Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.4 CrAccepted-AOC | ₹1.4 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹1.6 Cr+₹18.0 L (12.5%)Rejected-AOC | ₹1.6 Cr+₹18.0 L (12.5%) | 2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹3.3 L
Closing Date
24 Aug 2022, 5:00 pmClosed
Executive Engineer
Executive Engineer, Uttarakhand Jal Sansthan Haldwani situated at Tikoniya Nainital Road Haldwani District Nainital
Construction of Gujraura Water Supply Scheme including, Supply Installation, testing and commissioning of Rising Main, Distribution System, Repairing of OHT all appurtenance work etc. complete within Jal Jeevan Mission program under Haldwani Block
2022_UKJS_47787_6
1978/Jal Jeevan Mission/ Nivida/26 dated 30.07.20
Open Tender
Civil Works - Water Works
Item Wise
365 days
Haldwani
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
Executive Engineer, UJS
₹3.3 L
28 Aug 2023
16 Aug 2022
25 Aug 2022
16 Aug 2022
24 Aug 2022
16 Aug 2022
Rates for Construction of Gujraura Water Supply Scheme including, Supply Installation, testing & commissioning of Rising Main, Distribution System, Repairing of OHT all appurtenance work etc. complete within Jal Jeevan Mission program under HaldwaniBlock.
Construction Work :-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. - New work (Two or more coat )
Finishing walls with exterior paint of required shade - New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
62 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening compound is mixed @ 2 litre per 50 kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing & fixing fly proof wire gauze to windows and ventilator with M.S. Flat 15x3 m and nuts & bolts complete. - Galvanized M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides.
Painting Steel work(doors, windows, etc.) with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture.
Electrification of Pump House
Wiring for light point/fan point, exhaust fan point, call bell point with15.sq.mm FRLS PVC insulated copper conductor single core cable in surface, recessed medium class PVC conduit , with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc, as reuired.
Wiring for circutit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2x2.5 sq. mm +1x2.5sq.mm earth wire
2x4 sq. mm +1x4sq.mm earth wire
Wiring for light /Power plug point with 2x4.sq.mm FRLS PVC insulated copper conductor single core cable in surface, recessed medium class PVC conduit , alongwith 1 No. 4sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as reuired.
15/16Amp Switch
6 Pin 15/16Amp socket
S/F 3 pin , 5 amp celling rose on the exting junction box/wooden block including connection etc, as required.
S/F brss batten, angle holder including connctionetc, as requird.
supplying and fixing following way, single pole and neutral, sheet steel, MCB distribuiton board, 240v, on surface/recess, complete with tinned copper bus bar , neutral bus bar, earth bas, din bar, interconnections, power painted indulding earthing etc. as required (But without MCB/RCCB/Isolator) 6 way Double door
S/F 5 amps to 32amps rating, 240/415 volts, "C" curve, mainature circuit braker suitable for inductive load of follwing poles in the existing MCBDB compete with connection, testing and commissioning etc. as required. Single Pole
Double Pole
S/F of LED T_5, 18 watts tubelight fitting connection etc, compleat in all respect
S/F of exhaust fan (i.s.i mark) with jail, 450mm sweep, including making hole for exhaust fan and making good the damage, connection etc, co,pleat in all respect.
S/F of LED street light fitting 60 watts compete in all respect
S/F of G.I. 32mm size L type bracket clamps with fixing of street light etc.
S/F of 14 watts LED Bulb
S/F of wall fan 400mm sweep Model platina
E & M WORK AND ACCESSORIES FOR TUBEWELL
Lifting/lowering of 150 mm dia. Column pipe with supply and fixing including nut bolt, rubber packing, submersible cable jointing and NRV repair complete in all respect including cost of materials with all T&P required.
Repairment for fully automatic pump automation control pannel of suitable for 800 lpm 150 m head capacity having intelegent unit having" FIELD PROGRAMMABLE LOGIC CONTROLER based SCADA operated pump motor startRun Control Protactagainst faults automatically operated controle and management system" for supervisory control and data acquasition system at pumping water supply schemes & two year freeof cost AMC for warranty period of following dutiesas per specifications sheet enclosed &suaitable for integrationsin the existing system including cartage from works of manufactures up to site of work Capacity of suitable for 800 lpm 150 m.
Supply and fixing of 400 Amp TPN main switch 3 phase, 415 volt, 50 H havells make heavy duty double break main switch with HRC fuse making connection at this testing complete work etc at inter college tubewell.
Main piping and valves as per specification.
Supply of 150mm dia Column pipe, 6.4 mm thick -
Supply and fixing of suitable 16 mm thick MS Flange for column pipe both end with fixing trangle support and cutting of groove for cable all complete with labour& T&P
150mm dia size column pipe clamps.
Lifting tackle 10 tonne capacity Chain pulley. taparia make
Installation/Unforseen. (Including Providing and fixing of Clorinatior Dozer and other works)
Repairment of Boundary wall works
Repairment ofof 1.5 m high Boundary Wall in brick masonry including supply of all materials, labour, T&P etc. complete At proposed OHT Campus
Provision of Iron Gate with Pillars of following sizes complete 3.6 m wide
OHT repair
250 KL tank Forcleaning and conditioning of Tank. ( Clearner#10)
For arrest leakages.
Distribution of Pipe Line Works.
Providing, Lowering into trenches with true to alignment, Laying & Jointing of full lenghts of HDPE Pipes of specified grade as per IS:4984-1995 and specifications, with testing of pipe line including supply of jointing materials. HDPE Pipe Confirming to IS: 4984-1995/ PE-100 Grade Normal Pressure (PN) in 6.0 Kg/Cm2 63 mm dia
75 mm dia
90 mm dia
110 mm dia
140 mm dia
200 mm dia
Excavating in soil mixed with single boulders etc. requiring the use of specials T&P, if any, for pipe line trenches including lift up to 50m and lead upto 30m with back filling, watering, ramming of excavated earth in the trenches.(0.6 +dia)(1.0+dia)
125 mm dia
100 mm dia
50 mm dia
Constructing masonry Chamber, inside with 75 class designation brick work in cement mortar 1:4(1 cement: 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3(1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : - With F.P.S. bricks. 90x90x100
Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50metres lead as per direction of Engineer in charge- for bituminous road
Demolishing cement concrete manually/ by mechanical means incl- uding disposal of material within 50 metres lead as per direction of Engineer - in - charge. - for CC
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.- For Reinstatement
Bulk water meter (Electromagnetic flow meter) based on Microprocessor 125 mm
Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4(1 cement: 4 coarse sand ) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 (1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3(1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : - With F.P.S. bricks.
Shifting of FHTC's from old GI lines to new HDPE line. FHTC (Functional Household Tap Connection)
Excavation in soil mixed with single bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches. 15 mm dia GI Pipe
Providing of all materials, Carting from site store to site o fwork, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc complete. 15 mm dia GI Pipe
Making ferrule connection in the existing main of G.I, A.C, PVC or any type of pressure mains with saddle piece, service connections, fittings and fixing of G.M. ferrule including tapping the main, but excluding the cost of earth work and cost of all materials. 19.01 Ferrule Connection (Labour cost only)/Connection. Ferrule Connection (Labour cost only)
Cost of Material for ferruling in FHTC per connection as Lump Sum
M/S C.K. ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .