| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹6.0 L+₹2,970 (0.50%)Rejected-Finance GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹6.0 L+₹9,505 (1.60%)Rejected-Finance SHOP NO 02 DADA COMPLEX NEAR DENA BANK NALIYA TAL ABDASA KUTCH GUJRAT 370 655 | KACHCHH | GUJARAT | 370655 | L3 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹6.5 L
EMD Value
₹13,000
Closing Date
15 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Asst Garrison Engineer (I) (CG) Jakhau
AGE (I) (CG) Jakhau Military Engineer Services Naliya-Kutch-370655
REPAIR MAINT OF HT LT ELECTRIC PANNEL WITH MISC ALLIED WORKS AT JAKHAU AND CGRA NALIYA ICGS UNDER AGE I CG JAKHAU
2020_MES_345333_1
8045/E8
Open Tender
Civil Works
Item Rate
180 days
JAKHAU
AS PER TENDER PAGES
10 documents required · 10 mandatory
₹500
AGE (I) (CG) Jakhau
₹13,000
Yes
4 Jul 2020
16 May 2020
17 Jun 2020
16 May 2020
15 Jun 2020
29 May 2020
60 days
Amount
Taking down old unsv LT cable and Supply and Laying in trenches or passing through pipe, fixed to wall/pole and duct etc. LT underground electric cable including jointing and testing XLPE insulated armoured heavy duty underground cable, 1100 volt grade, with stranded aluminium conductor for following sizes:-
(a) 240 sqmm, 3.5 core
(b) 95 sqmm, 3.5 core
(c) 70 sqmm, 3.5 core
(d) 50 sqmm, 3.5 core
(e) 25 sqmm, 3.5 core
(f) 16 sqmm, 4 core
(g) 10 sqmm, 2 core
Taking down old unsv HT cable and Supply and Laying in trenches or passing through pipe, fixed to wall/pole and duct etc. HT underground electric cable 3 core 95 sqmm XLPE insulated armoured heavy duty underground cable, 11000 volt grade, with stranded aluminium conductor complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming levelled bottom surface all as specified and directed at site.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
Supplying & laying in repair factory made of unreinforced Precast concrete cover of class LV, type 1, flat, size 250 mm x 150 mm x40mm for protection for cable all as specified .
Supply and laying in repair factory made unreinforced precast concrete cable cover class HV, type 1, flat size 300mm x 180mm x 40mm for HT UG cable laid traverse to cable all as directed.
M&L for Re-laying of Precast concrete cable cover suitable for HT / LT cable for protection purpose retrieved while dismantling HT / LT Cable.
M&L for Re-laying of cable any size in trenches including dismentling of connection from pannel/DB's and after relaying refix the same in its originnal postion complete all as specified and directed.(Note:-Excavation & earth work shall be measured and paid separately under respective item of this Schedule.)
Dry Sand filling in cable trenches for protection of cables with two layers below and above cable and punned down to speicified thickness complete all as specified and as directed. Note: Punned down thickness shall only be measured for payment.
Disconnecting the HT & LT electric connection from the transformer and Opening of all side door and top covers by unscrewing nut, bolts & washers etc and taking out core and coil assembly from inclousure by disconnecting from top Yoke, HT< bushing stud to outside by dismantling the channel of 160KVA/250KVA capacity transformer Indoor/Outdoor complete all as directed.
M&L for replacement of top cover gasket and closing the tank top cover by fixing of suitable size of nut, bolts and washers gasket etc complete in all respect.
M&L for dismentling of breather assembly and replace with new silica gel assembly of 160KVA/250KVA capacity transformer Indoor/Outdoor complete all as directed by engineer-in-charge.
M & L for Repair/ overhauling of complete 160/250 KVA Capacity Indoor/outdoor transformer by dismantling carefully unit and lifting out the core assembly /header , HT/LT coils from limbs and inspection complete including disconnecting cable connection and testing, commissionig all as directed by Engineer-in-Charge. Note:- (The quoated rates also inclusive satisfactory test report of all parameters and transportation charges from AGE E/M store yard to workshop and back to its original location. If repairing Transformer have not to be repaired with in 15 days from the date of handing over to contractor a panel recovery @ Rs 500/- per day will be recoverd from his RAR.)
M&L for repairs for rewinding of HT coils with copper wire super enameled high quality with exiting guage and impedence including requisite insulating paper /material, heating and varnishing in each layer of winding after taking out existing winding of HT coils complete all as directed by Engineer-in-Charge
All as above item No 15 but LT coils with copper strips
S&F in replacement of porcelain transformer bushing on LT side 1100volt including brass stems conical bush and gasket of 160KVA/250KVA capacity transformer Indoor/Outdoor complete all as directed by engineer-in-charge
All as above item No 17 but HT 11 KV
M&L for topping up of transformer oil having die electric strenght not less than 45 KV(at 2.5 m gap) high voltage as per IS specificatio of low viscosity complete all as directed by engineer-in-charge Make:- Powerlink/Power-oil/Savita
M&L labour for alternative arrangement by hiring, transportation of out door/Indoor transformer of capacity up to 160/250KVA in place of unserviceable transformer on hire basis for 15 days including, installation, connection and testing of transformer and return back after installation of repaired transformer complete all as specifed and directed. Note: (i) Repairing of transformer have to be completed within 15 days no extra cost will be paid toward hiring charges beyond 15 days. Moreover contractor shall not be allowed to shift the hired transformer until it is replaced by the repaired transformer. In case any fault/burning/peeling of painting and any other defects occurred in hired transformer the contractor shall have to made good himself from own expenses.(ii) Contractor shall check the available infrastructure and to be sure regarding safety of hired transformer before installation. The rate quoted shall deemed to be include transportation cost, earthing lead etc.(iii) In case the defective transformer not repaired & installaed on its site within the specified period of 15 days from the date of handing over to contractor, a panel recovery @ Rs 1000 /- per day shall be chared from his dues. During this period contractor shall not be allowed to shift the hired transformer until it is replaced by the repaired transformer. No extra cost beyond 15 days shall be paid to contractor on this account.
Supply and fix in repair Aviation obstruction light LED type, colour red, comprising of aluminium housing with polycarbonate enclosure complete all as specified and directed. Make: Bajaj, Model: BGAV 302 LED or its equivalent in Philips/ Wipro/ CG/ Havells
M&L for repairs to existing out door LT panel, removing the unserviceable hinges from doors (1.6mm thick MS), grinding the welded portion, denting and leveling the door, welding suitable new hinges (Approx. 0.50 Kg) to doors including locking arrangement and one coat of synthetic enamel paint (Approx 10 Sq.m.) as that of existing colour complete all as specified and as directed.
S&F in replacement Off load Change over switch, 4 Pole, 200 Amps, 415 Volts, with enclosure fixed to stand madeup of angle iron frame and mounted on floor / PCC floor as per site requirement complete all as specified and as directed.
Material and labour in repair for earthing complete with galvanized earth plate electrode in 60 cm x 60 cmx 6 mm thick buried directly in ground vertically at a depth not less than 2.25 meter below ground level with top edge of earth plate at depth not less than 1.5 mtr below ground level connecting to and including GI strip 32 mm x 6 mm by means of GI bolts, nuts, check nuts and washer light grade 40 mm dia GI protection pipe and connected to equipment, GI pipe medium grade 20 mm dia for watering an including funnel wire mesh, RCC pit cover and PCC 1;2:4 type B-1 including Rocksalt, charcoal, excavation and earth work disposal of surplus soil shown as plate No 3 of SSR part - I 1991 and all as specified complete. Note : - The unit rate quoted shall deemed to have included for GI protection pipe, GI earth strip up to 7.5 mtr, GI water pipe, wire mesh , funnel , excavation, RCC pit cover complete.
M&L for lowering of High Mast lantern to carry out repairs for lights and cables, fittings,gear box servicing ,greasing of motor etc. and raising the lantern to its original position. (Replacement items such as LED Flood light,cable will be measured and paid separately.)
S&F in replacement LED flood light luminaire 150 W with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 protection and connecting up complete all as directed. Make: Havells Model: JETA PROPLUSFL150WLED757LT G or its equivalent in Wipro/polycab
S&F in replacement PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694, 4 core,2.5 Sqmm highmast thrilling cable.
S&F in replacement power AC power contractor of rating 32 Amps, 3 Pole complete all as specified and as directed. Make: L&T, Model MNX 32 AC-3 or its equivalent in Siemens/ Schinder/ C&S
M&L for Cutting of worn out aluminium cable terminal lugs from the HT/LT cable, crimping of new aluminium cable Lugs and fixing with transformer / LT panel terminal studs including cutting/dressing of cable, excavation of surface after providing redressing of excavated surface including providing sand cushioning and brick protection as directed.
Supply, jointing and testing in replacement 11 KV, 3 core cable termination joint (heat shrinkable) suitable for 3 core ,11 KV /UG XLPE cable of following type & size :-
Indoor type 95 Sqmm
Outdoor type 95 Sqmm
Straight Through 95 Sqmm
Supply, jointing and testing in replacement LT Striaght Through joint cold applied insulation and sealing system compound joint suitable for 3.5/4.0 core, XLPE cable of following type & size :-
(a) Straight Through 120/240 sqmm 3.5 core
(b) Straight Through 70 to 95 sqmm 3.5 core
(c) Straight Through 25 to 50 sqmm 3.5 core
S & F, in replacement, by removing melted or brunt terminals/ connections of MCCB, 4 pole, 415 Volts, with in existing electric panel and connecting with new Adjustable type connections of following capacities:-
(a) 200 Amps, 36 kA,
(b) 160 Amps, 25 kA
(c) 100 Amps, 16 kA
(d) 63 Amps, 16 kA
(e) 32 Amps, 16 kA
Supply & Fix in replacment LED Street light-Prism- high lumen output with cast aluminium housing, toughend glass, IP66, and wired with all accessories and lighting luminaires with minium 70 Watt on existing poles with existing angle MS bracket, by removing old street light fitting complete all as specified and as directed Make: CG Model : LSTP-72-CDL or Bajaj, Model: BRTFG 72W LED I or Polycab Model:-PCGLS T1 72
S&F in replacement Street light timer analog clock type with battery backup suitable for connection with three phase supply and connected to existing contact for controling complete all as specified and as directed. Make: L&T/ Havells/ Indoasian
Supply and laying or fixing or passing through pipe, in replacement 1100 volts grade heavy duty cable with PVC insulated solid aluminium service wire/ conductor served with PVC and overall PVC sheathed 3 core 4 sq. mm nominal cross section complete all as specified and as directed.
S&F in replacement FRP based outdoor type Junction box pole Hinged (L) mounted with clamps and including MCB SP06 Amps complete all as specified and as directed. Make: Sintex Model No: GS JB 2817 or equivalent as approved by GE.
M&L for preparation of old surfaces of steel tubular poles of any length and applying one coat of aluminium paint making strip white and blue colour up to 1.5 mtr height from top of PCC foundation block and numbering of poles with synthetic enamel paint black in 80 mm high letters complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surface of PCC poles and applying two coats of synthetic enamel paint with black & white or yellow colour strips 30cm each up to 1.5 mtr height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80 mm high letters 150 mm above the top strip complete all as specified and directed by Engr in charge.
M&L for Replacement of Air break switch (GOD) Triple pole, mechanically gang operated Air Brack Switch, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps, 11000 Volts grade complete all as specified and directed.
Supply and fix in replacement LED street light fitting driver of exisiting make and model of rating 60 W to 72 Watt complete all as specified and as directed. Make: Bajaj/CG/C&S
M&L for painting of GI pipe bracket and clamp any size on pole security lights applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete as per site direction complete all as specified and as directed.
M & L for Repair/ overhauling of complete 75 KVA Capacity oil cooled servo voltage steblizer by dismantling carefully unit and lifting out the core assembly / header , 430Volts and inspection of auto transformer barrier, synchonomous motor, electric circuit board and replacing the defective parts such as push button switch, auto manual switch,DPDT switch, micro switch, potentiometer, electronic circuit card (P.C.B.), PCB & holder, servo motor, carbon brush for balanced type stabilizer relay, MCB indicator, voltmeter, IC, transistor, diode complete including rewiding of bounce with exiting guage appropriate copper wire, insulation material varnishing heating complete, fixing of gate valve at drain plug and complete replacement of transformer oil having die electric strenght not less than 45 KV(at 2.5 m gap) high voltage as per IS specificatio of low viscosity as requried qty including disconnecting cable connection and testing, commissionig all as directed by Engineer-in-Charge. Note:- (The quoated rates also inclusive satisfactory test report of all parameters and transportation charges from ICGS Jakhau jetty to workshop and back to its original location) .
All as above item No 42 but capacity of servo 100 KVA from CGRA Naliya to workshop and back to its original location)
Deduct credit for dismantled materials as per schedule of credit Rs 61,890/-
AARTI ENTERPRISES
NEELKANTHA ASSOCIATE
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .