Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.2 CrAccepted-AOC DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | ₹1.2 Cr Quoted ₹1.0 Cr | 1 | Accepted-AOC Lowest bidder |
| 2 | 2₹1.1 Cr+₹5.2 L (5.17%)Rejected-AOC AMARPUR GOMATI TRIPURA | AMARPUR | GOMATI | TRIPURA | ₹1.1 Cr+₹5.2 L (5.17%) | 2 | Rejected-AOC High Rate |
| 3 | 3₹1.1 Cr+₹10.7 L (10.6%)Rejected-AOC | ₹1.1 Cr+₹10.7 L (10.6%) | 3 | Rejected-AOC High Rate |
| 4 | Rejected-Technical SHIBNAGAR AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical Performance certificate not qualified |
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
28 Jul 2022, 5:00 pmClosed
DGM ED Sonamura
Office of the DGM ED Sonamura
Supply erection commissioning of DTW Scheme
2022_POWER_29966_1
DGM/ED-SNM/22-23/03 dated 13/07/2022
Open Tender
Electrical Works
Works
180 days
ED Sonamura
As per bid document
3 documents required · 3 mandatory
₹10,000
TSECL Settlement Centralised Account
₹2.1 L
Office of DGM ED Sonamura
28 Oct 2022
13 Jul 2022
30 Jul 2022
13 Jul 2022
28 Jul 2022
22 Jul 2022
14 Jul 2022 - 21 Jul 2022
21 Jul 2022
Amount
Supply of the following
a) 9.0 mtr. Long PCC Pole , working load 250Kg.
b) 8.0 mtr. Long PCC Pole , working load 200Kg.
Supply of 11 KV/LT painted stay set complete direct in earth with 16mm. dia. 1.8 mtr. long painted stay rod, one side formed an eye and welded with internal dia 40 mm with one thimble and other side of the rod each threaded and fitted with 2 nos. of suitable hexagonal nuts and with one round MS washer of size 40 X 40 X 2 mm complete with MS Anchor plate of size 300 X 300 X 8 mm, dimension with centre hole of 18 mm dia, Turn buckle of length 356 mm. with 250 mm. long threaded adjustable 16 mm. dia. MS strain rod and thimble including supply & erection of 11 KV/LT guy insulator as per IS specification, hot dip (heavy duty) galvanized stay stranded wire of size 7/2.5 mm. grade - IV as per ISS:2141/1979 having minimum tensile strength 700N/mmsq. with Zinc coating (heavy type coating conforming to IS:4826/1979, fastened with stay clamps as required. ( including supply of MS clamp & Nuts & bolts as reqd) as per TSECL specification)
Galvanized Stranded Stay Wire (7/2.5mm)
11 KV stay Insulator
LT StayInsulator
Supply of 2.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel sub-station bracket including drilling of holes as required for Transformer support
Supply of 0.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel sub-station bracket including drilling of holes as required for Transformer support
Supply of 2.8 mtr. long 75X40X40X6 mm. MS channel bracket for G.O.S & D.O. fuse unit on double steel tubular pole or PCC pole i
Supply of 2.2 mtr. long 75X40X40X6 mm. MS channel bracket for double pole line bracket on double steel tubular pole or PCC pole
Supply of 1.2 mtr. long 75X40X40X6 mm. MS channel bracket for single pole line bracket on steel tubular pole or PCC pole
Supply of 0.3 mtr. long 75X40X40X6 mm. MS channel bracket for single pole line bracket on steel tubular pole or PCC pole
Supply of 2.8 mtr. long 65 X 65 X 6 mm. MS angle sub-station bracket along with drilling of holes as required for using as G.O.S Handle support and fixing
Supply of 1.5 mtr. long 65 X 65 X 6 mm. MS angle along with drilling of holes as required for using as dingle pole guard bracket
Supply of 2.5 mtr. long 65 X 65 X 6 mm. MS angle along with drilling of holes as required for using as double pole guard bkt.
LT 5-wire C-type bracket by 65x65x6 mm MS Angle along with drilling of holes as required for using as stringing of LT line
Supply of 11 KV Polymric Disc Insulator with fittings,nuts&bolts,washers etc. as required complete as per the direction of the engineer In- Charge
Supply of 11 KV Polymric Disc fittings with fittings,nuts&bolts,washers etc. as required complete as per the direction of the engineer In- Charge
Supply of 11 KV Porcelin Pin Insulator with GI PIN complete as per the direction of the engineer In- Charge
Supply of triple pole (3 phase), 12 KV, 200 Amp. drop out fuse unit for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along with Supply of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR.
Supply of triple pole (3 phase), 12 KV, 200 Amp. Manually gang operated, air break switch, 3 post vertical type single brake, complete with post insulator for operation in 11 KV, 50 Hz, AC system as per relevant IS specification with supply of nuts and bolts as required.
Supply of 9 KV, 5 KA single pole metal oxide gapless surge type LA suitable for nominal system voltage of 11 KV, 3 phase, 50 Hz, AC supply. Nominal Creepage distance 300mm. conforming to ISS:3070/1985.
Supply of ACSR conductor 6/1/2.59 mm dia etc. as required
LT Shackle Insulator 3x3.5 mm dia
LT Streaps with Nuts & Bolts
8 SWG GI Wire
16 mm sq PVC cable
Supply of Bracket Camp (50x6mm MS Flat) in/c making holes etc. as required
120 mmsq PVC cable
Nuts and Bolts (Assorted Size)
100 Amp Cut Out
Wooden Plunk 24x12x6 mm
Bimetallic Lugs-120 mmsq
Erection
a) 9.0 mtr. Long PCC Pole , working load 250Kg.
b) 8.0 mtr. Long PCC Pole , working load 200Kg.
Erection of 11 KV/LT painted stay set complete direct in earth with 16mm. dia. 1.8 mtr. long painted stay rod, one side formed an eye and welded with internal dia 40 mm with one thimble and other side of the rod each threaded and fitted with 2 nos. of suitable hexagonal nuts and with one round MS washer of size 40 X 40 X 2 mm complete with MS Anchor plate of size 300 X 300 X 8 mm, dimension with centre hole of 18 mm dia, Turn buckle of length 356 mm. with 250 mm. long threaded adjustable 16 mm. dia. MS strain rod and thimble including supply & erection of 11 KV/LT guy insulator as per IS specification, hot dip (heavy duty) galvanized stay stranded wire of size 7/2.5 mm. grade - IV as per ISS:2141/1979 having minimum tensile strength 700N/mmsq. with Zinc coating (heavy type coating conforming to IS:4826/1979, fastened with stay clamps as required. ( including supply of MS clamp & Nuts & bolts as reqd) as per TSECL specification)
2.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel sub-station bracket including drilling of holes as required for Transformer support
0.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel sub-station bracket including drilling of holes as required for Transformer support
2.8 mtr. long 75X40X40X6 mm. MS channel bracket for G.O.S & D.O. fuse unit on double steel tubular pole or PCC pole i
2.2 mtr. long 75X40X40X6 mm. MS channel bracket for double pole line bracket on double steel tubular pole or PCC pole
1.2 mtr. long 75X40X40X6 mm. MS channel bracket for single pole line bracket on steel tubular pole or PCC pole
0.3 mtr. long 75X40X40X6 mm. MS channel bracket for single pole line bracket on steel tubular pole or PCC pole
2.8 mtr. long 65 X 65 X 6 mm. MS angle sub-station bracket along with drilling of holes as required for using as G.O.S Handle support and fixing
1.5 mtr. long 65 X 65 X 6 mm. MS angle along with drilling of holes as required for using as dingle pole guard bracket
2.5 mtr. long 65 X 65 X 6 mm. MS angle along with drilling of holes as required for using as double pole guard bkt.
LT 5-wire C-type bracket by 65x65x6 mm MS Angle along with drilling of holes as required for using as stringing of LT line
LT Shackle Insulator 3x3.5 mm dia
11 KV Porcelin Pin Insulator with GI PIN complete as per the direction of the engineer In- Charge
11 KV Porcelin Disc Insulator with fittings,nuts&bolts,washers etc. as required complete as per the direction of the engineer In- Charge
Triple pole (3 phase), 12 KV, 200 Amp. drop out fuse unit for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along with Supply of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR.
Triple pole (3 phase), 12 KV, 200 Amp. Manually gang operated, air break switch, 3 post vertical type single brake, complete with post insulator for operation in 11 KV, 50 Hz, AC system as per relevant IS specification with supply of nuts and bolts as required.
9 KV, 5 KA single pole metal oxide gapless surge type LA suitable for nominal system voltage of 11 KV, 3 phase, 50 Hz, AC supply. Nominal Creepage distance 300mm. conforming to ISS:3070/1985.
a) 63 KVA.(TSECL Supply)
Stringing of ACSR conductor 6/1/2.59 mm dia etc. as required
Stringing of 8 SWG GI Wire in/c laying, hoisting, binding etc. as required
Supply and erection of earthing set as per ISS : 3043 of 1966 and with upto date amendment having 2.5 mtr long G.I. pipe (ISI marked) of 40 mm diameter with necessary fabrication,salt&charcoal,lugs,polythene pipe, including a pair of clamps of 50 X 6 mm M.S. flat & 12 mm dia galvanized nuts &bolts,connecting materials i/c excavation, re-filling with alternate layers of salt & charcoal and providing connection of earthing materials and equipments to earth electrode as per REC specification & approved design & drawing of TSECL .
Fixing of LT cut-out with necessary cable connection i/c supply of wooden plank etc as required. (as per the direction of Engineer-in-charge)
Providing 3-phase service connection
Jungle cutting
Renovation and shifting of HT/LT line L.S. Rs.
Carriage:
Carriage of 63 Kva Transformer ( 42 Nos) up to lead range 70 KM from Agartala Store to Sonamura Work site
Hiring of vehicle for site visit/work inspection
UTTAM NAG
BALARAM DAS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .