OFFICE OF SE 7TH CIRCLE PWD GOPESHWAR
OFFICE OF SE 7TH CIRCLE PWD GOPESHWAR
CONSTRUCTION OF PILGRIM ACCOMODATION Q3L AT KEDARNATH
2022_pwd_51945_1
5837/173 Yatayat dated 18.11.2022
Open Tender
Civil Works
Item Rate
270 days
KEDARNATH
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
CD PWD GUPTKASHI
₹12.6 L
OFFICE OF SE 7TH CIRCLE PWD GOPESHWAR
13 Sept 2023
21 Nov 2022
1 Dec 2022
21 Nov 2022
1 Dec 2022
26 Nov 2022
25 Nov 2022
Amount
Note:- Rate should be filled with GST.
CIVIL WORK (ITEM NO 3 TO 85)
Earthwork
Earth Work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of Soil.
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Ordinary Rock
Extra for every additional Lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary rock
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) PCC: M20
RENFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement: All work up to plinth level
1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). RCC M25
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). RCC M25
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more
CENTRING AND SHUTTRING
Centring and Shuttering for Foundations, footings, bases of columns, etc. for mass concrete
Centring and shuttering for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centring and shuttering for Columns, Pillars, Piers, Abutments, Posts and Struts
Centring and Shuttering for Suspended floors, roofs, landings, balconies and access platform
MASONRY & PLASTER WORK
Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing up to floor five level Precast Cement Concrete Solid Block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red Sand Stone - Exposed face fine dressed with rough backing ( 50 mm ) * Locally Available Regional HImalyan Stone is proposed instead of Red Sand Stone
Wall : 450mm X 200mm X 50mm
Providing and fixing cramps of required size & shape in RCC/ CC / Brick masonry backing with cement mortar 1:2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately).
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete.
Wedge expansion type Fastener with threaded dia 10 mm
12 mm Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement
FLOORING
Providing and laying Vitrified Floor Tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified Floor Tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete ( 300 x 600 )
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
DOOR & WINDOW WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:- Butt hinges and necessary screws shallbe paid separately) Second class teak wood ( 35 mm thick shutters )
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains orcross bands and face veneers on both faces of shutters: 459 SUB HEAD : 9 - WOOD & PVC WORK 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :
Float glass panes
5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive,including cleaning etc. complete.
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 300 mm with epoxy resin based adhesive,including cleaning etc. complete.
DOOR FITTINGS ( ALUMINIUM )
Providing and fixing bright finished brass handles with screws etc. complete: ( 125 mm )
Same as above but 75 mm
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :( 200 x 10 mm)
Same as above but (150 x 10 mm)
Same as above but (100 x 10 mm)
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 100 x 85 x 5.5 mm (heavy type)
Same as above but 75x63x4 mm
Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete : 200 mm weighing not less than 240 gms
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
M.S. & STEEL WORK
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, kilogram gates and similar works.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished seamless type tubes
WOOD WORK
P/ F Teak wood hand rail having size of 90 mm x 75 mm size with approved decorative shape etc..
25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with :
P/F Deodar Wood Jhalar (Manually Hand Carved) in 25 mm thick 300 mm wide deodar wood plank including engraving on wood
Providing, laying and fixing of Deodar Wood as in built runner having size of 100 mm X 100 mm thru out over masonary course during construction of wall as per detail drawing. It allows to apply adhesive on top and bottom of wood surface with additional fixing accessories of GI nut & bolt/ anchor fastners, nails, screws etc.. to masonary work or provided RCC runner to protect against demormation with all due respect to complete the job. manufacturer specification.
"Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). { We proposed Teak Wood (as per DAR 9.1.1.) instead of Sal WOod }
Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) :
FINISHING & PAINTING WORK
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
French spirit polishing : Two or more coats on new works including a coat of wood filler
Providing and laying Water Proofing Treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed bywater curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paidfor separately. For the purpose of measurement the entire treated surface will be measured.
Supply, transportation, installation, fitting & fixing and supervision of Laminated Asphalt Shingles having multilayer Panel produce three dimensional profile and shadow lines with fiber glass mat, Waterproof, durable coating, temper proof, 110mph wind resistance, UL Class-A, fire resistance rating, exposure 5.5/ 8 inch, weight up to 450 Pound/ 100 Sqft. Or more, high end products last 30 years & more as per instructions laid on ASTM D3462, ASTM D3018, ASTM D7158-Class-H. The Laminated Asphalt Shingles as per specifications must be laid in proper way over 20mm Cement Fiber Board Make - Everest or Eq. and moisture barrier membrane and Algae resistant Ridge with all required fixtures & fastenings as a complete job as per instructions and satisfaction of Engineer-in-charge with contractors’ own material, labour, tools, lead, lift, T&P, etc. The design and methodology to be approved by Eingeer-in-charge prior commencement of the work. The rate included cost of materials, transportation to site, installation, fixing, pegging, pre-installation preparation works, supervision, petty works involved, taxes, GST, etc. as a compete job. Note: (i) Overlapping has to be provided between two laminated Asphalt Shingles sheets as per the norms. The overlap quantity will not be considered for the measurement/ payment
Providing Algae resistant ridgeor hips of width 30 cm overall width with complete fitting for stylish higher profile and more consistent look for shingles
PLUMBING ITEM (ITEM NO 87 TO 141)
Sanitary fixutures and fittings
Providing and fixing wash down wall mounting EWC-P of approved shade, conforming to Pattern 2 of IS: 2556 (Part -II), with SWR Self it Soil PVC pipe and plug bend as per specifications; glazed vitreous / Coloured European Water Closet with metropole flush valve, with grouting the CI chair in side the floor/wall, rubber gaskets, connecting PVC 110mm dia soil pipe with PVC coupling, nuts, mounting cistern on WC.,1 No.CPVC connection with brass union nuts CP coated and solid verity heavy duty plastic seat cover as per IS-2548, of approved make; including painting of fittings and brackets, cutting and making good the walls wherever require: etc. complete. The rates including cost and conveyence of all materials, labour, machinery etc. EWC-P with Soft close Seat cover : Jaquar, Model No: CNS-WHT-959S Metropole flush valve Dual flow : Jaquar, Model No: FLV-1085NG
Providing and fixing White glazed vitreous Wash Basin Oval Under-Counter, size 550 x 425 x 195 mm dia., with supporting M.S. or C.I. Brackets, necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, Waste coupling 32 mm size full thread with 80 mm height Chrome plated, Bottle trap Chrome plated Basin Mixer necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. OVAL UNDER COUNTER BASIN: Jaquar Continental, Model No: FLS-WHT-5701 WASTE COUPLING : Jaquar , Model No: ALD-CHR-705 BOTTLE TRAP : Jaquar , Model No: ALD-769L300X190 Basin Mixer: Jaquar , Model No: FLR-5001B
Providing and fixing 15mm C.P. brass angle valve with C.P. copper connecting pipe 450 mm long and nuts, washer and brass flange complete, including cutting and making good the wall where required. ANGLE VALVE : Jaquar, Model No. FLR-5053N BRAIDED HOSE Copper Pipe : Jaquar, Model no. ALD-805B
Providing and fixing in position 15 mm C.P. brass bib cocks of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. BIB COCK : Jaquar Fusion , Model No. FUS-29037
Providing and fixing in position 15 mm C.P. 2 Way bib cock with angle Valve of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. 2 Way BIB COCK : Jaquar Fusion , Model No: FLR-5041N.
Providing and fixing of Hand Shower (Health Faucet), with 8mm Dia,1Rmt Long pvc Tube and Wall Hook accessories of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. HAND SHOWER : Jaquar , Model No: ALD-573
Providing and fixing CP BrassSingle Leaver thermostatic diverter of quality & make as approved by Engineer in charge. Single Lever thermostatic mixer :Jaquar Aquamax, Model No: ALD-661
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter OVERHEAD SHOWER: Jaquar Continental, MODEL NO. OHS-1789
Providing and fixing of electrical Storage type water Geyser inclusing all required accessories cutting, chassing and good the same. 25 Litre Storage, Make: Jaquar Elena
Internal drainage and rain water
Providing, Fixing, testing & commissioning of 50 mm Outer dia double socket soil & waste Pipe in position minerally reinforced polypropylene high density low noise pipe ring fit conforming to BS EN 1451, Fire resistancy DIN 4102, B2, Tensile strength: 13 N/mm2, waste water between pH 2 and pH 12, Density: 1.9 g/cm3 3 DIN 53479 including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs etc. including cutting holes in walls, slab and beam and making good the same.. The scope shall also include for chasing the wall by grinder cutter and making good the same. Rate shall also include Providing and laying 100mm thickness cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) around the pipe. The rate shall be including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical specification etc. complete the job.
Providing, Fixing, testing & commissioning of 75 mm Outer dia double socket soil & waste Pipe in position minerally reinforced polypropylene high density low noise pipe ring fit conforming to BS EN 1451, Fire resistancy DIN 4102, B2, Tensile strength: 13 N/mm2, waste water between pH 2 and pH 12, Density: 1.9 g/cm3 3 DIN 53479 including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs etc. including cutting holes in walls, slab and beam and making good the same.. The scope shall also include for chasing the wall by grinder cutter and making good the same. Rate shall also include Providing and laying 100mm thickness cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) around the pipe. The rate shall be including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical specification etc. complete the job.
Providing, Fixing, testing & commissioning of 110 mm Outer dia double socket soil & waste Pipe in position minerally reinforced polypropylene high density low noise pipe ring fit conforming to BS EN 1451, Fire resistancy DIN 4102, B2, Tensile strength: 13 N/mm2, waste water between pH 2 and pH 12, Density: 1.9 g/cm3 3 DIN 53479 including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs etc. including cutting holes in walls, slab and beam and making good the same.. The scope shall also include for chasing the wall by grinder cutter and making good the same. Rate shall also include Providing and laying 100mm thickness cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) around the pipe. The rate shall be including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical specification etc. complete the job.
Providing & fixing poly propylene P Trap of 110mm dia diameter With Height riser/necessary distance piece for wash basin/sink/Urinal drain connection with and 150x150mm heavy duty openable grating, making necessary SLAB /WALL/Beam holes and cutting walls, etc complete.
Providing and fixing 100 mm sand cast Iron grating for P trap.
Internal water supply work
Providing and fixing of 20 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 25 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 32 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 40 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 50 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 63 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 20 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 25 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 32 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 40 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 20 dia pipe.
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 25 dia pipe.
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 32 dia pipe.
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 40 dia pipe.
Supply, installation, laying of Insulation of '50' mm thick PUF Section having density of 36 to 40 Kg/M3 covered with UV Paint Work for 20MM diameter Pipe and inbsulation shall be covered with 3MM HDPE/Approved Equivalent protective coating over the pipe with all accessories and clamp, support. The pipe shall be applied with VOC free water based adhesive only. Insulation shall be for all pipes complete with required elbows (short and long), Tees, Reducers, flanges, fittings as required.
Supply, installation, laying of Insulation of '50' mm thick PUF Section having density of 36 to 40 Kg/M3 covered with UV Paint Work for 25MM diameter Pipe and inbsulation shall be covered with 3MM HDPE/Approved Equivalent protective coating over the pipe with all accessories and clamp, support. The pipe shall be applied with VOC free water based adhesive only. Insulation shall be for all pipes complete with required elbows (short and long), Tees, Reducers, flanges, fittings as required.
Supply, installation, laying of Insulation of '50' mm thick PUF Section having density of 36 to 40 Kg/M3 covered with UV Paint Work for 32MM diameter Pipe and inbsulation shall be covered with 3MM HDPE/Approved Equivalent protective coating over the pipe with all accessories and clamp, support. The pipe shall be applied with VOC free water based adhesive only. Insulation shall be for all pipes complete with required elbows (short and long), Tees, Reducers, flanges, fittings as required.
Supply, installation, laying of Insulation of '50' mm thick PUF Section having density of 36 to 40 Kg/M3 covered with UV Paint Work for 40MM diameter Pipe and inbsulation shall be covered with 3MM HDPE/Approved Equivalent protective coating over the pipe with all accessories and clamp, support. The pipe shall be applied with VOC free water based adhesive only. Insulation shall be for all pipes complete with required elbows (short and long), Tees, Reducers, flanges, fittings as required.
Supply, installation, laying of Insulation of '50' mm thick PUF Section having density of 36 to 40 Kg/M3 covered with UV Paint Work for 50MM diameter Pipe and inbsulation shall be covered with 3MM HDPE/Approved Equivalent protective coating over the pipe with all accessories and clamp, support. The pipe shall be applied with VOC free water based adhesive only. Insulation shall be for all pipes complete with required elbows (short and long), Tees, Reducers, flanges, fittings as required.
Supply, installation, laying of Insulation of '50' mm thick PUF Section having density of 36 to 40 Kg/M3 covered with UV Paint Work for 63MM diameter Pipe and inbsulation shall be covered with 3MM HDPE/Approved Equivalent protective coating over the pipe with all accessories and clamp, support. The pipe shall be applied with VOC free water based adhesive only. Insulation shall be for all pipes complete with required elbows (short and long), Tees, Reducers, flanges, fittings as required.
Providing and fixing of 20mm diameter gun metal gate valve with C.I. wheel of approved quality
Providing and fixing of 25mm diameter gun metal gate valve with C.I. wheel of approved quality
Providing and fixing of 32mm diameter gun metal gate valve with C.I. wheel of approved quality
Providing and fixing of 40mm diameter gun metal gate valve with C.I. wheel of approved quality
Providing and fixing of 50mm diameter gun metal gate valve / scour valve with C.I. wheel of approved quality
Providing and fixing mosquito proof stainless steel overflow grating for tanks.( Zoloto/ Audco/ R.B./ Spirex)
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.
Supplying, fitting & fixing of 40mm dia Pressure Reducing Valve set of approved make & best quality having by-pass arrangement consisting of the following:-
Providing and fixing of 25 mm nominal bore ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
Providing and fixing of 40mm diameter gun metal non- return valve (vertical) of approved quality
Providing and fixing of 50mm diameter gun metal non- return valve (vertical) of approved quality
External drainage work
Providing and fixing of 110 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints, including trenching, refilling & testing of joints etc. complete as per direction of Engineer-in-Charge.
Providing and fixing of 160 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints, including trenching, refilling & testing of joints etc. complete as per direction of Engineer-in-Charge.
External water supply work
Providing and fixing of 50 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.
O & M FOR 5 YEARS
Operation and maintanance for 5 year for all parts as per above BOQ (7.5% of cost)
ELECTRICAL ITEMS (ITEM NO. 143 TO 213)
LT PANEL
Supply, Installation testing & commissioning of medium Voltage sheet steel metal clad, compartmented cubicle Panel board. Shifting of panels from site store to the suitable location. Assembling and wiring of component supplied separately. Earthing all components, frame etc. to a common internal earth bar. Connection, testing & commissioning. Electrical contractor shall carry out the insulation test at site & all the readings shall be submitted in duplicate to the consultant or engineer-in-charge. Supply, installation, testing and commissioning all accessories, supporting structure, hard ware etc to complete the job. Supply, installation, testing and commissioning of necessary tools, hard ware, testing hard ware, testing equipment etc. The rates for the distribution boards apart from the Breakers and instruments shall also include the following : This schedule of Quantities shall be read in conjuction with the technical specification, General & Special conditions as well as all tender drawings. Supporting rigid steel framework. Cubicle type, 14 gauge CRCA sheet steel enclosed. Proper bonding to earth. Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram. Providing cable clamps / supports within distribution boards cable alley. TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link. All MCB’s shall be of minimum 10 KA breaking capacity. The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor based above 250 amps capacity, unless specified otherwise. All motor feeders MCCBs shall be of motor duty. Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5. Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993. IP 54 for all Indoor panel. IP 65 and double door for all outdoor panel. All MCCB’s shall be provided with operating mechanism for door interlock. All measuring instruments (Meters) shall be of digital electronic with LED of approved make. All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. All panels shall have provision of the following: Pad locking of Switch board doors. Pad locking of MCCB’s handles in “OFF” Position. All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. SPD as shown in SLD Aprooved Makes-L&T/ABB/schnider/Legrand/SIEMENS
Supply, Installation, testing and commissioning of IP 65 rated METER PANEL - Q3L Having, Incomer: 200 Amp 25 KA FP MCCB (01 No). 1 NO SPD 1 NO MFM INDICATION LAMP- 6 NOS Out Going: 1-PH KWH METER (01No) 40 Amp DP 10KA MCB (01No) 3-PH KWH METER (12Nos) & 40 Amp FP 10KA MCB (12Nos) ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT.
DISTRIBUTION BOARDS
Supply, installation, testing and commissioning following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 12way, Double door (IP43, IK09)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door (IP43, IK09)
Supply, installation, testing and commissioning 'B' series, SP MCB Supply, installation, testing and commissioning 5 amps to 32 amps rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of folloeing poles int the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supply, installation, testing and commissioning following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO) (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 40A. Approved Makes-LEGRAND / SCHNIEDER / SIEMENS / L&T / ABB
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
MV CABLES
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Supply of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Approved Makes- Approved Makes- HAVELLS / POLYCAB / RPG-KEC
3.5C x 150 Sq.mm. Aluminum XLPE armored cable
3.5C x 70 Sq.mm. Aluminum XLPE armored cable
4C x 10 Sq.mm. CU XLPE armored cable
4C x 6 Sq.mm. CU XLPE armored cable
3C x 10 Sq.mm. CU XLPE armored cable
3C x 6 Sq.mm. CU XLPE armored cable
3C x 4 Sq.mm. CU XLPE armored cable
CABLE TERMINATION
Supply and Providing heavy duty double compression brass gland and lugs end terminations,IP 66 complete,SIBG type, for the cable specified under above item with Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland. Approved Makes- DOWELL’S / 3D / HEX JAINSON / COMET / HMI/CCI / 3M
3.5C x 150 Sq.mm. Aluminum XLPE armored cable
3.5C x 70 Sq.mm. Aluminum XLPE armored cable
4C x 10 Sq.mm. CU XLPE armored cable
4C x 6 Sq.mm. CU XLPE armored cable
3C x 10 Sq.mm. CU XLPE armored cable
3C x 6 Sq.mm. CU XLPE armored cable
3C x 4 Sq.mm. CU XLPE armored cable
INTERNAL WORKS
POINT WIRING
Supply, installation, connection, testing & commissioning of following outlet points as per Specification & IS. The unit rate shall be complete with all necessory complete wiring from LDB to respective switchboard & switchboard to Point, including the outlet points with connector, sockets & all necessory items require to complete job. A point shall include in addition to phase & neutral wire, earth continuity wire from LDB to the final termination at outlet points.
Cost includes all the wiring, outlet points shall be done in a surface / concealed manner with ISI approved rigid FR PVC, conduit of minimum 25 mm. dia. using 650 V FRLS copper conductor wire, modular switches with suitable plate, MS back box with brass chromium / cadmium plated machine screws, light point holder, etc.The cost shall also include the cost of the GI back plate, switches, Sockets). Contractor to measure lenght of wiring as per drawing given. No extra cost to be given for wiring.
Wire Size for Lighting circuit
Lighting circuit = 2 x 2.5 mm2 (P+N), 1 x 2.5 mm²(E)(from LDB to Switch board)
From Switch Board to Light Point = 2 x 1.5 mm2 (P+N), 1 x 1.5 mm²(E)
Power circuit (for heater and geyser) =2x4.0 sqmm (P+N) ,1x4 sqmm(E)
Cost of MCB shall not be considered in point rate.
Wherever sensor require, wiring to be done accordingly.
Making of zari in wall using only electric cutter and finishing the surface as it was.
earthing of fitting
electrical connection to the fixture from the out let point/ceiling rose.
Wire breaded PVC flexible conduit from ceiling point to light fixture.
Supply and fixing of supporting frame, hardware and n/c tools and tackles etc For Exhaust fan
Point wiring in PVC conduit, with modular type switch: Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc.as required- Group C
light plug point modular type accessories: Supplying and flxing suitable size GI box with modular plae and cover in front on surface or in recess, including providing and flxing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, onnection, painting etc. as required. (For light plugs to be used in non residential buildings).
power plug point modular type accessories: Supplying and flxing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
S/F brass holder Supplying and flxing brass batten/angle holder including connection etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required upto 450mm sweep.
CONDUIT & OTHER
Supply, installation, testing and commissioning of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
LIGHT FIXTURES
20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures: Supply, Installation, assembling, connection, testing & commissioning of 20W, 2000 Lumen, IP20 4FT Wall/Ceiling mounted LED light fixtures equivalent to Philips make BN021C LED20S PSU CW GR S2 complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications. Approved Makes-Philips/Wipro/K-Lite
18W, 2000 Lumen Surface mounted LED Down light fixtures: Supply, Installation, assembling, connection, testing & commissioning of 18W, 2000 Lumen Surface mounted LED Down light fixtures equivalent to Philips make SM251C LED20S complete with suitable rating lamps and all other necessary accessories to complete the installations as per specifications. Approved Makes-Philips/Wipro/K-Lite
WALL MOUNTED LED LIGHT : Supply, Installation, assembling, connection, testing & commissioning of wall mounted LED Light suitable for 7.5W luminaire along with all other necessary accessories. Equivalent to philips 34034/14/86. IP44. Approved Makes-Philips/Wipro/K-Lite
UP & DOWN LIGHT : Supply, Installation, assembling, connection, testing & commissioning of LED FIXTURE -NWL-17D,20W,LED,3000k, IP 66 Light NWL-17S: wall mount light with up and down illumination, The housing in light weight, made of high strength die cast aluminium and coated by static powder making it weather resistant.Protection screen in tempered glass with high impact resistance . Premium thermal management by high heat conductivity aluminum alloy and thermal fins.Pure Polyester powder coating. Precise structure and multi-protection silicon rubber seal guarantees the fixture IP66 rated. Height – 175mm, Dia.-110mm, Weight - 1Kgs. Power LED Module with high efficacy COB LED, voltage input AC100-277V,50/60Hz. In-Built Electronic Power Supply for LED Module,which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection. Estimated LED Lifetime is 70,000 hours minimum. LM80 report from LED Manufacturer . Light fixture Lumen output is 1668 Lumens. . Sample Should be submitted for concerned engineer incharge for approval of light fixture. Approved Makes-NERI/Iguzzini/Bega/Hess/DW Windsor along with all other necessary accessories.
SITC of exhuast fan (450mm)
EARTHING
S/L SWG GI wire in ground: Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Supply, Installation, Testing and Commissioning of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 25.0 mm with copper coating thickness of 250micron tested as per IEC 62561-2 + Universal clamp (SS), 25mm + Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested OEC 2 25 + The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Under floor earth inspection pit. Cost include to have earth pit cover, testing of all things, etc. in all complete manner.
O & M FOR 5 YEARS
Operation and maintanance for 5 year for all parts as per above BOQ
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .