| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAdmitted-Finance | ₹9.4 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SV ENVIRO LABS & RESEARCH PRIVATE LIMITED L1 |
|---|---|---|---|---|
| 1.00 | CPP AND SHAFTINGWARTSILA/4E1540R-HB TYPEMT - 271101 O1
Sample oil from the hub and undertake analysis.Details of Oil - HLP 46, | 1 | NOS | 3,500 ₹3,500 Lowest |
| 2.00 | STEERING GEAR SYSTEMMAKE/ MODEL - VELJAN HYDRAIR P11P2R1C4A2BMT - 430102 SR4
Carry out chemical analysis | 1 | NOS | 3,500 ₹3,500 Lowest |
| 3.00 | ANALYSIS OF LUB OIL, COOLANT, HYDRAULIC OIL AND PORTABLE WATER. PAYMENT AT ACTUALS ANALYSIS OF LUB OIL, COOLANT AND PORTABLE WATER OF ALL MAIN ENGINES, DIESEL ALTERNATORS, GEAR BOXES AND AUXILARY MACHINERIES TO BE CARRIED THROUGH NABL CERTIFIED LABORATRY AND TWO COPIES OF EACH REPORT TO BE SUBMITTED WITHIN 24 HOURS OF TEST UNDERTAKEN. | 1 | LS | 35,000 ₹35,000 Lowest |
| 4.00 | (A) LUB OIL TEST(I) BASIC TEST:- THE BASIC TEST OF LUB OIL SHOULD COVERS THE FOLLOWING:-(a) BY USING METHOD OF ASTM D445 :- (aa) VISCOSITY @ 40 DEGREE C (CST) (ab) VISCOSITY @ 100 DEGREE C (CST) (ac) VISCOSITY INDEX (CALCUATED) | 75 | Times | 2,000 ₹1,50,000 Lowest |
| 5.00 | b) WATER CONTENT (% VOL) BY ASTM D95 METHOD.(c) FLASH POINT ( DEGREE CENTIGRADE) BY ASTM D92 METHOD(d) TBN (MG KOH/G)) BY ASTM D644 METHOD(e) TAN (MG KOH/G)) BY ASTM D644 METHOD | 1 | LS | 3,000 ₹3,000 Lowest |
| 6.00 | (II) ADVANCE TEST :- THE ADVANCE TEST OF LUB OIL SHOULD COVERS THE FOLLOWING BY USING ASTM D5185 METHOD:-(a) WEAR METALIC PARTICALS OF FE, CR, NI, AL, CU, SN, PB AND AG TO BE ANALISED IN TERMS OF PPM IN THE GIVEN SAMPLES OF LUB OIL.(b) CONTAMINANTS OF SI, NA AND MG TO BE ANALISED IN TERMS OF PPM IN THE GIVEN SAMPLES OF LUB OIL. | 150 | Times | 3,500 ₹5,25,000 Lowest |
| 7.00 | (B)COOLANT TEST / FRESH WATER ADDITIVE TEST:- THE FOLLOWING PARAMETERS TO BE ANALYSIS FOR GIVEN SAMPLE:(i) PH VALUE(ii)CHLORIDE CONTENT(iii) PERCENTAGE OF INHIBITOR(iv) HARDNESS(v) ANY OTHER TEST REQUIRED. | 30 | Times | 1,500 ₹45,000 Lowest |
| 8.00 | (C) POTABLE WATER TEST TO BE CARRIED OUT TO ACERTAIN THE SUITABLITY FOR DRINKING WATER | 25 | Times | 3,500 ₹87,500 Lowest |
| 9.00 | ANALYSIS OF LUBE OIL, COOLANT, HYDRAULIC OIL AND PORTABLE WATER OF ALL MAIN ENIGNES, DAs, GEAR BOXES, AUXILIARY MACHINERY, DECK HANDLING GEAR TO BE CARRIED OUT THORUGH NABL CERTIFIED LAB AND TWO COPIES OF EACH REPORT TO BE SUBMITTED WITHIN 24 HRS OF TEST UNDERTAKEN. PAYMENT AT ACTUALS(A) LUBE OIL TEST BY USING METHOD OF ASTM D445(i) VISCOSITY @ 400C (CST)(II) VISCOSITY @1000C DEGREE (CST)(III) VISCOSITY INDEX (CALCULATED)(B) WATER CONTENT (% BY VOLUME) BY ASTM D95 METHOD(C) FLASH POINT BY ASTM D95 METHOD(D) TBN (MG KOH/G) BY ASTM D644 METHOD(E) TAN (MG KOH/G) BY ASTM D644 METHOD(F) COOLANT TEST/ FRESH WATER ADDETIVE TEST. FOLLOWING TO BE ANALYSED:(I) PH VALVE(II) CLORIDE CONTENT(III)PERCENTAGE OF INHIBITOR(IV) HARDNESS(G) PORTABLE WATER TEST TO BE CARRIED OUT TO ASCERTAIN SUITABILITY OF DRINKING WATER. | 1 | LS | 10,000 ₹10,000 Lowest |
| 10.00 | (E) PROVISION OF CONTAINERS/ SAMPLE BOTTLES: - STANDARD CONTAINERS/ SAMPLE BOTTLES (CAPACITY OF 250 ML, QTY 300) TO BE PROVIDED BY VENDOR FOR LANDING THE SAMPLES OF LUB OILS, COOLANTS, HYDRAULIC OILS ETC FOR ANALYSIS. PAYMENT AS PER ACTUALS. | 300 | NOS | 250 ₹75,000 Lowest |
Tender Value
Refer Docs
Closing Date
20 May 2026, 11:00 amClosed
M(SRC-OS)
HSL
CHEMICAL ANALYSIS OF SAMPLES ON INS PROJECT
2026_HSL_99452_1
SR COMPLEX/PRODUCTION/OUT SOURCE REQUISITION/2025/926
Open Tender
Miscellaneous Services
Service
30 days
VISAKHAPATNAM
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
15 Jun 2026
4 May 2026
20 May 2026
4 May 2026
20 May 2026
4 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | CPP AND SHAFTINGWARTSILA/4E1540R-HB TYPEMT - 271101 O1
Sample oil from the hub and undertake analysis.Details of Oil - HLP 46, | 1 | NOS | - | - |
| 2 | STEERING GEAR SYSTEMMAKE/ MODEL - VELJAN HYDRAIR P11P2R1C4A2BMT - 430102 SR4
Carry out chemical analysis | 1 | NOS | - | - |
| 3 | ANALYSIS OF LUB OIL, COOLANT, HYDRAULIC OIL AND PORTABLE WATER. PAYMENT AT ACTUALS ANALYSIS OF LUB OIL, COOLANT AND PORTABLE WATER OF ALL MAIN ENGINES, DIESEL ALTERNATORS, GEAR BOXES AND AUXILARY MACHINERIES TO BE CARRIED THROUGH NABL CERTIFIED LABORATRY AND TWO COPIES OF EACH REPORT TO BE SUBMITTED WITHIN 24 HOURS OF TEST UNDERTAKEN. | 1 | LS | - | - |
| 4 | (A) LUB OIL TEST(I) BASIC TEST:- THE BASIC TEST OF LUB OIL SHOULD COVERS THE FOLLOWING:-(a) BY USING METHOD OF ASTM D445 :- (aa) VISCOSITY @ 40 DEGREE C (CST) (ab) VISCOSITY @ 100 DEGREE C (CST) (ac) VISCOSITY INDEX (CALCUATED) | 75 | Times | - | - |
| 5 | b) WATER CONTENT (% VOL) BY ASTM D95 METHOD.(c) FLASH POINT ( DEGREE CENTIGRADE) BY ASTM D92 METHOD(d) TBN (MG KOH/G)) BY ASTM D644 METHOD(e) TAN (MG KOH/G)) BY ASTM D644 METHOD | 1 | LS | - | - |
| 6 | (II) ADVANCE TEST :- THE ADVANCE TEST OF LUB OIL SHOULD COVERS THE FOLLOWING BY USING ASTM D5185 METHOD:-(a) WEAR METALIC PARTICALS OF FE, CR, NI, AL, CU, SN, PB AND AG TO BE ANALISED IN TERMS OF PPM IN THE GIVEN SAMPLES OF LUB OIL.(b) CONTAMINANTS OF SI, NA AND MG TO BE ANALISED IN TERMS OF PPM IN THE GIVEN SAMPLES OF LUB OIL. | 150 | Times | - | - |
| 7 | (B)COOLANT TEST / FRESH WATER ADDITIVE TEST:- THE FOLLOWING PARAMETERS TO BE ANALYSIS FOR GIVEN SAMPLE:(i) PH VALUE(ii)CHLORIDE CONTENT(iii) PERCENTAGE OF INHIBITOR(iv) HARDNESS(v) ANY OTHER TEST REQUIRED. | 30 | Times | - | - |
| 8 | (C) POTABLE WATER TEST TO BE CARRIED OUT TO ACERTAIN THE SUITABLITY FOR DRINKING WATER | 25 | Times | - | - |
| 9 | ANALYSIS OF LUBE OIL, COOLANT, HYDRAULIC OIL AND PORTABLE WATER OF ALL MAIN ENIGNES, DAs, GEAR BOXES, AUXILIARY MACHINERY, DECK HANDLING GEAR TO BE CARRIED OUT THORUGH NABL CERTIFIED LAB AND TWO COPIES OF EACH REPORT TO BE SUBMITTED WITHIN 24 HRS OF TEST UNDERTAKEN. PAYMENT AT ACTUALS(A) LUBE OIL TEST BY USING METHOD OF ASTM D445(i) VISCOSITY @ 400C (CST)(II) VISCOSITY @1000C DEGREE (CST)(III) VISCOSITY INDEX (CALCULATED)(B) WATER CONTENT (% BY VOLUME) BY ASTM D95 METHOD(C) FLASH POINT BY ASTM D95 METHOD(D) TBN (MG KOH/G) BY ASTM D644 METHOD(E) TAN (MG KOH/G) BY ASTM D644 METHOD(F) COOLANT TEST/ FRESH WATER ADDETIVE TEST. FOLLOWING TO BE ANALYSED:(I) PH VALVE(II) CLORIDE CONTENT(III)PERCENTAGE OF INHIBITOR(IV) HARDNESS(G) PORTABLE WATER TEST TO BE CARRIED OUT TO ASCERTAIN SUITABILITY OF DRINKING WATER. | 1 | LS | - | - |
| 10 | (E) PROVISION OF CONTAINERS/ SAMPLE BOTTLES: - STANDARD CONTAINERS/ SAMPLE BOTTLES (CAPACITY OF 250 ML, QTY 300) TO BE PROVIDED BY VENDOR FOR LANDING THE SAMPLES OF LUB OILS, COOLANTS, HYDRAULIC OILS ETC FOR ANALYSIS. PAYMENT AS PER ACTUALS. | 300 | NOS | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.00 MB
Tender_documents.rar
Tender Documents • 0.56 MB
BOQ_109041.xls
BOQ • 0.27 MB
DUE_DATE_EXTENSION.pdf
PDF • 0.17 MB
DUE_DATE_EXTENSION.pdf
PDF • 0.17 MB
DUE_DATE_EXTENSION.pdf
PDF • 0.17 MB
DUE_DATE_EXTENSION.pdf
PDF • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .