Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.0 LAccepted-AOC AJITH BHAVAN KANDAMTHITTA PANTHA PO THIRUVANANTHAPURAM KERALA 695573 | THIRUVANANTHAPURAM | KERALA | 695573 | ₹3.0 L | 1 | Accepted-AOC selected |
Tender Value
₹4 L
EMD Value
₹4,000
Closing Date
26 Oct 2024, 5:00 pmClosed
Chief Government Analyst
Drugs Testing Laboratory,Red Cross Road,Vanchiyoor(P.O) Thiruvananthapuram-695035
Comprehensive Annual Maintenance Contract for AIR HANDLING UNITS (With calibration)
2024_DCD_693063_1
EP-01/2024-25/DTL/TVM
Open Tender
AMC/ Maintenance Contracts
Service
30 days
Drugs Testing Laboratory
Please refer tender documents
3 documents required · 3 mandatory
₹800
Yes
₹4,000
Yes
30 Jan 2025
28 Sept 2024
29 Oct 2024
28 Sept 2024
26 Oct 2024
28 Sept 2024
I) Clean Room Validation as per grade A, B, C & D (i) Air Flow Velocity (ii) Air Changes per Hour(iii) Filter Integrity Test (iv) Differential Pressure (v) Recovery Time (vi) Room Temperature & Humidity(vii) Particle Count II) Maintenance, Servicing & Overhauling works of HVAC System A) Air Handling Units - 3 Nos (8.5 Ton x 2 Nos. & 5.5 Ton x 1 No.) (i) Flushing and Cleaning of Finned Surface & DX Tubes of Cooling Coils(ii) Checking & Replacement of faulty Fan Bearing(iii) Checking & Replacement of faulty Motor Bearing(iv) Checking of Belt Allignment and Tension & Mounting Bolts.(v) Cleaning of Filters, Replacement of Defective Belts, Pulleys, Blowers, Shafts, Bearings of AHUs whenever found defective. B) Electrical Panels and Wiring (i) Checking and Servicing of Contactors, Capacitors, Overloads, MCCBs and Fuses, Tightening of wiring connections and Replacement of faulty parts if required.(ii) Checking of Wiring Insulations & Motor Winding (iii) Checking of Earthing. C) Outdoor Units - 3 Nos (8.5 Ton x 2 Nos. & 5.5 Ton x 1 No.) Flushing & Cleaning of finned surface of condenser, General Change of compressor oil if required, greasing of bearing and oiling wherever required, replacement of motors and compressor if required. Topping of refrigerant whenever required. Rectification of leak if any and testing the system with nitrogen pressure and re-commissioning after vaccumization, replacement of insulation sleeves on Copper tubings.
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .