Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC HOUSE NO 120 1 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 411014 | PUNE | MAHARASHTRA | 411014 | ₹11.9 L Quoted ₹12.7 L | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹13.0 L+₹31,120 (2.45%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹13.0 L+₹31,120 (2.45%) | L2 | Rejected-Finance Not a Lowest Bidder |
| 3 | L3₹13.1 L+₹42,470 (3.35%)Rejected-Finance PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | ₹13.1 L+₹42,470 (3.35%) | L3 | Rejected-Finance Not a Lowest Bidder |
| 4 | L4₹13.9 L+₹1.2 L (9.20%)Rejected-Finance C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | ₹13.9 L+₹1.2 L (9.20%) | L4 | Rejected-Finance Not a Lowest Bidder |
| 5 | L5₹14.2 L+₹1.5 L (11.6%)Rejected-Finance HAVELI FALIYA NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | ₹14.2 L+₹1.5 L (11.6%) | L5 | Rejected-Finance Not a Lowest Bidder |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
6 Mar 2020, 6:00 pmClosed
GE (AF) NALIYA
GE AF Naliya Kutch 370 655
REPAIR/REPLACEMENT OF FTL LIGHT FITTINGS WITH LED FITTINGS AND SOME MISC E/M WORKS AT AF STATION NALIYA UNDER GE(AF) NALIYA
2020_MES_312325_2
8675/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) NALIYA
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) NALIYA
₹36,000
Yes
4 Apr 2020
31 Jan 2020
9 Mar 2020
31 Jan 2020
6 Mar 2020
14 Feb 2020
Amount
S&F in replacement of LED batten for LED tube light with 01 No. of LED tube 18 Watt, fixed on two Nos. of square block with twin core copper flexible wire and including taking down old type tube light fitting etc complete all as specified and as directed. Make:- Bajaj Cat Part No. BLRB 18W CW for tube and BLRB-DB 118 for Batten or equivalent model & make of Bajaj/CG/Havells/Surya or as approved by GE.
S&F in replacement of sheet metal enclosure 4ways double door triple pole and neutral with 415 V, 200 amps rated bus bar with all accessories fixed in the wall including taking old DB's any type and cap and making good and match the existing surface of wall complete all as specified & directed.
S&F in replacement of Isolator 4 Pole 100 amps, 240 Volts complete all as specified & directed.
S&F in replacement of Isolator 4 Pole 63 amps, 240 Volts complete all as specified & directed.
S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, complete all as specified and as directed.
S&F in replacement of MCB, single pole and neutral, 35-63 Amps, 240 Volts, complete all as specified and as directed.
M&L in replacement for sub main wiring with two runs of single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS), drawn through and including PVC capping & casing not less than 25mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke (FRLS) as earth wire including taking down old unserviceable sub main wiring of any size with capping & casing/ conduit with all accessories complete all as specified and as directed. Note:- Two runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
M&L in replacement for sub main wiring with two runs of single core multistranded copper conductor cable, of size 10 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS), drawn through and including PVC capping & casing not less than 25mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 10 Sqmm, PVC insulated, unsheathed, fire retardant low smoke (FRLS) as earth wire including taking down old unserviceable sub main wiring of any size with capping & casing/ conduit with all accessories complete all as specified and as directed. Note:- Two runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
M&L in replacement for earthing complete with galvanized GI earth plate electrode of size 600mmx600mmx6mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and galvanized iron or steel, charcoal salt 15cm around the earth plate as shown in electrical plate No. 3 of SSR part-I, 20mm dia watering pipe medium grade 1.50 mtr long, GI protection pipe light grade 15mm dia from earth pit to main board including earthwork and excavation in any type of soil, refilling earth and removal of surplus soil upto 50 mtrs, PCC (1:3:6) type CI chamber, precast RCC cover 40mm thick, reinforced with 6mm dia MS bar 3 Nos. both way with handle made out of 6 mm dia MS bar and testing etc complete all as specified and as directed. Note:- (i) Length of GI protection pipe and earth lead wire shall not be less than 7.5 mtrs. (ii) On completeion, the earth resistance test to be carried out. If desired value of resistance not obtained, the earthing will be re-done at no extra cost.
Checking and attending complaints by means of repairing/rectifying the electric defects/faults related to electric equipments, device, accessories and fixtures maintained by MES. Tightening the loose connections complete all as specified & directed.
S&F in replacement of switch socket combination 2 in 1, multipurpose, 3 pin, 6/ 16 Amps, 250 V AC universal with box in polycarbonate complete all as specified and as directed.
S&F in replacement of switch piano, flush button type, single pole, one way, 5 Amps complete all as specified and as directed.
S&F in replacement of switch piano, flush button type, single pole, one way, 15 Amps complete all as specified and as directed.
S&F in replacement of switch piano, flush button type, single pole, two way, 5 Amps complete all as specified and as directed.
S&F in replacement of switch socket multipurpose, 2/3 pin, 5 Amps flush button type complete all as specified and as directed.
S&F in replacement of switch socket multipurpose 2 in 1, 5/15 Amps complete all as specified and as directed.
S&F in replacement of ceiling fan regulator step type for 1200/1400mm sweep ceiling fan including connections complete all as specified & directed.
S&F in replacement of electric bell ding dong AC 230 V SP with brass screw and cup washers complete all as specified & directed.
S&F in replacement of bell push flush type 5 Amps, 240 V complete all as specified & directed.
S&F in replacement of replacement of capacitor 2.5 mfd, 240V complete all as specified & directed.
S&F in replacement of angle holder suitable for LED lamp 7/12 watt complete all as specified & directed.
S&F in replacement of LED bulb of 7 watt complete all as specified & directed.
S&F in replacement of LED tube rod 20 watt of 4feet length with single side connection complete all as specified & directed.
S&F in replacement of Hylem sheet 3mm thick size 9"x11" including cutting of switch, socket complete all as specified & directed.
S&F in replacement of sheet 3mm thick size 8"x5" including cutting of switch, socket complete all as specified & directed.
S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, 50Hz AC made from moulded self extinguishing thermostate plastic and suitable for 10 KA breaking capacity complete all as specified and as directed. NOTE FOR ALL ITEMS OF SCH OF WORKS/BOQ 1. Contrctor shall deploy one eletrician (ITI holder with 5 years of experience) and one helper (minimum 8th pass and 3 years of experience). 2. Contractor shall provide all necessary tools and equipments to Electrician and helper and shall be responsible for thier safety. 3. Contractor or his representative shall report daily in complaint cell for collecting complaints. 4. Contractor shall maintain a complaint register & responsible for noting complaints in it & taking sign of User, JE and Engr-in-charge after rectification of complaint. 5. Rate shall be deemed including of minor items such as screws, nut bolts, cleat, PVC wire, conduit, casing caping upto 1m in length etc. 6. Complaint shall be rectified within 8hrs of notification, if contractor failed to do so, a panel recovery of Rs. 120.00 per day/complaint shall be recovered from next dues payments. 7.Emergent nature of complaint shall be attended immidiately on direction of JE, Engr-in-charge or GE upto 22:00 hrs, failing which recovery of Rs. 240.00 per day/complaint shall be leived on this account. 8. If any complaint shall be possible to rectify within prescribed time, the matter shall be immidiately brought out to notice in concerned JE or Engr-in-charge, no recovery shall be made on this account. The decision of accepting officer in this regard shall be final & binding. 9. Only labour involved and minor items required shall only be measured and paid in Srl Item 10.00 of sch of works/BOQ.
Vijay Construction Co
KALIKAY ENTERPRISES
Krishna Engineering
GEE CEE ENTERPRISES
M/s. Shree Shakti Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .