Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Technically Unsuitable |
| 4 | Rejected-Technical 61 3 37 VENKANNAPALEM MALKAPURAM MALKAPURAM VISAKHAPATNAM ANDHRA PRADESH 530011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | Rejected-Technical Technically Unsuitable |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
19 May 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Manager SRC-OS
Hindustan Shipyard Limited Gandhigram SR Complex Visakhapatnam 530 005
HABITABILITY WORKS ON INS JAMUNA
2025_HSL_97282_1
20 / 22040 / 96 / HABITABILITY WORKS/ 2025-26
Open Limited
Miscellaneous Services
Service
120 days
HSL Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹840
Yes
hsl
₹90,000
Yes
4 Jul 2025
29 Apr 2025
19 May 2025
29 Apr 2025
19 May 2025
29 Apr 2025
Amount
Habitability works of various compartments on INS JAMUNA
SUPPLY AND INSTALLATION OF 15 IN NO CUBICAL WCs PANEL . JOB INVOLVES INSTALLATION OF STAINLESS STEEL PANELS WITH INSPECTION WINDOW 250 mm ABOVE THE DECK LEVEL, ALONG WITH FITMENT OF LOCK, HOLDING FAUCET AND WATER TAP ARRANGEMENT OF CUBICLES. REPAIR OF DADEO CASTING 10 SQM
SUPPLY AND INSTALLATION 10 IN NO.s SHOP DISPENSOR- 3X6 INCHES, AS PER SAMPLE.
SUPPLY AND FITTMENT OF LOCKING ARRANGEMENT OF MESS LOCKERS - 1X0.8 MTR EACH JOB INVOLVES CHANGING AND FITMENT OF LOCKS, REPLACEMENT OF SLIDING CHANNEL AND REPLACEMENT OF DAMAGED LOCKER DOOR. JOB INVOLVES FITMENT OF MAGNETIC CATCH. MAT- CRCA
SUPPLY AND FITTMENT OF LOCKING ARRANGEMENT OF CUPBOARDS - 1.8X1 MTR EACH JOB INVOLVES CHANGING AND FITMENT OF LOCKS, REPLACEMENT OF SLIDING CHANNEL AND REPLACEMENT OF DAMAGED LOCKER DOOR. JOB INVOLVES FITMENT OF MAGNETIC CATCH. MAT- CRCA
SUPPLY AND FITTMENT OF LOCKING ARRANGEMENT OF SHOE LOCKERS - 1X1.5 MTR EACH JOB INVOLVES CHANGING AND FITMENT OF LOCKS, REPLACEMENT OF SLIDING CHANNEL AND REPLACEMENT OF DAMAGED LOCKER DOOR. JOB INVOLVES FITMENT OF MAGNETIC CATCH. MAT- CRCA
SUPPLY AND INSTALLATION OF PERFORATED SHEET PANELLING AT GUN DECK 90 SQMTR , SHIPS GALLEY 250 SQMTR, ATUs - 140 SQMTR, ELECTRONIC EQUIPMENT COMPRTMENTS - 250 SQM, MESSES AND OFFICE SPACES 700 SQM . JOB INVOLVES WELDING OF SECURING BRACKETS AT INDICATED LOCATIONS.
SUPPLY AND INSTALLATION OF SS SANDWITCH PANELLING OF BATHROOMS AND WCs JOB INVOLVES WELDING OF SECURING BRACKETS AT INDICATED LOCATIONS.
SUPPLY AND INSTALLATIONOF DECK HEAD PANEL AT BRIDGE AND VARIOUS COMPARMENTS . JOB INVOLVES RENEWAL OF PANEL WITH ALL ACCESSORIES AS PER SAMPLE, MAT- AL.
RUNGS AND INTERMEDIATE STEPS OF VERTICAL LADDER THINNED, CORRODED / PERISHED TO BE REPAIRED. (MAT- MS/ WOODEN). INCLUDING WOODEN LADDER AT CAPTAIN LOBBY (QTY- 5), DIMENTION- 2.5X0.5 MTR APPROX
SLIDING ARRANGEMENT OF NON WT DOOR DAMAGED. TO BE REPAIRED/ RENEWED. JOB INVOLVES CHANGING OF SLIDING CHANNELS / ROLLER MECHANISM-70 NOS FOR DOOR AND FRAME.
12 IN NO.s METALLIC NWT DOOR WITH FRAME DAMAGED/ BROKEN. TO BE MANUFACTURED AND FITTED IN SITU. DOORS CONSIST OF , BOTH SIDE LOCKING ARRANGEMENT. DIMENTION - 1.75X1 MTR EACH MAT - MS
SUPPLY AND INSTALLATION OF WASH BASIN AND IT'S FITTINGS ON WC'S. MAT - SS. JOB INVOLVES CHANGING OF DAMAGED WASH BASIN (QTY-10 OF SS ), (TAPS- 10, BOTTLE TRAP - 10 AND CONNECTION WITH INLET LINE AND DRAINAGE SYSTEM ) .MAKE :- JAGUAR
KICK OUT PANEL OF NON WATER TIGHT DOOR DAMAGED / BROKEN, TO BE RENEWED WITH HINGES AND LOCKING MACHENISM. DIMENSION - 0.75X0.85 MTR EACH MAT - CRCA
HYDRAULIC DOOR CLOSER OF NON WATER TIGHT DOOR DEFECTIVE/ BROKEN, TO BE REPLACED. MAKE- GODREJ LTD
HULL OFFICE NWT DOOR DEFCTIVE/ DAMAGED. TO BE RENEWED. JOB INVOLVES CHANGING OF MORTOISE LOCKS- 1 NOS AND SLIDING CHANNELS / ROLLER MECHANISM- 1 NOS FOR DOOR AND FRAME. DIMENTION - 1.75X1 MTR
WOODEN RACKS FOR GYRO/EMR/BRIDGE LOCKERS/SRE/TELE EXCHANGE/EMR COMPARTMENT AT VARIOUS LOCATION'S DAMAGED/ PERISHED. TO BE MANUFACTURED AND REPLACED AS PER EXISTING SIZE.MAT-CRCA QTY- 50 DIMENTION- 1.2X1.5 EACH
SUPPLY AND FITMENT OF 20 TAPS BROKEN/ DAMAGED AT SCATTERED LOCATIONS.TO BE REPLACED WITH NEW. SIZE- VARIOUS SIZES MAT-SS. MAKE - JAQUAR
SUPPLY AND INSTALLATION OF UTENSIL RACK IN SHIP'S GALLEY, MCPO’S MESS, JSDH, SSDH, DAMAGED TO BE RENEWED IN SITU. JOB INVOLVES MANUFACTURING OF UTENSIL RACKS AND WELDING IN SITU WITH SUPPORTING BRACKETS. MAT- SS,AS PER SIZE , DIMENTION- 1X1.5 MTR EACH RACK MAT -SS
LOCKING ARRANGEMENT OF COOL AND COLD ROOM DAMAGED. TO BE REPAIRED/ RENEWED IN SITU. MAT- SS, MAKE- GODREJ LTD
METALLIC RACK IS DAMAGED AT VARIOUS LOCATIONS. TO BE MANUFACTURED. RACK TO BE INSTALLED IN-SITU, AS PER SIZE, MAT- MS/SS, SIZE- 1X1.5 MTR
CUP BOARDS AT VARIOUS LOCATIONS DAMAGED. TO BE MANUFACTURED AND FIXED INSITU. JOB INVOLVES REPLACEMENT OF CUPBOARDS/ LOCKERS WITH SUPPORTING BRACKETS AS PER SIZE MAT- CRCA. DIMENTION - 1.8X1 MTR
STORAGE BOXES KEPT AT VARIOUS LOCATIONS DETERIORATED. TO BE REPAIRED/ RENEWED IN SITU. JOB INVOLVES MANUFACTURING OF BOX AS PER DIMENSIONS AND SECURED IN SITU. MAT- CRCA. DIMENTION- 1X1.5 FEET
SUPPLY AND INSTALLATION OF OVERHEAD MIXING SHOWERS (20 NO.s) AND BULKHEAD TAPS (20 NO.s) MAKE: JAGUAR.
SUPPLY AND INSTALLATION OF TABLE/RACKS IN SURVEY OPS ROOM TO BE REPLACED WITH CRCA TABLES IN SITU. MAT- CRCA,AS PER DIMENSION. DIMENTION- 1X1.5 MTR
ELECTROPLATING OF SHIP'S BELL- 01 , CEREMONIAL STANCHIONS-06, CHAINS-01 NO., LENGTH -5 MTR AND VARIOUS TANNED FITTINGS, TO BE CARRIED OUT.
BENCH AND SOFA CUSHION WITH REXINE COVER TORN/ DAMAGED AT VARIOUS MESSES INCLUDING WARDROOM. TO BE RENEWED AS PER DIMENSIONS.MAT-WOOD(12) AND CRCA, REXIN
QUARTER MASTER TABLES, STATE BOARDS,ROSTRUM/PODIUM (02), LIFEBUOY STAND DAMAGED/ DETERIORATED. CEREMONIAL DICE TO BE MANUFACTURED AS PER EXISTING DIMENSION. (02 EACH), MAT- WOOD, DIMENSION - 1.5 X 1
EXISTING CANVAS COVERS FOR VARIOUS DECK MACHINERY AND FITTINGS DAMAGED. TO BE MANUFACTURED NEW AS PER SAMPLE FOR THE LIST BELOW:- (A) 7 m RHIB COVERS - 02 (B) SMB COVERS - 06 (C) SMB DAVIT MOTOR AND GEAR BOX - 06 (220X190X150 CM) (D) ANCHOR WINDLASS COVERS - 02 (E) CDT WINCH COVER - 02 (F) HMG COVERS - 02 (G) MMG COVERS - 03 (H) LMG COVERS - 05 (J) ROPE REEL COVERS - 07 (K) TUG SCREEN COVER 8X8 M - 04 (L) HELODECK HATCH - 02 (M) PNEUMATIC FENDER COVERS - 06 (N) 40/60 GUN COVERS - 02 (P) DECK CRANE CONTROL PANEL COVERS- 02 (Q) DIESEL DRIVEN PP COVER - 03 (R) SEAMANSHIP GEARS - 18 (S) BOAT BAGS - 04 (T) AWNING OF HELO DECK, BRIDGE WING (PORT AND STBD). (U) BRIDGE WING ( P & S) (V) CAPTAIN DECK (P&S) "
SUPPLY OF CEREMONIAL DAIS AND ITS COVER, INFORMATION BOARDS AND NBCD STATE BOARD CABINET DAMAGED. TO BE RENEWED. MAT- WOOD/SUNMICA, DIMENSION - 1.5 X 1 APPROX.
"FOLLOWING METALLIC SS/ BRASS/ ACRYLIC TALLY DAMAGED. TO BE RENEWED AS PER DIMENSION/ SAMPLE. (A) COMPARTMENT TALLEYS (HOSPITAL SHIP DUAL WHEREVER RELEVANT) - 96 NO.s (ACRYLIC) (B) COMPARTMENT BELOW TALLY- 40 NO.s (SS) (C) FRAME STATION TALLY - 134 NO.s (SS) (D) SHIP NAME TALLY (CAPTAIN DECK EITHER SIDE) - 02 NO.s (SETS) (E) MAN HOLE TALLY FOR TANKS- 35 NO.s (BRASS) (F) EQUIPMENT TALLEY- 50 NOS "
SUPPLY AND INSTALLATION OF DRAWERS IN WT OFFICE AS PER DIMENSIONS. QTY-06, MAT-CRCA/ WOOD. DIMENTION - 1.2X 0.6 MTR
FILE RACK DOOR DAMAGED IN WT OFFICE, TO BE RENEWED. QTY-06, MAT- SS/ CRCA. DIMENTION- 1.8X1 MTR EACH
SUPPLY AND INSTALLAION OF PANELLING OF TWO SCULLERY, CAPTAIN'S PANTRY, OFFICER'S PANTRY AS PER SIZE. WORK INCLUDE FITMENT OF SINGLE SKIN PANELS ALONG WITH SECURING ARRANGEMENT AND DADOE RECASTING-25 SQM MAT- SS
SUPPLY AND INSTALLATION OF WC SEAT COVERS AT JSWC, SSWC AND OFFICER'S WC.MAT- PVC. DIMENSIONS- 38X45 CM
SUPPLY AND FITTMENT OF SS PANELS IN WET COMPARTMENTS IAW NC/POLICY /H-121/Equipment DATED 05 Apr 17.
SUPPLY AND FITTMENT OF SOFA SET OF HULL OFFICE DIMENSION - 8*1 MTR, MAT- CUSHION WITH COVER AND CRCA LOCKERS UNDERNEATH.
SUPPLY AND FITTMENT OF BUNKS WITH SHOE LOCKERS (SIX), CUPBOARDS (TEN) IN 51 MEN MESS. JOB INVOLVES MANUFACTURING OF LOCKERS, BUNKS AND FITMENT . MATERIAL CRCA FOR BUNKS AND SS FOR LOCKERS.
FOLLOWING MODIFICATIONS TO BE CARRIED OUT AT DIVING STORE, SHIPS CANTEEN AND ND STORE IN VIEW OF ACCOMMODATING WOMAN AGNIVEER (a) SUPPLY AND FITMENT OF NEW FILE LOCKER (05 NOS). (b) SUPPLY ANDFITMENT OF NEW CRCA COMPUTER TABLE (3 NOS). (c) SUPPLY ANDFITMENT OF SAFE LOCKER (01 NOS) (d) SUPPLY AND FITMENT OF TWO TIER BUNKS (01 SET) AT REGULATING MESS. (e) SUPPLY AND FITMENT OF VENTILATION TRUNKING FOR AIR BALANCING (4 RMT).
FOLLOWING MODIFICATION TO BE CARRIED OUT IN SHIPS OFFICE AND REGULATING OFFICE FOR ACCOMMODATING WOMAN ANGNIVEER. MATERIAL TO BE PROVIDED BY YARD. (j) SUPPLY AND INSTALLATION OF 10 NEW BUNKS WITH SHOE LOCKERS (05 SETS). (a) SUPPLY AND INSTALLATION OF 12 NEW CUPBOARDS. (b)SUPPLY AND INSTALLATION OF SOFA CUM SHOE LOCKER (QTY-01). (c) SUPPLY AND FITMENT OF NEW CRCA TABLE (01 NOS). (d)SUPPLY AND INSTALLATION OF NEW GEYSER (QTY - 01) AND HOT WATER PIPELINES. (e) LAYOUT, SUPPLY AND INSTALLATION OF NEW 02 NOS WC COMMODE INCLUDES ALL HABITABLE FITTINGS WHICH INVOLVES PIPELINES CONNECTION TO COMPARTMENTS BELOW TO CONNECT TO STP SYSTEM. (f) LAYOUT , SUPPLY, INSTALLATION OF NEW 01 NO BATHROOM INCLUDING ALL HABITABLE ITEMS FITTED. (g) LAYOUT, SUPPLY AND INSTALLATION OF NEW WASHBASIN (QTY-01). (h) FABRICATION AND INSTALLATION OF DECK, BULKHEAD AND SHIPSIDE PENETRATION. (l) SUPPLY AND INSTALLATION OF NEW SS PANELING IN NEWLY INSTALLED WCS AND BATHROOM. (j) SUPPLY AND INSTALLATION OF NEW 03 NOS DECK DRAINS. (k) SUPPLY AND INSTALLATION OF ALL HABITABLE ELECTRICAL FITTINGS.
SUPPLY AND FITMENT OF MODULAR SOFA (2) SIZE 2MTR* 1MTR-QTY 02 FOR STORAGE OF LOG BOOK(02) SIZE 2MTR* 0.5MTR-QTY 02 AND MANUAL(02) SIZE 1 MTR* 0.5MTR-QTY 02 IN MCR. SIZE 2MTR* 1MTR-QTY 02 AND
FABRICATION AND FITTMENT OF FRP BOXES AS PER MEASUREMENT IS REQUIRED. WORK INCLUDES TAKING MEASUREMENT OF STOWAGE SPACES FOR FABRICATION OF THE BOXES.
REMOVAL OF DEFECTIVE BUNK LIGHTS AND FITMENT OF NEW MILITARY GRADE BUNK LIGHTS(230V AC). WORK INVOLVES REMOVAL OF OLD PANELS AND FITMENT OF PANELS.
THE CABLE OF HORIZONTAL BAR LIGHT IS PERISHED DUE TO FAIR WEAR AND TEAR. RECABLING AND REMOVAL OF OLD CABLE IS REQUIRED. (02 CORE, 2.5 SQMM)
HORIZONTAL BAR LIGHT PLATFORM DAMAGED DUE TO CORROSION. FABRICATION AND FITMENT OF NEW HORIZONTAL BAR LIGHT PLATFORM IS REQUIRED. (DIMENSIONS 7MTR X 6 INCH, MATERIAL SS)
SUPPLY AND INSTALLATION 20 IN NO.s HANGERS LENGTH - 0.8 MTR, AS PER SAMPLE.
FITTMENT OF BRACKETS FOR CABLE TRAY, LIGHTS, EQUIPMENTS AND ADDITIONAL FITTINGS POST REMOVAL OF PANELING FROM COMPARTMENTS AND FAT INSULATION ON ALL EXPOSED AREA IAW NCD 1430 ISSUE 1. MATERIEL TO BE PROVIDED BY YARD
REMOVAL OF EXISTING WOODEN FURNITURE AND FITTINGS AND REPLACEMENT WITH CRCA FURNITURE/ FITTINGS I.A.W. IHQ MOD LETTER NC/POLICY/H-121/EQUIPMENT DATED 05 APR 17 IN 52 COMPARTMENTS. WORK INVOLES DEGUTTING AND REGUTTING OF FITTINGS/ BRACKETS. QTY- 82 NOS
INSPECT ALL MODULAR ACCOMMODATION FITTINGS LIKE BUNKS, LOCKERS, CABINETS, KIT LOCKERS ETC FITTED IN MESS DECKS, CABINS AND OFFICES FOR ANY DEFECTS AND DAMAGES INCLUDING THEIR LOCKING SYSTEMS. YARD TO UNDERTAKE DEFECT RECTIFICATION FOR THE SAME. BUNKS- 184 LOCKERS - 180 CABINETS- 10 KIT LOCKERS - 184
SUPPLY AND INSTALLATION 30 IN NO.s HOOKS- 5 INCHES AS PER SAMPLE.
SUPPLY AND INSTALLATION 20 IN NO.s SHOP TRAY- 1 FEET AS PER SAMPLE.
SUPPLY AND INSTALLATION 20 IN NO.s HAND BAR- 0.5 MTR EACH AS PER SAMPLE.
SUPPLY AND INSTALLATION 30 IN NO.sTOWEL HANGER - 0.5 MTR EACH, AS PER SAMPLE.
visakhatrades (BID ID -416441)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Restricted Tender
This is a Open Limited tender. Documents are accessible only to bidders authorized by the issuing authority on the government portal.
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .