Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹2.9 L+₹4,914 (1.71%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹3.0 L+₹7,923 (2.76%)Rejected-Finance | L3 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
Closing Date
16 Mar 2021, 10:00 amClosed
Maj GS Pandey, GE (AF) Bhuj
GE (AF) Bhuj, Bhuj-Kutch, PIN-370001
Repair, maintenance and replacement of UG cables of Transmitter and Met Section in Tech area at AF Stn Bhuj
2021_MES_429192_1
3020/eQ/86/20-21/E3
Limited
Job Works
Item Rate
30 days
GE (AF) Bhuj
The firm must be registered with HQ CWE (AF) Bhuj as approved supplier to carryout general order supply and job work
1 document required · 1 mandatory
₹0
Exempted
17 Aug 2021
9 Mar 2021
17 Mar 2021
9 Mar 2021
16 Mar 2021
9 Mar 2021
Amount
1. Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil complete. (Cum 145.80) 2. Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick all as specified and as directed. (Cum 82.58) 3. Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points. (Cum 63.22) 4. Taking out LT cables from excavated trenches, ducts, wall, pole etc including removing cable covers, sand, cable joints, pipes, clamps etc,for the following size of cable :- LT cables of 240 sqmm, 3.5 core. (RM 250.00) 5. Taking out LT cables from excavated trenches, ducts, wall, pole etc including removing cable covers, sand, cable joints, pipes, clamps etc,for the following size of cable :- LT cables of 70 sqmm, 3.5 core. (RM 150.00) 6. Taking out LT cables from excavated trenches, ducts, wall, pole etc including removing cable covers, sand, cable joints, pipes, clamps etc,for the following size of cable :- LT cables of 150 sqmm, 3.5 core. (RM 220.00) 7. Taking out LT cables from excavated trenches, ducts, wall, pole etc including removing cable covers, sand, cable joints, pipes, clamps etc,for the following size of cable :- LT cables of 25 sqmm, 3.5 core. (RM 100.00) 8. Relaying,connecting, Megger testing, commissioning and jointing, LT underground cable 1100 volts grade in trenches,ducts,fixed on poles/walls with proper size saddles and clamp laid under roads /path /drain /culverts all as specified and as directed by the EIC of following Size:- LT cables of 240 sqmm, 3.5 core ) (RM 250) 9. Relaying,connecting, Megger testing, commissioning and jointing, LT underground cable 1100 volts grade in trenches,ducts,fixed on poles/walls with proper size saddles and clamp laid under roads /path /drain /culverts all as specified and as directed by the EIC of following Size:- LT cables of 70 sqmm, 3.5 core ) (RM 150)
10. Relaying,connecting, Megger testing, commissioning and jointing, LT underground cable 1100 volts grade in trenches, ducts, fixed on poles/walls with proper size saddles and clamp laid under roads /path /drain /culverts all as specified and as directed by the EIC of following Size:- LT cables of 150 sqmm, 3.5 core ) (RM 220) 11. Relaying,connecting, Megger testing, commissioning and jointing, LT underground cable 1100 volts grade in trenches,ducts, fixed on poles/walls with proper size saddles and clamp laid under roads /path /drain /culverts all as specified and as directed by the EIC of following Size:- LT cables of 25 sqmm, 3.5 core ) (RM 100) 12. M&L for straight through joint (epoxy) for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing of Cable size 240 Sqmm, 3.5 core. (Make :- M seal/3M /Denson) (Each 02) 13. M&L for straight through joint (epoxy) for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing of Cable size 70 to 150 Sqmm, 3.5 core. (Make :- M seal/3M /Denson) (Each 04) 14. M&L for straight through joint (epoxy) for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing of Cable size 25 Sqmm, 3.5 core. (Make :- M seal/3M /Denson) (Each 02) 15. Laying only retrieved sixty percent serviceable cable covers obtained while taking out U/G cable from srl item No.4 to 7 above. (Each 2046) 16. M & L unreinforced precast concrete cable covers CLASS LV type II, flat size 300 x 180 x 40 mm laid transverse to cable. (Each 1354) 17. M&L for sand cushioning for UG cables using dry river sand, gently punning down all as directed and specified. (Cum 52.49) 18. S&F GI tubing light grade for encasing cables for mechanical protection, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MS clamps with necessary bolts, nuts and washers all as specified of sizes : -50 MM bore. (RM 12.00) 19. Supply & Fix connecting,testing and commissioning and jointing,LT under ground cable 1100 volts grade,XLPE insulated,armoured with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in trenches,ducts,fixed on poles/walls with proper size saddles and clamp laid under roads /path /drain /culverts or encased in GI pipe fixed & testing and commissioning complete all as specified and as directed by the Engineer-in-Charge of following Sizes:- LT cables of 25 sqmm, 3.5 core (RM 40)
Ayush Electrical
Bhavik Construction
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_479153.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .