Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹6.0 LAccepted-AOC CHOBATA STREET MANDI DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | l1 | Accepted-AOC Work awarded after Negotiation | |
| 2 | l2₹6.7 L+₹57,221.96 (9.38%)Rejected-Finance MANDI DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | l2 | Rejected-Finance L2 | |
| 3 | l3₹7.0 L+₹88,006.76 (14.4%)Rejected-Finance VILLAGE KUTHANI P O SAINJI TEHSIL SUNDERNAGAR DISTT MANDI H P | MANDI | HIMACHAL PRADESH | 175001 | l3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹14,150
Closing Date
29 Apr 2021, 12:00 pmClosed
Sr. Executive Engineer Electrical Division Sundern
O/o Sr. Executive Engineer Electrical Division SNR
Estimate for Providing SOP to LWSS Pump House Chamukha-Nalni at Chakrot by providing 11 KV HT line , 63 KVA /11/0.4 KV S/Stn a/w 3-Phase LT line at village Chakrot in (E) section Local-II under ESD ,HPSEB,Ltd, Sundernagar. T.S No.-166/2020-21 S/Amt.
2021_HPSEB_45429_2
HPSEBL/183619/DB-23/NIT No.- 01 /2021-22
Open Tender
Supply and Erection
Item Rate
90 days
Sundernagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
Sr. Ececutive Engineer Electrical Division SNR
₹14,150
19 Sept 2022
23 Apr 2021
29 Apr 2021
23 Apr 2021
29 Apr 2021
23 Apr 2021
Amount
Erection Part OF 11 kv HT LINE
Erection of Steel Tubular Pole 9 Mtr. long (Single pole strs.) comprising following. Digging of Pit ( 0.80x1.20x1.50mtr.) Drilling of Holes in Poles,X-arms, fixing of Insulator, X-ams, Knee Braceing set, Top clamps, fixing of Barbed wire, Danger Plate,Erection of pole, filling of Pits , Filling of RCC Mff & ramming, Painting of Poles complete in all respect.
Erection of Steel Tubular Pole 11 Mtr. long (Single pole strs.) comprising following. Digging of Pit ( 0.80x1.20x1.50mtr.) Drilling of Holes in Poles,X-arms, fixing of Insulator, X-ams, Knee Braceing set, Top clamps, fixing of Barbed wire, Danger Plate,Erection of pole, filling of Pits , Filling of RCC Mff & ramming, Painting of Poles complete in all respect.
Errection of Steel Tubular Pole 11 Mtr. long (Double pole strs.) comprising following. Digging of Pit ( 0.80x1.20x1.50mtr.) Drilling of Holes in Poles,X-arms, fixing of Insulator, X-ams, Knee Braceing set, Top clamps, fixing of Barbed wire, Danger Plate,Erection of pole, filling of Pits , Filling of RCC Mff & ramming, Painting of Poles complete in all respect.
Erection of Stay set H.T. Comprising following:- Digging of Pit, Nozzeling & Tighting complete in all respect.
Erection charges of G.O Switch
Erection of HT earthing set comprising following:-Digging of Pit, Fixing of G.I wire to earth system and filling of Pit complete in all respect.
Erection of line conductor such as stringing, tensioning and sagging, jointing and fastening of conductor size 100 SQR MM
Erection of line conductor such as stringing, tensioning and sagging, jointing and fastening of G.I Wire
Add extra mannual carriage from road head to cite of work considering Av. Lead 0.415 km
Supply Part For 11 kv HT line
Providing RCC Pipe(Muff) ISI Marked sutaible for different size of steel poles 2000 mm inlenght and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wire of 12 SWG Rings and 6 mm MS Round in vertical direction conforming to IS 458-1988.
Prov. HT Stay set made of M.S Round 1800 mm in length ,18 mm dia having thread upto 300 mm on one end with one nut and one check nut to avoid slippage and eye of 40mm dia on other side and welded conforming REC Specifications. Elbow made of channel iron 75 x40 x6 mm,250 mm long and M.S. Round 18mm dia , vertical height 450 mm, both end bent after putting into two holes in channel iron taking the ends out 25 mm minimum and welded with channel iron . One anchor of A.I.65X65x6mm ,750 mmin length with one hole of 20 mm dia in the centre . The complete stay set shall be painted with superior quality black Japan paint.
Providing X-Bracing set made of only TATA/SAIL/Rashtriya ispat MS Angle iton 50*5 mm having length 1.5 mtr 2 No. straight member and 2 No. cross members of 2.7 mtrs conforming to REC Specifications sutaible for easily fixing of both PCC/Steel tubular poles as per requirement.
Providing A.I X-Arm for gaurding across the road made of only TATA/SAIL/Rashtriya ispat MS Angle iton 50*5 mm having length 1.8 mtr conforming to REC Specifications sutaible for easily fixing of both PCC/Steel tubular poles as per requirement.
Providing A.I X-Arm for gaurding across the road made of only TATA/SAIL/Rashtriya ispat MS Angle iton 50*5 mm having length 2.7 mtr conforming to REC Specifications sutaible for easily fixing of both PCC/Steel tubular poles as per requirement.
Prov. M.S.C.I 100*50*6 mm cross arm 2800 mm long sutaible for fixing on both ST and PCC poles Double pole structure 11 KV HT line, with holes at sutaible places whereever is required to adjust 5/8" dia nuts and bolts ,pin insulators,bal claves eye socket and washers. The weight of M.S Channel should be strictly 9.56 kg per meter with variation of +/-5%.
Prov. M.S.C.I 75*40*50 mm cross arm 2800 mm long sutaible for fixing on both ST and PCC poles Double pole structure 11 KV HT line to fix GO switch and DO Fuse unit , with holes at sutaible places whereever is required to adjust 5/8" dia nuts and bolts ,pin insulators,bal claves eye socket and washers. The weight of M.S Channel should be strictly 9.56 kg per meter with variation of +/-5%.
Prov. M.S.C.I 100*50*50*6 mm cross arm 1500 mm long sutaible for fixing on both ST and PCC poles Single pole structure 11 KV HT line, with holes at sutaible places whereever is required to adjust 5/8" dia nuts and bolts ,pin insulators,bal claves eye socket and washers. The weight of M.S Channel should be strictly 9.56 kg per meter with variation of +/-5%.
Providing Knee-Bracing set sutaible for 11 KV made of only TATA/SAIL/Rashtriya ispat M.S. Angle Iron (750*50*50mm) conforming to REC Specifications sutaible for fixing both on PCC and ST Poles.
Prov. Fitting for disc insulators including bent stapple , straight strapple, Ba-clvlave eye Socket etc.
Prov. M.S.C.I 100*50*50*6 mm cross arm 2400 mm long sutaible for fixing on both ST and PCC poles Double pole structure 11 KV HT line, with holes at sutaible places whereever is required to adjust 5/8" dia nuts and bolts ,pin insulators,bal claves eye socket and washers. The weight of M.S Channel should be strictly 9.56 kg per meter with variation of +/-5%.
Prov. Top clamp made of M.S Flat 50*5 mm
Earthing set HT made of GI Pipe 40 mm dia (internal dia) wall thickness 3.25 mm medium quality pipe of standard make conforming to IS: Specifications 2500 mm long with GI Socket closed at top pipe shall have holes of 12 mm Dia every 150mm apart throughtout the lenght and staggered diametrically. The bottom end of the pipe shall be tapered cut at 45 degree.
Prov full clamp.
Prov Half clamp.
Prov. Earth Hook for earth wire
Providing Danger plate size 250*200 mm made of Mild steel plates 1.6 (minimum) thick vitreous enameled white letter figure, conventional skill and X-Boxes and single red color on front side for use in HPSEBL. The rear side of the plate shall be black enameled and conforming to ISI Specifications No-IS-1351/1982 Sutaible for 11000 Volts.
Providing Barbed wire
Prov. Aliminium Paint
Prov. Nuts & Bolts with washer off sizes etc. M.S Black Hexagon Bolts and Nuts with washers conforming to ISI-1363-1992 duly fully threaded and Half threaded.
Erection Part Substation
Digging of Pit for pole & 3 No. earthing earthing
Drilling of holes in X-arms
Prepration of plates from STR. Members CI,AI ie X-ARMS & Bracing set
Erection of Double pole
Concreting of RCC Muff
Errection of plateform
Erection of X-ARMS, Drops-Out ,Fuse unit ,Lighting Arrestor, MCCB, Switch LT Box ,Energy Meter .
Erection of Transformer
Providing earthing conn. To Transformer G.O Switch Lightning Arrestor Etc.
Erection of 2 Nos.stay set
Erection of jumpers
Pipe earthing 3 No's. set
Erection of LT Cable
Fixing of Barbed wire & painting of substation structure complete in all respect
Add extra mannual carriage from road head to cite of work considering Av. Lead 0.415 km
Supply Part Substation
Providing RCC Pipe(Muff) ISI Marked sutaible for different size of steel poles 2000 mm inlenght and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wire of 12 SWG Rings and 6 mm MS Round in vertical direction conforming to IS 458-1988.
Prov. M.S.C.I 100*50*6 mm cross arm 2800 mm long sutaible for fixing on both ST and PCC poles Double pole structure for transformer base main channels , with holes at sutaible places whereever is required to adjust 5/8" dia nuts and bolts ,pin insulators,bal claves eye socket
Prov. M.S.C.I 100*50*6 mm cross arm 460 mm long sutaible for fixing on both ST and PCC poles Double pole structure for suppourting main channels of transformer , with holes at sutaible places whereever is required to adjust 5/8" dia nuts and bolts ,pin insulators,bal claves eye socket
Prov. M.S.CI. 75*40*5 MM Cross arm 2800 mm long for suppourting DO Fuse unit and GO Switch
Prov. M.S.A.I 50*50*5 mm length 2800 mm 1 No. for L.A and 2 No. for Distribution pannel box
Prov. M.S.A.I 50*50*5 MM Length 2800 mm *4No. For one structure
Prov. M.S.A.I 35*35*5 MM Length 460 mm *2 No. for one structure
Prov. D.O Fuse unit 11 KV
Prov. Fitting for disc insulators including bent stapple , straight strapple, Ba-clvlave eye Socket etc.
Prov. HT Stay set made of M.S Round 1800 mm in length ,18 mm dia having thread upto 300 mm on one end with one nut and one check nut to avoid slippage and eye of 40mm dia on other side and welded conforming REC Specifications. Elbow made of channel iron 75 x40 x6 mm,250 mm long and M.S. Round 18mm dia , vertical height 450 mm, both end bent after putting into two holes in channel iron taking the ends out 25 mm minimum and welded with channel iron . One anchor of A.I.65X65x6mm ,750 mmin length with one hole of 20 mm dia in the centre . The complete stay set shall be painted with superior quality black Japan paint.
Providing LT Pannel Box 63 KVA WITH MCCB (100 A , 10KA,4P, 1 No.) &SFU(32A, 4 No. Rewireable)
Prov. Earthing set for substation made of G.I Pipe 38 mm dia(internal dia) wall thickness 3.25 mm medium quality pipe of standard make conformimg to IS:Specifications 3000 mm long without GI Socket closed at top pipe shall have holes of 12 mm dia every 150 mm apart throughout the lenght and staggered diametrically.Full clamp of M.S Flat 40*3mm fitted at top end of the pipe along the bolts and nuts six=ze 50*12 mm and washers for fixing the clamp on the pipe. The bottom end of the pipe shall be welded with M,S Plate of size 300*300*6 mm
Prov. Half clamps made of M.S Flat 50*50mm
Providing Danger plate size 250*200 mm made of Mild steel plates 1.6 (minimum) thick vitreous enameled white letter figure, conventional skill and X-Boxes and single red color on front side for use in HPSEBL. The rear side of the plate shall be black enameled and conforming to ISI Specifications No-IS-1351/1982 Sutaible for 11000 Volts.
Prov. Nuts & Bolts with washer off sizes etc. M.S Black Hexagon Bolts and Nuts with washers conforming to ISI-1363-1992 duly fully threaded and Half threaded.
Prov. Aliminium Paint
Erection/Labour Part LT Line
Erection of Steel tubular Pole 9 Mtr. long comprising following:- Digging of Pit, Errection of pole, X-arms,Shackle Insulators, filling of Pits, Erection and filling of RCC Muff & ramming including painting of pole complete in all respect.
Erection of L.T. Stay Set comprising following :- Digging of Pit, fixing of Stay Rod, Nozzeling & Tightening complete in all respect. (Note stay wire will be provided by the HPSEBL separately).
Earthing of LT poles
Add Sagging chages of conductor 7/4.26( 100 sqr mm)
Add sagging charges of G.I Wire 8 SWG
Supply Part LT Line
Providing RCC Pipe(Muff) ISI Marked sutaible for different size of steel poles 2000 mm inlenght and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wire of 12 SWG Rings and 6 mm MS Round in vertical direction conforming to IS 458-1988.
Prov full clamp.
Prov. Nuts & Bolts with washer off sizes etc. M.S Black Hexagon Bolts and Nuts with washers conforming to ISI-1363-1992 duly fully threaded and Half threaded.
Prov. LT Stay set made of M.S Round 1600 mm in length ,16 mm dia having thread upto 300 mm on one end with one nut and one check nut to avoid slippage and eye of 40mm dia on other side and welded conforming REC Specifications. Elbow made of channel iron 75 x40 x6 mm,250 mm long and M.S. Round 60 mm dia , vertical height 300 mm, both end bent after putting into two holes in channel iron taking the ends out 25 mm minimum and welded with channel iron . One anchor of A.I. 50x50x6mm ,750 mmin length with one hole of 20 mm dia in the centre . The complete stay set shall be painted with superior quality black Japan paint.
Prov. D-Iron made TATA/SAIL/Rashtriya Ispat M.S flat of 50x6mm M.S suitable for 3"x3.5" shackle insulators. Having three holes, one in each side suitable for use with 16mm bolt .D-Iron to be painted with superior quality black Japan paint . The size of D-Iron will be 125x75mm. The weight of D-Iron should not be less than 750 grams .
Prov. Aliminium Paint
Prov. Eye Hook Bolt
TILAK RAJ
CONT ANIL KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .