| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 13 L K ROAD KOEL OFF BOMBAY POONA ROAD KIRKEE PUNE MAHARASHTRA 411003 INDIA | PUNE | MAHARASHTRA | 411003 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹5.5 L
Closing Date
20 Aug 2020, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASD
NAVAL DOCKYARD VISAKHAPATNAM PIN 530014
TENDER ENQUIRY FOR FACILITATION OF ISPP CERTIFICATE FOR STP - IN SHIP
2020_NAVY_368651_1
COM/OFF/PGS/20-21/134
Single
Marine Services
Turn-key
80 days
NAVAL DOCKYARD VISAKHAPATNAM
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹5.5 L
Yes
21 Aug 2020
13 Aug 2020
21 Aug 2020
13 Aug 2020
20 Aug 2020
13 Aug 2020
13 Aug 2020 - 20 Aug 2020
180 days
SME.Replacement of flywheel ring on SME.20PA6B STC
SME.Balancing of flywheel along with rim gear SME.20PA6B STC
SME.Removal and fitment of inways connections .20PA6B STC
SME.Check LCP Start Interlocks & Pre- Starting sequence Prelub, slow barring before starting.20PA6B STC
SME.Check & renew if defective Reducers on Starting air panel. 40/23 bar & 23/7 bar (02 Nos).20PA6B STC
SME.Check & renew if defective LP Reducers on Local pneumatic supply panel. 40/7 bar(02 Nos).20PA6B STC
SME.Check & renew defective LCP Pneumatic Engraved Circuit components, solenoid/jaucomatic valves..20PA6B STC
SME.Calibrate all analog/ logic/ frequency signals of 02 in nos Engine Controllers at workshop..20PA6B STC
SME.Check fresh water thermostatic valve system including regulator, EP converter and positioner. Renew defective components..20PA6B STC
SME.Main engine bearing temperature sensors (11 nos) connectors to be renewed. Connector securing mount plate to be changed by yard as per requirement of KOEL. Note -Safeties system failure alarm observed due to connectors dry solder/ not secured properly..20PA6B STC
SME.ME connecting rod temp sensors connectors dry soldered. Connectors (10 Nos) to be checked & repair/ renew defective connectors..20PA6B STC
SME.ME exhaust gas temperature sensors to be checked. System to be calibrated..20PA6B STC
SME.ME air valve limit switches with box required to be renewed & carry out DI/DR for STC sequence failure alarm..20PA6B STC
MANDATORY SPARES: O - RING DIA. 7 x DIA. 215.76.507.35.0.00.20PA6B STC
DISC SPRING WASHER DIA.40XDIA.21.5X2.76.507.37.0.00.20PA6B STC
O - RING DIA. 17 x DIA. 232.76.520.39.0.00.20PA6B STC
GASKET.76.057.14.0.00.20PA6B STC
LOCTITE 242.79.001.34.0.00.20PA6B STC
O RING NO 129 21A7 (NSE 6.531).76.507.70.0.00.20PA6B STC
TURNING GEAR RIM.76.507.40.0.00.20PA6B STC
DISC SPRING WASHER DIA.56X DIA.28.5X3.76.507.36.0.00.20PA6B STC
O - RING DIA. 8.2 X DIA. 681.76.507.34.0.00.20PA6B STC
O RING AN 30, 21A7.76.175.91.0.00.20PA6B STC
SET BOLT - M16X2X50 - 8.8.50.002.16.050..20PA6B STC
LOCKING WIRE.74.254.28.0.00.20PA6B STC
ALLEN HEADED BOLT - M16 X 40L.50.011.16.040..20PA6B STC
PLAIN MACHINED WASHER - M16.50.506.16.000..20PA6B STC
COPPER WASHER (48X52).50.508.45.000..20PA6B STC
FLYWHEEL.76.507.80.0.00.20PA6B STC
SENSOR REF 19127.74.480.01.0.00.20PA6B STC
PICK UP + PLUG - SVEM.74.480.06.0.00.20PA6B STC
GESILCO COUPLING-CW.76.520.22.0.00.20PA6B STC
OIL FEEDING PIPE.76.175.15.0.00.20PA6B STC
T/C OIL FEEDING PIPE.76.175.16.0.00.20PA6B STC
O RING AN 30, 21A7.76.175.91.0.00.20PA6B STC
SET BOLT - M12X1.75X120 - 8.8.50.002.12.120..20PA6B STC
PNEUMATIC STARTER ASSLY.76.009.10.0.00.20PA6B STC
SET SCREW - M20X2.5X45 - 8.8.50.003.20.045..20PA6B STC
SPRING DOWEL.50.540.13.030..20PA6B STC
BARRING GEAR ASSLY - GALI, TYPE - GD.76.009.95.0.00.20PA6B STC
SUPPORT.76.009.22.0.00.20PA6B STC
SUPPORT PLATE.76.009.23.0.00.20PA6B STC
HAND RAIL.76.009.24.0.00.20PA6B STC
SET BOLT - M20X2.5X100 - 8.8.50.002.20.100..20PA6B STC
SET SCREW - M20X2.5X50 - 8.8.50.003.20.050..20PA6B STC
SPRING DOWEL.50.540.13.030..20PA6B STC
SET SCREW - M16X2X50 - 8.8.50.003.16.050..20PA6B STC
SUPPORT.76.079.13.0.00.20PA6B STC
SET SCREW - M20X2.5X40 - 8.8.50.003.20.040..20PA6B STC
PLATE.76.013.62.0.00.20PA6B STC
SET SCREW - M12X1.75X25 - 8.8.50.003.12.025..20PA6B STC
INNER STAR.76.520.41.0.00.20PA6B STC
SOLENOID VALVE.76.904.11.0.00.20PA6B STC
DISTRIBUTOR ISO ELECTROPNEUMATIC/SPRING.76.904.09.0.00.20PA6B STC
SOLENOID VALVE.76.904.26.0.00.20PA6B STC
DISTRIBUTOR ISO ELECTROPNEUMATIC/ELECTRIC.76.904.08.0.00.20PA6B STC
SOLENOID VALVE.76.904.11.0.00.20PA6B STC
FUEL RACK SENSOR 19121.74.404.02.0.00.20PA6B STC
SOLENOID VALVE + SOCKET.76.904.43.0.00.20PA6B STC
SUPPORT FOR PICKUP.76.161.01.0.00.20PA6B STC
SET SCREW - M12X1.75X35 - 8.8.50.003.12.035..20PA6B STC
LIMIT SWITCH- BARRING GEAR.76.009.14.0.00.20PA6B STC
PT 100 CONVERTER WITH TWO THRESHOLD.76.904.12.0.00.20PA6B STC
TEMP SENSOR.76.513.30.0.00.20PA6B STC
LIMIT SWITCH BOX - FOR AX90/5 ACTUATOR.74.489.46.0.00.20PA6B STC
SENSOR MBT1U-S-115-1/2-0.5-F1A-PMS-1/2" 110B.76.513.20.0.00.20PA6B STC
PRESSURE GAUGE.76.538.89.0.00.20PA6B STC
TEMPERATURE REGULATOR (FRESH WATER).76.909.21.0.00.20PA6B STC
TEMPERATURE SENSOR.76.059.03.0.00.20PA6B STC
EXHAUST PYROMETRIC DUCT BANK A.76.059.01.0.00.20PA6B STC
SENSOR - 19321.76.007.02.0.00.20PA6B STC
RTD INPUT FIELD MODULE.76.901.74.0.00.20PA6B STC
FIELD COMMUNICATION MODULE.76.901.75.0.00.20PA6B STC
LIMIT SWITCH FOR GACHOT VALVE.76.072.75.0.00.20PA6B STC
TRANSDUCER.76.503.54.0.00.20PA6B STC
ACTUATOR POSITIONER.76.503.53.0.00.20PA6B STC
VALVE BODY SERVICE KIT.76.503.56.0.00.20PA6B STC
ACTUATOR SERVICE KIT.76.503.57.0.00.20PA6B STC
COMPENSATION RTD SENSOR.75.971.56.0.00.20PA6B STC
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .