| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC WANIAWAD BHUJ KUTCH PIN 370 001 | KACHCHH | GUJARAT | 370001 | ₹41.9 L Quoted ₹42.3 L | L1 | Accepted-AOC LOWEST BID |
| 2 | L2₹44.9 LRejected-Finance | ₹44.9 L | L2 | Rejected-Finance HIGHER BID |
| Sl No | Description | Qty | Unit | M/s Bombay Novelty Stores L1 | Sudarsan Singh L2 |
|---|---|---|---|---|---|
| 1.00 | Demolition of concrete block masonry built in cement mortar or cement lime mortar complete all as specified and directed. | 20 | Cum | 460 ₹9,200 | 400 ₹8,000 |
| 2.00 | M&L for Pre-cast cement concrete block masonry (Type C1, 1:3:6, 20mm aggregate) with solid blocks, exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed. | 20 | Cum | 5,800 ₹1,16,000 | 5,500 ₹1,10,000 |
| 3.00 | Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed. | 1,350 | Sqm | 30 ₹40,500 | 20 ₹27,000 |
| 4.00 | M & L Cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement complete all as specified and directed.
Note : WPC will be measured and paid separately. | 1,350 | Sqm | 300 ₹4,05,000 | 265 ₹3,57,750 |
| 5.00 | Supply only integral liquid water proofing compound complete all as specified and directed.
Make : Pidilite/Sika | 75 | Ltrs | 45 ₹3,375 | 50 ₹3,750 |
| 6.00 | M&L for applying acrylic wall care putty on new/old plastered External surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed.
Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty.
Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE /Engineer-in-Charge. | 2,350 | sq.m | 100 ₹2,35,000 | 165 ₹3,87,750 |
| 7.00 | Complete removal of existing treatment of any type/description from walls/RCC surfaces/ceiling/chajjas/roof projections etc with mechanical means/grinder complete all as specified and directed. | 1,000 | sq.m | 15 ₹15,000 | 10 ₹10,000 |
| 8.00 | Preparation of surfaces and applying 02 coats of exterior emulsion paint (light shade) with highlighter of any approved shade, @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed.
Make of Exterior Wall Primer : Asian / Berger / Nerolac [Best Quality].
Make of Exterior Emulsion : Asian (APEX) / Berger (WEATHER COAT ANTI DUST) / Nerolac (EXCEL TOTAL) . | 3,050 | sq.m | 110 ₹3,35,500 | 100 ₹3,05,000 |
| 9.00 | M&L for plain cement concrete (1:2:4) type B-2, using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. | 15.36 | CUM | 5,700 ₹87,552 | 5,500 ₹84,480 |
| 10.00 | M&L, Pre Stressed, pre cast RCC ( M-25 Grade ) column of size 150mm X 150mm and 2.10 meter height with contineous vertical groove of sizes 60mmx35mm at two sides of column to receive the precast panels, including reinforced with 7 Nos wires of 3mm dia high tensile corbonized steel, surfaces finished even and smooth including errecting in position all as specified and as directed including dismentling of old pre stressed precast column/post complete. | 240 | Each | 840 ₹2,01,600 | 800 ₹1,92,000 |
Tender Value
₹43.1 L
EMD Value
₹86,120
Closing Date
10 Feb 2026, 6:00 pmClosed
GE ARMY
BHUJ
CERTAIN MISC B/R WORKS TO VARIOUS BLDGS UNDER AGE B/R-II AND COMPREHENSIVE REPAIR AND MAINTENANCE OF DG SETS, STP, SWIMMING POOL UNDER GE (A) BHUJ AT MIL STN BHUJ AND KHAVADA
2026_MES_747092_1
8377
Open Tender
Civil Works
180 days
BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE ARMY
₹86,120
14 Mar 2026
8 Jan 2026
12 Feb 2026
8 Jan 2026
10 Feb 2026
22 Jan 2026
Demolition of concrete block masonry built in cement mortar or cement lime mortar complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry (Type C1, 1:3:6, 20mm aggregate) with solid blocks, exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed.
Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed.
M & L Cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement complete all as specified and directed. Note : WPC will be measured and paid separately.
Supply only integral liquid water proofing compound complete all as specified and directed. Make : Pidilite/Sika
M&L for applying acrylic wall care putty on new/old plastered External surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed. Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE /Engineer-in-Charge.
Complete removal of existing treatment of any type/description from walls/RCC surfaces/ceiling/chajjas/roof projections etc with mechanical means/grinder complete all as specified and directed.
Preparation of surfaces and applying 02 coats of exterior emulsion paint (light shade) with highlighter of any approved shade, @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed. Make of Exterior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Exterior Emulsion : Asian (APEX) / Berger (WEATHER COAT ANTI DUST) / Nerolac (EXCEL TOTAL) .
M&L for plain cement concrete (1:2:4) type B-2, using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M&L, Pre Stressed, pre cast RCC ( M-25 Grade ) column of size 150mm X 150mm and 2.10 meter height with contineous vertical groove of sizes 60mmx35mm at two sides of column to receive the precast panels, including reinforced with 7 Nos wires of 3mm dia high tensile corbonized steel, surfaces finished even and smooth including errecting in position all as specified and as directed including dismentling of old pre stressed precast column/post complete.
M&L, Pre Stressed, pre cast RCC ( M-25 Grade ) panels of 1800mmx300mm size and 45mm thick, reinforced with 4 Nos wires of 3 mm dia high tensile corbonized steel, including fixing in position in between column grooves and jointing and flush pointing of all horizontal and verticle joints of panels with cement mortar 1:3 complete all as specified and as directed including dismentling of old pre stressed pre cat panel complete..
M&L for providing precast cement concrete louvres and jallies, 25mm thick (measured solid) type B0 1:2:4 using 12.5mm aggregate set in cement mortar 1:4, including all mouldings and demolition of old louvers and jallies complete all as specified and directed.
M&L for providing precast cement concrete type B1 1:2:4 (20 mm graded aggregate) in apex stone/kerb stone with plain fair faces including chamfers, weathering throating etc and set in CM 1:4 complete with joints, size and shape as approved complete all as specified and directed.
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate for filling of gap between road, kerbs stone and interlocking paver block with finished fair all as speificed and directed.
M&L for preparation of new concrete surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer all as specified and directed.
M&L for preparation of old painted concrete surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specially provided for as in surface channel.
Dismantling of AC/CGI Sheet of any size complete all as specified and directed by Engr-in-Charge
M&L for exterior grade, coloured, cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc. complete all as specified and directed.
M&L for 100 mm thick PCC 1:2:4 type B2, (using 40 mm graded stone aggregate) as in floors/paving finish even and smooth without using extra cement complete all as specified.
M&L for screed bed or bedding layer of mortar 20mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
M&L providing precast cement concrete rubber moulded coloured interlocking tiles with grey cement and pigment conforming to IS-15658-2006 of 80 mm thick (M-40 grade) of approved design and pattern complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in as in sub base all as specified and directed.
M&L for 60 mm thick paver blocks rubber moulded PCC M-35 with grey cement and pigment conforming to IS-15658-2006 of approved design and pattern complete all as specified and directed.
M&L for Sand filling under floors or in foundation incl watering and consolidation for laying interlocking tiles complete all as specified and directed.
Taking down and refixing of existing interlocking tiles any type and any shape fixing over 25 mm sand cusoning complete all as specified and directed. Note: after taking down existing tile will be completely cleaned before laying
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
Supply & fix rolled mild steel in joist, angle ,channel as in purlins, rafters cleats etc conforming to Fe-410- W (Gde-E-250) quality A complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws all as specified and as directed
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge / roof covering/ cladding to wall, fixed with self tapping screws all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
S&F Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc all as specified and as directed.
Comprehensive maintenance of 200 KVA DG sets for routine/preventive maintenance, checking up of Engine and Alternator for smooth functioning and attending breakdowns/ complaints as and when required for smooth functioning of DG Set. The type of work/maintenance services to be carried out during comprehensive maintenance are as unde complete all as specified and directed.r:- (a) Cleaning of air filter (b) Checking and adjusting of valve tappet clearance (c) Checking of Engine lubrication system, fuel system, air system, cooling system, mechanical adjustments/rectification and electrical system. (d) Changing of lube oil filter if necessary (e) Changing/cleaning of fuel pre & fine filter (f) Checking and tightening of bolts and nuts (g) Checking of flexible rubber coupling (h) Checking of charging system of the battery. (i) Checking of ‘V’ belt and adjusting the tension (j) Checking of exhaust turbo charger (k) Checking of fuel injector (l) Checking and cleaning of breather pipe (m) Checking of alternator terminals and cable lighteners etc (n) Checking of safety controls operation (o) Checking of speed governors and engine shut down for proper functioning. (p) Checking of proper functioning of self starter and provision and battery charging (q) Greasing of generator
All as per item No. 33 here-in-before but 160 KVA DG set
All as per item No. 33 here-in-before but 125 KVA DG set
All as per item No. 33 here-in-before but 100 KVA DG set
All as per item No. 33 here-in-before but 62.5/63/75 KVA DG Set
All as per item No. 33 here-in-before but 15/20 KVA DG Set
Supply only set of fuel pre-filters and fine filters as per sample and make of the following capacities of DG sets (fixing under srl item No 1) complete all as specified and directed. Note: Each set comprising of the complete pre/fine filters required at site (i) 200 KVA DG set
All as per item No. 39 here-in-before but 160 KVA DG set
All as per item No. 39 here-in-before but 125 KVA DG set
All as per item No. 39 here-in-before but 100 KVA DG set
All as per item No. 39 here-in-before but 62.5/63/75 KVA DG Set
All as per item No. 39 here-in-before but 15/20 KVA DG Set
Supply only set of lub/engine oil filters/cartridges as per sample and make, of the following capacities of DG sets (fixing under srl item No 1) complete all as specified and directed. (i) 200 KVA DG set
All as per item No. 45 here-in-before but 160 KVA DG set
All as per item No. 45 here-in-before but 125 KVA DG set
All as per item No. 45 here-in-before but 100 KVA DG set
All as per item No. 45 here-in-before but 62.5/63/75 KVA DG Set
All as per item No. 45 here-in-before but 15/20 KVA DG Set
Supply only flexible fuel pipes with bunjo bolts and nuts as per sample length and size to meet the requirement of site condition complete all as specified and directed.
Supply only fan belts for replacement of u/s fan belts of following capacities of DG set as per sample size complete all as specified and directed. Note: Fixing charges considered under srl item No 1 here-in-before (i) 200 KVA DG set
All as per item No. 52 here-in-before but 160 KVA DG set
All as per item No. 52 here-in-before but 125 KVA DG set
All as per item No. 52 here-in-before but 100 KVA DG set
All as per item No. 52 here-in-before but 62.5/63/75 KVA DG Set
All as per item No. 52 here-in-before but 15/20 KVA DG Set
Supply only ''ON DELAY TIMERS" (for stop/start/LOP/LOT/FAULT etc) Time range 3 sec to 30 hours, contact 5 Amps, 240V/12-24 volts, DC, complete all as specified and directed
Supply only Auxillary/control contactors (2 NO, 2 NC) of suitable ratings for AMF panels complete all as specified and directed
Supply only battery charger flot cum boost charger ie step down transformer) for ratings 15A 220-240V/12-14-16 Volts and suitable for AMF panels complete all as specified and directed
Supply only battery charger flot cum boost charger ie step down transformer) for ratings 10A 415V/0-24 Volts and suitable for AMF panels complete all as specified and directed
Supply only single phase preventor model VSP3, 415 volts AC 50 hz suitable for AMF panel complete all as specified and directed
Supply only lead acid battery 12 V 180 AH, complete all as specified and directed.
Supply only lead acid battery 12 V 150 AH, complete all as specified and directed,
Supply only lead acid battery 12 V 135 AH, complete all as specified and directed,
Supply only lead acid battery 12 V 70 AH, complete all as specified and directed.
Supply only oil sensor upto 200 KVA DG set complete all as specified and directed.
Material and labour for repair of door of DG set canpoy using new hinges, welding work etc upto 200 KVA DG set complete all as specified and directed.
M & L for repair fuel feed pump upto 200 KVA DG set, replacement of components required to make functiona complete all as specified and directed.
Material and labour for radiator anticorrosive coolent conditioner properly mixed up with the radiator water complete all as specified and directed.
Material and labour for lubricant oil for diesel generating set of any capacity and any make complete all as specified and directed.
Supply and fixing solenoid switch 12V as per sample of following capacities of D G sets: (i) 200 KVA DG set -01 Nos complete all as specified and directed.
All as per item No. 72 here-in-before but 160 KVA DG set
All as per item No. 72 here-in-before but 125 KVA DG set
All as per item No. 72 here-in-before but 100 KVA DG set
All as per item No. 72 here-in-before but 62.5/63/75 KVA DG Set
All as per item No. 72 here-in-before but 15/20 KVA DG Set
Supply and replacement of AVR for 62/62.5/75 KVA DG set as per sample including control wiring complete all as specified and directed.
Supply and replacement of AVR for 100 to 160 KVA DG set as per sample including control wiring complete all as specified and directed.
Supply and replacement of AVR for 200 KVA DG set as per sample including control wiring complete all as specified and directed.
M & L for replacement of unservicable self starter motor sutable for 62/62.5/75KVA DG set of suitable DC volatge 12/24V including control wiring from control panel and battery all as specfied and directed.
M & L for replacement of unservicable self starter motor sutable for 200 KVA DG set of suitable DC volatge 12/24V including control wiring from control panel and battery all as specfied and directed.
Replacement of unservicable self starter motor sutable for 200KVA DG set of suitable DC volatge 12/24V including control wiring from control panel and battery all as specfied and directed.
Supply and replacement PVC insulated battery lead of suitsble size with copper conductor cable of length 1.5 mtr with copper/brass clamps and lugs for fixing on battery terminals and self starter complete as specified and as directed.
Replacement of unservicable microprocesser based control logic board matching and other related parts to existing control panel of 75KVA volatge stablizer for smooth working of stablizer complete all as specified and directed.e all as specified and directed.
supply and fix suitable 4 pole contactor with NO NC auxillary contact suitable for 15KVA DG set including testing complete all as specified and directed.
supply and fix suitable 4 pole contactor with NO NC auxillary contact suitable for 20KVA DG set including testing complete all as specified and directed.
supply and fix suitable 4 pole contactor with NO NC auxillary contact suitable for 62.5KVA DG set including testing complete all as specified and directed.
supply and fix suitable 4 pole contactor with NO NC auxillary contact suitable for 75KVA DG set including testing complete all as specified and directed.
supply and fix suitable 4 pole contactor with NO NC auxillary contact suitable for 100KVA DG set including testing complete all as specified and directed.
supply and fix suitable 4 pole MCCB 160A ,415V ,36KA adjustable overload settings : 0.8-1.0x In adjustable short cicuit settings 6-10 x including make tight nut bolt connection, testing complete all as specified and directed.
supply and fix suitable 4 pole MCCB 200A ,415V ,36KA adjustable overload settings : 0.8-1.0x In adjustable short cicuit settings 6-10 x including make tight nut bolt connection, testing complete all as specified and directed.
supply and fix suitable 4 pole MCCB 250A ,415V ,36KA adjustable overload settings : 0.8-1.0x In adjustable short cicuit settings 6-10 x including make tight nut bolt connection, testing complete all as specified and directed.
Cleaning of various tank like inlet chamber , bar screen chamber, grit chamber ,equilization tank,MB reactor-1,MB Reactor-2 ,Lamller flow chamber ,Filter Feed tank,Treated water tank of RCC made, removing blockage of stariner inlet, pump outlet, all pipe of various size installed in STP of 0.15 MLD capcity sewage treatment plant by dewatering the existing soil, slit, sludge by using pneumatic pump adhering proper precautions and safety measures,cleaning the entire surface of bottom and side walls by washing with a pressure nozzle to remove entire dirt etc complete all as specified and directed.
Supply & Fill Alum Non ferric (crystal) complete all as specified and directed. Note :- Test certificate shall be produced along with the material.
Supply & Fill Bleaching powder Grade -I ISI Mark,Make:Shri Ram complete all as specified and directed. Note :- Test certificate shall be produced along with the material.
Supply & Mixing caustic soda (NaoH) complete all as specified and directed. Note :- Test certificate shall be produced along with the material.
Testing of treated water of STP from NABL recoginised lab as existing indian standards and submitt report monthly to Enginner-in-charge complete all as specified and directed. Note:Penality of 1000 per month if report not submitted monthly.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1:3:6) type C-1 for earth pit and 40mm thick pre cast RCC cover in 1:2:4 type B1 with 3 Nos 8mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: (i) Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ (ii) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6 type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforsed, funnel with watering pipe.
M&L for chemical earthing with copper earth plate 600mm X 600mm X 6mm buried directly in ground (earth pit not less that 12' deep below ground level) connected to copper earth strip 32x6mm by means of copper brazing after tighten by bolts bolts, nuts, check nuts and washers of brass from earth pit to test point with protection GI pipe of size 40mm dia light including wiremess steel funnel complete with alternate layer of salt crystal (200 Kgs), charcol (250 Kgs), magnesium sulphate crystal (100 Kgs) in each earth pit, including watering arrangement 200 ltr for each earth pit complete all as specified and directed. NOTE: Copper strip 7.5 mtr included in the quoted rate from earth pit to test point.
Supply and fix earth continuity conductor or main earthing lead fix to wall on batten or recess or chase or burried in ground or drawn in conduit/ pipe or ffixed to poles or any other indicated situation for loop earthing etc. as required of size 32 mmx 6mm aluminum strip complete all as specified and directed.
Supply and fix earth continuity conductor or main earthing lead fix to wall on batten or recess or chase or burried in ground or drawn in conduit/ pipe or ffixed to poles or any other indicated situation for loop earthing etc. as required of size 32 mmx 6mm copper strip complete all as specified and directed.
Opening of top and bottom cover of horizontal type pressure feed filteration plant of capacity 30000 glns/ hr at swimming pool taking out old filter media and strainer etc depositing to a distance not exceedings 50 mtrs complete all as specified and directed.
Material and labour for scrapping and cleaning the surface bed inner and outer surface of the shell for complete removal of scales, rust old paint etc and painting with two coats of anti corrosive bituminus paint suitable for storage of potable water for internal / external surfaces two coats of synthetic enamel paint of approved colour for horizontal type pressure feed filteration plant of capacity 30000 glns complete all as specified and directed.
M & L swimming pool floor diffuser size and shape as per existing, heavy duty, white colour complete all as specified and directed.
M & L swimming pool net, foldable 66 inch telescopic landing net with aluminium alloy handle, robust and durable complete all as specified and directed.
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TENDER8377.pdf
Tender Documents • 0.54 MB
LISTOFMAKE.pdf
Tender Documents • 0.20 MB
PS8377.pdf
Tender Documents • 0.87 MB
BOQ_836599.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid