Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹15.8 L+₹95,175 (6.43%)Admitted-Finance OFFICE 408 SHLOK INFINITY OPP VISHWAKARMA MANDIR CHANDLODIA AHMEDABAD GUJARAT 382481 | AHMADABAD | GUJARAT | 382481 | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | VINAY ELECTRICALS L1 | RUDRAVEER ELECTROMECH PROJECTS PRIVATE LIMITED L2 |
|---|---|---|---|---|---|
| 1.00 | Preventive Maintenance of LT motors & its feeders/breakers of 415V, 3-phase induction motors of power rating up to 7.5KW. Job involves for preventive maintenance at motor side:- checked the motor terminal condition, cleaning & tightening of terminals and terminal links take the inductance, resistance & IR values with motor checker. Ensure earthing else rectify the same with suitable size wire/strip. For 415 Volt feeder side, jobs includes :- rack out the feeders, check the power contactors, power & control Fuses, tighten all power/control connections, cleaning of the feeders & control terminals etc. Check the coil resistance of the contractor. Replacement of overheated lugs at motor/ feeder side if observed, same should be replaced with new one. The job shall be carried out as per technical specifications given in tender document. | 134 | Nos | 250 ₹33,500 Lowest | 500 ₹67,000 |
| 2.00 | Preventive Maintenance of LT motors & its feeders/breakers of 415V, 3-phase induction motors of power rating from 9.0KW to 45KW. Job involves for preventive maintenance at motor side:- checked the motor terminal condition, cleaning & tightening of terminals and terminal links take the inductance, resistance & IR values with motor checker. Ensure earthing else rectify the same with suitable size wire/strip. For 415 Volt feeder side, jobs includes :- rack out the feeders, check the power contactors, power & control Fuses, tighten all power/control connections, cleaning of the feeders & control terminals etc. Check the coil resistance of the contractor. Replacement of overheated lugs at motor/ feeder side if observed, same should be replaced with new one. The job shall be carried out as per technical specifications given in tender document. | 18 | Nos | 500 ₹9,000 Lowest | 750 ₹13,500 |
| 3.00 | Preventive Maintenance of LT motors & its feeders/breakers of 415V, 3-phase induction motors of power rating from 50KW to 90KW. Job involves for preventive maintenance at motor side:- checked the motor terminal condition, cleaning & tightening of terminals and terminal links take the inductance, resistance & IR values with motor checker. Ensure earthing else rectify the same with suitable size wire/strip. For 415 Volt feeder side, jobs includes :- rack out the feeders, check the power contactors, power & control Fuses, tighten all power/control connections, cleaning of the feeders & control terminals etc. Check the coil resistance of the contractor. Replacement of overheated lugs at motor/ feeder side if observed, same should be replaced with new one. The job shall be carried out as per technical specifications given in tender document. | 5 | Nos | 4,000 ₹20,000 | 1,000 ₹5,000 Lowest |
| 4.00 | Preventive Maintenance of LT motors & its feeders/breakers of 415V, 3-phase induction motors of power rating from 110 KW to 132KW. Job involves for preventive maintenance at motor side:- checked the motor terminal condition, cleaning & tightening of terminals and terminal links take the inductance, resistance & IR values with motor checker. Ensure earthing else rectify the same with suitable size wire/strip. For 415 Volt feeder side, jobs includes :- rack out the feeders, check the power contactors, power & control Fuses, tighten all power/control connections, cleaning of the feeders & control terminals etc. Check the coil resistance of the contractor. Replacement of overheated lugs at motor/ feeder side if observed, same should be replaced with new one. The job shall be carried out as per technical specifications given in tender document. | 5 | Nos | 4,000 ₹20,000 | 1,500 ₹7,500 Lowest |
| 5.00 | Monitoring and logging of parameters of 66KV switch yard equipment, transformers, battery charger, UPS, motors etc. in each shift (RTC shift) as per the log sheet and as per technical specifications given in tender document. | 1,095 | Job | 90 ₹98,550 | 75 ₹82,125 Lowest |
| 6.00 | Up keeping & maintenance of individual cells of Class-I &II stationary battery bank :Job includes the cleaning & measuring the cell voltage, specific gravity of the electrolyte of the Cell. Check the tightness of the cell connections. Maintain the electrolyte level of the cell. This job shall be carried out in RTC shift and the job also includes monitoring and logging of parameters of battery charger and UPS to ensure healthiness of battery banks. In addition assisting in other maintenance job during the shift as per technical specifications given in tender document. | 5,520 | Nos | 60 ₹3,31,200 Lowest | 100 ₹5,52,000 |
| 7.00 | Up keeping & maintenance of (2X12V) battery set of diesel fire pump as per technical specifications given in tender document. | 52 | Nos | 800 ₹41,600 | 750 ₹39,000 Lowest |
| 8.00 | Carrying isolations of circuit breaker/ isolator /MCB as per permit/AVI to ensure de-energization of equipments /system for carrying out maintenance work and subsequent normalization of circuit breaker/ isolator /MCB after completion of maintenance work and surrender of permit including connection/disconnection of cable as where required. In addition to above receiving, registering of complaints and rectification of minor faults in power circuit/ motor is also in the scope of contractor as per technical specifications given in tender document. | 1,600 | Nos | 250 ₹4,00,000 Lowest | 350 ₹5,60,000 |
| 9.00 | Carrying out weekly / monthly surveillance test/during class-IV failure of 310KVA DG set or 250KVA DG set as per checklist including surveillance check up of connected Battery, logging parameters and diesel top up as per technical specifications given in tender document. | 60 | Nos | 1,000 ₹60,000 | 500 ₹30,000 Lowest |
| 10.00 | Supply and apply of petroleum jelly on battery terminals | 5 | Kg | 300 ₹1,500 Lowest | 500 ₹2,500 |
Tender Value
₹16.2 L
EMD Value
₹32,355
Closing Date
9 Sept 2025, 6:00 pmClosed
General Manager
Heavy Water Board Facilities, Vadodara
Annual contract for condition monitoring and maintenance of substation and plant electrical equipment in RTC shift at HWBF-Vadodara for the year 2025-2026
2025_HWB_873188_1
HWBF/V/E-2279/2025-26/RTC shift
Open Tender
Electrical Works
Item Rate
365 days
Vadodara
As per NIT and tender document
2 documents required · 2 mandatory
₹0
₹32,355
Heavy Water Board Facilities
19 Sept 2025
18 Aug 2025
13 Sept 2025
18 Aug 2025
9 Sept 2025
18 Aug 2025
18 Aug 2025 - 6 Sept 2025
6 Sept 2025
Amount
Preventive Maintenance of LT motors & its feeders/breakers of 415V, 3-phase induction motors of power rating up to 7.5KW. Job involves for preventive maintenance at motor side:- checked the motor terminal condition, cleaning & tightening of terminals and terminal links take the inductance, resistance & IR values with motor checker. Ensure earthing else rectify the same with suitable size wire/strip. For 415 Volt feeder side, jobs includes :- rack out the feeders, check the power contactors, power & control Fuses, tighten all power/control connections, cleaning of the feeders & control terminals etc. Check the coil resistance of the contractor. Replacement of overheated lugs at motor/ feeder side if observed, same should be replaced with new one. The job shall be carried out as per technical specifications given in tender document.
Preventive Maintenance of LT motors & its feeders/breakers of 415V, 3-phase induction motors of power rating from 9.0KW to 45KW. Job involves for preventive maintenance at motor side:- checked the motor terminal condition, cleaning & tightening of terminals and terminal links take the inductance, resistance & IR values with motor checker. Ensure earthing else rectify the same with suitable size wire/strip. For 415 Volt feeder side, jobs includes :- rack out the feeders, check the power contactors, power & control Fuses, tighten all power/control connections, cleaning of the feeders & control terminals etc. Check the coil resistance of the contractor. Replacement of overheated lugs at motor/ feeder side if observed, same should be replaced with new one. The job shall be carried out as per technical specifications given in tender document.
Preventive Maintenance of LT motors & its feeders/breakers of 415V, 3-phase induction motors of power rating from 50KW to 90KW. Job involves for preventive maintenance at motor side:- checked the motor terminal condition, cleaning & tightening of terminals and terminal links take the inductance, resistance & IR values with motor checker. Ensure earthing else rectify the same with suitable size wire/strip. For 415 Volt feeder side, jobs includes :- rack out the feeders, check the power contactors, power & control Fuses, tighten all power/control connections, cleaning of the feeders & control terminals etc. Check the coil resistance of the contractor. Replacement of overheated lugs at motor/ feeder side if observed, same should be replaced with new one. The job shall be carried out as per technical specifications given in tender document.
Preventive Maintenance of LT motors & its feeders/breakers of 415V, 3-phase induction motors of power rating from 110 KW to 132KW. Job involves for preventive maintenance at motor side:- checked the motor terminal condition, cleaning & tightening of terminals and terminal links take the inductance, resistance & IR values with motor checker. Ensure earthing else rectify the same with suitable size wire/strip. For 415 Volt feeder side, jobs includes :- rack out the feeders, check the power contactors, power & control Fuses, tighten all power/control connections, cleaning of the feeders & control terminals etc. Check the coil resistance of the contractor. Replacement of overheated lugs at motor/ feeder side if observed, same should be replaced with new one. The job shall be carried out as per technical specifications given in tender document.
Monitoring and logging of parameters of 66KV switch yard equipment, transformers, battery charger, UPS, motors etc. in each shift (RTC shift) as per the log sheet and as per technical specifications given in tender document.
Up keeping & maintenance of individual cells of Class-I &II stationary battery bank :Job includes the cleaning & measuring the cell voltage, specific gravity of the electrolyte of the Cell. Check the tightness of the cell connections. Maintain the electrolyte level of the cell. This job shall be carried out in RTC shift and the job also includes monitoring and logging of parameters of battery charger and UPS to ensure healthiness of battery banks. In addition assisting in other maintenance job during the shift as per technical specifications given in tender document.
Up keeping & maintenance of (2X12V) battery set of diesel fire pump as per technical specifications given in tender document.
Carrying isolations of circuit breaker/ isolator /MCB as per permit/AVI to ensure de-energization of equipments /system for carrying out maintenance work and subsequent normalization of circuit breaker/ isolator /MCB after completion of maintenance work and surrender of permit including connection/disconnection of cable as where required. In addition to above receiving, registering of complaints and rectification of minor faults in power circuit/ motor is also in the scope of contractor as per technical specifications given in tender document.
Carrying out weekly / monthly surveillance test/during class-IV failure of 310KVA DG set or 250KVA DG set as per checklist including surveillance check up of connected Battery, logging parameters and diesel top up as per technical specifications given in tender document.
Supply and apply of petroleum jelly on battery terminals
Supply and apply of IOCL/HPCL/BPCL make multipurpose grease confirming to NLGI grade 3 confirming to IS:7623.
Supply and apply of M-seal/Anabond 100gm pack multipurpose sealant.
Supply and replacement of rubberized cork sheet of size 915mmX915mm, thickness of 6mm confirming to IS: 4253.
Supply and apply of bitumen flash strip roll of width: 40-60mm, length: 10 mtrs.
Supply and replacement of 500W halogen lamp
Supply and replacement of 1000W halogen lamp
Supply and replacement of 1/2" size, 10LPM magnetic operated flow switches with float arrangement along with valve and proximity switch (NO type) along with BSP threaded connection at both sides including mounting arrangement as per technical specifications given in tender document.
Supply and replacement of proximity switch as per technical specifications given in tender document.
Supply and fixing of neoprene rubber sheet of thickness 3mm, width: 1200mm and length: 1000mm
Supply and replacement of microporous vent caps suitable for EXIDE make TX 600P model battery bank as per technical specifications given in tender document.
Supply and replacement of lead coated insulated copper inter cell connectors suitable for EXIDE make TX 600P model battery bank as per technical specifications given in tender document.
Supply and replacement of microporous vent caps suitable for EXIDE make TX 100P model battery bank as per technical specifications given in tender document.
Supply and replacement of contactor coil suitable for L&T make MK1 type DOL starter, coil voltage is 360V AC, operating limits: 280V-420V
Supply and replacement of NO/NC contact element block for push buttons with 240V, 3A rating as per technical specifications given in tender document.
Supply and replacement of RED colour mushroom head emergency trip push button actuator as per technical specifications given in tender document.
Supply and replacement of GREEN/RED/YELLOW/BLACK colour flush head metal push button actuator of size 22.5mm as per technical specifications given in tender document.
Supply of drill bits of size 1 mm to 10mm, 12mm, 14mm and 16mm suitable for drilling metals as per technical specifications given in tender document.
Supply and installation of 1-phase, MF type L&T or equivalent DOL starter suitable for 1-phase motor having power rating up to 1.0 HP as per technical specifications given in tender document.
Supply and installation of 230V, 4-inch, 19W, 2650rpm axial cooling fans for electrical panels as per technical specifications given in tender document
Supply and installation of 230V, 6-inch 45/39W cooling fans for panels as per technical specifications given in tender document.
Supply and replacement of control card for autonics make 3-phase AC voltage controller as per technical specifications given in tender document.
Supply of hydrometer for checking specific gravity of electrolyte of lead acid battery
Supply and replacement of insulated lead coated terminal blot of size M10X23mm with test point suitable for EXIDE make TX 600P model battery bank as per technical specifications given in tender document.
Supply and installation of heavy duty drilling machine suitable for mounting on existing bench type drilling machine of WOLF make, model No. as per technical specifications given in tender document.
RUDRAVEER ELECTROMECH PROJECTS PRIVATE LIMITED (BID ID -3272748)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .