Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC FLAT NO 304 SN TOWERS JAGANNADHAPURAM JUNCTION AKKAYYAPALEM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.7 L+₹3.6 L (9.92%)Rejected-Finance | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹43.2 L+₹7.0 L (19.4%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹43.4 L+₹7.2 L (20.0%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L4 | Rejected-Finance Being Not L1 | |
| 5 | L5₹44.1 L+₹8.0 L (22.1%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L5 | Rejected-Finance Being Not L1 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
28 Dec 2019, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
SPECIAL REPAIRS FOR REPLACEMENT OF OLD HT FOUR POLE STRUCTURE WITH RMU UG CABLE AND CONNECTED WORKS AT SAMUDRIKA AREA AND PROVN OF ADDITIONAL STREET LIGHTS FROM SATVANAHA TO DOCKYARD ON EXISTING POLE AT DEFENCE ROAD UNDER AGE EM I OF GE UTILITY I
2019_MES_304791_1
8971/E8
Open Tender
Electrical Maintenance Service
Item Rate
150 days
Garrison Engineer Utility-I Visakhapatnam
CLASS D
10 documents required · 10 mandatory
₹500
Garrison Engineer Utility-I
₹99,000
Yes
9 May 2020
7 Dec 2019
30 Dec 2019
7 Dec 2019
28 Dec 2019
22 Dec 2019
Amount
M&L for carefully dismantling existing four pole structure complete including removal of steel poles along with foundation, cross arms etc and segregate the steel poles for re-erraction at another site as directed by the Engr-in-Charge
Supply, installation, testing & commissioning of 11 KV, 630A, 21kA/3sec, Outdoor type, both sides extensible, Internal arc 21kA for 1 Sec for Tank, floor mounted with internal copper bus bars, SF6 Insulated, completely Motorised, 6 Way RMU consisting of 2 Nos LBS as Incomer & 4 Nos 630A VCBs as Outgoing with SACADA compatable Overload and eart fault protection Relay (Ashidha / CSPDR) with air insulated Metering module (MFM for VCB Feeders). All live parts, bus bars, LBSs connections of RMU shall be enclosed in one SF6 tank to avoid multiple interconnections. SF6 Tank shall be sealed for life robotically welded non magnetic and non ferrite stainless steel Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200.
Manual welding or hermetic sealing of tank shall be not be accepted. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards. Altitude of installation up to 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external bus bar. Also, the outer enclosure shall cover the full length of the switchgear,to ensure IP3X+IP54 protection for cable boxes. The unit shall be internal arc proof 21kA for 1 se with AFLR clasification.,tested and totally safe for human beings. The gas release & personnel safety from internal arc shall not depend on plinth design. The release of gas to be from the top of the unit, so that, even if the person is operating the unit, opening the cover, & there are personnels near the sides of the RMU/plinth, top release will ensure their safety. The hot gas release, in case of an internal arc, in no case should be from any side or bottom of the unit, as the same is unsafe for the operating personnel/pedestrian or general public. Bidder shall provide type test report to prove compliance to the Internal Arc fault IAC-AFLR as per IEC 62271-200. Internal arc testing shall be done with enclosure door in open condition, with switching devices in operation mode as per specified standard. complete all as directed of make : BHEL / ABB / SCHNEDIER / SIEMENS / ANDREW YULE.
Supply, installation, testing & commissioning of 11 KV, 630A, 21kA/3sec, Outdoor type, both sides extensible, Internal arc 21kA for 1 Sec for Tank, floor mounted with internal copper bus bars, SF6 Insulated, completely Motorised, 6 Way RMU consisting of 2 Nos LBS as Incomer & 3 Nos 630A VCBs as Outgoing with SACADA compatable Overload and eart fault protection Relay (Ashidha / CSPDR) with air insulated Metering module (MFM for VCB Feeders). All live parts, bus bars, LBSs connections of RMU shall be enclosed in one SF6 tank to avoid multiple interconnections. SF6 Tank shall be sealed for life robotically welded non magnetic and non ferrite stainless steel Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. Manual welding or hermetic sealing of tank shall be not be accepted. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards. Altitude of installation up to 1000m as per IEC 60120.
Bushings bolted type top mounted outside the tank for connection of external bus bar. Also, the outer enclosure shall cover the full length of the switchgear,to ensure IP3X+IP54 protection for cable boxes. The unit shall be internal arc proof 21kA for 1 se with AFLR clasification.,tested and totally safe for human beings. The gas release & personnel safety from internal arc shall not depend on plinth design. The release of gas to be from the top of the unit, so that, even if the person is operating the unit, opening the cover, & there are personnels near the sides of the RMU/plinth, top release will ensure their safety. The hot gas release, in case of an internal arc, in no case should be from any side or bottom of the unit, as the same is unsafe for the operating personnel/pedestrian or general public. Bidder shall provide type test report to prove compliance to the Internal Arc fault IAC-AFLR as per IEC 62271-200. Internal arc testing shall be done with enclosure door in open condition, with switching devices in operation mode as per specified standard. complete all as directed of make : BHEL / ABB / SCHNEDIER / SIEMENS / ANDREW YULE.
Supply and laying or fixing or passing through pipe or in cable ducts, 11000 volts grade XLPE insulated Heavy duty (earthed),screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 185 sq mm 3 core size including dismantling old one. Make : Polycab/Havells/Finolex/Gloster Cable.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm. Make: Birla 3M/ Raychem/ Denson
Supply and fix cable jointing kit for 11 KV grade cable for indoor terimination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conducter cable of size 185 sq mm. Make: Birla 3M/ Raychem/ Denson
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation, trenches for laying cables/ pipe line etc. and getting out in soft/loose soil
Removing excavated materials to a distance n. exc. 50m and depositing where directed at a level n. exc 1.50m above the starting point.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil.
Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed. (Note: Punned thickness only shall be measured)
Cutting & Cleaning of bushes/small plants, at sub stn incl surface dressing and removing debris to distance not exc 50 mtr complete
Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as directed
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as directed
S&F MS angles, bars flats etc, as in supports for stiffening of fencing, wall ties, hold fasts, clamps and similar small articles confirming to Fe 410-0 or Fe 310-0 complete
Supply and laying un-reinforced pre cast cover of size (300mmx180mmx40mm) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Supply and fix or laid in road crossing/ fixed to poles, GI Pipe of 150 MM size light grade for protection of cable complete all as directed
M &L Plain cement concrete 1:4:8 type C2 (using 40 mm aggregrate) as in foundations filling mass concrete complete all as specified and directed
M &L for cement concrete PCC 1:2:4 type B1 (using 20 mm aggregrate) as coping of poles complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machinery including GI pipe 150 mm bore, light grade for drawing of cable complete all as directed.
Cutting trench through road/ wall to a width of 20cm and depth of 30cm for inserting GI protection pipe for drawing cable and filling back the trench with PCC 1:3:6 type C1 complete all as directed.
M&L for Earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.5 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing)
Supply& fix aluminium strip 32 mmx 6 mm coplete wiyh saddles and fixing screws for fitting the strip
Supply & Fixed in repairs street light luminaire integral type LED fitting of 90 watts output with minimum 60 lumens per watt in aluminium die cast housing with IP 66 protection complete with all accessories incl driver and electronic surge protection device of min 5 KV complete all as specified. (Make: Philips, Cat No.BRP410 LED 091 CW HE MR PC S2 PSU GR ) with following items. (a) FRP Loop In Loop Out Boxes compatible to fix MCB with mounting rails,cable connector inclusive provn of suitable GI clamps for fixing to poleand and size of cable 50/70 Sqmm 3.5 core , PVC glands of Hensel model K004 or equivalent in Sintex / Hensal complete all as directed -34 Nos (b) PVC insulated PVC sheathed cable galvanised steel strip or wire armoured electric control cables ( heavy duty) with stranded copper conductor of size 3 core 2.5 Sqmm -310 Rm (c)bracket for street light fitting made out of 50 mm bore pipe light grade GI tube bent to shape required, fixed with and including MS flat iron clamps -02 Nos, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete including taking out old one as specefied and directed.-34 Nos
Supply and laying and testing XLPE insulated screened PVC bedded galavanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with aluminium conductor of size 35 sqmm 3.5 core complete.
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation, trenches for laying poles/ cables/ pipe line etc. and getting out in soft/loose soil
Removing excavated materials to a distance n. exc. 50m and depositing where directed at a level n. exc 1.50m above the starting point.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil.
Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed. (Note: Punned thickness only shall be measured)
Supply and laying sub class 'B' bricks of old size (23x11x7cm) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
M &L Plain cement concrete 1:4:8 type C2 (using 40 mm aggregrate) as in foundations filling mass concrete complete all as specified and directed
Supply and fix or laid in road crossing/ fixed to poles, GI Pipe of 40 MM size light grade for protection of cable complete all as directed
Cutting trench through road/ wall to a width of 20cm and depth of 30cm for inserting GI protection pipe for drawing cable and filling back the trench with PCC 1:3:6 type C1 complete all as directed.
Boring of holoes under road , pavementy , hard standing by trenchless techanology using ultra sound techanique and necessary machinery including GI pipe 50 mm bore light grade for drawing cable complete all as specified and as directed.
Supply and fix time switche astro type (having longitude and latitude of indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure Make : Indoasian model No TL065AB0
M&L for making V shape of 45 degree angle between two side of bracket of pipe size 40 mm dia bent into and welding to existing 50 mm bracket with suitable size of MS channel all as specified and directed. Each side of bracket not less than 30 cm long complete
JAI ENTERPRISES
CIVILEC ENGINEERING WORKS
SRIESWARI ENTERPRISES
Prasur Electricals & Engineering Co.
BHARGAVI ENGINEERING CONSTRUCTIONS
Power engineering Associates
Venkateswara Electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .