Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 UDYAM RJ 01 0091182 | AJMER | RAJASTHAN | 305001 | ₹1.5 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.5 Cr+₹3.2 L (2.15%)Rejected-AOC PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | ₹1.5 Cr+₹3.2 L (2.15%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹1.6 Cr+₹15.9 L (10.8%)Rejected-AOC C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | ₹1.6 Cr+₹15.9 L (10.8%) | L3 | Rejected-AOC Rejected |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
15 Feb 2022, 6:00 pmClosed
GE AF NALIYA NO 1
GE Air Force stn Naliya Kutch 370655
WORK SERVICES FOR OTM ACCN FOR PAR AT AF STN NALIYA
2021_MES_485187_2
8793/E8
Open Tender
Civil Works
Lump-sum
365 days
Naliya
As per NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE AF NALIYA NO 1
₹2.2 L
Yes
22 Apr 2022
18 Jan 2022
17 Feb 2022
18 Jan 2022
15 Feb 2022
25 Jan 2022
Amount
NOTE: Schedule ‘A’ Part - I to XVI are under Ser No. 1 to 16 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the tenderer for BUILDINGS /STRUCTURES as listed in Schedule ‘A’ Part-I.
Lumpsum price worked out by the tenderer for EXCAVATION AND EARTHWORK as listed in Schedule ‘A’ Part-II.
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III.
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-IV.
Lumpsum price worked out by the tenderer for ROAD/PATH/CULVERT AND HARDSTANDING as listed in Schedule ‘A’ Part-V.
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI.
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII.
Lumpsum price worked out by the tenderer for CHILLAR FOUNDATION as listed in Schedule ‘A’ Part-VIII.
Lumpsum price worked out by the tenderer for STEEL FENCING GATE as listed in Schedule ‘A’ Part-IX.
Lumpsum price worked out by the tenderer for FIRE FIGHTING SYSTEM as listed in Schedule ‘A’ Part-X.
Lumpsum price worked out by the tenderer for MISC BLDG WORKS as listed in Schedule ‘A’ Part-XI.
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-XII.
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-XIII.
Lumpsum price worked out by the tenderer for AIR CONDITIONING as listed in Schedule ‘A’ Part-XIV.
Lumpsum price worked out by the tenderer for LIGHTENING ARRESTER as listed in Schedule ‘A’ Part-XV.
Lumpsum price worked out by the tenderer for DEMOLITION AND DISMANTLING as listed in Schedule ‘A’ Part-XVI.
SCHEDULE `A' PART-XVII MISCELLANEOUS ITEMS OF WORK (Note for items 17.01 to 24.01: The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
SEWAGE DISPOSAL S&F advance septic tank of capacity 1200L made of LLDPE (linear low density polyethylene). The system consists of 1 no. of LLDPE Tank made of Rota moulding process, having diameter of 1.30 m with usual process variation and height of 1.40 m with usual process variation. The tank shall have two chambers (zones), i.e. setting zone and film zone (High specific surface area) with pall ring media. The first chamber to work as a solid seperation zone where the setteleable solids settle down and are further degraded anaerobically. Second stage is high specific surface area (100 m2/m3) through fixed film plastic media to retain high mass of anaerobic micro-organisms to degrade the organic matter in the sewage complete all as specified and as directed.
S&F Pre-fabricated Soak pit of capacity 4000L made of LLDPE (Linear low Density Polyethylene). The system consists of 1 No of LLDPE tank made by Roto moulding process having diameter of 1.90m & height of 2.02m with usual process variation. Thank to have perforations of suitable size on major part of body for absorption of sewage coming from septic tank in to soil complete all as specified and as directed.
CHILLAR FOUNDATION/TRAVERSE AND TOE WALL / FENCING GATE M&L Preparation of newly plastered surface of wall and applying two coats of acrylic emulsion paint in camouflage pattern over a coat of primer complete all as specified and directed.
FIRE FIGHTING POINT M & L for Pre-cast cement concrete (1:5:8) (20mm graded stjone aggregates) block masonary with soild block, exc 10cm in with and setting in cement motar 1:6 complete all as specified & directed.
EXTERNAL ELECTIFICATION Supply and Installation / commisioning of 11kV 630Amps 21kA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of (DV) One No. Direct Module for incoming cable and One No. Fixed MOTORISED Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure with series trip, self-powered microprocessor based numerical over current and earth fault relay protection. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Al. Unarmored XLPE cable as per comprising the followings: 1.Protection Relay Aux Power Ashida/C&S make with RS485 port (50,50N,51,51N)(1 Set), 2.Protection CT - 40/1 A, 2.5VA, 5P10 (Make - Ericon/ECS/Pragati/Eq) (1 Set), 3.Manometer (1 No),4.Voltage Presence Indications for each Module (2 Set), 5.Mechanical ON/OFF/TRIP Indications for Breaker on front Mimic(1 Set),6. Operating handle(1 No),7. 24V DC Battery & Charger for Motor Operation of VCB (1 Set), 8. Cable bushing must be replaceable at site., 9. RMU must have provision of Gas filling at site, in case there is some leakage of the gas and Vacuum interrupter must be same make as RMU., 10.Incoming Cable shall be required Touch proof Termination kit, same shall be in purchaser scope.Termination Activity shall be in purchaser scope. Transformer:- 11. 100kVA 11/0.433kV Dyn11, ONAN , Copper wound, Hermetically Sealed Transformer with corrugated tank, TOP Bushings on HV and on LV Side, Temp Rise: 35/40 Deg C. over ambient temp of 50 Deg. C ( Oil/Winding), Off circuit Tappings +5% to -5% @2.5% per step, Losses (As per IS1180 level 2/star 1),Impedance - 4% (subjected to IS tolerance). (Makes: Nucon/ABB's Approved vendors) (1 No),12. Oil Temperature Indicator with alarm and trip contact(1 no), 13. Winding Temperature Indicator with alarm and trip contact(1 No),LVS PANEL - 14. 320AMPS ALUMINUM BUSBAR (100% For Phase and 50% for Neutral, Current Density - 0.8amp/Sqmm ),15. Offered LT Panel shall be with 320A Aluminum Busbar, Construction with CRCA 1.5/2mm thickness sheet, Form 2B, Ingress Protection ≥ IP4X, consisting of following,16. 320Amps 433V 36KA 4P Fixed Manual Molded Case Circuit Breaker (MCCB T5) with microprocessor-based overcurrent, short circuit and earth fault protection (Make:ABB/Equivalent),17. Outdoor type enclosure having construction of Galvanized Sheet Steel of thickness 2mm for Load Bearing Member and 1.5mm for Non-Load Bearing members with HRCA base frame. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP34 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Paint (Colour Light Gray & D.A. Gray). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. And switch operated Lamp in Transformer compartment with bulket arrangement. 18.Interconnection Between HT switchgear RMU and Transformer HT bushing inside CSS enclosure using 1Cx3Rx95Sq.mm XLPE Single core Aluminum cable (1 Set).19. Interconnection between Transformer & LT switchgear using Aluminum Busbars.(1 set) 20. Internal earthing connections by using 50 x 6mm GI strips including Transformer neutral.(1 Set)
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as directed by EIC.
Supply and installation and commisioning of capacity of 100 KVA Isolation transformer, indoor / Outdoor type complete copper wound, oil cooled, class of insulation B, metallic body duly powder coated designed for I/C voltage 415+-5% and O/P voltage range 415+-5% with standard fittings, 3 Phase 4 wire with Primary & secondary winding ratio 1:1 , vector group:Dyn 11, Delta-Star, IP 42/55 with first filling of transformer oil of requisite dielectric strength up to level, efficiency more than 95%, separator neutral bushing shall be brought out for earthing. Potential difference between N to E less than one Volt with all standard fittings like digital tem meter, adequate number of cooling radiators, lifting hook one set, earthing terminal two nos complete with over load/short circuit protection all as specified and directed by EIC.
Supply & Fix in replacement of Automatic / Manual with inbuilt Time delay Transfer Switch 200 Amps four pole (with Enclosure) with connections of Auto / Manual Transfer Switch including Testing all as directed.
Supply & fix LED flood light-High Lumen output fitting of 100 Watt with exclusive innivative designed, long life versatile pressure die cast aluminium IP65 flood light luminaire with high power LED as light source complete all as specified and directed by Engineer-in-Charge.
M & L of Chemical earthing complete with copper plate electrode 900 x 600 x 5 mm thick burried directly in ground earth pit not less than 3.00 mtr below ground level with top edge of earth plate at a depth not less than 2.25 mtr below normal ground level connected to and including Copper strip of 32x6 mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers or brazing etc. of galvanized iron or steel including provn of GI protection pipe light grade of 40 mm bore and connected to earth strip earthing test point all as shown in electrical plate No 5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4 kg/sqm) with frame, funnel with watering pipe of 15 mm bore medium grade, wire mesh and lugs, test point including salt (150 KG), coal dust (100 KG) & Magnesium sulphate (150 KG) including refilling of earth pit with cultivated soil and removal of surplus soil upto 50 mtrs apart etc. complete. Note : Copper strip exceeding 7.5m long shall be measured & paid separately. The earth resistance value less than 1 ohm. Failing to achieve the value the contractor shall be re do the earthing without any extra cost.
AIR CONDITIONING Supply and install Electronic wall mounting type voltage stablizer suitable for AC upto 1.5 TR for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ±2.5% and of capacity 4.0 KVA complete all specified and directed.
Supply and install Electronic wall mounting type stablizer suitable for AC upto 2.0 TR Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ±2.5% and of capacity 5.0 KVA complete all specified and directed.
FIRE ALARM SYSTEM Supply, install and commissioning analogue addressable type Fire alarm control panel along with network interface card and with Lead acid battery back up for 08 hours normal operation and 15 minutes alarm operation. (The control panel, battery charger, etc shall be UL listed) Complying with BS EN 54 Two loop panel with 99 detectors & 99 modules & upto 200 detectors and modules (per each loop) complete all specified and directed.
Detectors Complying with and type certified to EN - 45 analogue Addressable type multi sensor heat and smoke detector combination type Photoelectric /Optical with base with self built intelligence as per IS: 11360 (To be provided below and above false ceiling) complete all specified and directed.
Supply and Fix response indicator for all detectors located above false ceiling complete all specified and directed.
Supply anf fix analogue addressable fault / short circuit isolator module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected complete all specified and directed.
Supply and fix analogue addressable control module shall be capable of providing DPDT contact rated at 24 C, DC, 2A complete all specified and directed.
Supply and fix horn/ storbe rated at 82 dBA @ 3 M for audible annunciation and 75 cd flashing at 1 Hz for visual indication complete all specified and directed.
Supply and fix addressable single action manual call station having an integrally mounted addressable module that monitors and reports contact status complete all specified and directed.
Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles complete all specified and directed.
S & F Fire bucket (4 Nos) & fire extinguishers ABC type of capacity 9Kg (4 Nos) complete all specified and directed.
LIGHTNING ARRESTOR Supply & fix GI pipe 1.5 RM long medium grade vertically fixed by means of PCC 1:2:4 of size 1 Cubic Feet for mounting of Copper air termination rod complete all specified and directed.
S & F ESE lightning arrester LAP-CX-040 Modle for PAR Radar having 5 RM hieght complete all specified and directed.
EXTERNAL WATER SUPPLY M & L for cutting of existing 150 mm DI pipeline and inserting Tee 150x150x80 mm and connecting 50 GI pipe with reducer complete all specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .