Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹5.0 L
EMD Value
₹12,439
Closing Date
23 Oct 2026, 6:00 pm3d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Assisstant Executive Engineer
Office of the Assisstant Executive Engineer PWD Electrical Subdivision Thalassery
MLA-SDF-Dharmadam LAC - Sir. Pinarayi Vijayan MLA Mouvery Town Beutification Providing Decorative Lights-General Electrical Work
2026_PWD_879035_1
PWD/BLDG/TR/23937/2025_6_1_1/1
Open Tender
Electrical Works
Item Rate
120 days
KANNUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,100
₹12,439
13 Oct 2026
13 Oct 2026
26 Oct 2026
13 Oct 2026
23 Oct 2026
13 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Footpath Lighting | |||||
| 1.001 | OD64783/2026-2027:SITC of LED Decorative Classic luminaire of system wattage 50W, with minimum
dimension
315mm width and 545mm height, BIS certified with a body
and frame of high pressure die cast aluminium, a frosted PMMA protector (IK06)
fixed on tothe optical unit
, separate optical and control gear compartment accessed by opening four
screws at the top of the luminaire, a vent pressure equalization unit and pre-cabled as
required. The luminaire shall have ingress protection of IP66. Highly efficient
temperature
resistant lenses for light distribution with several optical options providing excellent
photometry to optimally cater to different applications. Overall system efficiency of
120lm/W at correlated colour temperature (CCT) 3000K, colour rendering index
(CRI) >70
and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac,
Power
Factor > 0.95, with BIS certified potted driver having internal surge protection of 4
kV and
an additional surge protection device (SPD) of 10 kV | 12 | each | - | - |
| 1.002 | OD64784/2026-2027:Supply installation testing commissioning of Decorative Pole 3.2/3 meter height
above the
ground level made out of GI, tubular pole having two section section, bottom section
of
minimum 900/1000mm with base dia of 114mm and upper section of minimum
2300/2000mm
with minimum dia of 60mm. The pole shaft shall be as per IS 1161. The pole shall
have base plate of
dimension 200x200x12mm/round minimum 200mm including minimum16mm
diameter 4 numbers foundation bolts of
450mm bolt length, 200mm pitch circle diameter manufactured from special steel
along with
nuts, washers, The pole shall be with inbuilt control gear tray at bottom section. The
control
gear tray is prewired with 1.5 Sq.mm cable, 6A SP MCB and 32A stud type 4 way
terminal block for loop-in / loop-out arrangement, 6 A 2 Way terminal connector and
provision
for earthing.The pole shall be suitable for wind loadings as per IS 875 part 3 1987.
Design
comply EN40 standard and basic wind speed 169kmph. Pole should hot dip
galvanized to 65
microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with
two coats
of epoxy primer and above that it should be given marine coating. The complete
system should
be hot dipped Galvanised. (Crompton Deco/K lite COLOMBIA/Kesslec ECO). | 12 | each | - | - |
| 1.003 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). | 2.2 | cum | - | - |
| 1.004 | OD64832/2026-2027:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel as required. | 105 | kg | - | - |
| 1.005 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm | 216 | metre | - | - |
| 1.006 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.2 X 6 sq. mm (19mm) | 24 | set | - | - |
| 1.007 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | 36 | metre | - | - |
| 1.008 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size | 20 | metre | - | - |
| 1.009 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size | 160 | metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
specificconditionNEW.pdf
Tender Documents • 0.34 MB
BOQ_1494242.xls
BOQ • 0.32 MB
MOM.pdf
Tender Documents • 0.21 MB
viewnit.pdf
Tender Documents • 0.02 MB
viewsbd.pdf
Tender Documents • 2.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .