| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.4 CrAccepted-AOC | ₹1.4 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹1.4 Cr+₹85,906.32 (0.62%)Rejected-AOC | ₹1.4 Cr+₹85,906.32 (0.62%) | 2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹2.8 L
Closing Date
19 Sept 2022, 5:00 pmClosed
Executive Engineer
Executive Engineer, Uttarakhand Jal Sansthan Haldwani Rural (Lalkuan) situated at Goraparao Bareilly Road Haldwani District Nainital
Construction, Testing and Commissioning of Fattabangar-Himmatpur Motahaldu (MVS) Water Supply Scheme at Haldwani Block District Nainital
2022_UKJS_48675_13
909/E-Nivida/32 Dated 24.08.2022
Open Tender
Civil Works - Water Works
Item Wise
365 days
Haldwani Rural- Lalkaun
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
Executive Engineer, UJS
₹2.8 L
Haldwani Rural- Lalkaun
7 Oct 2023
1 Sept 2022
21 Sept 2022
1 Sept 2022
19 Sept 2022
1 Sept 2022
5 Sept 2022
Rates for Construction, Testing & Commissioning of Fattabangar-Himmatpur Motahaldu (MVS) Water Supply Scheme with Pumping Plant, Rising main, Distribution Main & Distribution Pipe Line, FHTC, Boundary Wall, Pump House Repair & Other works etc. at Haldwani Block District Nainital.
Pump & Related Electrical Item
Supply, Installation, Testing & Commissioning on turnkey basis for fully automatic pump automation control pannel of 1200 Lpm of 120 mtr. head capaciy having intelegent unit having" FIELD PROGRAMMABLE LOGIC CONTROLER based SCADA operated pump motor startRun Control Protactagainst faults automatically operated controle and management system" for supervisory control and data acquasition system at pumping water supply schemes & two year freeof cost AMC for warranty period of following dutiesas per specifications sheet enclosed &suaitable for integrationsin the existing system including cartage from works of manufactures up to site of work Capacity of 40HP.
Supply Installation testing and commissioning of three phase Electronic Automatic Voltage Stabiliser suitable for unbalanced voltage and unbalance load including fixing of proper size copper lugs on input and out put cables on both ends at different sites on turnkey basis including five year cost free maintenance. Input voltage 330V‐460V / 240 V(Two phase) Servo Voltage stabilizers ( 40 KVA)
Supply of Energy Submersible Pumpsets of various duty parameters, 400Lpm of 110 mtr. Head.
Supply and fixing of 400 Amp TPN main switch 3 phase, 415 volt, 50 H havells make heavy duty double break main switch with HRC fuse making connection at this testing complete work etc at dewalatallatubewell.
Supply and fixing of 35 KVAR heavy duty power capacitor L & T make 440 volt 50 H box type as per directed by Engineer-in-Charge.
Supply of 3 Core Flat Submersible Cable: KSB make Conti Cable 3/35.0 sq.mm suitable for Submersible as per directed by Engineer-in-Charge.
Main piping and valves as per specification.
Supply and fixing of suitable 16 mm thick MS Flange for column pipe both end with fixing trangle support and cutting of groove for cable all complete with labour & T&P
Supply of 150mm dia size column pipe clamps.
Supply of Tool Kits as per directed by Engineer-in-Charge.
Supply Lifting tackle 10 tonne capacity Chain pulley as per directed by Engineer-in-Charge.
Installation as per directed by Engineer-in-Charge.
STR Pumping & Accessories of Tubewell.
Supply, Installation, Testing & Commissioning on turnkey basis for fully automatic pump automation control pannel of 1200 Lpm of 120 mtr. head capaciy having intelegent unit having" FIELD PROGRAMMABLE LOGIC CONTROLER based SCADA operated pump motor startRun Control Protactagainst faults automatically operated controle and management system" for supervisory control and data acquasition system at pumping water supply schemes & two year freeof cost AMC for warranty period of following dutiesas per specifications sheet enclosed &suaitable for integrationsin the existing system including cartage from works of manufactures up to site of work Capacity of 90HP.
Supply Installation testing and commissioning of three phase Electronic Automatic Voltage Stabiliser suitable for unbalanced voltage and unbalance load including fixing of proper size copper lugs on input and out put cables on both ends at different sites on turnkey basis including five year cost free maintenance. Input voltage 330V‐460V / 240 V(Two phase) Servo Voltage stabilizers ( 100 KVA)
Supply of Energy Submersible Pumpsets of various duty parameters, 1000 Lpm of 110 mtr. Head.
INJECTING DOSER
Supply, Installation, Testing and Commissioning of Microprocessor based chemical dosing system suitable for providing automatically variable controlled dose of chemical to maintain required PPM of chemical with required accessories and 200 litres tank, wall mounting suitable for delivery up to 8 litters of chemical solution /sodium Hypo chloride solution per hours under maximum delivery pressure up to 10 kg/cm2 and Suction lift not less than 1.5 meter with accessories (i.e. Valve, Nozzle,200 litres PVC Tank etc complete)
Pump House A: -Repair Work :-
Providing and laying in position cement concrete of 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) grade - All work up to plinth level
Providing and laying in position 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) grade of Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. - for Thermo-Mechanically Treated bars
Centering and shuttering including strutting,ropping etc. and removal of form Slab, Chhajja
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand).
12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand).
Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) grade. - Apron
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. - New work (Two or more coat )
Finishing walls with exterior paint of required shade - New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
62 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening compound is mixed @ 2 litre per 50 kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and fixing to existing door frames - 24 mm thick factory made PVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitered and joined at the corners by means of M.S. galvanized/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanized M.S. tube of size 20x20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail made up of ’H’ section, a UPVC hollow section of size 100x24 mm and 2 mm ± 0.2 mm wall thickness fixed to the shutter styles by means of plastic/galvanized M.S. ‘U’ cleats. The shutter frame filled with a UPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm ± 0.1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanized M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. - Using M.S. angels 40x40x6 mm for diagonal braces.
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. for window, ventilator and similar works. use angle, square bar, etc
Providing & fixing glass panes with putty and glazing clips in steel windows & ventilator all complete. With 4.0 mm thick glass panes.
Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. - ISMB 300 x 140
Painting Steel work(doors, windows, etc.) with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture.
B:- Water supply & sanitary installations :-
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. for external works. 25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. for internal works. 20 mm dia nominal bore
Providing and fixing brass bib cock of approved quality. 15 mm nominal bore
20 mm nominal bore
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet. 150 mm diameter
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank
Excavation of earth below G.L. by manually or by mechanical means for laying of Sewers, Manholes, Gully pits, Chambers etc. in soil including extra excavation below inverts, trimming and dressing of sides, leveling and back filling of trenches by excavated earth in 20cm layers, watering and ramming the same including removal of surplus earth or other dismantled material upto a distance of 50 meters from the centre of trenches and cleaning of sites properly after completion of the work. Excavation by mechanical means shall be restricted upto 90 cm above invert levels at every point of excavation. Excavation from invert levels to 90cm above shall be done manually only. Soil mixed with moorum, shingle &kankar etc. using of any specials, T&P, if required. (95% of relevant quantity) 0.00m to 1.50m B.G.L.
Supply & Laying-Jointing of following dia R.C.C. S&S pipes with rubber gaskets to the site of work, lowering the same into trenches below ground level true to alignment, making the joints with rubber gaskets and with necessary spun yarn soaked in bitumen jointing with 1:2 cement mortar in coarse sand including cost of all jointing materials and testing etc. complete but excluding excavation and back filling of trenches upto ground level. (Class - NP3) 150mm dia 0.00m to 1.50m B.G.L.
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
100 KL tank situated Fattabangar.
Cleaner for Clean & Condition of OHT
High Voltage epoxy to Arrest Leakages
Labour Charge fixing of above Material.
BOUNDARY WALL (80m length)
Earth work in excavation by manual means in foundation trenches or drain (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of side and ramming of bottoms, lift upto 1.5 m including getting out the excavation soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Ordinary rock
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size)
Ist class Brick work 1:6 in foundation including necessary cutting and moulding as required and thickness of wall one brick. including supply of all materials, labour and T&P etc. required for proper completion of the work
Ist class Brick work 1:6 in super structure including necessary cutting and moulding as required and thickness of wall one brick. including supply of all materials, labour and T&P etc. required for proper completion of the work
PC plaster with cement mortar in 1:6 (one cement and six local sand) minimum thickness 12 mm including raking of joint upto 1.27 cm 10 1/2 '' depth and also including supply of all materials labour T&P and require for proper completion of the work
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Centering shuttering including struttings, propping etc. and removal of form work Lean Concrete
M.S. IRON GATE WITH PILLARS
Earth work in excavation by manual means in foundation trenches or drain (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of side and ramming of bottoms, lift upto 1.5 m including getting out the excavation soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Ordinary rock
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size)
Ist class Brick work 1:6 in foundation including necessary cutting and moulding as required and thickness of wall one brick. including supply of all materials, labour and T&P etc. required for proper completion of the work
Ist class Brick work 1:6 in super structure including necessary cutting and moulding as required and thickness of wall one brick. including supply of all materials, labour and T&P etc. required for proper completion of the work
PC plaster with cement mortar in 1:6 (one cement and six local sand) minimum thickness 12 mm including raking of joint upto 1.27 cm 10 1/2 '' depth and also including supply of all materials labour T&P and require for proper completion of the work
M.S. work in heavy size such as build up gates doors, frames etc wrought to required from including drilling of holes revanting of welding share necessary and also including supply of steel bolts, nuts etc and their fixing required for proper completion of work
Acrylic smooth exterior paints three coats on pillars
Painting two coats of approved paint over one base (priming coat) on new surface of Gate and Pillars
Centering shuttering including struttings, propping etc. and removal of form work For CC work
Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :Bituminous road
Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per directionof Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent designmix)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Excavation in soil mixed shingle boulders etc for pipe line trenches including lift 1.5 M and lead up to 30 M with backfilling , watering, ramming of excavated earth in the trenches
Providing of all materials ,carting from site store to site of work laying and jointing of G.I. Screwed-Medium Duty (Class "B") (Including supply of all jointing materials like specials, white lead hemp and oil etc.) in trenches with its cutting ,threading and testing of pipe line etc complete (external work) 50 mm dia
65 mm dia
80 mm dia
100 mm dia
125 mm dia
Providing & fixing C.I. D/F Sluice valves Confirming to IS: 14846-2000 in position etc complete - PN 1.6 C.I. Sluice Valves Pressure PN 1.6 50 mm dia
65 mm dia
80 mm dia
150 mm dia
Supplying and Fixing of Fire Hydrant Valve IS 5290 (Flanged) Including carting the same up to site of work and fixing the same and water supply line Including the cost of valves, specials, labour and T&P Complete in all respect. (Stand post type) 80 mm diameter
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
FIRE HYDRANT CHAMBVER
Providing & Fixing Woltman type Bulk Water Meter lnlinetype,flangee.nd with Integral mounted display and all necessary fillings etc complete. 150 mm
Making connection with the existing M.S. Galvanised mains of upto 25mm nominal dia, including cutting and threading of pipe, bailing out water, fixing, if required, specials and testing etc. complete, but excluding cost of insertion pipes and specials besides boring out (and also subsequent back fill) existing main.50mm-80mm
Repairing of 50 mm to 150 mm dia GI/MSERW pipe line by Welding. Work including : (i) Earth work in Excavation, (ii) Dewatering of pit manually and cleaning of pipe line as lumpsum @ 1/2 Lab for half day. (iii) Earth filling with ramming 10% extra of excavation. and (iv) Repairing of pipe by 01 welder and 02Helper( Labour). including Labour charge, Material and T&P complete all in respect.
Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etccomplete.G.I. PIPE CONFORMING TO IS : 1239(PART-1).Medium Duty (Class 'B'). 15 mm dia
Making ferrule connection in the existing main of G.I, A.C, PVC or any type of pressure mains with saddle piece, service connections, fittings and fixing of G.M. ferrule including tapping the main, but excluding the cost of earth work and cost of all materials. 19.01 Ferrule Connection (Labour cost only)/Connection Ferrule Connection (Labour cost only)
Cost of Material for ferruling in FHTC per connection as Lump Sum
Excavation in soil mixed shingle boulders etc for pipe line trenches including lift 1.5 M and lead up to 30 M with backfilling , watering, ramming of excavated earth in the trenches
M/S BAJPAI CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .