24) Replace old joints of exhaust manifold.
1017 EQPT:DIESEL GENERATOR, (25) Remove the sealing rings and Replace sealing rings of ex manifold.
1017 EQPT:DIESEL GENERATOR, (26) Replace the sealing washers venting pipe of cylinder head.
1017 EQPT:DIESEL GENERATOR, (27) Replace the joint of rocker supply oil pipe banjo.
1017 EQPT:DIESEL GENERATOR, (28) Replace injector.
1017 EQPT:DIESEL GENERATOR, (29) Replace the nozzle sealing washers.
1017 EQPT:DIESEL GENERATOR, (30) Replace the cylinder head bolts if length is increased beyond limit value.
1017 EQPT:DIESEL GENERATOR, (31) Replace thermostat element
1017 EQPT:DIESEL GENERATOR, (32) Replace the joint of oil sump.
1017 EQPT:DIESEL GENERATOR, (33) Replace the joint of suction tube assembly.
1017 EQPT:DIESEL GENERATOR, (34) Replace piston rings.
1017 EQPT:DIESEL GENERATOR, (35) Replace the cylinder liner if bore has reached the wear limit.
1017 EQPT:DIESEL GENERATOR, (36) Overhaul cylinder head.
1017 EQPT:DIESEL GENERATOR, (37) Replace cylinder head gasket.
1017 EQPT:DIESEL GENERATOR, (38) Replace All inlet and exhaust valves.
1017 EQPT:DIESEL GENERATOR, (39) Replace valve guides.
1017 EQPT:DIESEL GENERATOR, (40) Replace inlet valve seat.
1017 EQPT:DIESEL GENERATOR, (41) Replace exhaust valve seat.
1017 EQPT:DIESEL GENERATOR, (42) Replace valve seals.
1017 EQPT:DIESEL GENERATOR, (43) Replace valve collets.
1017 EQPT:DIESEL GENERATOR, (44) Replace valve springs inner.
1017 EQPT:DIESEL GENERATOR, (45) Replace valve springs outer.
1017 EQPT:DIESEL GENERATOR, (46) Replace valve spring cup.
1017 EQPT:DIESEL GENERATOR, (47) Replace connecting rod bolts.
1017 EQPT:DIESEL GENERATOR, (48) Service sea water pump.
1017 EQPT:DIESEL GENERATOR, (49) Replace set of joints.
1017 EQPT:DIESEL GENERATOR, (50) Replace set of 'o' rings.
1017 EQPT:DIESEL GENERATOR, (51) Replace set of copper washers.
1017 EQPT:DIESEL GENERATOR, (52) Replacement of all the hoses.
1017 EQPT:DIESEL GENERATOR, (53) Check & caliberate engine sensors & switches and undertake safety Checks.
1017 EQPT:DIESEL GENERATOR, (54) Replace fresh water pump.
1017 EQPT:DIESEL GENERATOR, (55) Calibration of governor to be carried out
1017 EQPT:DIESEL GENERATOR, (56) Replace fuel supply and return line fuel system.
1017 EQPT:DIESEL GENERATOR, (57) Droop setting and load trials.
1017 EQPT:DIESEL GENERATOR, (58) Safety guard of S/W and FW pump drive deteriorated.to be renewed.Mat: MS,area to be protected 2 mt sq,width:100mm
1018 EQPT : VALVES Following valves to be overhauled, repaired and pressure tested. Up to 1.5 times working pressure. Job includes renewal of 10% BER valaves if any. ENGINE ROOM SEA WATER COOLING ME ,DG,VOITH, GS PUMP SYSTEMS
1018 EQPT : VALVES (1) Main Sea Chest Gate Valves, 200 mm
1018 EQPT : VALVES (2) ME cooling and Voith suction Valves, Gate vv, 100 mm
1018 EQPT : VALVES (3) Voith discharge vv,SD, 80 mm
1018 EQPT : VALVES (4) DG seawater supply and dis valves, SD, 50 mm
1018 EQPT : VALVES (5) DG overboard angle SDNR valves, 50 mm
1018 EQPT : VALVES (6) MEoverboard & angle SDNR valves, 100 mm
1018 EQPT : VALVES (7) GS pump suction chest (02) valves, SD, 65mm,
1018 EQPT : VALVES (8) GS pump Discharge vv, SSDNR, 65mm
1018 EQPT : VALVES (9) GS pump overboard vv, Angle SDNR, 65mm
1018 EQPT : VALVES (10) GS pump vv to firemain and isolating, Gate&SDNR, 65mm
1018 EQPT : VALVES (11) Engine seachest vent valves, Angle, 80mm
1018 EQPT : VALVES (12) FIREMAIN SYSTEM ,Fire hydrant valves, 65 mm
1018 EQPT : VALVES (13) FIREMAIN SYSTEM, fire hydrant chests valves
1018 EQPT : VALVES (14) FIREMAIN SYSTEM,Fire sea chest vent valves,SD, 80 m,
1018 EQPT : VALVES (15) FIREMAIN SYSTEM, Gate valves, 40 mm
1018 EQPT : VALVES (16) FIREMAIN SYSTEM, Gate valves, 65 mm
1018 EQPT : VALVES (17) FIREMAIN SYSTEM, Foam supply line valves, SD, Gate, 50 mm
1018 EQPT : VALVES (18) AIR SYSTEM, Air system cocks( bottle in and outlet), 50 mm
1018 EQPT : VALVES (19) AIR SYSTEM, Air system valves (Statring motor), 50 mm
1018 EQPT : VALVES (20) AIR SYSTEM, Air system Valves, SD, 20 mm
1018 EQPT : VALVES (21) AIR SYSTEM, Air system Valves, angle, 20 mm
1018 EQPT : VALVES (22) AIR SYSTEM, Air system relief Valves, SD, 20 mm
1018 EQPT : VALVES (23) AIR SYSTEM, Air reducer 20 mm and 40mm
1018 EQPT : VALVES (24) FUEL SYSTEM Main Quick shut off ( storage /RU tank outlet to ME/DG) valves, SD, 50 mm
1018 EQPT : VALVES (25) FUEL SYSTEM Angle vv, 32mm
1018 EQPT : VALVES (26) FUEL SYSTEM SD valves, 32mm
1018 EQPT : VALVES (27) FUEL SYSTEM Fuel seperator valves, SD, 20 mm
1018 EQPT : VALVES (28) FRESH WATER SYSTEM Suction ,discharge and filling vvs, of FW Pump,Tank and Hand pp SD, 65mm
1018 EQPT : VALVES (29) VOITH SYSTEM inlet outlet of coolers, SD, 40mm
1018 EQPT : VALVES (30) VOITH SYSTEM Overboard valves, Angle SDNR, 65mm
1019 EQPT: STRAINERS, Following system strainers to be manufactured as per sample material: brass
1019 EQPT: STRAINERS, Following system strainers to be manufactured as per sample material: brass, (1) Main sea water supply manifold strainers
1019 EQPT: STRAINERS, Following system strainers to be manufactured as per sample material: brass (2) Main engine cooling water system strainers
1019 EQPT: STRAINERS, Following system strainers to be manufactured as per sample material: brass (3) Main fire pump suction system strainers
1020 EQPT: SEA WATER COOLERS, Following sea water system coolers to be chemically Cleaned, zinc plugs to be renewed, drain plugs to be Replaced with drain cocks of same size(mat. brass)and presuure tested, renew if declared BER.
1020 EQPT: SEA WATER COOLERS, Following sea water system coolers to be chemically Cleaned, zinc plugs to be renewed, drain plugs to be Replaced with drain cocks of same size(mat. brass)and presuure tested, renew if declared BER. (1) Voith sea water coolers
1020 EQPT: SEA WATER COOLERS, Following sea water system coolers to be chemically Cleaned, zinc plugs to be renewed, drain plugs to be Replaced with drain cocks of same size(mat. brass)and presuure tested, renew if declared BER .(2) DA Sea water coolers
1020 EQPT: SEA WATER COOLERS, Following sea water system coolers to be chemically Cleaned, zinc plugs to be renewed, drain plugs to be Replaced with drain cocks of same size(mat. brass)and presuure tested, renew if declared BER. (3) FiFipump gear box lub oil Sea water coolers
1021 EQPT: SYSTEM PIPES Following sea water system pipes to be Removed chemically Cleaned, repaired, pressure tested and fitted back (Jobs includes renewal of approximately 20% of pipes if required ) Also quote for system lines along with all necessary joints etc.
1021 EQPT: SYSTEM PIPES (1) ENGINE ROOM SEA WATER COOLING ME ,DG, GS PUMP SYSTEMS 200mm Ø sea water system pipes (Mat.- CuNi)
1021 EQPT: SYSTEM PIPES (2) ENGINE ROOM SEA WATER COOLING ME ,DG, GS PUMP SYSTEMS100mm Ø sea water system pipes (Mat.- CuNi)
1021 EQPT: SYSTEM PIPES (3) ENGINE ROOM SEA WATER COOLING ME ,DG, GS PUMP SYSTEMS80mm Ø sea water system pipes (Mat.- CuNi)
1021 EQPT: SYSTEM PIPES (4) ENGINE ROOM SEA WATER COOLING ME ,DG, GS PUMP SYSTEMS60mm Ø sea water system pipes (Mat.- CuNi)
1021 EQPT: SYSTEM PIPES (5) ENGINE ROOM SEA WATER COOLING ME ,DG, GS PUMP SYSTEMS50mm Ø sea water system pipes (Mat. - CuNi)
1021 EQPT: SYSTEM PIPES (6) BILGE SYTEM 65mm Ø sea water system pipes (Mat. - CuNi)
1021 EQPT: SYSTEM PIPES (7) BILGE SYTEM 50mm Ø sea water system pipes (Mat.- CuNi)
1021 EQPT: SYSTEM PIPES (8) BILGE SYTEM 20mm Ø sea water system pipes (Mat.- CuNi)
1021 EQPT: SYSTEM PIPES (9) AIR SYSTEM 50mm Air bottles outlet pipe to main engines
1021 EQPT: SYSTEM PIPES (10) AIR SYSTEM 20mm air system pipes
1021 EQPT: SYSTEM PIPES (11) AIR SYSTEM Flexible pipes to engine damaged, needs renewal. With end fittngs( for Air horn)
1021 EQPT: SYSTEM PIPES (12) FRESH WATER SYSTEM 30 mm Ø fresh water system pipes (Mat.-CuNi)
1021 EQPT: SYSTEM PIPES (13) FRESH WATER SYSTEM 20 mm Ø fresh water system pipes (Mat.-CuNi)
1021 EQPT: SYSTEM PIPES (14) VOITH SYSTEM inlet outlet of coolers, 40mm
1021 EQPT: SYSTEM PIPES (15) FUEL SYSTEM 40 mm Ø fuel system pipes (Mat:- MS)
1021 EQPT: SYSTEM PIPES (16) FUEL SYSTEM 20mm Ø fuel system pipes (Mat.-MS)
1021 EQPT: SYSTEM PIPES (17) FUEL SYSTEM 20mm Ø fuel filling pipes upto RU tanks by separator. (Mat.-MS)
1021 EQPT: SYSTEM PIPES (18) FUEL SYSTEM 200mm Ø sea water system pipes (Mat.- CuNi)
1021 EQPT: SYSTEM PIPES (19) FUEL SYSTEM 100mm Ø sea water system pipes (Mat.- CuNi)
1021 EQPT: SYSTEM PIPES (20) FUEL SYSTEM 50mm Ø sea water system pipes (Mat.- CuNi)
1021 EQPT: SYSTEM PIPES (21) FUEL SYSTEM 65mm Ø sea water system pipes (Mat. - CuNi)
1021 EQPT: SYSTEM PIPES (22) FUEL SYSTEM 50mm Ø bilge water system pipes (Mat.- CuNi)
1021 EQPT: SYSTEM PIPES (23) FUEL SYSTEM 65mm Ø bilge water system pipes (Mat. - CuNi)
1021 EQPT: SYSTEM PIPES (24) FUEL SYSTEM 20mm Ø bilge water system pipes (Mat.- CuNi)
1022 EQPT: FOAM GUNS, MAKE: JASON, MODEL:FM200HJF-V-C-02, SL NO:1882-5217-3
1022 EQPT: FOAM GUNS, MAKE: JASON, MODEL:FM200HJF-V-C-02, SL NO:1882-5217-3 External Fire fighting system to be proved for operation, Foam guns and other accessaries to be completely overhauled, fitted back and proved for satisfactory operation. All perished rubber fittings to be renewed. Make Jason Engg pvt ltd.
1023 EQPT: CO2 FIRE EXTINGUISHING SYSTEM MAKE: ZEAL Marketing Pvt Ltd, mumbai - 400104
1023 EQPT: CO2 FIRE EXTINGUISHING SYSTEM MAKE: ZEAL Marketing Pvt Ltd, mumbai - 400104 (1) All CO2 cylinders to be weighed. If weight falls below the 10% of initial weight recharge the cylinders. Weight of the CO2 is 45kg each.
1023 EQPT: CO2 FIRE EXTINGUISHING SYSTEM MAKE: ZEAL Marketing Pvt Ltd, mumbai - 400104 (2)CO2 cylinders of master control boxes to be Removed pressure tested and recharged.
1023 EQPT: CO2 FIRE EXTINGUISHING SYSTEM MAKE: ZEAL Marketing Pvt Ltd, mumbai - 400104 (3)Non return valves (11 No's), QA valves (11 no's) , on cylinder heads to be overhauled.
1023 EQPT: CO2 FIRE EXTINGUISHING SYSTEM MAKE: ZEAL Marketing Pvt Ltd, mumbai - 400104 (4) Flexible hoses of the entire system to be pressure tested and replaced if required.
1023 EQPT: CO2 FIRE EXTINGUISHING SYSTEM MAKE: ZEAL Marketing Pvt Ltd, mumbai - 400104 (5) All CO2 discharge multi jet nozzles in E/R to be opened, Checked for chockages, Cleaned and fitted back. (2.5mm & 2mm)(11&4)
1023 EQPT: CO2 FIRE EXTINGUISHING SYSTEM MAKE: ZEAL Marketing Pvt Ltd, mumbai - 400104 (6) Overhaul of shuttle valve and relief valve assembly
1023 EQPT: CO2 FIRE EXTINGUISHING SYSTEM MAKE: ZEAL Marketing Pvt Ltd, mumbai - 400104 (7) Overhaul of pressure operated switch.
1023 EQPT: CO2 FIRE EXTINGUISHING SYSTEM MAKE: ZEAL Marketing Pvt Ltd, mumbai - 400104 (8) Complete drenching system piping to be blown through using HP air to prove system free of blockages.
1023 EQPT: CO2 FIRE EXTINGUISHING SYSTEM MAKE: ZEAL Marketing Pvt Ltd, mumbai - 400104 (9) All CO2 cylinders and system pipes to be painted as per color coding post work completion.
1023 EQPT: CO2 FIRE EXTINGUISHING SYSTEM MAKE: ZEAL Marketing Pvt Ltd, mumbai - 400104 (10) CO2 fire extinguish system alarm panel to be proved for operation. Renew defctive relays / solenoids /parts if any. And provr the system functionality with compressed air.
1023 EQPT: CO2 FIRE EXTINGUISHING SYSTEM MAKE: ZEAL Marketing Pvt Ltd, mumbai - 400104 (11) Call bell for CO2 system in ECR found broken, to rectify.
1024 EQPT: AIR SYSTEM RESERVOIRS
1024 EQPT: AIR SYSTEM RESERVOIRS (1) Air system reservoirs to be completely drained, and inspected.
1024 EQPT: AIR SYSTEM RESERVOIRS (2) All additional fittings on the reservoirs to be Checked for proper operation, renewed if required and tested.(including relief valves, drain valves, pr guages, pr guage isolating valves and piping etc)
1025 EQPT:STARTING AIR MOTOR MAKE:- TDI TURBOSTART TWO, CAT ,PART NO 3829606 (PORT) RH CW
1025 EQPT:STARTING AIR MOTOR (1) Starting Air motors of Main Engine (Port) is defective not developing Torque, to be Replaced with new one.
1026 EQPT:STARTING AIR MOTOR MAKE:- TDI TURBOSTART TWO, CAT ,PART NO 3982385 (STBD) LH CCW
1026 EQPT:STARTING AIR MOTOR (1)Starting Air motors of Main Engine (Stbd) is defective not developing Torque, to be Replaced with new one.
1029 EQPT: MISCELLANEOUS
1029 EQPT: MISCELLANEOUS (1) All M/E instumentation / pressure gauge lines to be renewed. Mat cu ni.
1029 EQPT: MISCELLANEOUS (2) Both M/E fresh water cooler to be chemical Cleaned and presure tested to 1.5 times of operating pressure..
1029 EQPT: MISCELLANEOUS (3) Both D/A exhaust line to be chemical Cleaned.
1029 EQPT: MISCELLANEOUS (2) Both M/E exhaust line to be chemical Cleaned
1029 EQPT: MISCELLANEOUS (3) Portable pump to be repaired / renewed.Make:Johonson,Type: Centrifugal, 1Hp
1029 EQPT: MISCELLANEOUS (4) Engine room work bench vise to be renewed along with foundation table.
1029 EQPT: MISCELLANEOUS (5) Exhaust funnel to be Cleaned and painted internally.
1029 EQPT: MISCELLANEOUS (6) Voith cooling pump Priming tank filling line diameter to be increased, job requires insitu drilling on priming tank and welding of 2'' pipe(length-10 cm) and to be fitted with cock.
1029 EQPT: MISCELLANEOUS (7) Emergency cooling connection to voith cooling water system from general service sea water system, Job involves Manufacturing of 02 T pieces(50 mm) with flanges and piping length of 05 mtrs,(dia (50mm) and 02 screw down valves of 2''.location as convinient by Operators
1029 EQPT: MISCELLANEOUS (8) Emergency cooling connection to DG cooling water system from general service sea water system, Job involves Manufacturing of 02 T pieces(50 mm) with flanges and piping length of 05 mtrs,(dia (50mm) and 02 screw down valves of 2''.location as convinient by Operators
1029 EQPT: MISCELLANEOUS (9) Emergency cooling connection to Main Engine cooling water system from general service sea water system, Job involves Manufacturing of 02 T pieces(100 mm) with flanges and piping length of 05 mtrs,(dia (50mm) and 02 screw down valves of 4''.location as convinient by Operators.
1029 EQPT: MISCELLANEOUS (10) Fuel transfer pump dischare to be provided with additional connection with valve to defuel the tanks to jetties.
1029 EQPT: MISCELLANEOUS (11) M/E expansion tank to be chemical Cleaned & preserved with OM 30.
1029 EQPT: MISCELLANEOUS (12) Fuel RU tank to be chemical Cleaned and preserved with OM 30.
1029 EQPT: MISCELLANEOUS (13) Quick closing valves not operating due loose wires including wire broken for ME RU tank (P&S), to be rectified.
1029 EQPT: MISCELLANEOUS (14) Alarm monitoring system for ME & Auxiliary machineries in ECR found non operational, to be rectified.
1029 EQPT: MISCELLANEOUS (15) Diesel driven Bilge pump found non operational.
1029 EQPT: MISCELLANEOUS (16) Self closing cock for sounding pipe in ER found jammed, to rectify.
1029 EQPT: MISCELLANEOUS (17) Various lekage in Air horn system to be rectified.Post rectify horn to be proved for satisfactory perfomance.
1029 EQPT: MISCELLANEOUS (18) Level gauge i.w.o Lube oil,dirty oil & Bilge holding tanks to be provided as per IRS recomendetion.
1029 EQPT: MISCELLANEOUS (19) Drip trays i.w.o FODS tank (P&S) and drain line end connection of LO purifier & FO purifier to be provided as per IRS recomendetion.
1029 EQPT: MISCELLANEOUS (20) Drain line to be provided in exhaust line of DG(port,stbd & harbour)
1029 EQPT: MISCELLANEOUS (21) Bilge high level alarm and emergency bilge suction remains pending to be shown.
1030 EQPT : DIESEL GENERATOR, MAKE: M/s KOEL ,MODEL: 6R1080TA, 100 KVA & HARBOUR DIESEL GENERATOR,MAKE: M/s KOEL ,MODEL: 4R1040T, 50 KVA Calibrate the following cutouts as per their set points. Renew if defective D/G (Port, Stbd & Harbour ) AV alaram panel system to be completely overhauled,caliberated and prove for satisfactory operation inclunding following jobs:-
1030 EQPT : DIESEL GENERATOR, (1) Fresh water temperature sensor Alarm. Set point 92°C
1030 EQPT : DIESEL GENERATOR, (2) Fresh water temperature Tripping cut out Set point 97°C
1030 EQPT : DIESEL GENERATOR, (3) Lub oil Pressure sensor for alarm set point 1.5 kg/sq cm
1030 EQPT : DIESEL GENERATOR, (4) Lub oil pressure sensor for tripping set point 0.5 kg/sq cm
1030 EQPT : DIESEL GENERATOR, (5) Over speed sensor for tripping set point 1650 rpm
1030 EQPT : DIESEL GENERATOR, (6) High temperature of alternator for tripping set point 70°C Note: above repairs/ routines to be undertaken by OEM/ authorised firms of OEM
1031 EQPT : FIRE FIGHTING PUMP REDUCTION GEARING / GEARBOX, Make : Jason Engg, Model :SRGO-255VK-1.12-CCW-02
1031 EQPT : FIRE FIGHTING PUMP REDUCTION (1) FiFi pump reduction gearing / gear box, Engaging and disengaging mechanisim to be completely opened and overhauled, to be proved on completion along with Fire Fighting pump.
1032 EQPT :VOITH PROPULSION , MAKE:VOITH TURBO SCHNEIDER PROPULSION, MODEL:VSP 21R5/150-2
1032 EQPT :VOITH PROPULSION , (1) Inspect the screw joints.
1032 EQPT :VOITH PROPULSION , (2)Inspect the shaft sealing for leaks.
1032 EQPT :VOITH PROPULSION , (3)Check the condition of blades.
1032 EQPT :VOITH PROPULSION , (4)Inspect the axial clearance of blades.
1032 EQPT :VOITH PROPULSION , (5)Inspect the condition of rotor casing coating & anodes.
1032 EQPT :VOITH PROPULSION , (6)Check for any leaks in rotor casing.
1032 EQPT :VOITH PROPULSION , (7)Inspect the input gear when the propeller is running.
1032 EQPT :VOITH PROPULSION , (8)Check for any leaks in mounting cover.
1032 EQPT :VOITH PROPULSION , (9)Check for lekage in propeller well.
1032 EQPT :VOITH PROPULSION , (10)Inspect the condition of permanent magnet filter rods.
1032 EQPT :VOITH PROPULSION , (11)Check the correct functioning of rotor space ventilation.
1032 EQPT :VOITH PROPULSION , (12)Change the sump oil with fresh oil. SP 150
1032 EQPT :VOITH PROPULSION , (13)Replace oil filter of system.
1032 EQPT :VOITH PROPULSION , (14)Caliberate the pressure transducer.(p1,p2 &p3)
1032 EQPT :VOITH PROPULSION , (15)Clean elevated oil tank of system.
1033 EQPT : MAIN ENGINE, MAKE : CATERPILLAR, MODEL:3512C Running hours PME : 6040 hrs, SME: 6040hrs All 6000 hourly routines on main engine to be carried out
1033 EQPT : MAIN ENGINE (1) Air Starter Motor Lubricator oil to be changed
1033 EQPT : MAIN ENGINE (2) Air Tank Moisture and Sediment Drain and recharge
1033 EQPT : MAIN ENGINE (3) Control Panel Inspect and Test
1033 EQPT : MAIN ENGINE (4) check and refill coolant level.
1033 EQPT : MAIN ENGINE (5) Inspect and Replace Air Cleaner service indicator.
1033 EQPT : MAIN ENGINE (6) Air filter to be Replaced.
1033 EQPT : MAIN ENGINE (7) Check oil filter differential pressure and Replace the oil filter.
1033 EQPT : MAIN ENGINE (8) Change engine oil.
1033 EQPT : MAIN ENGINE (9) Check fuel filter differential pressure and Replace the fuel filter.
1033 EQPT : MAIN ENGINE (10) Change fuel primary filter.
1033 EQPT : MAIN ENGINE (11) Check transmission oil level.
1033 EQPT : MAIN ENGINE (12) Clean/ Inspect engine speed/timing sensor.if required to be Replaced.
1033 EQPT : MAIN ENGINE (13) Check engine valve lash.
1033 EQPT : MAIN ENGINE (14) Inspect and caliberate fuel injector.
1033 EQPT : MAIN ENGINE (15) Inspect /adjust alternator belt adjustment.if required to be Replaced.
1033 EQPT : MAIN ENGINE (16) Change engine oil filter.
1033 EQPT : MAIN ENGINE (17) Inspect and Replace hoses & clamps.
1033 EQPT : MAIN ENGINE (18) Caliberate Air shutoff .if required to be Replaced.
1033 EQPT : MAIN ENGINE (19) Clean crankcase breather.if required to be Changed.
1033 EQPT : MAIN ENGINE (20) Replace fuel system secondary filter.
1033 EQPT : MAIN ENGINE (21) Clean Air starting motor lubricator bowl.
1033 EQPT : MAIN ENGINE (22) Inspect crankshaft vibration damper.
1033 EQPT : MAIN ENGINE (23) Inspect engine mounts.
1033 EQPT : MAIN ENGINE (24) Inspect turbocharger.
1033 EQPT : MAIN ENGINE (25) Inspect auxiliary water pump.if required to be rectify.
1033 EQPT : MAIN ENGINE (26) remove and Check Air shutoff damper.
1033 EQPT : MAIN ENGINE (27) Replace coolant temperature regulator.
1033 EQPT : MAIN ENGINE (28) Inspect prelube pump.if found defective to be rectify.
1033 EQPT : MAIN ENGINE (29) Inspect starting motor.if found abnormal to be rectify.
1033 EQPT : MAIN ENGINE (30) Inspect water pump.if found defective to be rectify.
1033 EQPT : MAIN ENGINE (31) Inspect camshaft roller followers.
1033 EQPT : MAIN ENGINE (32) Inspect sea water pump.if found defective to be rectify.
1033 EQPT : MAIN ENGINE (33) Fresh water cooler to be chemical Cleaned.
1033 EQPT : MAIN ENGINE (34) Lub oil cooler to be chemical Cleaned.
1033 EQPT : MAIN ENGINE (35) Air reducer to be caliberated.if required to be Replaced.
1033 EQPT : MAIN ENGINE (36) Freshwater coolers to be removed, completely dismentled, chemically cleaned and pressure tested.
1034 EQPT : MAIN ENGINE, MAKE: CATERPILLAR, MODEL:3512C Following items to be required as spares for general maintenance of main engines:-
1034 EQPT : MAIN ENGINE, (1) Mechanical seal, Bearing, Shaft,impeller, Key for Voith cooling Pump
1034 EQPT : MAIN ENGINE, (2)CAT coolant
1034 EQPT : MAIN ENGINE, (3)CAT lub oil
1034 EQPT : MAIN ENGINE, (4)Air filter
1034 EQPT : MAIN ENGINE, (5)Lo filter
1034 EQPT : MAIN ENGINE, (6)Fuel filter
1034 EQPT : MAIN ENGINE, (7)Fresh water cooler elements (plates)
ELECTRICAL WORK PACKAGE FIRM NOT TO QUOTE QUANTIFIED DEFECT LIST - SR 1 (DL) ELECTRICAL EQUIPMENT MOTORS. (A) BLOW THROUGH MOTOR WITH COMPRESSED AIR. CHECK INSULATION OF THE MOTOR, SHOULD NOT BE LESS THAN 2 M OHMS. (B) BEARINGS RENEWALS AT BOTH ENDS OF THE MOTOR. (C) INSPECT SHOCK MOUNTS, WASHERS, NUTS AND BOLT. CHECK FOUNDATIONS SECURING NUTS OF THE MOTOR FOR TIGHTNESS. 1.Carryout compleat overhaul routines and proove them for satisfactory performance / Made operational 2.Clean & Tighten the all connections with proper lugs, ferrules & connecters. 3. Check all circuits continuities 4.Check circuitry functions with control voltages
2001 MSB SWITCH BOARD , OEM: Marine Electrical , Mumbai
2001 MSB SWITCH BOARD 01 no Switch board with common bus bar system with four incoming feeders from two DAs.one harbour DG & shore supply And these four are electrically interlocked & connected to the two bus bars which is connected by bus coupler in swbd. Make Marine Electrical , mumbai
2001 MSB SWITCH BOARD (B) Check performance of switchboard and associated switch gear during load trials of generator. (NOTE: ETMU to access the performance)
2001 MSB SWITCH BOARD (C) MSB to be overhauled (includes defective switches to be renwed, perished control wiring to be renewed with crimping of proper lugs, marking sleeves to be put on control wiring and loose wirng to be tied with cable ties) Carryout routines mentioned below and prove them for satisfactory performance (calibration certificates/test reports from NABL recognised Labs are to be submitted) .
2001 MSB SWITCH BOARD (D) Renewal of MCCBs,make Schneider
2001 MSB SWITCH BOARD (E) Motor operated plug in type MCCB non ops. Renew Motor operated plug in type MCCB along with all its accessories. Rated:-415v,50 Hz,3phase, 250Amps. Make:schneider Model-NSX250B 3P LV431140
2001 MSB SWITCH BOARD (F)Check ,Calibrate all parameters of advanced digital protection relays (generator protection ), & made operational.(presently it was not working) (CT ratio 200/5A,415V,50Hz,aux voltage 24DC,DI-DO supply unit.24V DC modbus communication port,Can Bus Redundant &with Governor O/P suitable for GAC make speed control unit model ESD 5200) Make:Stucke Electronik, Model: SYMAP-Y (G)
2001 MSB SWITCH BOARD (G) Renew the advanced digital protection relays (generator protection ) unit, (CT ratio 200/5A,415V,50Hz,aux voltage 24DC,DI-DO supply unit.24V DC modbus communication port,Can Bus Redundant &with Governor O/P suitable for GAC make speed control unit model ESD 5200) Make:Stucke Electronik, Model: SYMAP-Y (G)
2001 MSB SWITCH BOARD (H) check & calibrate the synschroscope with check synchronising relay 380V-440V AC size 96X96,(rectify the fault if there is any fault(presently it was not working)) make:DEIF,Model:CSQ-3,415V,AC Marine
2001 MSB SWITCH BOARD (J) Rubber mat : Insulating Rubber Mat deteriorated. To be Renewed with high voltage Electrical rubber mat in front of MSB.(Thickness- 3mm) Make vardhaman model class c
2002 DGS Eqpt/System: Generators/Alternator Make:Stamford,415V,3Ph,50Hz,1500RPM,(100KVA-2nos,50KVA-1no)
2002 DGS Eqpt/System: Generators/Alternator Carryout routines mentioned below and prove them for satisfactory performance.(routine may be carried out with assistance of OEM or authorised Rep).
2002 DGSEqpt/System: Generators/Alternator (A) Overhaul the generators/alternator
2002 DGS Eqpt/System: Generators/Alternator (B) Check the insulation of Alternator with 500V Megger. The insulation resistance should not be less than 2 mega ohm. If less isolate the system and improve the insulation. Check inductance and capacitance of the alternator winding.
2002 DGS Eqpt/System: Generators/Alternator (C) Carryout varnishing of rotor and stator winding.
2002 DGS Eqpt/System: Generators/Alternator( D) Carryout balancing of rotor.
2002 DGS Eqpt/System: Generators/Alternator (E) Inspection of Lugs, clean the lugs with zero paper and replace if damaged.
2002 DGS Eqpt/System: Generators/Alternator (F) Check the condition (1) All sealing of the alternators, repaired if required. (2) Check the rotating rectifier assembly for any loose connection and check proper connection.
2002 DGS Eqpt/System: Generators/Alternator (G) Take SPM reading of DE/NDE bearing of alternators; carry out greasing by grease gun if required (yellow zone). Change the bearing if unset (red zone).
2002 DGS Eqpt/System: Generators/Alternator (H) Carryout alignment of Alternator and AVR
2002 DGS Eqpt/System: Generators/Alternator (I) Renew the AVR (Aumatic Voltage Regulator)
2002 DGS Eqpt/System: Generators/Alternator (J) Renew the Diode set (6diodes with suppessor) RSK2001
2003 DG TRAILS DG Load trails (SHIP LOAD
2003 DG TRAILS Post repair/routines. Trials to be conducted as per details/ regimes mentioned below. Observations / Defects observed to be liquidated and Trials to be reconducted.(with ship load) Post completion of the routines/overhaul, the machinery should be proved to rated/designed power / capacity without limitations/observations and vibration levels at all points should be less than 5 mm/sec. The equipment performance will be considered satisfactory only if it the performance trials are cleared by Naval Inspection Agency. SPM readings of generator to be in green zone. Stable supply for communication, navigation and survey equipment to be proved under total power failure condition. (a) Insulation of Generator Rotor and Starter to be 10M Ohm (b) Frequency Range to be 49.5 - 50.5 (c) Rate of change of frequency permissble limit is 0.2 - 0.4 Hz/sec (d) Drop values limit is 3.5 - 4% (e) Peak variation of frequency to be 0-100%, 50-75%, 75-100%, 100-75% and 100-0% (f) 02 sec recovery should be at all regimes (g) Peak variation of voltage recovery to be in 01 sec for all regimes. (h) Difference between average of 3 line RMS value wrt Normal at 100% load to be proved. (i) M-Load trial to be offered. (j) Overvoltage and Undervoltage protection to be proved.
2004 MOTORS Eqpt:Motors / Blowers carry out complete over hauling of the following motors (including blower parts for blowers) and prove for satisfactory operation. Renew the deffictive parts.
2004 MOTORS (A) Carry out complete over hauling of the following motors (including blower parts for blowers) and prove for satisfactory operation. Renew the deffictive parts. Sea water pumps 415V,3Ø,20HP
2004 MOTORS (B) Carry out complete over hauling of the following motors (including blower parts for blowers) and prove for satisfactory operation. Renew the deffictive parts. Domesting FW pump motor 415V,3Ø,0.5HP
2004 MOTORS (C) Carry out complete over hauling of the following motors (including blower parts for blowers) and prove for satisfactory operation. Renew the deffictive parts. Engine room supply Blower motor 415v,3ph,50Hz,10HP.
2004 MOTORS (D) Carry out complete over hauling of the following motors (including blower parts for blowers) and prove for satisfactory operation. Renew the deffictive parts. Fire & Bilge service pumps 415V,3Ø,12.5HP
2004 MOTORS (E) Carry out complete over hauling of the following motors (including blower parts for blowers) and prove for satisfactory operation. Renew the deffictive parts. GS pump 415V,12.5Hp,3Ø
2004 MOTORS (F) Carry out complete over hauling of the following motors (including blower parts for blowers) and prove for satisfactory operation. Renew the deffictive parts. Supply fan voith 415V,3Ø,2HP
2004 MOTORS (G) Carry out complete over hauling of the following motors (including blower parts for blowers) and prove for satisfactory operation. Renew the deffictive parts. Engine room supply/Exaust Blower motor (Reversable) 415V,3Ø,50Hz,10HP.
2005 Group starter panel
2005 Group starter panel (A) Group starter panel in MCR room.(it was having two sections & each section having 8 in nos starter controls including remote copntrol Push Buttens & group wise remote Emergency buttens)
2005 Group starter pane (B) GSP to be carry out complete overhauling (includes defective switches to be renwed, perished control wiring to be renewed with crimping of proper lugs, marking sleeves to be put on control wiring and loose wirng to be tied with cable ties) (calibration certificates/test reports from NABL recognised Labs are to be submitted) .
2005 Group starter panel (C) Renew the remote emergency push buttons switches
2005 Group starter panel (D)Time Delay Switch (Make: selec,Model 800XU) to be provided for reversable E/R supply fan starter & etc & made operational.
2006 Eqpt/System: Shore Supply Box . Make:Marine Electrical,100amps,415V,3ph Carryout routines mentioned below and prove them for satisfactory performance
2006 Eqpt/System: Shore Supply Box (A) Renew the indication lamps with holders-3Nos
2006 Eqpt/System: Shore Supply Box. (B)Renew the window glass size 500mmX20mm(approximatly) including rubber gasket.
2006 Eqpt/System: Shore Supply Box. (C)Provide the Phase Sequence Change over switch 2 Way with OFF 415V,4 pole,100A.near the shore supply panel box & connect the switch in shore supply circuit & made operational.
2006 Eqpt/System: Shore Supply Box. (D)provide the water proof (IP65)panel with door type for Phase Sequence Change over switch.
2006 Eqpt/System: Shore Supply Box. (E)Renewal of shore suppply cable 3x50 sqmm, rubber insulated, Copper multi stranded wire marine cable (presntly the existing cable was damaging condition)
2007 Eqpt/System:-shore supply cable reel drum mechanisam
2007 Eqpt/System:-shore supply cable reel drum mechanisam (A)carry out complete over hauling of the cable drum incuding slip ring mechanisam and prove for satisfactory operation. Renew the deffictive parts.
2007 Eqpt/System:-shore supply cable reel drum mechanisam (B)Renew the slip ring set (presently it was deffective)
2007 Eqpt/System:-shore supply cable reel drum mechanisam (C)Renew the Bearings.
2008 Eqpt/System: Light fittings. Renewal of following navigation lights
2008 Eqpt/System: Light fittings. (A)Renew the AC navigational bulbs 230V,60w
2008 Eqpt/System: Light fittings. (B)Renew the DC navigational bulbs 24V,60w
2008 Eqpt/System: Light fittings. (C) Follwing Light Fittings corroded, to be renewed: Watertight 24V,10W,Bulkhead Emergency Light Fittings Renew the total light fittings with LED fittings 10W,24V,DC along with necessary accessories and wiring renewal as required (the bulb must be operated 15V DC to 30V DC)(WT (ip65)surface type-25nos,flash type 25nos
2008 Eqpt/System: Light fittings. (D) Renew Flush mounting Type indoor Twin LED tube light lamp Fittings 230V, 2X20W,LED light fittings, Make- Sysca/philips
2008 Eqpt/System: Light fittings. (E) Renew Industrial Type watertightTwin LED tube light lamp Fittings 230V, 2X20W,LED light fittings, Make- Sysca/philips
2008 Eqpt/System: Light fittings. (F) Renew LED Flood Light Fitting (WT) in Deck area. 120W,230V,AC; Make Sysca/philips
2008 Eqpt/System: Light fittings. (G) Renew LED Flood Light Fitting (WT) in E/R 120W,230V,AC; Make Sysca/philips
2009 Eqpt/System: Navigational Lighting Panels(AC & DC) Make:Edna 230V for AC,24V for DC
2009 Eqpt/System: Navigational Lighting Panels(AC & DC) (A) Carryout routines mentioned below and prove them for satisfactory performance Clean & Tighten the all connections with proper lugs, ferrules & connecters
2009 Eqpt/System: Navigational Lighting Panels(AC & DC) (B) Check the functions of all fuse units,control cards, indication lamps & horn. (1) If deffective repair them (2) If un repairable than renew them.
2009 Eqpt/System: Navigational Lighting Panels(AC & DC) (C) Renew the fault detection module cards.
2009 Eqpt/System: Navigational Lighting Panels(AC & DC) (D) Rectify the faults in the MIMIC along with led lamps -24V-1no,230V-1no (presently n/w)
2010 Eqpt/System: Batteries Accomadation Boxes (Wooden)
2010 Eqpt/System: Batteries Accomadation Boxes (A) Renew the complete box along with top opene door type(for accommodate 2 in nos 180AH 12V batteries in each box) with 12mm Hylam sheet & provide led sheet as inside layer for every box (i.e bottem & sides) & painted the boxes with gray color for outside
2011 Eqpt/System:DG Engine (Make:KOEL;MODEL:6R1080T) starting control pannel
2011 Eqpt/System:DG Engine (1) Carryout compleat overhaul routines and proove them for satisfactory performance / Made operational (2) Clean & Tighten the all connections with proper lugs, ferrules & connecters. (3) Check all circuits continuities. (4) Check circuitry functions with control voltages. (5) Check all other accessories replace them if there is any deffective part
2011 Eqpt/System:DG Engine (A) Renew the speed control unit for ESD5200 series
2011 Eqpt/System:DG Engine (B)Renew the generator engine protection display unit
2011 Eqpt/System:DG Engine (C) Renew the magnetic switches 24v DC for self starter circuit
2011 Eqpt/System:DG Engine (D)Renew the self starters 24V DC for above engine
2011 Eqpt/System:DG Engine (E)Renew the dynamos 24V DC for above engine models
2011 Eqpt/System:DG Engine (F)Renew the self starters 12V DC for KOEL engine
2011 Eqpt/System:DG Engine (G)Renew the dynamos 12V DC for KOEL engine
2012 Eqpt/System: Fire Detection & Alaraming System Make:Marinelec Technolgies; Model:D109_MANUEL_GB REV2
2012 Eqpt/System: Fire Detection & Alaraming System (A) Check circuitry functions with control voltages
2012 Eqpt/System: Fire Detection & Alaraming System (B) Renew the Fire Detection panel display system unit Model:D109_MANUEL_GB REV2
2013 Eqpt/System: Digital Tank Content Level Indication System Make:pune Techtrol Pvt Ltd Model:SLT-11SFW
2013 Eqpt/System: Digital Tank Content Level Indication System (A) Carryout compleat overhaul routines and proove them for satisfactory performance / Made operational (presently not working)
2013 Eqpt/System: Digital Tank Content Level Indication System (B) Provide the bilge level sencers along with cableling & indication cum alaram system
2014 Eqpt/System:Battery control switch
2014 Eqpt/System:Battery control switch (A) Provide the 100A TP MCCB along with suitable accommodate box at entrance of E/R in allaway area.and connect in the circuit.
2014 Eqpt/System:Battery control switch (B) Renew the 1core 30sq.mm copper multi satand flexible rubber cable
2014 Eqpt/System:Battery control switch (C) Laying of cableing (4 lines of 1core 30sq.mm copper cable)from DCDB (located at under w/h) to entance of E/R in allaway area
2015 Eqpt/System: Cooking Range with 2 hot plates with oven;430V 3ph 6kw. Make:M/S Krist Engineering & Mfg compeny
2015 Eqpt/System: Cooking Range with 2 hot plates with oven (A) Carryout compleat overhaul routines and proove them for satisfactory performance / Made operational
2015 Eqpt/System: Cooking Range with 2 hot plates with oven (B)Clean & Tighten the all connections with proper lugs, ferrules & connecters
2015 Eqpt/System: Cooking Range with 2 hot plates with oven (C)Check all circuits continuities
2015 Eqpt/System: Cooking Range with 2 hot plates with oven (D) Renew the Heating elements ("W" type) 430V,1500W
2015 Eqpt/System: Cooking Range with 2 hot plates with oven (E) Redisgn the hot plate as per sample provided by the ship staff.
2015 Eqpt/System: Cooking Range with 2 hot plates with oven (F) Check circuitry functions with control voltages
2015 Eqpt/System: Cooking Range with 2 hot plates with oven (G) Renew the temperature sensers
2015 Eqpt/System: Cooking Range with 2 hot plates with oven (H) Renew the W/T iron clad 3ph 430V 30A plug top along with socket.
2015 Eqpt/System: Cooking Range with 2 hot plates with oven (I) Renew the internal wiring with heat resistance multi stand flexible copper cable 4sq.mm
2016 Eqpt/System: SCR control rectifier unit 2kw for M/E Make:ELTEK SGS PVT LTD Model type:FP2-2000W; Input 230V AC,out put 24v DC
2016 Eqpt/System: SCR control rectifier unit 2kw for M/E (A) Carryout compleat overhaul routines and proove them for satisfactory performance / Made operational
2016 Eqpt/System: SCR control rectifier unit 2kw for M/E (B)Clean & Tighten the all connections with proper lugs, ferrules & connecters
2016 Eqpt/System: SCR control rectifier unit 2kw for M/E (C)Check all circuits continuities
2016 Eqpt/System: SCR control rectifier unit 2kw for M/E (D)Check circuitry functions with control voltages
2016 Eqpt/System: SCR control rectifier unit 2kw for M/E (E)Check all other accessories replace them if there is any deffective part
2017 Eqpt/System: Wall mounted Electrical fans (Oscillating) Make:C&G, Type- 400 mm Sweep
2017 Eqpt/System: Wall mounted Electrical fans (Oscillating) (A) Renew the fans fitted at various places and prove them for satisfactory performance
2017 Eqpt/System: Wall mounted Electrical fans (Oscillating) (B)Renew the fans fitted at crew acomidation place prove them for satisfactory performance
2018 Eqpt/System:split A/Cs
2018 Eqpt/System:split A/Cs (A) Renew & installing the 3 in nos spilt A/Cs at acommidation-2nos (1.5 Tons),2ton for W/H- 1nos,master cabin -1no(1.5ton),Engineer cabin-1no (1.5ton) (the job included the gutting & regutting,laying of cabling)
2018 Eqpt/System:split A/Cs (B) Provide the 1 in no Delta/Delta transformer 25KVA input3Ph,415V,50Hz & out put 3Ph,230V,50Hz at under W/H area (installation,conections & prove satisfactory operation)
2018 Eqpt/System:split A/Cs (C) Renew & layin of 3X10sq.mm multi stant copper marine cable (from MSB to under W/H) &(trnasformer to MCB DB)
2018 Eqpt/System:split A/Cs (D) Renew & laying of 3X6sq.mm multi stant copper marine cable (from under W/H to variou ac locations via switches)
2018 Eqpt/System:split A/Cs (E) Renew & install the 1 in no MCB DB panel box Which is required to have 10 in nos DP MCB 20A,2 nos TP 60A mcb,3 in nos LED indication lamps,name tally plates,connecting clips.
2018 Eqpt/System:split A/Cs (F) Renew the 3 in nos industrial sockets for Acs.
2018 Eqpt/System:split A/Cs (G) Renew the 3 in nos Ac stebilisers
2019 Eqpt/System:Hot Water Boiler Make:M/s kantilal chunilal &sons.
2019 Eqpt/System:Hot Water Boiler (A) Repair/overhauling of hot water boiler 20ltrs 230V
2020 Eqpt/System: Water cooler & water purifier 20ltrs 230V Make:M/s.Alfa Aircon & M/s Bombay Gas light.
2020 Eqpt/System: Water cooler & water purifier 20ltrs (A) Repair/overhauling of water cooler & water purifier 20ltrs 230V Make:M/s.Alfa Aircon & M/s Bombay Gas light.
2021 Eqpt/System:Main Engine (Make:Caterpillar ,Model-CAT3512C Engines,1194KW@1600RPM) starting control pannel (including Local & Remote Panels) Make:GMMCO
2021 Eqpt/System:Main Engine (Make:Caterpillar) (A) Carryout compleat overhaul routines and proove them for satisfactory performance / Make operational
2021 Eqpt/System:Main Engine (Make:Caterpillar) (B) Clean & Tighten the all connections with proper lugs, ferrules & connecters
2021 Eqpt/System:Main Engine (Make:Caterpillar) (C) Check all circuits continuities
2021 Eqpt/System:Main Engine (Make:Caterpillar) (D)Check circuitry functions with control voltages
2021 Eqpt/System:Main Engine (Make:Caterpillar) (E) renew the indication lamps along with holdfers.
2021 Eqpt/System:Main Engine (Make:Caterpillar) (F) Renew the ON key switches
2021 Eqpt/System:Main Engine (Make:Caterpillar) (G) Renew the push butons along contacts
2021 Eqpt/System:Main Engine (Make:Caterpillar) (H) Renew the control pcb
2021 Eqpt/System:Main Engine (Make:Caterpillar) (I) Renew the emergency stop butons along with safety cap
2022 Eqpt/System:Electrical Horn
2022 Eqpt/System:Electrical Horn (A) Provide the suitable ship electrical horn for 50mtrs to 75 mtrs length vessels along with control panel.sound >130db,weather proof,& rust proof material
2023 Eqpt/System:Air Horn controling system. Make:M/s Krist Eng & Mant corp. Ghaziabad 1.Carryout compleat overhaul routines and proove them for satisfactory performance / Made operational 2.Clean & Tighten the all connections with proper lugs, ferrules & connecters. 3. Check all circuits continuities 4.Check circuitry functions with control voltages
2023 Eqpt/System:Air Horn controling system. (A) Renew the control pcb
2023 Eqpt/System:Air Horn controling system. (B) Renew the air soilnoid valves along with coil 230V AC
2023 Eqpt/System:Air Horn controling system. (C) Renew the air soilnoid valves along with coil 24V DC
2023 Eqpt/System:Air Horn controling system (D) Renew the Timer pcb
2024 Eqpt/System:Engine Room Ventilation Fans.Make:M/s Heinen & hopman engineering pvt ltd, kolkatta
2024 Eqpt/System:Engine Room Ventilation Fans (A) Ventilation fans running with abnormal sound..Required to noise level to be decreses <50db by redesign the equipments
RECOMMENDED SPARE LIST FOR MAIN ENGINES (02) CAETRPILLAR 3512C
ELEMENT-F PART NO. 9M-2342 HSN CODE- 7326
GASKET PART NO.8H-2778 HSN CODE - 4016
SEAL-O-RING PART NO.6V-3907 HSN CODE - 4016
FILTER A PART NO.1R-0726 HSN CODE -8421
ELEMENT AS PART NO.1R-0756 HSN CODE - 7326
PRI ELEMENT AIR PART NO.226-2779 HSN CODE - 7326
SEAL-O-RING PART NO.6V-9027 HSN CODE - 4016
BREATHER A PART NO.4W-3027 HSN CODE -8341
SEAL-O-RING PART NO.033-6031 HSN CODE - 4016
CLAMP PART NO.4W-3034 HSN CODE - 7326
O RING SEAL PART NO.8T-7877 HSN CODE -4016
ROD AS ZINC PART NO.116-7011 HSN CODE - 8409
ROD PART NO.6L-2280 HSN CODE -8431
HOSE (BULK) (length IN CM) PART NO.371-1253 HSN CODE - 4009
ELE PREMIX 20 LTR (OLD NO 3658396) PART NO 4692718 HSN CODE -3820
CAT DEO C14 BARREL (208 LTR) PART NO 3E9840 HSN CODE - 2710
CAT DEO C14 PAIL (20 LTR) PART NO.3E9848 HSN CODE - 2710
BOTTLE GP PART NO.169-8373 HSN CODE - 7326
PROBE HOLDER PART NO.162-8374 HSN CODE - 7307
CLAMP PART NO 5P-0597 HSN CODE - 7326
CLAMP PART NO 5P-9848 HSN CODE - 7326
HOSE T PART NO 217-6692 HSN CODE - 4009
REGULATOR PART NO 4W-4011 HSN CODE - 9032
GASKET PART NO 7N-4927 HSN CODE - 4016
GASKET PART NO 2N-0931 HSN CODE - 4016
SEAL-O-RING PART NO 6V-1454 HSN CODE - 4016
LIP- SEAL PART NO 3S-9843 HSN CODE - 4016
GASKET PART NO 148-7996 HSN CODE - 4016
REGULATOR 30 DEG PART NO 219-3240 HSN CODE - 9032
LIP- SEAL PART NO 3S-9643 HSN CODE - 4016
SEAL-O-RING PART NO 6V-1454 HSN CODE - 4016
PLUG PART NO 287-7296 HSN CODE 8536
PLUG PART NO 223-8525 HSN CODE 8536
JOINT AS TUBE PART NO 7L-3201
PLATE GP - HEAT EXCHANGER PART NO300-5623
SEAL-O-RING PART NO 8L-8585
DRIVE AS MOTOR PART NO 6N-3826
SOLENOID AS STARTING MOTOR PART NO 318-2082
KIT TERMINAL PART NO 3N-3763
KIT SEAL & VANE PART NO 5N-8390
KIT VALVE SEAL PART NO 7C-5105
FILTER ELEMENT AS-AIR PART NO 208-9065
RECOMMENDED SPARE LIST FOR 5K ROUTINES DIESEL GENERATORS - KIRLOSKAR 6R 1080
CENTRIFIGUAL FILTER SERVICE KIT FR SL.90 & 6R PART NO.F6.999.100.0.00
KOEL CARE SUPER GENUNINE OIL 20 LTRS CAN PART NO.82.050.10.0.20
LUB OIL FILTER PART NO.DV0.014.02.0.00
PRIMARY ELEMENT PART NO.6H.411.02.0.00
V BELT ROULANDS (1250) MAKE PART NO.4H.1531.01.0.00
V BELT COGGED (BX-48) PART NO.47.305.01.0.00
FUEL FILTER CARTRIDGE DUPLEX TYPE PART NO.4H.333.03.0.00
KOEL CARE SUPER GENUNINE OIL 26 LTRS CAN PART NO.82.020.35.1.25
FUEL PIPE (PRIMARY TO SECONDARY) PART NO.F6.353.112.0.00
1 METER LONG FUEL HOSES WIRE BREADED PART NO.6H.466.35.0.00
1 METER LONG FUEL HOSES WIRE BREADED PART NO6H.466.36.0.00
WIRE BRAIDED PIPE FROM JACKED LEAFOFF TO FUEL COLLECTOR PART NO 6H.945.14.0.00
LUB OIL SUPPLY HOSE (CRANK CASE TO FIP) FOR IRS PART NO .4H.333.01.0.00
WIRE BRAIDED OIL PIPE FOR DUPLEX FILTER PART NO.4H.333.11.0.00
WIRE BRAIDED OIL PIPE FOR DUPLEX FILTER(LONG) PART NO.4H.333.29.0.00
HP PIPE ASSEMBLY (DIA 6.35 x 1.8) PART NO.6H.945.50.0.00
COMBINED LEAK OFF PIPE ASSLY PART NO.6H.945.40.0.00
O-RING FOR DRAIN PLUG PART NO.F6.024.47.0.00
THERMOSTAT BYPASS HOSE PART NO.4H.023.02.0.00
HOSE STRAIGHT 70 MM LENGTH WITH CENTRAL HUMP PART NO.4H.366.07.0.00
L.O. SUPPLY HOSE (FIP) M10 BANJO ENDS X 235 L PART NO.4H.006.01.0.00
RUBBER HOSE (FOR 'TR55' TURBO, COMPRESSOR OUTLET) PART NO.4H.168.11.0.00
HOSE FOR AIR CLEANER (70 IDX80 L) PART NO.6H.466.47.0.00
HOSE (DANALDSON P532944-3 RINGS -4 PLY 102X152 260 DEGC CAC- INLET PART NO.4H.073.01.0.00
HOSE FOR WATER PUMP INLET TO RAD OUTLET PART NO.4H.073.02.0.00
HOSE ( RADIATOR TO WATER PUMP PIPE (45X45X130L) PART NO.6H.073.01.0.00
HOSE ( PIPE TO WATER PUMP PIPE (45X45X130L) PART NO.4H.073.02.0.00
HOSE MAKE UP CONNECTION PART NO.6H.036.14.0.00
SS JOINT (4") PART NO.F6.503.02.0.00
JOINT FOR ADAPTOR (TURBO SIDE) PART NO.4H.132.27.0.00
JOINT FOR ADAPTOR CRANKCASE SIDE PART NO.4H.132.31.0.00
JOINT SS (FOR TURBO CHARGER) PART NO.6H.029.01.0.00
R RINGS (DIN 70910-65X2.5) PART NO.F6.168.02.0.00
S.SS JOINT FOR EXHAUST MANIFOLD PART NO P2.106.01.0.00
INJECTOR ASSLY (V.S TURBOCHARGERD ENGINE) PART NO.4H.154.10.0.00
WASHER FOR INJ (BOSCH NO 243999032/ 2430105020) PART NO.10.029.07.0.00
O RING FOR NOZZLE PART NO.3H.009.11.0.00
THERMOSTAT ELEMEMNT (74 DEG) WTIL NO DEV358 PART NO.39.040.09.0.00
JOINT FOR THERMOSTAQT COVER (METALLIC) PART NO.4H.053.08..0.00
PISTON RING SET (105 DIA PART NO.2H.009.30.0.00
INLET AND EXHAUST VALVE PAIR PART NO 4H.007.40.0.00
VALVE GUIDE (FOR INLET & EXHAUST) PART NO.4H.007.02.0.00
VALVE SHEET INSERT INLET PART NO.4H.007.03.0.00
VALVE SHEET INSERT EXHAUST PART NO.4H.007.04.0.00
VALVE SEAL PART NO.06.631.02.0.00
VALVE COLLET (PAIR) PART NO.02.022.12.0.00
VALVE SPRING PART NO.02.022.13.0.00
VALVE SPRING CUP PART NO 34.013.13.0.00
CONNECTING ROD BOLT PART NO.04.692.03.0.00
BEARING C/R KIR HA 694 PART NO B.075.4.00.003
SET OF JOINTS FOR 6H.4598 PART NO .6H.522.76.0.00
SET OF O RINGS FOR 6H.4598 PART NO.6H.522.80.0.00
SET OF WASHERS FOR 6H.4598 PART NO 6H.522.77.0.00
ANTI VIBRATION MOUNTING 144 CRS CORI RUBBER PART NO 6H.118.02.0.00
SHOCK MOUNT PART NO 6H.720.07.0.00
BOLT FOR CYLLINDER HEAD PART NO 4H.007.07.0.00
CYLLINDER LINER (105MM DIA) PART NO 2H.008.01.0.00
EXHAUST TEMEPERATURE SENSOR, 1/4" CONNECTION RADIX MAKE TYPE- K) PART NO 6H.715.31.0.00
PRESSURE TRANSMITTER (DANSFOSS MAKE TYPE -MBS 3250, RANGE 0 TO 10 BAR OUT PUT 4 TO 20 mA) PART NO 6H.715.27.0.00
LUB OIL PRESSURE SENSOR WITH SWITCH THREE POINT DUAL WIPER TYPE, CONTINTENTAL MAKE PART NO 46.252.05.0.00
TEMP SENSOR WITH INBUILD TRANSMITTER ( DANSOSS MAKE TYPE mbt5560 , RANGE 0 TO 150 DEG OUTPUT 4 TO 20mA) PART NO 6H.715.26.0.00
COOLENT TEMP.SWITCH 95+1/3 DEG(RICO/ RIDDHI SIDDH) PART NO 4H.907.01..0.00
AVR-MX321 TYPE FOR STAMFORD ALTERNATOR 160 KVA AT NTP, 415 VOLTS, 50 HZ 3 PHASE, 0.8 PF PART NO 6H.892.06.0.00
LUB OIL PRESSURE GAUGE (0-10 KG/ SQ CM) PART NO 46.244.01.0.00
LUB OIL TEMP GAUGE ( 3METER CAPILLARY) PART NO 49.087.01.0.00
WATER TEMP GAUGE, 1.8 M CAPPILARY PART NO 38.027.02.0.00
INDICATING LAMP, SCHINDER MAKE 24 VDC XB7EVO3BPN (GREEN) PART NO 6H.717.31.0.00
TEMPERATURE INDICATOR 24V DC PART NO 6H.715.08.0.00
MCB 10 AMP 2 POLE PART NO 06.980.12.0.00
RELAY BOARD UL MAKE 4 CHANNEL 24 V DC 2 CHANGE OVER PART NO F6.865.05.0.00
2.5 TERMINAL STRIP PHONIX MAKE UK 2.5 PART NOF6.082.05.0.00
DIODE RECTIFIER SEMI CONDUCTOR MAKE 16 AMP. RECTIFIER 35-10 PART NO DV2.860.34.0.00
RECOMMENDED SPARE LIST FOR STP WARTSILA HAMWORTHY MODEL - STC 02, GO No-98087-01
PUMP 1) IMPELLER SCREW 2)PEEL OFF SHIM 3)MECHANICAL SEAL 4)TAB WASHER
BLOWER 1)BLOWER 2)FILTER ELEMENTS 3)SET OF BEARINGS 4)SET SPACERS AND TOLERANCE RINGS
CONTROLS 1)CONTACTOR 2)AUXIALARY CONTACTOR 3)RELAY 4)BULB
SAMPLING KIT SAMPLING KIT
CHLORINATION CHEMICAL 25 LITRE DRUM
DE CHLORINATION SOLUTION 25 LITRE DRUM
CHLORINATION DOSING PUMP COMPLETE SPARE KIT
DECHLORINATION DOSING PUMP COMPLETE SPARE KIT
DIFFUSERS DIFFUSERS
HATCH COVER JOINTS FULL SET
AIR FLOW METER COMPLETE REPLACEMENT
RECOMMENDED SPARE LIST FOR VOITH PROPULSION
GREASE
REACTIVE ANODE 45X160X405, TYPE:20-Z POSITION:FLOATING
FILTER ELEMENT POSITION:DRYDOCK
AERATION ELEMENT POSITION:FLOATING
SEAL 605X545X3 POSITION:DRYDOCK
SEAL 310X250X3 POSITION:DRYDOCK
SEAL 2X335X490 POSITION:FLOATING
FUSIBLE PLUG POSITION:FLOATING
MTS SWITCH ELEMENT POSITION:FLOATING
SEAL RING 42X49 POSITION:DRYDOCK
LIST OF ANTICIPATORY SPARES:-
CONTAMINATIUON INDICATOR POSITION:FLOATING
THERMOMETER POSITION:FLOATING
THERMOMETER POSITION:FLOATING
THERMOMETER POSITION:FLOATING
THERMOMETER POSITION:FLOATING
THERMOMETER POSITION:FLOATING
PRESSURE SWITCH POSITION:FLOATING
PRESSURE SWITCH POSITION:FLOATING
THERMOMETER PROB HOUSING POSITION:FLOATING
FLOAT SWITCH POSITION:FLOATING
FLOAT SWITCH POSITION:FLOATING
SWITCH POSITION:FLOATING
RESIST THERMOMETER POSITION:FLOATING
GASKET POSITION:DRYDOCK
SCREW PLUG POSITION:DRYDOCK
IF REQUIED - CONTRACTOR / CUSTOMER SCOPE:-
PROPELLER OILS
TURBO COUPLING OILS
PEDASTAL BEARING
GEAR COUPLING
DOCKING AND ALLIED SERVICES
(A) Docking and undocking charges (Both Versions)
(B) Dock blocks preparation & laying out as per docking plan
Dock hire charges for an estimated duration of 60 Days as per OCR
Wet basin/alongside hire charges for the remaining duration (i.e. total refit duration of 90 days – 60 days docking period)
Provision of sufficient lighting for duty staff
(a) Quote for maintenance of two in no. fire lines for the refit duration .
(b) Two each connection/ disconnection charges for for the refit duration
Provision of two transports (cars) for entire refit duration (one for refit Co-ordinating staff and one for ND(V) monitoring Team) for 10 hrs or 100KM/day whichever is less
Mail Man services (02) Nos for entire refit duration (one for user Department and one for planning /Co-ordinating department )to be provided for 10 Hrs per day
QC inspection for the entire scope of work by third party IRS/LRS/ABS/QC/TPI for the refit duration as per the QIS
YEOMAN MARINE SERVICES PVT. LTD.
Patel Engineering Works Vizag
Flash Forge Private Limited
SAGAR SHIP REPAIRERS AND MARINE SERVICES
Bidder Name
Patel Engineering Works Vizag
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid