Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹27.9 Laccepted-aoc | ₹27.9 L | accepted-aoc |
Tender Value
₹30.0 L
EMD Value
₹30,038
Closing Date
18 May 2026, 4:00 pmClosed
EE, Polavaram Irrigation Project Left Main Canal Division No 2, Dawlaiswaram
DOWLAISWARAM
Operation and Maintenance of 3rd Stage Lift Talluru Lift 2B at Rajapudi (V), Jaggampeta (M), Kakinada District at KM 3.900 on Right Main Canal of Talluru Lift of ThotaVenkatachalamPushkara Lift Irrigation Scheme for the year 2026-27.
929451
Tender Notice No. 07/2026-27, Dt: 01.05.2026
OPEN - NCB
Electrical Works
KAKINADA
8 documents required · 8 mandatory
₹1,064
₹30,038
2 Jun 2026
4 May 2026
4 May 2026
Provision for Operation & Maintenance Crew from 1/06/2026 to 31/05/2027 for Pump House & Sub-Station Operators and Helpers: Operators ( ITI -Electrical )
Operators ( ITI -Mechanical )
Helpers ( Fitter/ Fabrication/Electrician )
General: Security staff
Provision for O&M consumables like grease, oils, fuses, LT and HT insulators,TC and CC coils, contactors, Power contactor coils, silica gel, betnonite powder, switches, push buttons, gaskets, lighting equipment, transformer oil, gland rope, cable joints etc., Motor protection Relay 5A,contol voltage:100-260V AC
3-Pole Thermal Bimetallic Overload Relay Relay Range: 7.00 - 10.00 A
18A,415V 3 pole AC coil power contactor
Cleaning Agents
Post top insulators
ON Delay ElectronicTimer 240V AC Time:0.3s to 30h contact :5A
Phase failure relay_240V AC with 2 CO output contacts.
Phase failure relay_415V AC with 1 CO output contacts.
Water level controller 240V AC with 1 CO output contacts with sensor
winding Temperature Relay 240V AC with 1 CO output contacts.
620Watts Air blower
outdoor VCB spring charge motor 420W, 230V AC
Rectifier unit_Input:220v AC & output: 24v DC
petroleum jelly
supply and fixing of 185KW/250 H.P 3Phase 50 Hz A.C Auto Transformer Starter air cooled 415v 6ST/HR 20Secs /ST of standard make
silica gel breather bottle
Supply and fixing of ISI mark (IS:15683) Mono ammonium phosphate powder 90 (MAP) 6 Kg Fire extinguisher, stored pressure type, pressure gauge, gross wt. 9.4 kg, empty wt.3.4 kg, Discharge time minimum 13 sec, controllable discharge mechanism, range min. 4 mts applicable on classes A,B, C & electrically started fire, A rating -4 A, B rating -34 B, can construction: Deep drawn and Co2 mig welding, Valve construction: Forging & Machining, internal coating of can: Epoxy powder coating, External coating of Can:Epoxy polyster powder coating, sheet metal thickness:1.60mm, Helium leak detection tested with 5 years warranty Including transportation, all taxes and all labour charges etc complete. Makes : Cease Fire / Minimax
Supply and fixing of 11 KV pin Insulator (IS 731/1971 ) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc.,
Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I
630A, 3 Pole, 50kA, electrically operated, manually draw out type Supply of 6-32A,10KA SP MCB's
Supply and transportation of 90W LED Street light Luminaire made of pressure diecast aluminum body with powder coated, having protective toughened glass, supply input voltage 120 - 270V AC, P.F > 0.90, high power LEDs having System Efficacy >= 120 lumens/watt and junction temperature < 70°C, with Ingress protection IP66, Luminaire performance complies to IS 10322 (Part 5/Sec-3), driver surge protection 4KV, in-house additional Surge protection 10 KV with optics distribution, THD<10% at 110 Volts AC, driver efficiency >90%, CCT: 3000K - 5700K, minimum CRI>70, etc., complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I
Supply and fixing of 20-24W, not less than 1100mm length LED batten light with extruded aluminum housing and polycarbonate cover, input voltage AC 220 - 260 Volts, with high power LEDs, having System Efficacy of >=100 lumens/watt , PF>0.9, Surge protection: 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, etc., complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I.
PVC /cotton tape Role ( 8 Mtrs)
Supply and Fixing of 240/220 V, LED (22.5 mm dia ) Pilot lamp with integral circuit, terminal block, including connection etc. as required (a)Red/yellow/Green colour
Supply and Fixing of 240/220 V, LED (22.5 mm dia ) Pilot lamp with integral circuit, terminal block, including connection etc. as required (b)Blue colour
Supply of 6-32A,10KA DP MCB's
Supply of 18" (450mm) ISI, 900 RPM Heavy duty exhaust fan with metallic blades with Mark. Makes : As per list of recommended brands.
Supply of 250A to 350A HRC Fuse Links.
Supply of 6A to 35 A HRC Fuse Links.
Supply and fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. (b)Luminous type
Supply and fixing of 12V 42 AH SMF battery with 3 years warranty including wire leads, connections etc complete.
Supply of 48" (1200mm) Sweep 5 star rated BLDC (Brush less Direct Current) Ceiling Fan with double ball bearings, input voltage 230V AC converted to 24 V DC, power input not more than 32W , air delivery 210/220 cubic meter/min with remote and without Regulator. Makes : Atomberg(Gorilla GV2 )/ Halonix(Plasma) /Havells(Efficiencia Neo)/ Crompton(EN Riviera)/Superfan(E281)/RJP(Ecowise)
Supply of new and tested transformer oil as per IS-335 - 1972 (per Ltr)
Supply of 1.5 Sqmm FRLS/ FRLS-H / HFFR PVC insulated 1100V grade as per IS : 694 / 1990 specification for Copper cable.
Supply of 100 A to 160 A HRC Fuse Links.
Supply and fixing of energy analyzer (multi-function energy meter) with LCD/LED display capable of minimum 20 numbers electrical parameters display with 1A/5A CT input for LV/ HV network, RS 485 communication port etc. complete in all respect.
Supply Installation Testing and commissioning of self-healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing as required. Makes: As per list of recommended brands.
Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) Supply and fixing of distribution type lightning arrester 11 KV 5 kA
Service charges for Overhauling and testing of the Electro- Hydro-Mechanical equipment at the Pump House including required lubricants gaskets, gland rope varnish and alignment of shafts, terminal blocks,etc.,as per O&M manuals. Servicing, overhauling of 186.25 KW, 415V, Bharat Bijlee make LT motor including cleaning of stator, rotor by air and by CO2, application of anti tracking varnish for stator and rotor windings,and epoxy gel coat on end winding portion,heating,replacement of minior parts, testing of stator, rotor for IR, PI, winding resistance and replacement of DE, NDE side bearings with new bearings(Supplied by department if necessary), balancing the rotor and Re-assembling the motor including cost of all necessary parts required for the job etc., complete for servicing, overhauling and testing, commissioning of the motor for satisfactory running of the motor etc including labour charges & miscellaneous works for finished item of work.
Repair to Vacuum Motor ,including supply of Miscellaneous spares, transportation charges finished item of work
Testing,sevicing & repairing of 630 Amps Air circuit Breaker including replacement of following items with new one i.e. cradle terminal ,cradle assembly & mould base.
Replacing old and unserviceable gasket of top cover plate of transformer having following capacity. 500 / 1000 KVA.
Replacing old and unserviceable gasket of bushing for the following Transformer capacity.500 / 1000 KVA LT.
Carryout routine maintenance, servicing and testing of 630A to 1000A L.T.ACB by cleaning fixed contacts, moving contacts and arcchutes including servicing and putting the ACB in perfect working condition after detting all relay and ON, OFF mechanism etc done with only manufacturing companies. As per ELEC-6.4.1
Filteration of Transformer oil at site for 2 Transformers i.e 620ltrs/Transformer. As per ELEC-6.4.15
Routine maintenance of transformer, including testing of insulation resistance, oil break down strength. Reconditioning / replacement of silicazel, cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil). As per ELEC-6.4.3
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BOQItemswb.xlsx
TENDER_DOCUMENT • 0.51 MB
NIT.doc
TENDER_DOCUMENT • 0.16 MB
Schedule A.xlsx
TENDER_DOCUMENT • 0.04 MB
7DECLARATION.pdf
TENDER_DOCUMENT • 0.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .