| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹41.6 LAccepted-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | 1 | Accepted-AOC AOC | |
| 2 | 2₹44.9 L+₹3.3 L (7.84%)Rejected-Finance | 2 | Rejected-Finance NOT L1 | |
| 3 | 3₹44.9 L+₹3.3 L (7.97%)Rejected-Finance | 3 | Rejected-Finance NOT L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
8 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(ARMY) BHUJ
GE(ARMY) BHUJ
PROVN OF PORTA CABINS AT LOKDUNGAR,GADULY UNDER GE ARMY BHUJ
2022_MES_551102_1
8937
Open Tender
Civil Works
Item Rate
120 days
ARMY AREA BHUJ
REFER TENDER
6 documents required · 6 mandatory
₹500
GE(ARMY) BHUJ
₹90,000
Yes
21 Dec 2022
10 Sept 2022
10 Oct 2022
10 Sept 2022
8 Oct 2022
24 Sept 2022
Amount
M&L for 30m x 10m cabin, 6mm cement fibreboard sanwiched PIR insulation with corrugated PPGL roof cabin 2 partition and 3 door supporting framework made of Aluminum structurals 37x37 mm, 18-20 guage infill material of PIR insulation cement fibre bpared roofing material made of PPGL sheet 0.50 mm with FSK insulation and PVC false celing below 50mm x5mm ms tubeular truss fastener accessories fitment of split AC -5 Nobs all as shown in drawing and as specified.
M&L for 30m x 10m cabin, 6mm cement fibreboard sanwiched PIR insulation with corrugated PPGL roof cabin 2 partition and 3 door supporting framework made of Aluminum structurals 37x37 mm, 18-20 guage infill material of PIR insulation cement fibre bpared roofing material made of PPGL sheet 0.50 mm with FSK insulation and PVC false celing below 50mm x5mm ms tubeular truss fastener accessories fitment of split AC -4 Nobs all as shown in drawing and as specified.
M&L for 2mx2m Bunkhouse toilet with EWC, One Unrinal, washbasin and shower all as shown in drawing and specified.
M&L for Biogigestor units 1000 ltr with pipings all as shown in drawing and as speocified.
M & L for 1000 Ltr overhead water tank structure upto 6ft height all as shown in drawing and as speocified.
Note:- (i) The foundation of upto FFL shall be measured and paid sepratly under respective items as under (ii) The AC and elcetical items , sewage pipe line will be paid and measureed and paid sepretly.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil complete all as specified a
M&L for moorum/red bajri filling in floors or pavings, hard standing and in foundation laid in layers not exc 15cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-Charge.
M&L for anti termite treatment to the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-in-Charge.
M&L for anti termite treatment to the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified and directed by Engineer-in-Charge.
M&L for anti termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-in-Charge.
M&L for anti termite treatment to the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-in-Charge.
M&L for anti termite treatment to the soil alongwith external perimeter of building at the rate of 2.25 litres of emulsion per metre of the perimeter complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete type D-2 (1:4:8) (40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete type C-1:3:6(using 20 mm graded stone aggregate) as in lintels upto 1.5m clear span, steps, seismic and other similar bands coping/cills including necessary form work weathering, slightly rounded or chamfered angles and throating c
M&L for precast cement concrete (1:5:8) (using 40mm graded stone aggregate) block masonry with solid block exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick cement concrete type C-1 1:3:6 using 20 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. Exposed surfaces finished even and smooth without using extra cement inc
M&L for 25mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in flooring for tiles finish fair and even complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (sqaure/rectangular) area of each tiles exc. 0.06 Sqm but n.exc. 0.11 Sqm as per IS - 13755 in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including screed bed 15mm thick in cement mortar 1:6 complete as directed by EIC.
M&L for 15mm thick rendering in two layers on concrete surfaces , 1st coat 10mm thick in CM 1:6 and 2nd coat 5mm thick in CM 1:4 including WPC for second coat @ 3% by wt of cement and finished even and fair on walls (NOTE : Supply only WPC will be measured and paid for separately)
M&L for preparation of plastered or unplastered old decoreted extrernal surfaces of walls and applying two coats of exterior emulsion paint all as spepcified and directed by EIC,.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed on wall/tranches complete all as specified and directed
M&L for point wiring complete with FR PVC insulated unsheathed, 1100 V grade conforming in IS 694, 1.5 sqmm (nominal area) multi-stranded, copper conductor cable drawn through in non metallic rigid PVC surface casing & capping medium with suitable size of 1 to 8 module metal flush boxes and back plate for mounting of modular switches/socket and regulators and including modular front plate with all accessories complete
(a) One light point controlled by one way one switch SP 5 amps 240V
(b) One ceiling/exhaust fan point controlled by one way one switch SP 5 amp, 240 V
(c) One switch socket outlet 3 pin , 5 amps SP on independent
(d) One switch socket outlet 3 pin , 5 amps SP on same board
All as per the above item No 1 herein before but with 2.5 sqmm cable for 3 pin 5/15 amps switch socket outlet
S&F modular switch one way 6 amp, 1 module type complete
S&F modular socket 6 amp, 2/3 pin combined 2 module complete
S&F modular switch socket combination 6 amp/ 16 amps, 2/3 pin combined complete
S&F ceiling rose surface backlite 65/20 mm size three thermal ISI marked complete combination 6 amp/ 16 amps, 2/3 pin combined complete
Supply and fixing LED light fitting 1x20 W, 220 V AC decorative box type with driver, holder including LED tube light connecting up PVC insulated 3 core flexible from ceiling rose to fitting drawn through in PVC flexible conduit including as per site requirement and 2 Nos of round of square PVC block for fixing of FTL fitting complete all as per directed by Engr-in-Charge
Supply and fixing LED light fitting 600x600 mm, 36 watt 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases for suitable size complete all as per directed by Engr-in-Charge
Supply and fixing modular fan regulator step type 2 module complete
M&L for sub main wiring with two runs of 6.5 sqmm (2x6 sqmm) 1100 volts grade single core FR PVC insulated unsheathed multi-stranded copper conductor cable confirming to IS-694 conduit through and including non-metallic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in walls/roof/floors etc with one run of 4 sqmm (1x4 sqmm) single core FR PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed. Note:- 2 runs of 6.5 sqmm, one run of 4 sqmm (2.6 sqmm + 1x4 sqmm) cable and one meter of conduit will be measured as one unit again.
S&F sheet metal enclosures for distribution board when MCB to be used TPN (Triple pole and neutral) 8 way, 240 volts sheet metal powder coated IP-42 protection with 200 amps rated bus bar double door type complete all as specified and directed
S&F sheet metal enclosures for distribution board when MCB to be used SPN (Single Pole and neutral) 8 way, 240 volts sheet metal powder coated IP-42 protection with 200 amps rated bus bar double door type complete all as specified and directed
S&F RCBOs for earth leakage over load & short circuit protection, 415 volts 4 pole 30 Ma complete
S&F MCB SPN of capacity 40 amps 415 volts rupturing capacity 16 KA complete
S&F MCB SP 5 to 32 amps 240 volts rupturing capacity 10 KA 'C' series
M&L earthing complete for machinery / equipment installed at power house / sub station with galvanised steel earth plate electrode of size 60 c x 60 cm x 6 cm thick buries directly in ground (earth pit not less then 2.25 m deep below normal ground level connected galvanised earth lead wire 4.0 mm dia by means of bolts , nuts, washers and check nuts all shown in electrical plate No 5 of SSR Pt-I connected to main board / distribution board complete. Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinery / equipment testing point all as specified and testing on completion all as per directed
Note :- (i) The unit area shall also include for earth work in hard dense soil, PCC type C-1 (1:3:6) chamber, PCC 1:2:4 type B1 cover 50 mm thick reinforced with 8 mm dia TMT bars 150 mm c/c both ways funnel with watering pipe 20 mm dia medium graded GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No 1 (a) to (e) of preamble (notes) under sub heading earthing specified on Srl Page 389 of SSR Part-II
(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separately if required under appropriate schedule
Note :- (i) Earhting shall be tested as specified in clause 19.137 of SSR Pt-I 2009 to the entire satisfaction of Engr-in-Charge. (ii) On testing after completion of earthing, if the desire earth resistance is not obtained the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engr-in-Charge
Supply and fixing ceiling fans complete with blades, down rods electronics regulator and accessories, 230 V 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter voltage 230 v 50 Hz RPN 1200 copper winding of sweep 300 mm complete
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with inbuilt air nosier and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 Tom complete with all fitting accessories
Supply and fix voltage stabilized for automatic operation, single phase neutrally air cooled indoor type and designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of +/- 2.5% and of capacity 2.0 KVA complete all as specified
M&L for advance maintenance free chemical earthing with JMV CBE environment friendly ring earthing system consisting each set of 3 Nos of 10 feet length 40 dia earth electrode made of maintenance free electrolytic grade copper earthing system of JMV made based on flat in pipe technology of 3 mtr length 40 mm dia with crystallite conductive mixture compound filled with the permanent sealing at the top and bottom with the lead terminal of 25 x 4 mm size with 2 holes of 10 mm dia at the to, to be lowered in 150 mm dia bore including filling of back fill eco friendly earth enhancing compound tested by ROHS comply to IEC 62651-7 which should have passed leaching corrosion sulphur and resistivity test as per IEC 62651-7 by NABL accredit. LAB/JAM plus compound in 150 mm bore in immediate contact around the earth electrode and top of the bore shall be finished with 40 mm thick PCC in 1:2:4 type B1 over 75 mm thick PCC in 1:4:8 type D2 and backfill/JAM compound shall be covered with FRP pit cover of suitable size for each earth electrode, joint to be made by JAM weld exothermically welded technology including copper strip size 50 x 6 mm for earthing ring system and copper strip 32x6 mm size for earth electrode to test point with saddles and in case of plinth protection/floor/handstanding crossing complete all as specified and directed by Engr-in-Charge
Note : Earth work PCC work PCC cutting work by cutter and testing shall deemed to be included in unit rate quoted
Supplying laying passing through pipe connecting and testing UG cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 4 core complete
Excavation in trenches in soft/loose soil, not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in soft loose soil for laying of cable foundation of pole and stay etc in complete as specified
Returning filling including spreading, levelling watering and well ramming in layers n.exe 25 cm
Removing excavated materials not exceeding 50 mtr and depositing where directed at al level not exceeding 1.5 mtr above ground level for starting point
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation
Supplying and laying un-reinforced precast cable cross class LV type LV type 1 flat size 250 mmx 150 mm x 40 mm complete
Dismantling of all electric connection of existing UPS of capacity 5 KVS, 6 KVA, 7.5 KVA and connected accessories and shifting to other requirement place and assembling complete including all minor items as per site requirement
Labour only for shifiting of AC split type including all necessary fittin copper tube inlet and outlet with chrging of refrigent gas etc all as dircted by engineer in charge.
M/s Pal Builders
Ramdev and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .