Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L1 | Accepted-AOC LOWEST AND REASONABLE RATE | |
| 2 | L2₹21.2 L+₹44,665.23 (2.16%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE |
Tender Value
₹19.1 L
EMD Value
₹38,200
Closing Date
15 Jan 2024, 6:00 pmClosed
GE ARMY BHUJ
GE ARMY BHUJ
SPECIAL REPAIR OF LT EM WORKS AND CERTAIN REV WORKS EM AT MIL STN GANDHIDHAM UNDER GE ARMY BHUJ
2023_MES_632660_1
8165
Open Tender
Civil Works
Item Rate
180 days
BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE ARMY
₹38,200
Yes
28 Feb 2024
14 Dec 2023
17 Jan 2024
14 Dec 2023
15 Jan 2024
28 Dec 2023
14 Dec 2023 - 28 Dec 2023
Amount
Supplying ,Laying , jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 10 Sqmm, 2 core laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
-ditto- here in before Item 1 but of size 4 core 16 Sqmm
-ditto- here in before Item 1 but of size 3.5 core 50 Sqmm
-ditto- here in before Item 1 but of size 3.5 core 70 Sqmm
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing surplus soil to a distance outside MD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Only compacted thickness of sand will be measured and paid separately.
M&L for laying sub class 'B' brick in trenches as cable protection covers across the length of the cable complete all as specified and directed by Engr-in-charge.
Supply, installation, testing and commissioning CPRI approved weather and vermin proof LT Panel box factory fabricated out door cubicle type (KIOSK type ) of size 1.2m x 1.0m x 0.5m , front and back openable , air vent , totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 65x65x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement with pad lock consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and civil work and copper bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including sleeves as per colour coading and connecting the following :- (Near GOD of Sec Hosp)
Incoming
(a) Laminated copper bus bar, 4 pole ( 3 phase & 1 for neutral) of size 50mm x 6mm -01 set
(b) MCCB 4 Pole, thermal adjustable, magnetic release, 415 volts, 400 Amp, 35 KA- 01 No
(e) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three)
(f) Digital Multifunctional meter - 01 No
Outgoing
(a) MCCB 4 Pole, thermal adjustable, magnetic release, 415 volts, 200 Amp, 35 KA- 02 Nos
(b) MCCB 4 Pole, thermal adjustable, magnetic release, 415 volts, 160 Amp, 35 KA-01
(c) Spare compartment for 63 Amps, MCCB 4 Pole - 01 Nos
Supply, installation, testing and commissioning CPRI approved weather and vermin proof LT Panel box factory fabricated out door cubicle type (KIOSK type ) of size 1.2m x 1.0m x 0.5m, front and back openable , air vent , totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 65x65x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement with pad lock consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and civil work and copper bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including sleeves as per colour coading and connecting the following :- (Near NFS, Near MES complaint cell)
Incoming
(a) Laminated copper bus bar, 4 pole ( 3 phase & 1 for neutral) of size 50mm x 6mm -01 set (Upto 600 Amps)
(b) MCCB 4 Pole, thermal adjustable, magnetic release, 415 volts, 250 Amp, 35 KA-01 No
(e) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three)
(f) Digital Multifunctional meter - 01 No
Outgoing
(a) MCCB 4 Pole, thermal adjustable, magnetic release, 415 volts, 160 Amp, 35 KA- 02 Nos
(b) MCCB 4 Pole, thermal adjustable, magnetic release, 415 volts, 100 Amp, 35 KA- 02 No
(c) MCCB 4 Pole, thermal adjustable, magnetic release, 415 volts, 63 Amp, 25 KA- 01 No
(d) Spare compartment for 63 Amps, MCCB 4 Pole- 01 Nos
Supply, installation, testing and commissioning CPRI approved weather and vermin proof LT Panel box factory fabricated out door cubicle type (KIOSK type ) of size 1.2m x 1.0m x 0.5m, front and back openable , air vent , totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement with pad lock consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and civil work and copper bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including sleeves as per colour coading and connecting the following :- (Backside of Sec Hosp)
Incoming
(a) Laminated copper bus bar, 4 pole ( 3 phase & 1 for neutral) of size 50mm x 6mm -01 set
(b) MCCB 4 Pole, thermal adjustable, magnetic release, 415 volts, 125 Amp, 36 KA-01 (Main incoming)
(e) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three)
(f) Digital Multifunctional meter - 01 No
Outgoing
(a) MCCB 4 Pole, thermal adjustable, magnetic release, 415 volts, 63 Amp, 25 KA- 03 Nos
(b) MCB TPN, 415 volts of capacity 40 Amps 16 KA 'B' series - 04 Nos
Supply, installation, testing and commissioning CPRI approved weather and vermin proof LT Panel box factory fabricated out door cubicle type (KIOSK type) of size 1.2m x 1.0m x 0.5m, front and back openable , air vent , totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement with pad lock consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and civil work and copper bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including sleeves as per colour coading and connecting the following :- (Backside of Dental Centre, Near Bde CSD, Near Sec Hosp)
Incoming
(a) Laminated copper bus bar, 4 pole ( 3 phase & 1 for neutral) of size 50mm x 6mm -01 set (Upto 600 Amps)
(b) MCCB 4 Pole, thermal adjustable, magnetic release, 415 volts, 100 Amp, 35 KA-01 No
(e) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three)
(f) Digital Multifunctional meter - 01 No
Outgoing
(a) MCCB 4 Pole thermal adjustable magnetic release 415 volts 63 A, 25 KA-02 Nos
(b) MCB SPN 40 Amps, 215 volts, 50 Hz, 'C' curve - 04 Nos
(c) Spare compartment for 63 Amps MCCB 4 Pole - 01 Nos
Transportation of Monoblock /Centrifugal/ Horizontal submersible pump set 5 HP to 12.5 HP, AC, Single/three phase, 220/440 V from pump house at any location/Yard in Cantt area contractor's workshop, dismantling for carrying out necessary repais / renewal of parts of pump and depositing the same after repair, reassembling complete all as specified. Note:- (i) New spares/parts shall be measured & paid separately under appropriate items listed here-in-after. (ii) Quoted rate shall be deemed included of transporting, repair, overhauling and replacement of spares complete.
Cutting, opening of winding, re- winding of monoblock pump set/ Horizontal submersible pump set of any make and rewinding with same size of copper winding wire, varnishing, backing complete as directed.
Supply & fix rubber coupling of pump as per requirement at site all asspecified and directed
Supply only water seal and packing complete
Supply only driven end bearing of pump shaft
Supply only non driven end bearing of pump shaft
Supply only cooling fan
Supply only cooling fan cover
Supply only CI impeller of as make all as directed
Supply only connection plate
Supply only capacitor of required capacity
Removing of Monoblock pump Set from its existing position and re-fixing of repaired pump set including replacement of worn out nuts & bolts and supply and fixed nuts, bolts and electric connection complete all as specified and directed.
Complete removal of old painted surfaces of pump set and applying two coat of synthetic enamel paint (1st quality) over a coat of metal primer (hammer tone finish) all as specified. Note:- Painting shall be done by spray machine.
Supplying, installing, commissioning and testing of inverter type split air conditioning unit 1.5 Ton indoor/ outdoor complete with cordless remote control unit, high ambient cooling, adjustable mode and stabiliser free operation with indbuilt with BEE 5 star rating inverter type with CFC refrigerant 1.5 tonne capacity complete and comprising of the following :- (a) Refrigerant copper pipe of suction and discharge line with insulation over pipe, condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safty valves & safety accessories including complete wiring for evaporator & condensing unit with fixing of suitable size of copper cable. (b) Fixing outdoor unit at suitable place and supply of bracket of 2 Nos for holding outdoor unit and make odd the disturbed surface to match with the existing surface after pluging the holes complete all as specified and directed
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all asspecified
Sub main wiring (PVC casing capping ) with two single core 4 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in PVC casing capping including one single core 2.5 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete and making good the disturbed surface in and including taking down old unservicable sub main wiring , complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 4 Sqmm ,1 run of PVC Casing capping & 1 run of 2.5 Sqmm cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
Radhe Krishn Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .