Head Office, Vijayawada
Rayapudi , Amaravati
Shifting and erection of 11kV and 33 kV Overhead Power lines in E13 Road extension from Ch:0+000 to Ch:1+000 in Amaravati Capital City, Andhra Pradesh including dismantling of existing lines and poles obstructing road development work
1003707
11/CE/ADCL/Engg/2026-27/01 Dt.12.10.2026
OPEN - NCB
Electrical Works
GUNTUR, ANDHRA PRADESH
18 documents required · 14 mandatory · 4 optional
₹5,123
₹1.4 L
15 Oct 2026
15 Oct 2026
15 Oct 2026
Supply, transportation and erection of 12.5 m Spun Pole with working load of 350 kg conforming to IS 1678-1998 and REC specification with latest amendments thereof, in position, aligning and setting to work as per specification, back filling the earth, ramming for consolidation, including cost, conveyance, T&P and labour charges for loading, unloading etc., complete, but excluding pit excavation. [Makes: As per approved makes of APCPDCL]
Excavation of pits in all soils, i.e, mixture of gravel and soft disintegrated rock like shales ordinary gravel, stony earth and earth mixed with fair sized boulders for 12.5 m Spun Poles (2'6"x2'6"x7' or 0.75 m x 0.75 m x 2.1 m) including T&P and labour charges etc., complete.
Supply, and erection of 9.1 M PSCC pole (280 kg) conforming to IS 1678-1998 and REC specification with latest amendments thereof, in position, aligning and setting to work as per specification, back filling the earth, ramming for consolidation, including cost, conveyance, T&P and labour charges for loading, unloading etc., complete. [Makes: As per approved makes of APCPDCL]
Excavation of pits for 9.1 M PSCC Poles 2'x2'x5' or (0.6 m X 0.6 m X 1.5 m) in all soils, i.e, mixture of gravel and soft disintegrated rock like shales ordinary gravel, stony earth and earth mixed with fair sized boulders.
Supply, paving, stringing & jumpering, testing and commissioning of 55 Sq.mm AAA Conductor conforming to REC specification and IS-398 Part-IV 1994 with latest amendments thereof, including fixing of suitable rollers, bamboos, paving out conductor on suitable supports, providing temporary stays, tensioning, sagging correctly, fixing at strain point, transporting to pin points, binding, rectification of poles, guys and jumpering of various Conductors including cost of conductor, transporting of materials and T&P from road side to location including loading and unloading and providing watch and ward till the lines are handed over to APCPDCL etc., complete for finished item of work. (Make: As per APCPDCL approved make).
Supply, paving, stringing & jumpering, testing and commissioning of 100 Sq.mm AAA Conductor conforming to REC specification and IS-398 Part-IV 1994 with latest amendments thereof, including fixing of suitable rollers, bamboos, paving out conductor on suitable supports, providing temporary stays, tensioning, sagging correctly, fixing at strain point, transporting to pin points, binding, rectification of poles, guys and jumpering of various Conductors including cost of conductor, transporting of materials and T&P from road side to location including loading and unloading and providing watch and ward till the lines are handed over to APCPDCL etc., complete for finished item of work. (Make: As per APCPDCL approved make).
Supply and erection of 33KV TAPING CHANNEL X ARMS (100x50 mm ) including all accessories as directed by Engineer-In-Charge
Supply , fabrication and fixing of M.S.STAY CLAMPS FOR 9.1 M PSCC POLE including labour charges etc., complete as per APCPDCL standards.
Supply, fabrication and fixing of 33KV M.S.BACK CLAMPS FOR SPUN POLES including labour charges etc., complete as per APCPDCL standards.
Supply , erection & fixing 33KV PIN INSULATORS (Polymer) with GI pin including all accessories as directed by Engineer-In-Charge
Supply,erection & fixing 33KV 70KN COMPOSITE POLYMER INSULATOR including all accessories as directed by Engineer-In-Charge
Supply , erection and fixing of 33KV TOP CLEAT WITH CLAMPS including all accessories as directed by Engineer-In-Charge
Supply and fixing of 11 KV pin Insulator (IS 731/ 1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc.,
Supply and fixing of 11 kV Polymer Disc insulator (C&T) and Fittings (C&T Type metal parts) including labour charges etc., complete as per APCPDCL standards.
Supply and fixing of 11KV TOP CLEAT WITH CLAMPS FOR 9.1 m POLE including all accessories as directed by Engineer-In-Charge
Supply, erection and fixing of 11KV V 'X' ARM(75X40) WITH CLAMP FOR 9.1 M Pole including all accessories as directed by Engineer-In-Charge
Supply , erection and fixing of 11 kV Tapping Channel Cross arm with 100x50 mm MS Channel for 9.1 m pole including labour charges etc., complete as per APCPDCL standards.
Supply and fixing of MS BOLTS & NUTS 5/8 X 4" including labour charges etc., complete as per APCPDCL standards.
Supply and fixing of MS BOLTS & NUTS 5/8 X 6" including labour charges etc., complete as per APCPDCL standards.
Providing concrete for pole pit for 12.50 M/350 Kg Spun Pole (Pole pit size 0.6 X 0.6 X 2.0M) with C.C.(1:3:6) using 20 mm and 12mm HBG metal as directed by the Engineer-In-Charge.
Providing concrete for pole pit for 9.1 M/280 Kg PSCC Pole (Pole pit size 0.6 X 0.6 X 1.5 M) with C.C.(1:3:6) using 20 mm and 12mm HBG metal as directed by the Engineer-In-Charge.
Supply and fixing of LT 3 phase 5 wire cross arm of length 4' 5" with 50 x 50 x6 mm MS angle ( wt 7.30Kgs) and necessary clamping arrangements, cutting, drilling and welding etc., complete
Supply and fixing of 100x65mm LT porcelain pin insulator as per IS 1447-1997 suitable for working voltage 1100 V including all accessories like Hot dip GI spindle and nuts etc.,
Supply and fixing of 75x90mm LT porcelain shackle insulator as per IS 1443-1979 suitable for working voltage 1100 V including all accessories like Hot dip GI spindle and nuts etc.
Supply and transportation of 3C X 185 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete including Paving out and laying of UG cable duly forming the cable trench including excavation of trench 2’X2’ filling the trench with excavated earth including transporting of cable etc. complete without construction of trench. Make: Torrent / Universal /Unicab/ Havells / KEI/ Finolex/ /Polycab/Gloster/RR Kabel/KEC Asian Cables /Avocab/Gemscab
Supply and fixing of 11KV 200A TT AB SWITCH WITH INSULATORS including labour charges etc., complete as per APCPDCL standards.
Supply, erection and fixing of 11KV 3Ph HG FuseSets with PolymerType Insulators including all accessories as directed by Engineer-In-Charge
Supply and fixing of TT AB Sitting channel & strut with clamp complete with labour charges etc., complete as per APCPDCL standards.
Supply and laying of 25mm x 6mm GI Flat (1.18Kgs/1Mtr) size Earth wire/Strip in horizontal /Vertical run in Ground/surface/Recess including, riveting, soldering, saddles, making connection etc as required
Supply and laying of CI EARTH PIPE 80 mm DIA 2.5 mts LENGTH including all accessories as directed by Engineer-In-Charge
Supply and making end termination with heavy Alluminium lugs (pin/ ring type) as per IS specification duly crimped with crimping tool, PVC tape etc of 120 sqmm Makes:Dowels/Jainson/Comet
Supply and laying of MS FLAT 75X8 including all accessories as directed by Engineer-In-Charge
Supply and laying of MS Channel 100X50 including all accessories as directed by Engineer-In-Charge
Supply and laying of MS ANGLE 65X65X6 including all accessories as directed by Engineer-In-Charge
Supply and laying of MS Channel 150X75 including all accessories as directed by Engineer-In-Charge
Supply and fixing of LT 3PH SIDE ARMS WITH STUTT as directed by Engineer-In-Charge
Supply and erecttion of DP sets of HT Services as directed by Engineer-In-Charge
Supply and making of 11KV CABLE JOINTING KITS 3X185 SQ.MM as directed by Engineer-In-Charge
Supply of 3PH 100 KVA CSP (AL) DTR BIS EEL-5 (5-star) including all accessories as directed by Engineer-In-Charge
Supply of 3PH 63 KVA AL. Wound DTR (5-star) including all accessories as directed by Engineer-In-Charge
Supply, laying and termination of LT XLPE CABLE SINGLE CORE 150 SQMM XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part - I)./1554-I
Construction of DTR plinths- Pillar mounted RCC plinth with 5'x5'x5" slab with column 6' above ground level. - Excavation of pit of size 4’x4’x5’, laying bed concrete with CC(1:4:8) using 40mm and 20mm HBG metal for 6” depth, Construction of distribution transformer plinth with footing size (4’x4’x1.5’), column size 9”x9”x4'6”(below ground), 9"x9"x5' (above ground), cross beams in plus shape 4'x9”x12”, slab size 5’x5’x5”, providing reif steel 12mm rod for footings and slab at 6" spacing, 4 nos 12mm rod for columns and beams with 8mm stirrups, re-filling the hollow portion with excavated earth, plastering CM (1:5) 12mm thick and painting one coat to slabs, column and beam.
Erection of 3Ph DTRs 63 KVA or 100 KVA Distribution Transformer on the plinth/pole carefully without causing and damaging to bushing including labour and transport complete including earthing as per department standards.
Supply and fixing of HT/LT box type crosss arms as directed by Engineer-In-Charge
Supply and fixing of LT distribution box (SMC) as directed by Engineer-In-Charge
Supply, and erection of M+12 type GI heavy structure tower as per ASCI specifications with minimum weight of WT 4 MT and founadtion Pit dimensions of 1.2X1.2X3.3 Mts. i.e. 4.752CUM as per drawing including earthwork excavaion and foundation of Tower as directed by Engineer-In-Charge.
Supply and erection of M+9 GI Towers (as per ASCI specifications WT 3.4 MT and Pit 1.2X1.2X3.3 Mts. i.e. 4.752CUM as per drawing including earthwork excavaion and foundation of Tower as directed by Engineer-In-Charge.
Dismantlling of 33kV line in E13 road extension as directed by Engineer-In-Charge
Supply and Transportation of 3C X 400 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 33 KV Earthed with Stranded Compacted Circular Aluminum Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete including Paving out and laying of UG cable duly forming the cable trench including excavation of trench 2’X2’ filling the trench with excavated earth including transporting of cable etc. complete without construction of trench. Make: Torrent / Universal / Unicab / Havells / KEI/Finolex /Polycab/Gloster/RR Kabel/KEC Asian cables /Avocab/Gemscab
Supply and making 33KV XLPE 3CX400 SQMM cable heat shrinkable end termination kit. cost includes all costs of labour, testing, transportation of all materials work spot, loading and unloading complete as per APCPDCL standards.
Supply and making 11KV XLPE 3CX185 SQMM cable heat shrinkable end termination kit. cost includes all costs of labour, testing, transportation of all materials work spot, loading and unloading complete as per APCPDCL standards.
Supply and laying of 160mm dia GI Pipe (Class-B) etc., complete as directed by Engineer-In-Charge
Estimate Contract Value (ECV)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NIT-578.doc
TENDER_DOCUMENT • 0.09 MB
PART-II.doc
TENDER_DOCUMENT • 0.03 MB
Tender BoQ 578.xls
TENDER_DOCUMENT • 0.32 MB
Tender Schedule-578.doc
TENDER_DOCUMENT • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .