Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.5 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L1 | Accepted-AOC LOWEST AND REASONABLE RATE | |
| 2 | L2₹52.5 L+₹1.3 L (2.46%)Rejected-Finance | L2 | Rejected-Finance HIGHER RATE | |
| 3 | L3₹52.5 L+₹1.3 L (2.62%)Rejected-Finance | L3 | Rejected-Finance HIGHER RATE | |
| 4 | L4₹52.7 L+₹1.5 L (2.89%)Rejected-Finance | L4 | Rejected-Finance HIGHER RATE | |
| 5 | L5₹52.9 L+₹1.7 L (3.40%)Rejected-Finance | L5 | Rejected-Finance HIGHER RATE |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
30 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY
BHUJ
COMPREHENSIVE MAINTENANCE FOR AGE BR III AT MIL STN GANDHIDHAM UNDER GE A BHUJ
2024_MES_653536_1
8212
Open Tender
Civil Works
Item Rate
270 days
GE ARMY BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE ARMY BHUJ
₹96,000
Yes
31 Aug 2024
11 May 2024
1 Jun 2024
11 May 2024
30 May 2024
24 May 2024
Amount
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises complete all as specified and as directed.
M & L for coloured Glazed ceramic tiles in vertical surface 350x 250x 7mm / 450X 350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified and directed.
M & L for Non Skid coloured ceramic tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for coloured joint free non skid tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for coloured joint free non skid tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in vertical surfaces such as skirtings, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm,n vertical surfaces such as skirtings, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons,dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site complete all as specified & directed.
M & L for granite (of any colour) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform, counter for wash basin, flooring and all other similar works complete all as specified and directed.
M & L for granite (of any colour) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including grinding and polishing as in skirting, steps risers, wall dado and similar works a and all other similar works complete all as specified and directed.
M & L for 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor finishes like tiles etc complete all as specified and directed.
M & L for rendering 10 mm thick in CM (1:4) on fair faces of brick work complete all as specified and directed.
M & L for 20mm thick screed bed or bedding layer in cement mortar (1:4) for laying floor finishes like tiles etc complete all as specified and directed.
Taking up or down steel tubing / CPVC Pipes of size 16 mm bore and connection including cleaning for refixing or removed to store complete all as specified and directed.
Taking up or down steel tubing / CPVC Pipes of size 20 mm bore and connection including cleaning for refixing or removed to store complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors of OUTER DIAMETER sizes of 16 mm bore complete all as specified & directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors of OUTER DIAMETER sizes of 20 mm bore complete all as specified & directed.
M & L for Cutting chases, pinning in making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good,cutting n, exc. 10cm girth complete all as specified and directed.
S & F in repairs 10 litre capacity PVC low level flushing cistern with all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete all as specified and directed.
S & F in repair PVC connection 15mm size PTMT nuts of length 450 mm complete all as specified and directed.
S & F in repair 15 mm bore fancy type angular valve cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repair of two way angle cock chromium plated fancy type 15 mm bore complete all as specified and directed.
S & F in repair of two way bib cock chromium plated fancy type 15 mm bore complete all as specified and directed.
S & F in repair 15 mm bore fancy type bib taps long body cast copper alloy chromium plated, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs to health faucet with 1200 mm long flexible mild steel tube 80 mm dia with wall hook complete all as specified and directed.
S & F in repair CP Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S & F in repairs acrylic shelf having size of 56 cms x 13 cms with chromium plated bracket below WHB mirror complete all as specified and directed.
S & F in repairs 15 mm bore overhead shower Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or unioncomplete all as specified and directed.
S & F as in repair grating round 150mm size of PTMT (minimum 100 gms) with waste hole of PTMT complete all as specified and directed.
S & F in repair 15 mm bore pillar taps cast copper alloy,with capstan heads,chromium plated,screwed down, fancy type, high pressure, with or without lettred 'HOT or COLD' with long screwed sunk and fly nuts complete all as specified and directed.
S & F in repair CP wall mixer 3 in 1 System with provision for hand shower and over head shower and including 1.5m long tele shower screwed for iron pipe or CPVC Pipes or for brass ferrule and fixed complete all as specified. (Make : Jaquar Queen Series Cat Part No - QQT - 7281 or equivelant)
S & F in repair for fancy type 15 mm bore central hole basin mixture with 'U' shaped round casted spout with 3" long pipe connection with aerator complete all as specified and directed.
S & F in repairs Tubular towel rail, 20mm dia, D type, 60cm long between flanges brass chromium plated complete all as specified and directed.
S & F in repairs CP Towel Ring round with round flange and not less than 280 gms complete all as specified and directed.
S & F in repairs CP Toilet Paper holder all as per cat part complete all as specified and directed.
Demolition of precast concrete block walling and similar items i.e. ashlar facing dressing stone work, precast concrete articles etc of any description and in any position built in cement mortar including all quoins, arches and pillars etc and disposing off rubbish) off the premises of cantonment
M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in Modular bricks in cement mortar 1:6 including curing,racking of joints etc. complete all as specified & as directed.
Taking down cement plaster of any description from brick wall or concrete surfaces including racking out joints and hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L for 15 mm thick plaster in CM (1:6) on brick work / RCC concrete surfaces of wall and finish the surface even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in CM 1:4 on concrete / fair surfaces of block masonary and including mixing water proofing compound as per manufactureres instructions and finished even and smooth without using extra cement complete all as specified and directed. Note :- Water proofing compound shall be measured and paid for seperately under appropriate item of Sch "A' as supply only
Supply only Liquid water proofing compound complete all as specified and directed.
M & L for 5 mm thick plaster in CM (1:3) on brick work / RCC concrete surfaces of ceilings complete all as specified and directed.
M & L for preparation of newly plastered ceiling surfaces and applied three coats of white wash complete all as specified & directed.
M & L for preparation of newly plastered wall surfaces and applying two coats of cement based paint complete all as specifed and direcetd.
M & L for preparation of newly plastered wall surfaces and applying two coats of distemper oil emulsion over a coat of alkali resistant priming paint complete all as specifed and direcetd.
M & L for preparation of newly plastered wall surfaces and Providing and applying 3mm thick wall care putty on wall to prepare the surface even and smooth. and Material and labour for two coats of distemper oil emulsion white or tinted including priming plastered and other surfaces with alkali resistant priming paint complete all as specified and directed.
M & L for preparation of newly plastered wall surfaces and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
Demolition and breaking up drain pipes upto 100/110 mm dia (Salt glazed ware, AC, PVC or reinforced concrete) set in cement mortar complete all as specified and directed
Demolition and breaking up drain pipes upto 75 mm dia (Salt glazed ware, AC, PVC or reinforced concrete) set in cement mortar complete all as specified and directed
Supply and fixing of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall with suitable clamp complete all as specified and as directed.
Supply and fixing of 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall with suitable clamp complete all as specified and as directed.
Supply and fixing of PVC (SWR) junction single, (single T) equal or unequal provided with access door suitable for 110mm bore PVC pipes complete all as specified and as directed.
Supply and fixing of PVC (SWR) bends any radius suitable for 110mm bore PVC pipes with access door complete all as specified and as directed.
Supply and fixing of PVC (SWR) bends any radius suitable for 75mm bore PVC pipes with access door complete all as specified and as directed.
Supply and fixing of PVC (SWR) vent cowl for 110mm bore PVC pipes complete all as specified and as directed.
Supply and fixing of PVC (SWR) WC connector bent type for 110mm bore PVC pipes complete all as specified and as directed.
Supply and fixing of PVC (SWR) for 75mm Diameter of outlet floor trap, plain with grating including jointing with solvent cement etc complete all as specified and as directed.
Supply and fixing of PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed.
Dismantling of water tanks and removing to store having Capacity of Exc 500 litres and n.exc 1000 litres complete all as specified and directed.
Dismantling of water tanks and removing to store having Capacity of Exc 1000 litres and n.exc 2000 litres complete all as specified and directed.
S & F for 500 ltrs capacity rotational moulded polyethelene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
S & F for 1000 ltrs capacity rotational moulded polyethelene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
S & F for 2000 ltrs capacity rotational moulded polyethelene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
S & F in repairs 20 mm bore dia gun-metal,globe or gate valves,with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed.
Excavating in post holes (or similar holes) in soft / loose type of soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed
M & L for PCC Type D2 1:4:8 (40mm graded aggregates)as in foundation, filling and mass concrete complete all as specified and directed.
S & F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S & F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement morter to dwarft wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410 mm x 330mm x 160mm complete all as specified and directed.
S & F in repairs 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S & F in repairs of Bib tap fancy type Bore dia of pipe 15mm standard of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and directed. (Minimum weight 15mm-90gms).
S & F in repairs of Angle Stop valve Bore dia of pipe 15mm standard of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and directed. (Minimum weight 15mm-90gms).
S & F in repairs of Ball valves 15mm dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed. (Minimum weight 15mm-142gms)
S & F in repairs of Ball valves 20mm dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed. (Minimum weight 20 mm-210 gms)
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F of mild steel Fe 410-W (Grade-Fe 250) quality A of Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces and applying two coats of synthetic enamel paint over a coat of primer red oxide, zinc chrome complete all as specified and directed.
S & F in repairs to Harrison rails, anodised aluminium alloy, powder coated with fixing brackets, stops, rollers etc complete all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings of any height complete all as specified and directed.
S & F of Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified including scaffoldings of any height complete all as specified and directed.
Supply & fix of Pre- painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified as directed by manufacturer on steel members including scaffoldings of any height complete all as specified and directed.
Dismantling of structural steel work including doors, gates but excluding framed truss etc.complete all as specified and directed.
S & F for joist, channel, angle,or tee sections, or MS Flats fixed independantly without connecting plates,etc Fe 410-W (Gde-E- 250) quality- A (cut to ordinary lengths i.e within 20mm of length indicated) as in frame work for Galvalume / CGI chajjas complete all as specified and directed.
S & F of structural steel work in tubular/square tubular trusses including special shaped washer, gusset/bearing plate etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and directed.
M & L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M & L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
S & F of 1.00 mm thick MS plain, black sheet in wall cladding, steel gates and all other similar work complete all as specified and directed.
Taking down of chowkhats / frames n exc 1.50 sqm each without taking off shutter each complete all as specified and directed.
Taking down of chowkhats / frames exc 1.50 Sqm but n exc 4.0 sqm each without taking off shutter each complete all as specified and directed.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings complete all as specified and directed.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass / stainless steel screws all complete as per architectural drawings complete all as specified and directed.
S & F of 5.5mm thick Sheet glass, ordinary quality and glazing sheet glass is ground or obscured or frosted, on one side with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm single piece extruded PVC profiles reinforced with 19 x 19mm MS square tube provided with EPDM rubber gasket weather seal through out the frame and the profile mitre cut at two corners and joined by inserting 2 nos 150mm long brackets of 15 x 15mm MS square tube inside 19 x 19mm MS square tube suitably screwed complete all as specified and directed.
Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes of size 15 x 15mm for top and bottom rails and 19 x 19mm for stiles, MS frame covered with 5mm thick single piece extruded PVC profile 'C' channel having a 5mm thick PVC sheet strip of 20mm width struck inside with solvent cement, forming stiles, and 5mm thick single piece extruded PVC profile for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail; panelling of 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc all as per manufacturer's instructions and drawings as shown in SSR Part-I 2009 complete all as specified and directed.
Taking Down of any type of Door Shutters of any description area exc 2 sq.m each complete all as specified and directed.
Taking Down of any type of Door Shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed.
S & F of Factory made wire gauzed PVC door shutter 30 mm thick, i.e. panel will be of wire gauzed in lieu of wood grain printed PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC sheet and PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (90 Deg) used instead of exposed portion of PVC sheet beading. suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
S & F of 30 mm thick flush shutter, solid core construction,with block board core and plywood face panel, commercial type on both sides complete all as specified and directed.
S & F in repair 18/19mm thick Block boards, grade 1 quality, exterior grade, decorative type with decorative face veneer on one face, as in cupboard shelves and cupboard shutter fixed with screws to timber frame work with 1st class hard wood leaping all around complete all as specified & directed.
S & F of aluminium anodised 200 mm barrel tower bolts of extruded section complete all as specified and directed.
S & F of 150mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F of 100 mm butt hinges extruded aluminium alloy with galvanized mild steel hinges pin anodised type `C'-22 complete all as specified and directed.
S & F of mild steel 300 mm, ordinary rat tail rod pattern springs, including roler and roller plate complete all as specified and directed.
S & F of 300mm long aluminium alloy, anodised sliding door bolt with haps, staple(bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
S & F of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F in repairs of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
Demolition of cement concrete of any description and in any position (unreinforced) in ground floors/ paving/plinth not exceeding 15 cm thick (below or above GL) complete all as specified and directed.
M & L for cement concrete type C-2, 1:3:6 (40mm graded aggregate), 75mm thick. as in plinth protection finished even and smooth without using extra cement including expansion joints complete all as specified and directed.
Demolition of ceiling boards of any description, and any thickness including cover fillets and frame work complete all as specified and directed.
M & L for powder coated aluminium snap grid having a size of 605mm x 605mm and sections incorporated in frame work shall conform to IS 733, IS 737 and IS 1285 and snap grid frame work shall be fixed to ceiling with supporting hanger 6mm dia mild steel rod, J bolts with necessary bolts, nuts and washers all as per manufacturer's instruction. The main & cross tees shall be jointed at junction/crossings with anodized aluminum angle bracket of size 19.05mm x 19.05mm x 1.45mm, weighing 0.14 Kg per RM, fixed with suitable mild steel, bolts nuts and washer all as per manufacturer's instruction, the snap grid shall be supported at ends all along the wall with anodized aluminum angle of size 38mm x 25mm x 2.18mm, weighing 0.358 Kg per running meter complete all as specified and directed.
S & F of 9mm thick PVC laminated gypsum ceiling tiles size of 600mm x 600mm, square edge, front side laminated PVC and back side aluminium foil complete all as specified and directed. (Frame work for ceiling shall be measured and paid separately).
S & F in repairs of PTMT Mirror cabinet of size 600 x 450 x 200 mm with all necessary arrangements for fixing to walls complete all as specified and directed.
S & F in repairs of stainless steel kitchen plate rack size 750 x 600 x 250 mm & 0.63 mm thickness of grade AISI 304 incl suitable arrangements for hanging to wall complete all as specified and directed.
S & F of 125 mm hasp and staplees, safty type aluminium anodised with MS hinges pin incl bolt to hing plate and fixed with screw complete all as specified and directed.
S & F of 75 mm long aluminium handles, cast type, anodised complete all as specified and directed.
S & F in repairs aluminium (extruded section) body door closer hydraulically regulated designation No 3, universal type,suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kg complete all as specified and directed.
S & F in repairs for floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring overall length of cover plate 140 mm, complete all as specified and directed.
S & F of floor door stopper of aluminium alloy body and tongue, anodised , with hard drawn steel spring overall length of cover plate 140 mm, complete all as specified and directed.
M & L for preparation of new wooden surfaces of any description, not otherwise described,over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary paint tint) (each coat) over a coat of pink primer including scafoldings of any hieght complete all as specified and directed.
Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc, including making good breakages in taking out and handling removing to store & Supply and fixing 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed.
Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc, including making good breakages in taking out and handling removing to store & Supply and fixing 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square exceeding 0.5 sqm in each pane complete all as specified and directed.
S & F in repairs 50 micron coloured powder coated aluminium decorative grill design No DG-117,10 mm thick including F Sections complete all as specified and directed. Make :- M/s Deco grill / M/s Royal grill or Equivalent
Preparation of old decorated surface of wall and including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove all loose scales, and foreign materials scarping down, smoke soot moulds , moss and efflorescent salts treating oil and greasy spots and Material and labour for applying one coat of white wash on wall surface complete all as specified and directed.
Preparation of old decorated surface of ceiling and including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove all loose scales, and foreign materials scarping down, smoke soot moulds, moss and efflorescent salts treating oil and greasy spots and applying one coat of white wash on ceiling surface complete all as specified and directed.
Preparation of old decorated plastered or unplastered surfaces of wall including washing, rubbing down and stopping of distempered surface Material and labour for applying one coat of distemper oil emulsion paint white or tinted complete all as specified and directed.
Complete removal of existing treatment and Materials and labour for applying two coats of oil bound distemper over a coat of alkali resistant priming paint all as specified and directed.
Complete removal of existing treatment on wall (any number of layers) by scarping with steel scrapers or any other mean including filling depressions of scrapped surface with putty and Providing and applying 3mm thick wall care putty on wall to prepare the surface even and smooth. and Material and labour for two coats of distemper oil emulsion white or tinted including priming plastered and other surfaces with alkali resistant priming paint complete all as specified and directed.
M & L for Preparation of old painted surface of wood and wood based material any description and in any position over 10 cm width or girth and Material and labour for applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for Preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparation of old decorated surface of wall and including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove all loose scales, and foreign materials scarping down, smoke soot moulds, moss and efflorescent salts treating oil and greasy spots and Material and labour for applying one coat of cement base paint including watering and curing of surface adequately before and after application of cement base paint complete all as specified and directed.
Preparation of old painted surface of concrete and concrete based materials of any description and in any position over 10 cm width or girth and Material and labour for applying one coat of synthetic enamel paint on concrete surfaces complete all as specified and directed.
Complete removal of existing treatment on wall (any number of layers ) by scarping with steel scrapers or any other mean and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
Taking down unserviceable Ceiling/ Exhaust fan from different locations of OTM and md accn and refixing after complete repair at contractor's workshop and at site all as specified. Note : (i) All parts which are to be replaced by new one shall measured & paid separately as "supply only' under appropriate item of Sch 'A'. (ii) Charges for transportation deem to be included in the quoted rate. (iii) Repaired fans to be tested for entire satisfaction of Engr-in-Charge
(a) Rewinding of motor of ceiling fans 1200/1400 mm sweep after removing of old burnt-out windings of electric fans of any description with appropriate size super enameled copper wire as approved by the Engineer-in-charge
(b) Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , assembling and testing complete all as specified.
Supply only bearing of celling fans for celling fans of 1200/1400mm sweep suitable for different makes /type of fans complete all as specified and directed.
Supply only ball bearing suitable for exhaust fan 300 to 450mm sweep of different make complete all as specified and directed.
Supply only rubber reel type synthetic rubber with 14.5 mm hole suitable for hooks of celling fans, complete all as specified and directed.
Supply only nuts, bolts and washers of appropriate size for hanging of celling fan including split pins of galvanished iron 1/8" dia, 2" lengthall as specified and directed.
Supply only down rod 30cm long made out of heavy grade MS pipe with necessory threading at both ends holes as required with suitable matching colour of ceiling fan 1200/1400mm complete all as specified and directed.
Supply only condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFD complete all as specified and directed.
Description all as per item No 7 here - in - before but capacity 4 MFD for exhaust fan of approved make and quality complete all as specified and directed.
Supply only fan blade made out of M S sheet suitable for any make, sweep and colour of celling fans complete all as specified and directed.
Supply only fan blade (set of three), complete with tightening bolts/screws, made of suitable for any make and colour of exhaust fan complete all as specified and directed.
M&L for Painting of celling fan 1200/1400mm sweep AC 230 volts single phase complete in site or at contractor workshop with synthetic enameled white/maching paint by spraying one coat including filling of cavities after cleaning all dust complete all as specified and directed.
M&L for taking down desert coolers of capacity 4000/5000 cfm/hours of any make and repair/ replacement of unserviceable parts including cleaning after complete of repair work all as specified and directed. Note : (i) The unserviceable parts shall be measured and paid separately as "supply only" under appropriate item of sch "A". (ii) Labour charges for repair, replacement and fixing of items is deemed to be included in quoted rate.
S&F in replacement Submersible PVC pump for desert cooler 230 volt single phase 50 HZ complete all as specified and directed.
S&F in replacement of fan motor copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed.
Supply & replacement of wood wool pad ( Set of three) heavy duty for desert cooler complete all as directed.
Supply & fixing in replacement of capacitor suitable for desert cooler of make Usha/Universal/Epcos complete all as specified and directed.
Supply & fixing in replacement desert cooler fan blades made of galvanised iron sheet of appropriate thickness complete all as specified and directed.
S&F in replacement of 3 Pin Top, 5 Amp for desert coolers, complete all as specified and directed.
Disconnecting electrically and mechanically the unserviceable geyser of any description, any capacity and make/type and in any position for repair/replacement/ painting/ cleaning etc including disconnecting existing cold & hot water pipe connections, strip opening of geyser for descaling of tank, replacement of unserviceable parts reassembling the same after repair complete all as specified and directed. Note : U/s parts replaced with new one shall be measured and paid for separately as "Supply only" under appropriate item of Sch "A"
(a) Apparatus plate heavy duty rubber gasket suitable for 03/06/25 Ltr of any size complete all as specified and directed.
(b) Geyser element 1.5 KW, all as specified. Make :- Theata/Venus
(c) Geyser element 2.0 KW, all as specified. Make :- Theata/Venus
(d) Thermostate switch ISI Marked.
(e) S/S inner tank Capacity 25 Ltrs heavy duty .
(f) S/S Copper inner tank capacity 06 ltr heavy duty .
(g) Indicator lamp of any type/colour.
(h) CP connection 450mm long nylon braided and double flat with nut and washers both side complete all as specified.
(j) -do- but of size 300mm long.
(k) Copper flexible cable PVC insulated 3 core 40/.0076 All as specified and directed.
(l) Pressure release valve ISI marked.
(m) Safty plug of geyser for 25/35/50 Ltr capacity.
(n) Plug top 3pin 15 Amps ISI Marked .
(o) Non return valve 15mm dia pipe brass made ISI marked.
Labour only for repairing and attending the complaint of Split/WindowAC/ Water cooler/Refrigerator/deep freezer by highly skilled tradesman and carryout minor repair and making functional complete all as specified and directed at site. Note :- (replacement of spare part will be measured and paid separately under appropriate items )
Disconnecnting, dismantling and taking out the non functional Air Conditioner window type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay, cleaning and servicing of the AC with using caustic soda/detergent powder solution, incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
-ditto- as per item No 156 here-in-above but Split type Air conditioner of capacity 1.5 Ton/ 2.0 Ton
Taking down defective /unserviceable AC compressor of any make of capacity 2.0 TR and S&F compressor sealed unit suitable for 2.0 TR Capacity for any type of window AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 1.5 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of Split AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 2.0 TR and S&F compressor sealed unit suitable for 2.0 TR Capacity for any type of Split AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure complete all as specified and directed for the following appliances:-
(a) Split type AC 1.5/2 Ton capacity
(b) Window type AC 1.5/2.0 Ton capacity
(c) Water coolers 40 to 150 ltrs capacity
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only capacitors of the following capactities for Acs, water coolers, refrigerators, Deep frizers etc as per site requirement :-
Supply, installation including brazing, jointing copper tubing superior quality of dia 5/8” completes all as specified and as directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/2” completes all as specified and as directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 3/8” completes all as specified and as directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/4” completes all as specified and as directed.
M&L for shifting of split type AC from one location to other location including fixing evaporator unit with gitties/fastner, cutting wall/concrete incl arrangement of T&P for laying copper tubing, positioning condensing unit, laying copper tubing incl brazing work, connecting drain pipe, making good disturbed surface complete all as specified and as directed. (Note- Any additional copper tubing required for the work is included in the item)
S&F in replacement of remote control ( micro- processor) unit suitable make of split type AC 1.5/ 2 TR complete all as specified and directed.
Supply only condenser unit of the following appliances including making of all connectiions as specified and directed by Engr-in-charge following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only cooling coil of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only internal wiring kit complete sutaible for following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Water coolers 40 to 150 ltrs capacity.
(c) Split type AC of any make and capcity 1.5/2 ton.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of any make & cap 200 to 425 ltrs capacity.
Supply only condenser fan motor complete with necessary mounting bracke to and base frames for :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Water coolers 40 to 150 ltrs capacity.
(c) Split type AC of any make and capcity 1.5/2 ton.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of any make & cap 200 to 425 ltrs capacity.
Supply only heavy duty PVC flexible pipe with necessary jubilee clamps for water cooler/split ACs/Window ACs drains of size :-
(a) 15mm dia bore.
(b) 20 mm dia bore.
Supply only PCB of split type AC Cap 1.5/ 2 TR as per existing make and model. Complete all as specified and directed.
Supply only air filters of split type AC of 1.5/2.0 TR capacity as per existing pattern, complete all as specified and directed.
Supply only new coling fan motor for window type AC1.5TR/2TR, complete all as specified and directed.
Supply only new cooling fan motor for split type AC of 1.5/2.0 TR capacity, complete all as specified and directed.
Supply and fixing in replacement to worn out outdoor unit of split type AC of cap 2 TR. comprises of condensor, condenser motor, condensor fan and blade , capacitor, suction, discharge valve, outer cover duly powder coated all as specified and as directed.Make Voltas/ LG.
Supply and fixing in replacement to worn out indoor unit of split type AC of cap 2 TR. comprises of condensor, condenser motor, condensor fan and blade , capacitor, suction, discharge valve, outer cover duly powder coated all as specified and as directed.Make Voltas/ LG.
Taking down defective /unserviceable water cooler (capacity 40 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed.
Taking down defective /unserviceable refrigarator (upto capacity 260 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed.
Taking down defective /unserviceable Refrigrator (upto capacity 320 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed.
Taking down defective /unserviceable Deep frizer (capacity upto 425 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed.
M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation complete all as specified and as directed.Note :- (replacement of spare part will be measured and paid separately under appropriate items)
(a) Water coolers 40 to 150 ltrs cooling capacity
(b) Refrigerator of 165 to 310 ltrs capacity.
(c) Deep freezers of Upto 425 ltrs capacity.
S&F in repair decorative box type fitting with LED tube 20 watt for 230 volt AC complete including making all connection using 1.5 sqmm copper conductor muilstranded PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit complete all as specified and directed.
S&F in repair LED Security light fitting made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDs inbuilt electronic driver up to 10 KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT3000-6000 CRI greater than 70, input power 35 watt with 100 lumens per watt output operating voltage 160-260V with connection by three core PVC insulated multistranded copper conductor sheathed cable of size 1.0 Sqmm fixed with & including bracket made of GI Pipe 40mm bore light grade , 1.5 Mtr long bend to shape required with 2 Nos MS clamps of suitable size and length, nuts & bolts complete with IP-65/66 protection complete all as specified and directed.
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 6 Sqmm solid aluminium conductorcomplete all as specified and directed.
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated copper conductor, 3 core, 1.5 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed.
Notes- Applicable for Items from No.01 to No.133:-
(a) Establishment of complaint cell:- (i) Complaints cells will be established at AGE B/R GANDHIDHAM Office (As per locations given by Engineer-in Charge/GE). The numbers of complaints cells in the ibid contract will be One only. (ii) Contractors will deploy manpower/tradesman with requisite tool & plant for smooth functioning of complaint cell under subject work. The details per complaint cell is as given below :- (aa) Data Entry Operator - 01 complaint cell. (ab) Supervisor - As required for management of all the complaint cell under subject tender in consultation with GE/Engr-in charge. (ad) Tradesmen & Helpers - As required for management of all the complaint cell under subject tender in consultation with GE/Engr-in-Charge and will be present in all complaints cells. The numbers of the tradesman shall be adequate to address all the complaints on daily basis. (ae) The Data Entry Operators and Supervisors will be deployed from 9AM to 5 PM on all complaint cell to manage the complaints cell.
(a) Establishment of complaint cell (Contd):- (iii) The contractor will provide compatible computer system, printers, peripheral, consumables, internet connection/Dongle for each complaint cell alongwith requisite furniture for functioning of complaint cell and storage of store as required. (iv) (A)The complaints in the cell will be received through complaint register / site orders book / Verbally / Telephonically / Mobile or any other mode/system as evolved and intimated by JE/Engr-in-Charge. (B) One of the system of complaint receiving is by generating QR CODE at each block /buindings comes under AOR of AGE B/R - II and Cost required for developement of QR CODE will be included by contractor in this item no extra payment will be provided during execution by the departement all as directed by Engr-in-Charge. The contractor shall take immediate action to register and attend all the complaints. (v) The complaints will be addressed through complaint slips and contractors will prepare abstract of all the complaints received and action taken thereof on daily basis and will submit to JE/Engr-in-Charge.
(vi) Dress Code:- (aa) Deployed manpower/tradesmen to attend and resolve the complaint shall wear proper uniform. Dress code for plumber, carpenter, scavenger and Electrician etc. shall be approved by Engr-in-Charge with monogram/badges which shall be fixed on the dress. (ab) The number of workers shall be increased based upon number of complaints and quantum of work involved during working hours as decided by JE/Engr-in-Charge.
(viii) T&P :- (aa) The contractor is responsible to provide all T& P to all the manpower deployed, items such as Drill Machines, cutters, welding machines, scaffoldings etc as and when required at site. (ab) Any other misc works/services connected with user facilitation as per direction of Engr-in-Charge. (ac) The responsibility of taking the tradesmen to complaint site will be of contractor. (ix) Sign Boards :- For each complaint cell, adequate flex sign board of approved size will be placed in complaint cell by contractor. The content of the flex board will be approved by Engr-in-Charge/GE.
(x) All Taking Down for fixing new items will be included in the rates
(b) Penalty Clause Contractors will pay penalty on account of non addressal of complaints in given time frame as per matrix given below. The penalty will be levied by Engr-in-Charge/GE after ascertaining the time taken to address the complaints and justifiable delay, if any. The penalty matrix for each complain is as given below :- PENALTY Time delay For Plumber : Less than 24 hrs Nil 24 hrs to 48 hrs Rs. 25 48 hrs to 72 hrs Rs. 50 72 hrs and more Rs. 75 For Carpenter : Less than 48 hrs Nil 48 hrs to 72 hrs Rs. 25 72 hrs and more Rs. 75 For Mason : Less than 72 hrs Nil 72 hrs to 96 hrs Rs. 25 96 hrs and more Rs. 75
(c) Management of urgent nature of complaints such as leakage, water over flow, sewage, Airlock leakage on holiday and after 5 PM till 9 AM everyday will also be the responsibility of contractor. For the same adequate tradesman and helper of lack type etc will be made available in each complaint cell by the contractor. (d) All above aspects shall deemed to have been included in the quoted price by the contractor. (e) Recovery on non wearing of uniform :- The employee and labourers engaged by the contractor under this contract shall wear neat and clean uniforms as approved by Engineer-in-Charge along with name badges, else recovery shall be made @ Rs 50/- per person per day. (f) The quoted rates shall be deemed to be included of all provisions mentioned above. The decision of accepting officer in this regard shall be final and binding and without prejudice to all. No claim/representation shall be entertained in the subject matter.
(h) The adequet no of workers as required per day to address the day to day maintenance works shall be deployed by contractor.
Notes- Applicable for Items from No.134 to No.188:-
(1) The contractor shall keep all items readily available at site, which is required for urgent repair works.
(2) In case of absence of manpower without providing suitable replacement, an amount of Rs 1000/- per day shall be recovered as liquidated damage per person per day from the bill.
(3) Common miscellaneous material such as screws any type, nails, washers, insulation tapes, clamps, hooks, which are required for the work the cost of which is deemed to be included in quoted rate.
(4) All tools &tackles, plants, machineries, equipment and material to carry out the work at site which is to be decided by GE (A) Bhuj shall have to be provided by the contractor at his/ her own cost.
(5) Contractor’s supervisor (electrical engineer) should be available at the site to supervise the works and co-ordinate with the officials.
(6) The electrician on duty round the clock will have to be available at the site service centre created by the contractor & should have mobile phone. In case of absence of electrician, Rs 500/- will be levied as penalty for each instance.
(7) The manpower shall be issued identity card after getting due verification. Uniform should be worn by the manpower having monogram of the firm.
(8) The skilled worker should be facilited with mobile phone to contact on urgent tasks & their numbers should be displayed at various places and forwarded to administration.
(9) The contractor shall ensure safety of his workers and other at site of work and shall be responsible for any consequence arising out of execution of the repair and maintenance works.
(10) The contractor shall ensure that his repair/ maintenance staff is qualified and licensed for their part of work. He shall be responsible for their conduct. The contractor shall be held responsible for any loss or damage to employees’ state insurance corporates property.
(11) The date of repair, unit name & serial number shall be mentioned in neat sticker in the appliances after repair.
(12) Contractor is to collect the faulty appliances from units & return them after repair within a week. No separate charges shall be given for transportation.
(13) It is responsibility of contractor to clean the area after repair work of appliances. Rates are deemed to be include in his quoted rates of respective items.
(14) The same nature of complaints in same location/block shall be counted as one complaint in internal electrification. Job card and complaint register for entry of complaints shall be provided at his/ her own cost.
(15) The contractor provide test certificate of material to be incorporated in the work.
(16) Any of contractor persons causes damage of equipment or property of Military station, the contactor will be solely held responsible for the cost of consequences thereof.
(17) Contractor shall carry out all test. The equipments shall conform to Indian standards. 1) IR test. 2) Polarity test. 3) Earth Resistance test etc. The test report after completion testing shall be submitted to the department with duly signed by licensed electrican following current leakage/any fault in wiring. The report shall be given with proper format showing each circuit value of test done. Equipment to be used in testing should be calibrated, date of calibration to be displayed on the equipment and calibration report should be submitted.
(18) Contractor shall identify the real cause of fault of wiring . wiring problems that are identified should be documented.
(19) Work diary & hindrance register shall be maintained by the site engineer of the contractor. The shall be deposited to department daily with duly signed by contractor.
(20) Job card /Docket shall be maintaned properly mentioning as below: a) service Number b) Name c) Rank d) unit e) Date Format of docket/job card shall be provided to contractor. Date of receiving & Date of resolving with time shall be endosrsed on job card.
(21) Joint measurement weekly. The contarctor should be availble for joint measurement along with supervisor on every Wednesday/as decided by Enginner-in-charge.
(22) Stationery such as complaint register, Job card/Docket , work diary ,hindrance register, site order register etc shall be supplied by the contractor
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
Shree Builders
Shreeganesh Construction
Ramdev and Sons
SHUBHAM INTERNATIONAL
Haritwal traders
M/s Bombay Novelty Stores
Jinendra Chemicals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .