Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
Closing Date
21 Oct 2026, 4:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Karnataka Forest Department
KALLAPPA
DEVELOPMENT OF ECO TOURISM FACILITIES AT HONNIKERI BIDAR RANGE (EOI)
KFD/2026-27/SE2142
KFD/2026-27/SE2142
Open
Electronic Documents, First(One Cover)
KFD DCF Territorial Division Office Bidar
3 documents required · 0 mandatory · 3 optional
₹500
12 Oct 2026
12 Oct 2026
19 Oct 2026
SNo Item Code Item Name Unit Category Code Specification Specification Value
1 CODE 1A PRE FAB COTTAGE-22*13 ft EACH 1A Supply, safe transportation, assembly, and commissioning of a Premium Prefabricated Modular Cottage Unit executed in strict accordance with the approved architectural layouts, floor plans, and elevation drawings. The unit's design parameters support a minimum service standard environmental exposure. Composite wall profile featuring an integrated core sandwich layer. This core must utilize high-density Polyurethane Foam (PUF) or mineral rock wool insulation. The exterior face must be sealed using weather-proof, fire-rated fiber cement siding boards or specialized treated wood-polymer composites Internal partitions sheeted with 12mm thick moisture-resistant gypsum boards or high-density fiber cement boards. Joints must be seamless, skim-coated, taped, finished smoothly, and painted with premium plastic emulsion paint over a low-VOC primer coat. Sloped, gabled, or flat structural roof framework containing a insulated sandwich decking core . The external surface must be capped with high-grade galvanized prepainted steel corrugated profiling for a fully waterproof finish. Heavy-duty internal structural floor base consisting of minimum 18mm thick cement-fiber board overlay sheets anchored securely to steel floor joists. Finished surface to be overlaid with commercial-grade anti-skid vitrified tiles, engineered SPC wooden flooring as specified by design parameters. Premium heavy-duty, weather-stripped UPVC or powder-coated aluminum sliding/openable window frames fitted with 5mm to 6mm thick clear structural Toughnned glass. Main entrance to feature a solid-core flush door with premium hardware laminates, security latches, and internal laminated flush doors for bathroom panels Inclusions: All internal concealed conduit pathways for electrical and plumbing lines, internal distribution DB boxes, structural scaffolding, safe lifting operations, material conveyance, and mechanical fastening anchoring clips. Including tranportation and fixing at the location. 1
1 CODE 1B PRE FAB COTTAGE-18*13 ft EACH 1B Supply, safe transportation, assembly, and commissioning of a Premium Prefabricated Modular Cottage Unit executed in strict accordance with the approved architectural layouts, floor plans, and elevation drawings. The unit's design parameters support a minimum service standard environmental exposure. Composite wall profile featuring an integrated core sandwich layer. This core must utilize high-density Polyurethane Foam (PUF) or mineral rock wool insulation. The exterior face must be sealed using weather-proof, fire-rated fiber cement siding boards or specialized treated wood-polymer composites Internal partitions sheeted with 12mm thick moisture-resistant gypsum boards or high-density fiber cement boards. Joints must be seamless, skim-coated, taped, finished smoothly, and painted with premium plastic emulsion paint over a low-VOC primer coat. Sloped, gabled, or flat structural roof framework containing a insulated sandwich decking core . The external surface must be capped with high-grade galvanized prepainted steel corrugated profiling for a fully waterproof finish. Heavy-duty internal structural floor base consisting of minimum 18mm thick cement-fiber board overlay sheets anchored securely to steel floor joists. Finished surface to be overlaid with commercial-grade anti-skid vitrified tiles, engineered SPC wooden flooring as specified by design parameters. Premium heavy-duty, weather-stripped UPVC or powder-coated aluminum sliding/openable window frames fitted with 5mm to 6mm thick clear structural Toughnned glass. Main entrance to feature a solid-core flush door with premium hardware laminates, security latches, and internal laminated flush doors for bathroom panels Inclusions: All internal concealed conduit pathways for electrical and plumbing lines, internal distribution DB boxes, structural scaffolding, safe lifting operations, material conveyance, and mechanical fastening anchoring clips. Including tranportation and fixing at the location. 1
1 CODE 1C PRE FAB COTTAGE-24*15 ft SQM 1C Supply, safe transportation, assembly, and commissioning of a Premium Prefabricated Modular Cottage Unit executed in strict accordance with the approved architectural layouts, floor plans, and elevation drawings. The unit's design parameters support a minimum service standard environmental exposure. Composite wall profile featuring an integrated core sandwich layer. This core must utilize high-density Polyurethane Foam (PUF) or mineral rock wool insulation. The exterior face must be sealed using weather-proof, fire-rated fiber cement siding boards or specialized treated wood-polymer composites Internal partitions sheeted with 12mm thick moisture-resistant gypsum boards or high-density fiber cement boards. Joints must be seamless, skim-coated, taped, finished smoothly, and painted with premium plastic emulsion paint over a low-VOC primer coat. Sloped, gabled, or flat structural roof framework containing a insulated sandwich decking core . The external surface must be capped with high-grade galvanized prepainted steel corrugated profiling for a fully waterproof finish. Heavy-duty internal structural floor base consisting of minimum 18mm thick cement-fiber board overlay sheets anchored securely to steel floor joists. Finished surface to be overlaid with commercial-grade anti-skid vitrified tiles, engineered SPC wooden flooring as specified by design parameters. Premium heavy-duty, weather-stripped UPVC or powder-coated aluminum sliding/openable window frames fitted with 5mm to 6mm thick clear structural Toughnned glass. Main entrance to feature a solid-core flush door with premium hardware laminates, security latches, and internal laminated flush doors for bathroom panels Inclusions: All internal concealed conduit pathways for electrical and plumbing lines, internal distribution DB boxes, structural scaffolding, safe lifting operations, material conveyance, and mechanical fastening anchoring clips. Including tranportation and fixing at the location. 1
2 CODE 02 EACH 1 ARTISTIC WORK- Providing and installation of Chicken mesh on 10mm MS bars welded to shape required for the artistic feature for mural arts wrapped with steel mesh covered with cement motor and finishing with primer and acrylic base paint and texture for realistic rocks, trees, wooden, creepers and any other natural works including cost of labour, material, machinery etc. excluding Foundation work only above the existing RCC or Ground lvl 1
3 CODE 03 SQM 1 ARTISTIC WORK ON WALL- Providing and installation of Chicken mesh for mural arts wrapped with steel mesh covered with cement motor and finishing with primer and acrylic base paint and texture for realistic wooden, creeper any other natural painting look, including cost of labour, material, machinery etc. 1
4 CODE 04 SQM 1 Providing and installation of stone coated sheet for the roof above the purlin fixing by overlapping on each other. complete as per specifications and as per Requierments 1
5 CODE 05 SQM 1 Providing and installation of Poly carbonate sheet all round below the roof upto the wall top (including sections from roof to wall and around the tree). complete as per specifications and as per directions of Engineer-in-charge. 1
6 CODE 06 SQM 1 Providing and installation of PVC bliends on the outer sruface for sun shade.3' on the sides of the top roof complete as per drawing in specification as per directions of Engineer-in-charge. 1
7 CODE 07 SQM 1 Providing and installation of for dining tables porpose (Wooden) 1
8 CODE 08 SQM 1 Supply of Chairs for the restaruant Wooden Chairs 1
9 CODE 09 SQM 1 Artist Work- Providing and installing cement concrete ferroce cement sclptures of animal figures (life size ar scaled) approvd theam and size including reinforcement, finishing, painting, curing and fixing in position, compelete as per drawing in specification 1
10 CODE 10 SQM 1 Artistic Stone Plastering in cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 1
11 CODE 11 LS 1 Tails & General Sinages 1
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
service_catalogue_items.xlsx
Tender Document • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .