Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹42.2 L+₹56,744 (1.36%)Rejected-AOC 32 1089 KALAMASSERY CHANGAMPUZHA NAGAR COCHIN ERNAKULAM KERALA 682033 | ERNAKULAM | KERALA | 682033 | L2 | Rejected-AOC L2 bidder | |
| 3 | L3₹43.2 L+₹1.5 L (3.55%)Rejected-AOC | L3 | Rejected-AOC L3 bidder | |
| 4 | L4₹44.6 L+₹2.9 L (7.02%)Rejected-AOC | L4 | Rejected-AOC L4 bidder | |
| 5 | L5₹45.7 L+₹4.0 L (9.59%)Rejected-AOC 8 34A FATHIMAPURAM TAMILNADU | TAMILNADU | L5 | Rejected-AOC L5 bidder |
Tender Value
₹47.8 L
EMD Value
₹50,000
Closing Date
26 Oct 2022, 12:00 pmClosed
Chief Executive Officer
Park Centre, Technopark Phase-1 Campus, Thiruvananthapuram - 695581
Revamping of conventional type streetlights in Technopark Phase-1 Campus
2022_ETPK_515113_1
ETPK/PH-1/2022-23/E-10
Open Tender
Electrical Works
Item Rate
60 days
Technopark Phase-1 Campus
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,950
₹50,000
7 Nov 2022
11 Oct 2022
27 Oct 2022
11 Oct 2022
26 Oct 2022
12 Oct 2022
Amount
4m height Black PU painted Hot Dip Galvanized mild steel pole with top dia. of 76mm, sheet thickness of 3.2mm with gold colour painted decorative cast aluminium rings along with designer double banner arm (design as per the tender document.) Base plate is welded to pole with dia. 140mm and thickness 4.5mm, 4 nos. mounting holes. The pole shall be installed on a 1:2:4 concrete plinth as approved by Technopark. The concrete plinth shall be of 45cmx45cmx60cm below the ground level and 45cmx45cmx10cm above the ground, providing separate adequate size 32mm OD pipes for incoming and outgoing power cables and earth wires with required nos. of GI foundation bolts of size 20mm dia 600 mm length, projected bolt size length 100 mm pitch circle dia 200mm to suit the holes of the base plate. The pole shall be cast vertically in the concrete, using template: the threaded portion protruded out side the plinth shall be galvanized. 6A SP MCB, neutral link, earth terminating facility and 16A, 4pole terminal block , end termination of cables etc shall be fixed inside the pole as required. Approved makes shall be as per tender document.
Supply of street light pole and all accessories including junction box etc.
Installation of street light pole including foundation, terminal/junction box etc.
LED Street Light Post Top with two nos of die-cast aluminum, epoxy powder coated black arms and die-cast aluminum epoxy powder coated black housing with heat sink for efficient thermal management, High quality UV Stabilized poly carbonate opal diffuser for glare free light distribution, IP 65 degree of protection , LED having lumen output not less than 3000 lumen ±10% per fixture, CCT should be between 3000K ± 10%, CRI>70. Luminaire shall have good thermal management system to limit the operating junction temperature of LED within the manufacturer’s recommendations. The system Voltage Range of 140 to 270 AC. System wattage of 65W ±10% per fixture. Constant current electronic driver should be equipped with Surge Voltage protection upto 10kV & other reliability test as per IS 15885 Part- 2/Sec 13. The operating Power factor shall be more than 0.90 (lag). The Total Harmonic distortion (voltage and current) shall be less than 10%. Suitable for mounding on pole mentioned in Item no. 1 (Similar to existing LED streetlight post top installed in the campus). Approved makes shall be as per tender document.
Supply
Installation
6m height Hot Dip Galvanized Octagonal Pole with top dia 70mm, bottom dia 130mm, sheet thickness 3mm, base plate of 200X200X12 mm size with 1500 mm long single arm bracket suitable for mounting one number of LED street light fitting as per the item 4 . The pole shall be installed on a 1:2:4 concrete plinth as per the detailed diagram. The concrete plinth shall be of 45cmx45cmx60cm below the ground level and 45cmx45cmx10cm above the ground, providing separate adequate size 32mm OD pipes for incoming and outgoing power cables and earth wires with required nos. of GI foundation bolts of size 20mm dia 600 mm length, projected bolt size length 100 mm pitch circle dia 200mm to suit the holes of the base plate. The pole shall be cast vertically in the concrete, using template: the threaded portion protruded out side the plinth shall be galvanized. 6A SP MCB, neutral link, earth terminating facility and 16A, 4pole terminal block etc shall be fixed inside the octagnal pole as required. Approved makes shall be as per tender clause 10.0
Supply of street light pole and all accessories including junction box etc.
Installation of street light pole including foundation, terminal/junction box etc.
LED street lights made up of pressure die cast aluminium water proof housing with IP 66 degree of protection, pole mounting clamps suitable for pole dia from 50-90mm, driver and accessories pre-wired upto terminal block in control gear compartment, System wattage of 25W ±10% per fixture. LED shall have lumen efficacy not less than 110 ±10% lumen per watt per fixture. CCT should be between 5500K - 6500K, CRI>70, Luminaire shall have good thermal management system to limit the operating junction temperature of LED within the manufacturer’s recommendations. Luminaire shall have UV resistant injection moulded polycarbonate lens as protector. Luminaire shall have integral fins and central spine attached to LED mounting area for better heat dissipation. The system voltage range of 12V. The driver should be equipped with surge protection (minimum 4.0kV). The operating Power factor shall be more than 0.95 (lag). The Total Harmonic distortion (voltage and current) shall be less than 10%. The efficiency of the luminaire shall be more than 85%. The Driver shall be constant current type of driver. Approved makes shall be as per tender clause 10.0
Supply
Installation
LED street lights made up of pressure die cast aluminium water proof housing with IP 66 degree of protection, pole mounting clamps suitable for pole dia from 50-90mm, driver and accessories pre-wired upto terminal block in control gear compartment, System wattage of 35W ±10% per fixture. LED shall have lumen efficacy not less than 110 ±10% lumen per watt per fixture. CCT should be between 5500K - 6500K, CRI>70, Luminaire shall have good thermal management system to limit the operating junction temperature of LED within the manufacturer’s recommendations. Luminaire shall have UV resistant injection moulded polycarbonate lens as protector. Luminaire shall have integral fins and central spine attached to LED mounting area for better heat dissipation. The system voltage range of 12V. The driver should be equipped with surge protection (minimum 4.0kV). The operating Power factor shall be more than 0.95 (lag). The Total Harmonic distortion (voltage and current) shall be less than 10%. The efficiency of the luminaire shall be more than 85%. The Driver shall be constant current type of driver. The work including dismantling of existing SV/MH etc in the street light pole . Approved makes shall be as per tender document.
Supply
Installation
LED Column Light with die-cast aluminium pipe housing with cylindrical opal polycarbonate diffuser designed for rugged outdoor usage of 3m hight, IP65 Degree of protection, LED having wattage of 40W ±10%, CCT should be between 3000K +10%, CRI>70. The system Voltage Range of 140 to 270 AC. In-built electronic driver should be equipped with Surge Voltage protection upto 4.5 kV. The operating Power factor shall be more than 0.90 (lag). The Total Harmonic distortion (voltage and current) shall be less than 10%. The pole shall be installed on a 1:2:4 concrete plinth as per the detailed diagram. The concrete plinth shall be of 14cmx14cmx60cm below the ground level and 14cmx14cmx5cm above the ground, providing separate adequate size 32mm OD pipes for incoming and outgoing power cables and earth wires with required nos. of GI foundation bolts of size 12mm dia to suit the holes of the base plate. The pole shall be cast vertically in the concrete, using template. Luminaire shall be provided with a base plate and fixing holes for directly mounting on the concrete plinth. Approved makes shall be as per tender document
Supply of luminaire and all accessories including junction box etc.
Installation including foundation, terminal/junction box etc.
LED bollard light with Graphite grey powder coated GI Pipe housing, High quality cone shape opal acrylic diffuser fixed in die-cast aluminium base for pleasant light distribution, IP65 Degree of protection, LED having wattage of 9W ±15%, CCT should be between 3000K - 3500K, CRI>70. The system Voltage Range of 140 to 270 AC. In-built electronic driver should be equipped with Surge Voltage protection upto 4.5 kV. The operating Power factor shall be more than 0.90 (lag). The Total Harmonic distortion (voltage and current) shall be less than 10%. The pole shall be installed on a 1:2:4 concrete plinth as per the detailed diagram. The concrete plinth shall be of 25cmx25cmx60cm below the ground level and 25cmx25cmx5cm above the ground, providing separate adequate size 32mm OD pipes for incoming and outgoing power cables and earth wires with required nos. of GI foundation bolts of size 12mm dia to suit the holes of the base plate. The pole shall be cast vertically in the concrete, using template: the threaded portion protruded out side the plinth shall be galvanized. Luminaire shall be provided with a base plate and fixing holes for directly mounting on the concrete plinth (Similar to Bajaj 'Tulip' and Havells CONE LED BOLLARD). Approved makes shall be as per tender document.
Supply of luminaire and all accessories including terminal/junction box etc.
Installation including foundation, terminal/junction box etc.
LED bush/spike light with powder coated integral Die-cast aluminium housing, IP67 Degree of protection, COB LED with reflector having wattage of 10W ± 20%, CCT should be between 3000K - 3500K, CRI>70. The system Voltage Range of 140 to 270 AC. In-built electronic constant current driver should be equipped with Surge Voltage protection . The operating Power factor shall be more than 0.90 (lag). The Total Harmonic distortion (voltage and current) shall be less than 10%. Approved makes shall be as per tender document.
Supply of luminaire and all accessories including terminal/junction box etc.
Installation including foundation, terminal/junction box etc.
LED bush/spike light with powder coated integral Die-cast aluminium housing, IP67 Degree of protection, COB LED with reflector having wattage of 15W ± 10%, CCT should be between 3000K - 3500K, CRI>70. The system Voltage Range of 140 to 270 AC. In-built electronic constant current driver should be equipped with Surge Voltage protection . The operating Power factor shall be more than 0.90 (lag). The Total Harmonic distortion (voltage and current) shall be less than 10%. Approved makes shall be as per tender document.
Supply of luminaire and all accessories including terminal/junction box etc.
Installation including foundation, terminal/junction box etc.
LED Buried Light with powder coated integral Die-cast aluminium housing, IP67 Degree of protection, COB LED with reflector having wattage of 6W ±10%, CCT should be between 3000K - 3500K, CRI>70. The system Voltage Range of 140 to 270 AC. In-built electronic constant current driver should be equipped with Surge Voltage protection . The operating Power factor shall be more than 0.90 (lag). The Total Harmonic distortion (voltage and current) shall be less than 10%. Approved makes shall be as per tender document.
Supply of luminaire including all accessories, terminal/junction box etc.
Installation including foundation, terminal/junction box and all accessories.
LED Step Light with powder coated integral Die-cast aluminium housing, IP66 Degree of protection, having wattage of 8W ±15%, CCT should be between 3000K to 3500K, CRI>70. The system Voltage Range of 140 to 270 AC. In-built electronic constant current driver should be equipped with Surge Voltage protection . The operating Power factor shall be more than 0.90 (lag). The Total Harmonic distortion (voltage and current) shall be less than 10%. Approved makes shall be as per tender document.
Supply of luminaire including all accessories, terminal/junction box etc.
Installation including foundation, terminal/junction box and all accessories.
LED Flood Light with powder coated integral Die-cast aluminium housing, IP66 Degree of protection with Fresnel diffuser, for wide angle light distribution, having wattage of 60W ±10%, CCT should be between 3000K to 3500K, CRI>70. The system Voltage Range of 140 to 270 AC. In-built electronic constant current driver should be equipped with Surge Voltage protection . The operating Power factor shall be more than 0.90 (lag). The Total Harmonic distortion (voltage and current) shall be less than 10%. Approved makes shall be as per tender document.
Supply of luminaire including all accessories, terminal/junction box etc.
Installation including foundation, terminal/junction box and all accessories.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.and disposing the same within upto 1km as per the directions from Technopark engineer in charge.
Supplying and fixing sintex box (weatherproof) of size 300x200x105mm with MCB rails arrangment of IP65 or above on surface suitable for installing single pole MCB/Isolators complete with connections, testing and commissioning etc. as required
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
50mm dia
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connections, testing and commisioning.
5A to 32A ,SP MCB
5A to 32A ,DP MCB
5A to 32A ,TP MCB
MCB Dummy
Supply and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Approved makes shall be as per tender document
2Cx 2.5 sqmm XLPE Al cable
2Cx 4 sqmm XLPE Al cable
2Cx 6 sqmm XLPE Al cable
2Cx 10 sqmm XLPE Al cable
4Cx 2.5 sqmm XLPE Al cable
4Cx 4 sqmm XLPE Al cable
4Cx 6 sqmm XLPE Al cable
4Cx 10 sqmm XLPE Al cable
4Cx 2.5 sqmm XLPE Cu cable
4Cx35sqmm XLPE Al cable
4Cx16sqmm XLPE Al cable
Supply and Laying/fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct/RCC Trench/METAL/GI pipe/ direct in to the ground below upto 30cm depth (including refilling the excavated portion) etc as required. Approved makes shall be as per tender document.
2Cx 2.5 sqmm XLPE Al cable
2Cx 4 sqmm XLPE Al cable
2Cx 6 sqmm XLPE Al cable
2Cx 10 sqmm XLPE Al cable
4Cx 2.5 sqmm XLPE Al cable
4Cx 4 sqmm XLPE Al cable
4Cx 6 sqmm XLPE Al cable
4Cx 10 sqmm XLPE Al cable
4Cx 2.5 sqmm XLPE Cu cable
4Cx35sqmm XLPE Al cable
4Cx16sqmm XLPE Al cable
Laying/fixing of Existing one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct/RCC Trench/METAL/GI pipe as required
Upto 35 sq. mm XLPE Al cable
Upto 35 sq. mm Cu cable
Supplying and making end termination with brass compression gland and aluminium lugs with Gland earthing for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2Cx 2.5 sqmm XLPE Al cable
2Cx 4 sqmm XLPE Al cable
2Cx 6 sqmm XLPE Al cable
2Cx 10 sqmm XLPE Al cable
4Cx 2.5 sqmm XLPE Al cable
4Cx 4 sqmm XLPE Al cable
4Cx 6 sqmm XLPE Al cable
4Cx 10 sqmm XLPE Al cable
4Cx 2.5 sqmm XLPE Cu cable
4Cx35sqmm XLPE Al cable
4Cx16sqmm XLPE Al cable
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4Cx 2.5 sqmm XLPE Cu cable
4Cx35sqmm XLPE Al cable
4Cx16sqmm XLPE Al cable
Supply and laying of 3C x 1.5 sq.mm PVC Insulated and PVC sheathed copper conductored round flexible copper wire manufactured with bright annealed copper conductor, Insulated and sheathed with electrical grade PVC. Approved makes shall be as per tender document.
Supply and laying of 4C x 2.5 sq.mm PVC Insulated and PVC sheathed copper conductored round flexible copper wire manufactured with bright annealed copper conductor, Insulated and sheathed with electrical grade PVC. Approved makes shall be as per tender document.
Supplying and drawing following sizes of 1.1kV FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
2Rx1.5sqmm with 1R 1.5sqmm Green wire for earthing
2Rx2.5sqmm with 1R 1.5sqmm Green wire for earthing
2Rx4sqmm with 1Rx2.5sqmm Green wire for earthing
Supplying and fixing of 20mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 25mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 20mm of PVC flexible conduit along with accessories in surface
Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as per IS:3043 along with existing surface/ recessed conduit/ submain wiring/ open trench / walls / pulling through pipes/cable as required in open trench / walls / pulling through pipes/cable etc as required.
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supply and installation of coil/spring earthing using 8 SWG, GI wire for street light pole etc. GI wire buried to a minimum depth of 1.5m, with excavation, refilling and connecting GI wire to pole using bolt and nut complete.
Supply, laying/fixing of 10 SWG copper for earthing of switchboard and jointing as per IS:3043 / 87 in open trench / walls / pulling through pipes etc as required.
Dismantling of bituminous road manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge
GERESH ELECTRICALS PVT. LTD
VIJAYA ELE TECHS PRIVATE LTD.
AKSHITH ELECTRICALS
Fathima Engineering Co. Pvt. Ltd.
candelaengineering corporation
PROTECTION & AUTOMATION ENGINEERS
DSK ELECTRIC POWER
stage.html
html • 0.06 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_738726.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .