REPAIR/REPLACEMENT TO UNSERVICEABLE INTERNAL WIRING INCLUDING FITTINGS AND REPAIRING OF CEILING FANS,EXHAUST FANS,GEYSER,AC,WATER COOLERS,REFRIGERATOR ETC IN MD AND OTM ACCN AT MIL STN GANDHIDHAM UNDER GE (ARMY) BHUJ
2023_MES_589496_1
8897
Open Tender
Civil Works
Item Rate
270 days
ARMY AREA BHUJ
REFER TENDER
6 documents required · 6 mandatory
₹500
GE(ARMY) BHUJ
₹41,000
Yes
24 Jun 2023
14 Apr 2023
18 May 2023
14 Apr 2023
16 May 2023
29 Apr 2023
Amount
M&L for Disconnecting,taking down and removing of ceiling fan / Exhaust fan / wall mounting fan of any description, any sweep and from any position / locations and connecting up from ceiling rose or connector to ceiling fan, necessary oiling and greasing including supplying nuts, bolts, canopy, down rod, clamps, capacitor and replacement of unserviceable parts if any, making necessary adjustment and proper alignment of blades, connecting to existing electric sources with using new 1.5 sqmm 3 core multistanded PVC insulated copperwire FRLS to required length and testing at site complete all as specified and directed by accepting officer Note : (i) The unserviceable winding / bearing or any parts shall be paid measured and paid for separately as "supply only" under appropriate item of sch "A" . (ii) Burnt out windings replaced and paid for separately under appropraite item of Sch 'A' . (iii) Labour charges for fixing of items which is mentioned here - in - after as supply only is deemed to be included quoted rate.
Description all as per sil item No 1 here in before but for exhaust/cabin fans of any size/make Note : (i) The unserviceable winding / bearing or any parts shall be paid measured and paid for separately as "supply only" under appropriate item of sch "A" . (ii) Burnt out windings replaced and paid for separately under appropraite item of Sch 'A' . (iii) Labour charges for fixing of items which is mentioned here - in - after as supply only is deemed to be included quoted rate.
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engr-in-charge of ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan complete as directed for the following Fans:- (a) Rewinding of motor of ceiling fans 1200/1400 mm sweep
Supply only bearing of celling fans for celling fans of 1200/1400mm sweep suitable for different makes /type of fans.
Supply only bushes gun metal suitable for celling fans 1200/1400mm sweep/exhaust fan 300 to 450mm sweep/cabin fan of any size complete all as directed by Engr-in-Charge
Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , assembling and testing complete all as specified.
Description all as per srl item NO 6 here- in- before but for cabin/wall fan of any size/make. Note : (i) The unserviceable winding / bearing or any parts shall be paid measured and paid for separately as "supply only" under appropriate item of sch "A" . (ii) Burnt out windings replaced and paid for separately under appropraite item of Sch 'A' . (iii) Labour charges for fixing of items which is mentioned here - in - after as supply only is deemed to be included quoted rate.
Supply only ball bearing suitable for exhaust fan 300 to 450mm sweep of different make, all as directed.
Supply only rubber reel type synthetic rubberwith 14.5 mm hole suitable for hooks of celling fans, all as specified and directed by Engr-in-Charge.
Supply only nuts, bolts and washers of appropriate size for hanging of celling fan including split pins of galvanished iron 1/8" dia, 2" lengthall as specified and directed by Engr-in-Charge.
Supply only top/bottom (Set of Two) canopy of required size complete with tightening screws, all as directed.
Supply only down rod 30cm long made out of heavy grade MS pipe with necessory threading at both ends holes as required with suitable matching colour of ceiling fan 1200/1400mm all as directed
Supply only condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFD all as directed
Description all as per item No 13 here - in - before but capacity 4 MFD for exhaust fan of approved make and quality
Supply only fan blade made out of M S sheet suitable for any make , sweep and colour of celling fans as directed at site by Engr-inCharge
Supply only fan blade (set of three), complete with tightening bolts/screws, made of suitable for any make and colour of exhaust fan as directed at site by Engr- in -Cgarge
Description all as per srl item No 16 here - in - before but for cabain fan of any make and size
M&L for Painting of celling fan 1200/1400mm sweep AC 230 volts single phase complete in site or at contractor workshop with synthetic enameled white/maching paint by spraying one coat including filling of cavities after cleaning all dust complete , all as specified and directed by Engineer-in-Charge .
Supply only exhaust fan frame made out of MS sheet for any make and size of exhaust fan with suitable size of nuts, bolts lugs and washers complete, all as specified and directed by Engineer-in-Charge .
M&L for Painting of exhaust fan 300 to 450 mm sweep AC 230 volts single phase complrtr with synthetic enameled white/grey/matching paint by spraying one coat including filling of cavities after cleaning all dust, all as specified and directed by Engineer-in-charge.
Disconnecting electrically and mechanically the existing geyser of any description, any capacity and make/type and in any position for repair/replacement/painting/cleaning etc including disconnecting existing cold & hot water pipe connections, strip opening of geyser for descaling of tank, element, thermostate, inlet/outlet water pipe connection etc using suitable chemical/wire brush, brazing/soldering/welding of inner tanks for stopping any leakage, replacement of unserviceable parts reassembling the same after, repair/descaling, fixing in position incl, connecting inlet/outlet water pipe connection, electrical connections any testing of geyser complete all as specified and directed. Note : U/s parts replaced with new one shall be measured and paid for separately as "Supply only" under appropriate item of Sch "A"
Supply only of following items for geyser complete.
(a) Apparatus plate heavy duty rubber gasket suitable for 03/06/25/50 Ltr of any size and directed by Engr-in-Charge.
(b) Geyser element 1.5 KW, all as specified. Make :- Theata/Venus
(b) Geyser element 2.0 KW, all as specified. Make :- Theata/Venus
(d) Thermostate switch ISI Marked.
(e) S/S inner tank Capacity 25 Ltrs heavy duty .
(f) S/S Copper inner tank capacity 06 ltr heavy duty .
(g) S/S Copper inner tank capacity 50 Ltr heavy duty .
(h) Indicator lamp of any type/colour.
(i) Top and bottom cover of outer body of any type Geyser suitable for 03/06/25/50 lts capacity including two coats of synthetic enamelled paint and preparation of surfaces. All as specified.
(j) CP connection 450mm long nylon braided and double flat with nut and washers both side complete all as specified.
(k) -do- but of size 300mm long.
(l) Copper flexible cable PVC insulated 3 core 40/.0076 All as specified and directed.
(m) Outer body 50 Ltr capacity Geyser sutaible for exesting make.
(o) Outer body but 25 ltr capacity Geyser sutaible for exesting make.
(p) Pressure release valve ISI marked.
(q) Safty plug of geyser for 25/35/50 Ltr capacity.
(r) Plug top 3pin 15 Amps ISI Marked .
(s) Non return valve 15mm dia pipe brass made ISI marked.
Labour only for repairing and attending the complaint of Split/WindowAC/ Water cooler/Refrigerator/deep freezer by highly skilled tradesman and carryout minor repair and making functional complete all as specified and directed at site. Note :- (replacement of spare part will be measured and paid separately under appropriate items )
Disconnecnting, dismantling and taking out the non functional Air Conditioner window type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
Disconnecnting, dismantling and taking out the non functional Air Conditioner Split type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :- Note :- (replacement of spare part will be measured and paid separately under appropriate items )
(a) Water coolers 40 to 150 ltrs cooling capacity.
(b) Refrigerator of 165 to 310 ltrs capacity.
(c) Deep freezers of Upto 425 ltrs capacity.
Taking down defective /unserviceable AC compressor of any make of capacity 1.5 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of window AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 2.0 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of window AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 1.5 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of Split AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 2.0 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of Split AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure complete all as specified and directed by Engr-in-Charge for the following appliances:-
(a) Split type AC 1.5/2 Ton capacity.
(b) Window type AC 1.5/2.0 Ton capacity
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only starting relay complete all as specified and directed by Engr-in-Charge. for the following appliances:-Make- Hitech
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only capacitors of the following capactities for ACs water coolers, refrigerators, Deep frizers etc as per site requirement.
Supply, installation including brazing, jointing copper tubing superior quality of dia 5/8” completes all as specified and as directed by Engineer-in-charge.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/2” completes all as specified and as directed by Engineer-in-charge.
Supply, installation including brazing, jointing copper tubing superior quality of dia 3/8” completes all as specified and as directed by Engineer-in-charge.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/4” completes all as specified and as directed by Engineer-in-charge.
M&L for shifting of split type AC from one location to other location including fixing evaporator unit with gitties/fastner, cutting wall/concrete incl arrangement of T&P for laying copper tubing, positioning condensing unit, laying copper tubing incl brazing work, connecting drain pipe, making good disturbed surface complete all as specified and as directed by engineer-in-Charge. (Note- Any additional copper tubing required for the work is included in the item)
S&F in replacement of remote control ( micro- processor) unit suitable make of split type AC 1.5/ 2 TR.
Supply only thermostats of of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c ) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only overload protector of followings :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c ) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Preparation of old painted surfaces of the following appliacnes, painting with two coats of synthetic enamel paint by spraying all as directed by Engr-in-charge for :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only condenser unit of the following appliances including making of all connectiions as specified and directed by Engr-in-charge following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only cooling coil of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
(c) Water coolers 40 to 150 ltrs capacity.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of Upto 425 ltrs capacity.
Supply only magnetic door gasket of refrigerant 165 to 310 Ltrs cpacity.
Supply only top cover gasket of water cooler 40 to 150 ltrs capacity.
Supply onlye freeze compartment door/cover of refrigerators upto 310 ltrs of any make.
Supply only ice tray with PVC cubicle separater.
Supply only cabinet bulb of refrigerators of suitable size and capacity.
Supply only internal wiring kit complete sutaible for following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Water coolers 40 to 150 ltrs capacity.
(c) Split type AC of any make and capcity 1.5/2 ton.
(d) Refrigerator of 165 to 310 ltrs capacity.
(e) Deep freezers of any make & cap 200 to 425 ltrs capacity.
Supply only condenser fan motor complete with necessary mounting bracke to and base frames for :-
(a) Window type AC of any make capactiy 1.5 Ton cap.
(b) Water coolers of any make and cap 40 to 150 ltrs capacity.
(c) Split type AC of any make and capcity 1.5/2 ton.
(d) Deep freezers of any make & cap 200 to 425 ltrs capacity.
Supply only bottom tray of window type ACs 1.5/2.0 Ton capacity of any make complete all as specified and as directed by Engineer-in-Charge.
Supply only heavy duty PVC flexible pipe with necessary jubilee clamps for water cooler/split ACs/Window ACs drains of size :-
(a) 15mm dia bore.
(b) 20 mm dia bore.
Supply only PCB of split type AC Cap 1.5/ 2 TR as per existing make and model. Complete all as specified and directed by Engrs - in- charge.
M&L, for providing rubber foam heavy duty insulation tube over the existing copper tubing of any length at any location in replacement of worn out insulation including fixing with cable tie, clamping all as required at site, complete all as specified and directed by Engr-in-Charge.
Supply only front grill of window type AC as per sample, complete all as specified and directed by Engr-in-Charge.
Supply only air filters of split type AC of 1.5/2.0 TR capacity as per existing pattern, complete all as specified and directed by Engr-in-Charge.
Supply only new coling fan motor for window type AC1.5TR/2TR, complete all as specified and directed by Engr-in-Charge.
Supply only new cooling fan motor for split type AC of 1.5/2.0 TR capacity, complete all as specified and directed by Engr-in-Charge.
Supply and fixing new chasis in replacement to worn out chasis of window type AC comprises of bottom cover new cooling coil, condenser coil, motor, blower,propeller fan capillary, filter, outer cover duly powder coated all as specified and as directed by Engineer-in-Charge.Make- Voltas/ LG
Supply and fixing indoor unit of split type AC 2 TR in replacement of worn out unit Comprises of cooling coil, blower, blower motor, swing motor,swing blade filter, PCB, Thermostate, complete all as specified and as directed by Engineer-in-charge. Make- Voltas/ LG
Supply and fixing in replacement to worn out door unit of split type AC of cap 2 TR. comprises of condensor, condenser motor, condensor fan and blade , capacitor, suction, discharge valve, outer cover duly powder coated all as specified and as directed by Engineer-in-Charge.Make-Voltas/ LG.
Supply & Fix in replacement MS stand factory made suitable for condensing unit of split type AC duly powder coated all as specified and as directed by Engineeer-in-Charge.
M&L for cleaning after taking down complete body including fitting and fixtures of desert coolers of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamenl spray paint inside and outside surfaces and applying two coats rubber seal paint inside the water tank etc, complete all as specified and directed by Engr-in-Charge.
S&F in replacement Submersible PVC pump for desert cooler 230 volt single phase 50 HZ complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of fan motor copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed by Engineer-in-Charge.
Supply & replacement of wood wool pad ( Set of three) heavy duty for desert cooler complete all as directed by Engr-in-charge.
Supply & fixing in replacement of capacitor 4 mfd make Usha/Universal/Epcos
Supply & fixing in replacement desert cooler fan blades made of galvanised iron sheet of appropriate thickness as directed.
Supply & fixing in replacement of old rusted front panel with show grill of desert cooler with new grill made out of GI sheet 22 SWG complete with front show plate with ON/OFF switch for pump & four speed regulator for fan of approved make all as specified and as directed by Engr-in-Charge.
S&F in replacement of 3 Pin Top, 5 Amp for desert coolers, complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable water cooler (capacity 40 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable refrigarator (upto capacity 260 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable Refrigrator (upto capacity 320 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable Deep frizer (capacity upto 425 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
S&F in replacement of water tap for water cooler of capacity 40 Ltrs / 150 Ltrs, complete all as specified and directed by Engr-in-Charge.
M&L for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas as per existing for water cooler, complete all as specified and directed by Engr-in-Charge.
S & F in replacement of float valve assembly Complete suitable for water cooler of any size/cap Non metallic body complete all as specified and directed by Engr-in-Charge.Make:- Symet/prayag
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fitting and fixture and such as as switches, sockets ceiling rose,pendent holders,regulators,light fittings any type removing materials to store in safe custody or for credite etc, and making good the disturbed surface of walls and floors etc as directed.
M&L for point wiring with two single core PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm 1100 volts grade in and including PVC casing capping of size 20 to 25 mm with all accessories and one single core PVC insulated unsheathed solid copper cable of size 1.5 Sqmm 1100 Volts grade as earth continuity conductor connected to common earth dolly, switch board complete with PVC / Sheet metal box heavy duty for mounting the switch socket including all fixing acessories etc complete as specified for the following :- (a) One light/Fan/Exhaust fan point controlled by one 5 Amps switch one way complete
- ditto-- but One bell point controlled by one 5 Amp bell push complete
--dotto-- but one 5 Amp socket point controlled by one 5 Amp switch independent board with cable 2.5 sqmm.
–ditto- but on the same board.
All as per item No.88 here-in-before but with two single core PVC insulated unsheathed copper conductor cable of size 2.5 Sqmm 1100 volts grade and one single core PVC insulated unsheathed solid copper conductor cable of size 2.5 Sqmm 1100 Volts grade as earth continuity conductor for 3 pin 15 Amps socket point on independent board complete all as specified and as directed.
S&F switch piano flush type 6 Amp. AC, 240 Volts one way all as directed.
S&F switch piano flush type 15 Amp. AC, 240 Volts one way all as directed.
S&F bell push flush type single pole one way, 5 Amp, AC,230 V all as directed.
S&F switch socket combination. Multi purpose 6 Pin 6 Amp flush type AC, 230V complete all as directed.
S&F switch socket combination. Multi purpose 6 Pin 16 Amp flush type , AC, 230V complete all as directed.
S&F ceiling Rose, surface, bakelite 65 x50 mm three terminals, AC, 230 Volts complete all as directed.
S&F angle holder backelite with insulated body AC, 230V complete all as directed.
S&F bell electric AC, 230V, Single phase, Dingdong type complete all as directed.
S&F step type electronices fan regulator flush type, 100 watt, AC, 230V, Single phase, complete all as directed.
S&F modular type electronices fan regulator, 100 watt, AC, 230V, Single phase, complete all as directed.
S&F Modular switch 1 way 6A 1 module type all as directed.
S&F Modular switch 1 way 16A 1 module type all as directed.
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module all as directed.
S&F Modular Switch socket Combination 16A, 6 pin, 3 module all as directed.
S&F in repair square recessed / surface/suspended mounting LED slim ceiling light with extruded aluminium housing and milky diffuser of 36 W 2'X 2' slim panel LED driver 240 V ,50 Hz complete all as specified & approved by EIC.
S&F in repair decorative box type fitting with LED tube 18 to 20 watt for 230 volt AC complete including making all connection using 1.5 sqmm copper conductor muilstranded PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit all as specified & approved by EIC.
S&F in repair Sleek LED mirror light 10 watt rating with diffuser 2ft long twisted flexible copper wire complete all as specified & approved by EIC.
M&L in repair for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 6 Sqmm 1100 volts grade and one run of PVC insulated unsheathed solid copper conductor cable of size 6 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc including taking out old unserviceable burnt/damaged sub main wiring from its existing position complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).
M&L in repair for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 4 Sqmm 1100 volts grade and one run of PVC insulated unsheathed solid copper conductor cable of size 4 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed / surface conduit of suitable size on roof/wall/ceiling including making good the disturbed surfaces of wall etc including taking out old unserviceable burnt/damaged sub main wiring from its existing position complete all as directed by Engr-in-Charge (Note : Two run of single core cable and one run of earth wire will be measured as one length and conduit and its accessories is deemed to be included in the unit rate).
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 6 Sqmm solid aluminium conductor all as specifiied and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flexible two core cable flat or circular of size 10 Sqmm solid aluminium conductor all as specifiied and directed.
Taking down old unserviceable main switches/DB’s up to 100 Amps capacity fixed in wall and making good of all disturbed surfaces as per existing .
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 4 way, AC,240 volt with 200 Amp bus bar rating complete all as directed.
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 8 way, AC,240 volt with 200 amp bus bar rating complete all as directed.
S&F sheet metal enclosure for DB’s when MCB to be used single pole and neutral double door, 12 way, AC,240 volt with 200 Amp bus bar rating complete all as directed.
S&F sheet metal enclosure double door (MCB DB) three phase and neutral with 200 Amps rated bus bar TPN, 4 way horizontal type, with provision of MCB incommer, AC, 415 Volt complete all as specified & directed.
S&F sheet metal enclosure double door (MCCB DB) three phase and neutral with 200 Amps rated bus bar TPN, 4 way vertical type, with provision of MCCB incommer, AC, 415 Volt complete all as specified & directed.
S&F MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.
S&F MCB single pole, 40 to 63 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.
S&F MCB DP 32 to 63 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.
S&F MCB Four Pole 40 to 63 Amps 415 Volts, 50 Hz, 10 KA breaking capacity complete all as directed.
S&F for sheet metal enclosures with two pin and earth plug sockets controlled by one No. MCB rating 20 Amps , 240 Volts grade, double door type complete.
M&L , Earthing complete with galvanisedsteel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completionI connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.
Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.
(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.
Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
S&F in repair decorative surface mounting LED dwonlighting with white diffuser 05 watt luminaire for 230 volt AC complete all as specified & approved by EIC.
S&F in repair decorative surface mounting LED dwonlighting with white diffuser 10 watt luminaire for 230 volt AC complete all as specified & approved by EIC.
(1) The contractor shall keep all items readily available at site, which is required for urgent repair works of appliances.
(3) Common miscellaneous material such as screws any type, nails, washers, insulation tapes, clamps, hooks, which are required for the work the cost of which is deemed to be included in quoted rate.
(4) All tools &tackles, plants, machineries, equipment and material to carry out the work at site which is to be decided by GE (A) Bhuj shall have to be provided by the contractor at his/ her own cost. Workshop shall be setup for rewinding/ repair of ceiling fan, exhaust fan, wall mounted fan, refrigerator, deep freezer & desert cooler. Rewinding machine should be installed in workshop with the latest configuration.
(5) Contractor’s supervisor (electrical engineer) should be available at the site to supervise the works and co-ordinate with the officials.
(7) The manpower shall be issued identity card after getting due verification. Uniform should be worn by the manpower having monogram of the firm.
(8) The skilled worker should be facilited with mobile phone to contact on urgent tasks & their numbers should be displayed at various places and forwarded to administration.
(9) The contractor shall ensure safety of his workers and other at site of work and shall be responsible for any consequence arising out of execution of the repair and maintenance works.
(10) The contractor shall ensure that his repair/ maintenance staff is qualified and licensed for their part of work. He shall be responsible for their conduct. The contractor shall be held responsible for any loss or damage to employees’ state insurance corporates property.
(12) The date of repair, unit name & serial number shall be mentioned in neat sticker in the appliances after repair.
(13) Contractor is to collect the faulty appliances from units & return them after repair within a week. No separate charges shall be given for transportation.
(15) It is responsibility of contractor to clean the area after repairwork of appliances. Rates are deemed to be include in his quoted rates of respective items.
(16) The same nature of complaints in same location shall be counted as one complaint in internal electrification. Job card and complaint register for entry of complaints shall be provided at his/ her own cost.
(18) Any of contractor persons causes damage of equipment or property of Militart station, the contactor will be solely held responsible for the cost of consequences thereof.
(i While the compressor, of any machne is found burn the contactor will intimate the same to AGE EM ,AGE EM will intimate to GE alongwith PRB Book and takking approval for replacement.(ii) The replacement of Indoor unit of Split type AC of any size shall be carried out with approval of Accepting officer.
(21) Contractor shall identify the real cause of burned winding of fan motor. Winding problems that are identified should be documented. Then, winding of fan motors shall be cut/ removed completely in presence of officials. Rewinding of same shall be carried out with proper copper gauge wire.
M/s Bombay Novelty Stores
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .