Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹12.9 LAccepted-AOC | 1st | Accepted-AOC L1 | |
| 2 | 2nd₹17.8 L+₹4.9 L (37.7%)Rejected-Finance | 2nd | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
2 Aug 2022, 5:00 pmClosed
Executive Engineer, UJS, Nainital
Office of Executive Engineer, Uttarakhand Jal Sansthan, Mallital, Nainital
Strengthening of Kokilabana (Kokilabana) Water Supply Scheme in Dhari, Nainital
2022_UKJS_46879_10
1159/E-Tender/07 Date - 08-07-2022
Open Tender
Civil Works
Item Rate
90 days
Nainital
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,770
Executive Engineer, UJS, Nainital
₹36,000
Nainital
10 Oct 2023
19 Jul 2022
3 Aug 2022
19 Jul 2022
2 Aug 2022
19 Jul 2022
19 Jul 2022
Amount
Pump and Related Electrical Items. Supply of Energy Efficient Submersible Pumpsets of various duty parameters, Make KSB Quotation Pump of 500 LPM dischage at 110 m head
Supply, Installation, Testing and commissioning (SITC) on turnkey basis for Fully Automatic Pump atomation control panels of different capacities having intelligent unit having FIELD PROGRAMMABLE LOGIC CONTROLLERS based SCADA Operated Pump Motor Start, Run Control Protect against Faults Automatically operated Control & management system for supervisory Control and data Acquisition System at punching water supply schemes & Two years Free of cost A. M. C for warranty period of following duties as per specifications sheet enclosed & suitable for integration in the existing system including cartage from work of manufacture upto site of work (16-40) HP SCADA BASED
G.I Barbed Wire Fencing 1.8 m high Providing and fixing 1.8 m high Gl barbed wire fencing with 2.4 m RCC M15 grade 150 mm x 150 mm concrete post placed every 3 m centre-to-centre founded in M15 grade cement concrete 0.6 m below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires. fixed with Gl staples, turn buckles etc. complete as per Clause 1705
Supply & Fixing of the following size pipes. including cartage of pipes. specials & fittings from site store to the site of works, lowering them into trenches, laying true to alignment & gradient, laying & joining of pipe line including cutting & threading of pipe for making up lengths as required for proper completion of work. G.I (Medium Class) Confirming to IS: 1239 (Part - I) / 2004
15 mm Dia
20 mm Dia
25 mm Dia
Supply & Fixing of following fittings including cartage of materials labour, T&P etc. complete GM Gate Valves
20 mm Dia
25 mm Dia
32 mm Dia
50 mm Dia
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Supply of all materials, labour, T&P etc and construction of R.C.C. CWR of following capacities ( in kiloliters ) with M.S. ladder outside & inside of the tank, M.S. M.H. cover with locking arrangement, supply and fixiing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover etc. complete with approved water proofing (apex) / enamal paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials, assuming bearing capacity as 8MT/M2.
For 5 KL CWR
For 15 KL CWR
For 12.50 KL CWR
For 4 KL CWR
Providing and making house service connections from water supply distribution GI pipe line upto water meter chamber inside the property using GI pipe including supply and fixing of electrofussion saddle ,brass ferrules elbow, ball valve etc complete with earthwork, road cutting with restoration works
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
Dismantling of Cement Concrete Pavements as per Technical Specification Clause 202. Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately
Construction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepared sub base with 43 grade cement or any other type PCC Grade M-30, coarse and fine aggregates conforming to IS: 383,maximum size of coarse aggregate not exceding 25 mm,mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications.
Excavation in ordinary soil (loam, clay, sand) for foundation including lift up to 1.5M and lead up to 30M filling waterring and ramming of Excavated the earth in to the trenches or into the sides between foundation trenches or in to the plinth
Excavation in soil mixed with shingle bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling,waterring and ramming of Excavated earth in the trenches
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Interconnection of new pipe line to existing pipe line including necessary cutting, supply and Installation of required specials fittings all as per direction of Engineer-In- Charge.
Dia Size 15-25
Dia Size 32-40
Kacha Road: provision for making payment to PWD /irrigation/Gram Panchayat And other Department fot reinstatement of road
Vipin Chandra Sanwal
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .