Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.6 LAccepted-AOC GANDERBAL | GANDERBAL | JAMMU AND KASHMIR | 191131 | ₹5.6 L | 1 | Accepted-AOC L-1 accepted |
| 2 | 2₹5.7 LRejected-Finance BUCHWARA DALGATE SRINAGAR J K 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹5.7 L | 2 | Rejected-Finance L-2 rejected |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not-Qualified as per SBD requirement |
| 4 | Rejected-Technical BUCHWARA DALGATE SRINAGAR J K 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | - | - | Rejected-Technical Not-Qualified as per SBD requirement |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not-Qualified as per SBD requirement |
| Sl No | Description | Qty | Unit | M/S HAMID ELECTRICAL AND MECHANIC ENGINEERING WORKS L2 | Dar Electrical, Mechnical & Supplier L1 |
|---|---|---|---|---|---|
| 1.00 | SITC of 200mm2 ACSR Conductor (Panther) | 1,000 | Mtrs | 110 ₹1.1 L | 294 ₹2.9 L |
| 2.00 | SITC of PG Clamps for 200 mm² ACSR Conductor | 60 | No’s | 2,800 ₹1.7 L | 250 ₹15,000 |
| 3.00 | SITC of T clamp for 200 mm² ACSR Conductor | 55 | No’s | 2,400 ₹1.3 L | 250 ₹13,750 |
| 4.00 | SITC of SF6 Gas Filling Kit | 1 | No | 20,000 ₹20,000 | 25,000 ₹25,000 |
| 5.00 | SITC of Trip Neutral Close (TNC) Switch, DC | 4 | No’s | 6,000 ₹24,000 | 6,000 ₹24,000 |
| 6.00 | SITC of Local Remote Selector Switch, DC | 4 | No’s | 6,000 ₹24,000 | 5,500 ₹22,000 |
| 7.00 | SITC of Auxiliary Switch, 7NO-7NC | 1 | No | 20,000 ₹20,000 | 3,000 ₹3,000 |
| 8.00 | SITC of Compressor Fan belt, A 1270 | 4 | No’s | 4,000 ₹16,000 | 2,500 ₹10,000 |
| 9.00 | Overhauling/Maintenance of 07 No’s, 132 kV, SF6 Breakers including its operating mechanism as per brief scope as under:
Checking of auto-starting of air compressor, oil pressure drop during duty cycle operation check, checking of auto-starting/stopping of oil pump, pressure switch setting, etc., checking of healthiness of accumulator by checking the pre-charging pressure when building up pressure from zero, checking of operation of safety valve, cleaning of breaker units, checking of protection equipments and replacement of defective ones to be provided by department,
i.e. complete inspection and testing of 132kV, SF6 type circuit breakers including inspection of operating mechanism, inspection of contacts and adjustment of various clearances, refilling of SF6 gas if required, venting of circuit breakers, etc. | 1 | LS | 30,000 ₹30,000 | 1,00,000 ₹1 L |
| 10.00 | Overhauling/Maintenance of 22 No’s, 132 kV, 3 phase Isolators including blades, operating mechanism of Isolators with earthing switches as per brief scope as under:
Checking of moving/fixed contacts, cleaning/ greasing of contacts, cleaning of post insulators and auxiliary switches, contacts, tightening of clamps, etc. | 1 | LS | 28,000 ₹28,000 | 56,000 ₹56,000 |
Tender Value
₹6.1 L
EMD Value
₹12,000
Closing Date
16 Dec 2024, 3:00 pmClosed
Executive Engineer, GD USHP-II, Kangan
Kangan, Ganderbal
Complete maintenance of 132kV switch yard of 105 MW (3x35) USHP-II, Kangan HEP
2024_SPDC_264103_1
USHP-II/GD/23 of 2024-25
Open Tender
Electrical Works
60 days
Kangan
As per SBD
5 documents required · 5 mandatory
₹500
Yes
CP and AO Kangan, JKPDC
₹12,000
Yes
6 Dec 2025
11 Nov 2024
17 Dec 2024
11 Nov 2024
16 Dec 2024
18 Nov 2024
11 Nov 2024 - 18 Nov 2024
Amount
SITC of 200mm2 ACSR Conductor (Panther)
SITC of PG Clamps for 200 mm² ACSR Conductor
SITC of T clamp for 200 mm² ACSR Conductor
SITC of SF6 Gas Filling Kit
SITC of Trip Neutral Close (TNC) Switch, DC
SITC of Auxiliary Switch, 7NO-7NC
SITC of Compressor Fan belt, A 1270
Overhauling/Maintenance of 07 No’s, 132 kV, SF6 Breakers including its operating mechanism as per brief scope as under: Checking of auto-starting of air compressor, oil pressure drop during duty cycle operation check, checking of auto-starting/stopping of oil pump, pressure switch setting, etc., checking of healthiness of accumulator by checking the pre-charging pressure when building up pressure from zero, checking of operation of safety valve, cleaning of breaker units, checking of protection equipments and replacement of defective ones to be provided by department, i.e. complete inspection and testing of 132kV, SF6 type circuit breakers including inspection of operating mechanism, inspection of contacts and adjustment of various clearances, refilling of SF6 gas if required, venting of circuit breakers, etc.
Overhauling/Maintenance of 22 No’s, 132 kV, 3 phase Isolators including blades, operating mechanism of Isolators with earthing switches as per brief scope as under: Checking of moving/fixed contacts, cleaning/ greasing of contacts, cleaning of post insulators and auxiliary switches, contacts, tightening of clamps, etc.
M/S HAMID ELECTRICAL AND MECHANIC ENGINEERING WORKS (BID ID -2251471)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid