Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC D NO 38 22 40 NEAR LAKSHMI NARASHIMA THEATER 104 AREA VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹34.1 L+₹17,359.50 (0.51%)Rejected-Finance DOOR NO 58 1 236 6 FLAT NO A 104 SAMPATH ENCLAVE NAD KOTHA ROAD VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹35.1 L+₹1.2 L (3.57%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L3 | Rejected-Finance NON BONAFIED | |
| 4 | Rejected-Technical H NO 8 9 29 ASOKE NAGAR OLD GAJUWAKA VIZAG 530028 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530028 | - | Rejected-Technical NOT ENLISTED IN REQUISITE CATEGORY | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN REQUISITE CATEGORY |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
20 Oct 2020, 6:00 pmClosed
Garrison Engineer Utility-II
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
MANNING OPERATION FOR FIRE PH AT MOV OLD NAD SEWAGE DRINAGE PUMP HOUSE IN ABE PARK AREA AND INCL PERIODICAL PREVENTIVE MAINT AND CERTAIN EM WORKS AT NAD UNDER AGE EM NO II OF GE UTILITY II VISAKHAPATNAM
2020_MES_337692_1
8690
Open Tender
Electrical Maintenance Service
Item Rate
330 days
Garrison Engineer Utility-II Visakhapatnam
CLASS D
11 documents required · 11 mandatory
₹500
Garrison Engineer Utility-II
₹90,000
Yes
2 Nov 2020
22 Sept 2020
21 Oct 2020
22 Sept 2020
20 Oct 2020
6 Oct 2020
Amount
SCHEDULE "A' PART - I
Manning for operation and maintenance of sewage pump and area drainage pump and drinking water supply valves and lines at ABE Park/ DCDA complex in 02 Shifts a day of 08 hours each including sunday and holidays complete all as specified and as directed by Engineer-in-charge. Man Power:- One Semi-skilled person per shift Shift timings:- I st shift - 0400 Hrs to 1200 Hrs II nd shift - 1200 Hrs to 2000 Hrs
Details of installations to be manned as under :- (a) Details of pump set (Sewage pump) : Electric driven self priming type Centrifugal pump set non cloging type, Make : Kirloskar with LT panel etc. and all connected equipments etc. (b) Details of pump set (Drainage Pump): Monotel axially split casing pump of capacity 25 HP, 415 Volts, 3 Phase, 50Hz, 1450 RPM, 33 Amps. Make : Kirloskar with LT panel etc. and all the equipments etc. (c) Trouble free sluice/ gate valve operating and distribution of regular drinking water supply to the residential Accommodations at ABE Park, DCDA quarters from Existing over head reservoir in proper time. (d) The operator shall ensure trail run and be alert to run the DG Set 62.5 KVA capcity within 1 minute of power supply failure.
Wages for labour ( Basic + Dearness and other allowncess if any as per Latest labour Wages as notified by central / state Govt/Local body, which ever is higher)
Contribution towards Employees provident fund liability ( EPF ) (Employer's contribution as per Government latest rules)
Contribution towards Employees state insurance corporation ( ESIC ) (Employer's contribution as per Government latest rules)
Contribution towards Bonus
Overhead and profit
LWC (Labour welfare cess)
Note:- The rates to be quoted for complete items / subitems above inclusive of all taxes, cess, levies etc., as applicable including GST.
Manning for operation and maintenance of fire fighting pump sets including LT panel, pressure vessel and accessories with one skilled operator per shift of 8 hours each round the clock in 3 shifts a day including sunday and holidays for fire fighting installation at NAD (V) fire pump house complete all as specified and directed by Engineer -in- Charge. Man power:- One skilled person per shift Shift timings:- I st shift - 0600 Hrs to 1400 Hrs II nd shift - 1400 Hrs to 2200 Hrs III rd shift - 2200 Hrs to 0600 Hrs
List of equipments to be manned:- (a) Centrifugal pump set 90 BHP capacity electric driven motor AC 415 Volts, 3 phase - 01 No. (b) Centrifugal pump set 25 HP capacity electric driven motor AC 415 Volts, 3 phase - 01 No. (c) Centrifugal pump set diesel driven of capacity 110 HP - 01 No. (d) Responsible for trouble free operation operation of Sluice/ NRVs/ Gate Valves, Mild steel suction and delivery pipes, UG Sumps, Valve chambers, general cleanliness of installations etc. (e) LT Panel, with accessories viz starters, etc. (f) Regular monitoring of batteries viz charging, topping up of distilled water, cleaning of brass terminals and applying petroleum gelly time to time. (g) The pressure in the system to be maintained at 5.5 kg/Sqcm by putting jockey pump on Auto mode.
Wages for labour ( Basic + Dearness and other allowncess if any as per Latest labour Wages as notified by central / state Govt/Local body, which ever is higher)
Contribution towards Employees provident fund liability ( EPF ) (Employer's contribution as per Government latest rules)
Contribution towards Employees state insurance corporation ( ESIC ) (Employer's contribution as per Government latest rules)
Contribution towards Bonus
Overhead and profit
LWC (Labour welfare cess)
Note:- The rates to be quoted for complete items / subitems above inclusive of all taxes, cess, levies etc., as applicable including GST.
Manning for operation and maintanance of fire fighting pump sets including LT panel, pressure vessel and accessories with one skilled operator per shift of 8 hours round the clock in 3 shifts a day including sunday and holidays for the fire fighting installation at Old MO (V) fire pump house Old site including attending break down complaints, attend forthwith complete all as specified and directed by Engineer -in- Charge. Man power:- One skilled person per shift
Shift timings I st shift - 0600 Hrs to 1400 Hrs II nd shift - 1400 Hrs to 2200 Hrs III rd shift - 2200 Hrs to 0600 Hrs
List of equipments to be manned:- (a) Centrifugal pump set 90 BHP capacity electric driven motor AC 415V, 3 phase - 01 No. (b) Centrifugal pump set 25HP capacity electric driven motor AC 415V, 3 phase - 01 No. (c) Centrifugal pump set diesel driven of capacity 110 HP - 01 No. (d) Mild steel suction and delivery pipes, UG Sumps, Valve chambers, general cleanliness installations etc. (e) Resposible for trouble free operation of LT Panels with accessories viz starters, etc. (f) Regular monitoring of batteries viz charging, toping up of distilled water, cleaning of brass terminals and applying petroleum gelly time to time. (g) The pressure in the system to be maintained at 5.5 kg/cm2 by putting jockey pump on any mode.
Wages for labour ( Basic + Dearness and other allowncess if any as per Latest labour Wages as notified by central / state Govt/Local body, which ever is higher)
Contribution towards Employees provident fund liability ( EPF ) (Employer's contribution as per Government latest rules)
Contribution towards Employees state insurance corporation ( ESIC ) (Employer's contribution as per Government latest rules)
Contribution towards Bonus
Overhead and profit
LWC (Labour welfare cess)
Note:- The rates to be quoted for complete items / subitems above inclusive of all taxes, cess, levies etc., as applicable including GST.
Manning for operation and maintanance of fire fighting pump sets including LT panel, pressure vessel and accessories with one skilled operator per shift of 8 hours round the clock in 3 shifts a day including sunday and holidays for the fire fighting installation at BV yard fire pump house including attending break down complaints, attend forthwith complete all as specified and directed by Engineer -in- Charge. Man power:- One skilled person per shift
Shift timings I st shift - 0600 Hrs to 1400 Hrs II nd shift - 1400 Hrs to 2200 Hrs III rd shift - 2200 Hrs to 0600 Hrs
List of equipments to be manned:- (a) Centrifugal pump set 90 BHP capacity electric driven motor AC 415 Volts, 3 phase - 01 No. (b) Centrifugal pump set 25 HP capacity electric driven motor AC 415 Volts, 3 phase - 01 No. (c) Centrifugal pump set diesel driven of capacity 110 HP - 01 No. (d) Mild steel suction and delivery pipes, UG Sumps, Valve chambers, general cleanliness of installations etc. (e) Responsible for trouble free operation of LT Panel, with accessories viz starters, etc. (f) Regular monitoring of batteries viz charging, topping up of distilled water, cleaning of brass terminals and applying petroleum gelly time to time. (g) The pressure in the system to be maintained at 5.5 kg/Sqcm by putting jockey pump on Auto mode.
Wages for labour ( Basic + Dearness and other allowncess if any as per Latest labour Wages as notified by central / state Govt/Local body, which ever is higher)
Contribution towards Employees provident fund liability ( EPF ) (Employer's contribution as per Government latest rules)
Contribution towards Employees state insurance corporation ( ESIC ) (Employer's contribution as per Government latest rules)
Contribution towards Bonus
Overhead and profit
LWC (Labour welfare cess)
Note:- The rates to be quoted for complete items / subitems above inclusive of all taxes, cess, levies etc., as applicable including GST.
Note 1 for SL item No. 1 to 4:- Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recomended by Engineer-in- charge.
Note 2 for SL item No. 1 to 4:- 1. Contractor shall quote wages, employers contribution towards EPF liability, contribution towards ESIC, contribution towards bonus, LWC and overhead & profit separately as applicable as per instruction in vogue in respective sub items. 2. The rate quoted for items of outsourcing / Manning shall not be less than minimum wages as notified by Government of India/concerned state Government/Local Body, whichever is higher and also not less than applicable rates for contribution of employer towards EPF, contribution to ESIC, contribution of Bonus and LWC under respective heading / sub-items. In case any quoted rate against the above items / subitems mentioned above which correspond works out to lower than the prevailing minimum rate of wages / subscription / contribution towards EPF / ESIC/ Bonus / LWC the bid will be treated as non bonafide / invalid, shall be disqualified .....
...... and such bids will not be considered for acceptance. In such case, the lowest bidder shall be determined from amongst the valid / bonafide bids only and no claim on this account is entertained. The prevailing rate / wages / contribution shall be as applicable on the bid submission end date. 3. (a) The contractor shall submit the ID Proof, Bank Account No, EPF account number and ESIC account number of Operator / Person Employed. (b) The payment shall not be less than minimum labour wages and payment of labour / employee shall be made through Online Banking like NEFT/ RTGS etc,.
(c) The quoted rate in sub items of wages, EPF, ESIC and Bonus will be released only after producing authenticated Documentary proof of payment as per prevailing rates deposited in the concerned employees account duly signed by contractor and shall be submitted along with RAR / final Bill for payments. 4. Quotations with 'Nil' or "Zero" consideration (overhead and profit) will be considered non bonafide. 5. Any variation in minimum wages, liability of EPF / ESIC / Bonus / LWC / GST shall be adjusted for reimbursement/ Recovery as under:- (i) Variation in minimum wages including other related statutory provisions shall be adjusted in tems of condition 63 of GCC (IAFW-2249). (ii) Variation in percentage/ rate of GST and LWC shall be adjusted as per special conditions here in after which deals with "Reimbursement / Refund on Variation in Taxes Directly Related to Contract Value.
(iii) Rates shall be quoted only upto two digits after decimal. If any rate quoted/ derived by the contractor works out to more than two digits after decimal, then the same shall be rounded off upto two digits after decimal. The rounding off shall be done in accordance with rules for rounding off of Numerical Values in accordance with IS: 02 pf 1960 (Revised 2016) of BIS. 6. The contractor will be required to submit copy of valid labour licence from the labour Commissioner within 15 days of commencement of the work. If the contractor fails to submit the same within this stipulated period the contract shall be liable to be cancelled and the performance Security of the firm shall be forfeited accordingly.
7. (a) In case of requirement, tradesmen provided for one area may be utilised in other areas at the discretion of the department without any extra cost to department as directed by Engineer-in-Charge. (b) Tools & plants shall be provided by contractor. (c) Temporary laying of LTUG cable of any size and any lenth for restoration of supply during break down / other requirement deemed to be included in the above quoted rate. (d) Complaint register and Complaint slip books as per site requirement shall be provided by the contractor and cost of the same is deemed to be included in the quoted rate. (e) All workers employed by the contractor shall be in proper uniform with name plate and other safety wearing items , shoes during the duty as per the electricity rules, which deemed to included in quoted rate.
(f) Departmental equipments of each installation,shall be under safe custody . In case of theft of any item from installation recovery shall be made from the contractor as per direction of Engr-in-charge. (g) Group insurance for the operators shall be made by the contractor. Documents shall be submitted to the department. (h) Rate quoted shall be deemed to include for leave/reserve of staff.
SCHEDULE "A' PART - II
Supply and replace 150 mm bore CI sluice valves PN 1.6 (Raising type) conforming to IS 14846 flanged end with iron wheel head and stainless steel spindle flanged joints including necessary nuts, bolts, and washers etc., complete all as specified and directed.
All as per SL item No.05 above but of size 100 mm dia.
All as per SL item No.05 above but of size 80 mm dia.
M & L for Jungle cleaning by using JCB/BOBCAT and clearing away all grass vegetation, wild growth, sapling, shrubs, brushwoods, under growth roots, cutting of bushes, tree trunk of girth not execeeding 30 cm, cutting of trunk, portion protuding over ground, filling holes and leveling of ground and removing unserviceable materials to a distance n.exe 50m, compelte all as speicified
Labour for pressure testing of existing 200 mm dia DI/MS fire main system , identifying for leakages for rectifications including replacement of gland packing of sluice valves, rubber insertion packing, nut ,bolts etc of flanged joints/ defective flanges etc complete for making the system leak proof complete all directed by Engineer-in-charge. Note: (a) The rate quoted is deemed to be inclusive of T&P such as air compressor for pressure testing etc
All as per Sl. Item No.09 above but 150 mm dia
All as per Sl. Item No.09 above but 100 mm dia
All as per Sl. Item No.09 above but 80 mm dia
Repairing / Servicing and reassembling the Jockey pump set and motor of capacity 20/25 HP or 14/18.5 KW as per the original assembly after repairs / replacing the worn out unserviceable parts with new parts as ordered, including cleaning replacing the bearings for both pumps & motors including packing bolts, nuts washers and MS clamps etc and applying one coat of approved synthetic enamel paint on exposed steel surface, making the pump and motor fully serviceable including machine work etc., and testing the both after refixing and commissioning for satisfactory operation on its full load complete all as specified and directed by Engineer - in - Charge
M & L Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint. complete all as specified and as directed.
Supply and replace the following CI foot valve flanged type with necessary rubber gasket, bolts, nuts and washers complete all specified and directed.
150 mm dia.
100 mm dia.
80 mm dia.
Routine testing & maintenance of internal & external fire fighting equipment of multi storied building including yard hydrant, fire inlet valve, terrace valve, fire brigade inlet valve, NRVs, wet risers, floor landing double hydrant valves, hose with hose reel assembly and accessories for smooth and trouble free operation at heavy NAD area complete all as directed by Engineer in charge
M&L for PCC 1:3:6, type C1 (using 20 mm graded granite stone aggregate) as in trenches/bases/ pedestals for pipe lines, mud stops or chamfered on edges, including demolition of the existing cement concrete in ground floors complete all as specified and as directed.
M&L for Brickwork with modular fly ash bricks, straight or curved on plan exc 6M mean radius, built in CM (1:4) including demolition of the existing brick work complete all as specified and as directed.
M&L for takingdown existing leaking of following size sluice valves, identifying for leakages for rectifications and complete servicing including replacement of gland packing of sluice valves, rubber insertion packing, nut ,bolts etc of flanged joints/ defective flanges etc complete for making the system leak proof complete all directed by Engineer-in-charge. Note: (a) The rate quoted is deemed to be inclusive of earthwork if required and for applying one coat of synthetic enamel paint.
200 / 150 mm dia.
100 / 80 mm dia.
Dismantling centrifugal/ Mono block pump of capacity 75 to 110 HP, coupled with electric motor 3 phase 415 volt, 50 Hz from the foundation bed for repairs and including by removing the couping and foundation bolts etc, replacement of unserviceable parts i.e. impeller nut, keys, lock washer, gasket and greasing, reassembling coupling in position and reinstall the pump with necessary bolts, nuts and washers, cleaning and removing the scales of the following capacity of the pumpsets complete all as specified and directed by Engr-in-Charge:- Note : The quoted rate is deemed to be inclusive of replacement of necessary spare parts like Casing ring, latern ring, shaft sleeve, CI gland cover with MS studds, impeller, pump shaft, star coupling, terminals and ball bearings etc.,
All as per SL item No.20 above but 25 to 40 HP capacity.
Taking down existing electric motor of 75 to 110 HP capacity 3 phase, 415 Volts, 50 cycles AC from foundations bed / coupling, opening the motor, taking to workshop and removing the burnt windings, cleaning the stator and rotor with cleaning agent rewinding the motor with appropriate gauge of super enamelled copper wire of same gauge and same No of turns of existing make insulating winding with existing class of insulation varnishing baking up including replacement of base foundation nuts, bolts and re-installation of motor with suitable packing materials and connecting to the pump, testing the motor to satisfactory performance complete all as directed by Engineer-in-charge. Note : The quoted rate is deemed to inclusive of necessary Bearings as required.
All as per SL item No.22 above but 25 to 40 HP capacity.
Cleaning of sewage sump of 20,000 galons capacity by draining out liquid, deposited sludge and removal to a distance exc. 100 m and including scrapping the inner surface with wire brush, washing with water complete all as specified and directed by Engr-in-charge. Note:- This Job shall execute two times in the contract period and the same will be measured in two times.
Cleaning of sewage sump of 15,000 galons capacity by draining out liquid, deposited sludge and removal to a distence exc. 100 m and including scrapping the inner surface with wire brush, washing with water complete all as specified and directed by Engr-in-charge. Note:- This Job shall execute two times in the contract period and the same will be measured in two times.
M/S EVEREST INFRA
MVV Prasad
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .