Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹1.4 CrAccepted-AOC | ₹1.4 Cr | 1st | Accepted-AOC L1 |
Tender Value
Refer Docs
EMD Value
₹3.6 L
Closing Date
31 Oct 2022, 5:00 pmClosed
Executive Engineer, UJS, Nainital
The Executive Engineer, Uttarakhand Jal Sansthan Nagar Palika Building, 2nd Floor, Mallital, Nainital, Uttarakhand
Strengthening of Khanshu Water Supply Scheme in Okhalkanda, Nainital
2022_UKJS_50931_15
2045/E-Tender/24 Date 15-10-2022
Open Tender
Civil Works
Item Rate
90 days
Nainital
As Per NIT
3 documents required · 3 mandatory
₹5,900
Executive Engineer, UJS, Nainital
₹3.6 L
29 Aug 2023
24 Oct 2022
1 Nov 2022
24 Oct 2022
31 Oct 2022
24 Oct 2022
Amount
Construction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepeared sub base with 43 grade cement or any other type PCC Grade M-30, coarse and fine aggregates conforming to IS: 383,maximum size ofcoarse aggregate notexceeding 25 mm,mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications. (20% of the total road)
Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc complete.G.I. PIPE CONFORMING TO IS : 1239(PART-1) Medium Duty (Class 'B')
15 mm dia GI Pipe
25 mm dia GI Pipe
40 mm dia GI Pipe
65 mm dia GI Pipe
80 mm dia GI Pipe
100 mm dia GI Pipe
Provision of Semi circular drain considering @ 6.5M length for each Household
Excavation in ordinary soil (loam, clay, sand) for foundation including lift up to 1.5M and lead up to 30M filling waterring and ramming of Excavated the earth in to the trenches or into the sides between foundation trenches or in to the plinth (25% of Total Quantity)
Supply of all materials, labour, T&P etc and construction of R.C.C. CWR of following capacities (in kiloliters) with M.S. ladder outside the tank and alluminium ladder inside of the tank, M.S. M.H. cover with locking arrangement, lightning conductor as per electricity rules, water level indicator,supply and fixiing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover, ventilator column etc. complete with approved water proofing (apex) / enamal paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials, assuming bearing capacity as 8MT/M2. 35 KL
Construction of Circular Pillers for Rising Main
Supplying and Fixing of Fire Hydrant Valve IS 5290 (Flanged) Including carting the same upto site of work and fixing the same and water supply line Including the cost of valves,specials,labour and T&P Complete in all respect.
Providing breaking pressure tank (BPT) to minimise the pressure in the rising main 80 mm
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and making New house service connections from water supply distribution GI pipe line upto water meter chamber inside the property using GI pipe including supply and fixing of electrofussion saddle ,brass ferrules elbow, ball valve etc complete with earthwork, road cutting with restoration works
Excavation in soil mixed with single bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches. (75% of the total)
Excavation in ordinary soil (loam, clay, sand) for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches. (25% of the total road)
Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately (20% of the total Road)
Excavation in Pipe Line Trenches (Over All Quantity i.e. Ordinary Soil and soil mixed with single boulders)
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. For in line pressure Transmeter in distribution network.
Construction of Spring Collecting Chamber with Wing walls
Dismantling of flexible pavements and disposal ofdismantled materialsupto alead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202 (10% of Total Road)
Protection Work (construction of pillar and retaining wall)
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. For in line pressure Transmeter in distribution network.
Excavation in soil mixed with shingle bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling,waterring and ramming of Excavated earth in the trenches. (75% of Total Quantity)
Providing of all materials, Carting from site store of work , Laying and Jointing of G.I Pipes confirming to IS: 1239 (PART-1) including supply of all jointing materials like specials white lead,hemp and oil etc in trenches with its cutting, threading and testing of pipe line etc complete. 15 mm dia GI Pipe
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .