| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 CrAccepted-AOC 37 CENTRAL ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | ₹21.5 Cr | L1 | Accepted-AOC Lowest tender accepted in TSECL 131st BOD meeting |
| 2 | L2₹21.9 CrRejected-Finance | ₹21.9 Cr | L2 | Rejected-Finance Quoted higher price than L1 Bidders |
| 3 | L3₹24.2 CrRejected-Finance T 3 PARMESHWARI BLDG CHATRIBARI RD GUWAHATI ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | ₹24.2 Cr | L3 | Rejected-Finance Quoted higher price than L1 and L2 Bidders |
| Sl No | Description | Qty | Unit | Curiosity Constructions Pvt Ltd L1 | T AND T PROJECTS LIMITED L3 | M/S HEMEN DEKA L2 |
|---|---|---|---|---|---|---|
| 2.00Power Transformer & Station Transformer | ||||||
| 3.00 | Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, & storage of 33/11 kV, 16 MVA Power Transformer complete along with all accessories , Off Circuit Tap Changer (OCTC) and Online Health conditioning monitoring & PD monitoring solution (As per Scope/Brief Description of Works &Technical Specification ). | 2 | No. | 2,60,10,000 ₹6,13,83,600 | 2,49,85,641.78 ₹5,89,66,114.6 | 2,35,57,000 ₹5,55,94,520 Lowest |
| 4.00 | Installation, testing, commissioning and operation of 33/11 kV, 16 MVA Power Transformer complete along with all accessories , Off Circuit Tap Changer (OCTC) and Online Health conditioning monitoring and PD monitoring solution. (As per Scope/Brief Description of Works &Technical Specification ). | 2 | No. | 5,00,000 ₹11,80,000 | 1,83,246.36 ₹4,32,461.42 Lowest | 3,00,000 ₹7,08,000 |
| 5.00 | Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, & storage of 11/0.433 kV, 200 KVA Station Transformer (As per Scope/Brief Description of Works &Technical Specification ).. | 1 | No. | 4,25,000 ₹5,01,500 Lowest | 11,78,787.21 ₹13,90,968.91 | 5,17,500 ₹6,10,650 |
| 6.00 | Installation, testing, commissioning and operation 11/0.433 kV, 200 KVA Station Transformer (As per Scope/Brief Description of Works &Technical Specification ). | 1 | No. | 10,000 ₹11,800 Lowest | 15,881.35 ₹18,739.99 | 10,000 ₹11,800 Lowest |
| 7.0033 kV Indoor Type Gas Insulated Switchgear (GIS) with 1250 Amps Bus having fault current withstand capacity of 31.5 kA for 3 sec and IAC AFLR 31.5 kA for 1 sec, Single Bus System, Segregated Plug-in type Busbar in GIS switchgears, SF6 shall be prefilled in busbar compartment at factory. 33 kV Protection, Control and Metering (PCM) in same 33 KV GIS panel (As per Scope/Brief Description of Works &Technical Specification). | ||||||
| 8.00 | Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 33 kV Line Incoming/Outgoing (1250 A) Feeder with Line Potential Transformer (PT) & Plugin Type Surge Arrester. Bushing CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). PT Ratio: 33000/√ 3:110/ √ 3:110/ √ 3 V,0.2 and 3P. Short Circuit Current Capacity: 31.5 kA for 3 sec.For PCM (Integrated with GIS switchgear): (a) Control, Protection, Metering Panel with complete assembly (b) Measuring instruments (0.2s class Programmable energy meter, multifunction meter, Ammeter, Voltmeter etc.) and others (c) Control & Protection IEDs (d) All circuit breaker's control with Local/Remote switch and metering data shall be brought under Substation Automation System (SAS). | 5 | Set | 48,25,000 ₹2,84,67,500 | 49,35,435.41 ₹2,91,19,068.94 | 45,12,500 ₹2,66,23,750 Lowest |
| 9.00 | Installation, testing, commissioning and operation of 33 kV Line Incoming/Outgoing (1250 A) Feeder with Line Potential Transformer (PT) & Plugin Type Surge Arrester. Bushing CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). PT Ratio: 33000/√ 3:110/ √ 3:110/ √ 3 V,0.2 and 3P. Short Circuit Current Capacity: 31.5 kA for 3 sec.For PCM (Integrated with GIS switchgear): (a) Control, Protection, Metering Panel with complete assembly (b) Measuring instruments (0.2s class Programmable energy meter, multifunction meter, Ammeter, Voltmeter etc.) and others (c) Control & Protection IEDs (d) All circuit breaker's control with Local/Remote switch and metering data shall be brought under Substation Automation System (SAS). | 5 | Set | 45,000 ₹2,65,500 Lowest | 48,865.7 ₹2,88,307.61 | 2,00,000 ₹11,80,000 |
| 10.00 | Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 33kV Bus Coupler with Riser (1250 A). CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). Short Circuit Current Capacity: 31.5 kA for 3 sec. For PCM (Integrated with GIS switchgear): (a).Control, Protection, Metering Panel with complete assembly (b).Control & Protection IEDs (c).All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS). | 1 | Set | 48,25,000 ₹56,93,500 | 49,35,435.41 ₹58,23,813.79 | 45,12,500 ₹53,24,750 Lowest |
| 11.00 | Installation, testing, commissioning and operation of 33kV Bus Coupler with Riser (1250 A). CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). Short Circuit Current Capacity: 31.5 kA for 3 sec. For PCM (Integrated with GIS switchgear): (a).Control, Protection, Metering Panel with complete assembly (b).Control & Protection IEDs (c).All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS). | 1 | Set | 45,000 ₹53,100 Lowest | 48,865.7 ₹57,661.52 | 50,000 ₹59,000 |
Tender Value
₹22.1 Cr
EMD Value
₹50 L
Closing Date
7 Jan 2026, 5:00 pmClosed
DGM,ED-I,Banamalipur,TSECL
O/O The DGM,ED-I, Banamalipur,TSECL
33/11 KV Gas Insulated Sub station at collegetilla under Electrical Division 1 TSECL Agartala West Tripura
2025_POWER_68129_1
DGM/ED-I/TSECL/2025-26/10
Open Tender
Electrical Works
Turn-key
Agartala, West Tripura
Please refer Tender documents.
8 documents required · 8 mandatory
₹50,000
Tripura State Electricity Corporation Limited
₹50 L
Corporate Conference Hall, Bidyut Bhavan, TSECL
16 Jul 2026
8 Dec 2025
9 Jan 2026
10 Dec 2025
7 Jan 2026
29 Dec 2025
11 Dec 2025 - 17 Dec 2025
20 Dec 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Power Transformer & Station Transformer | - | - | - | - |
| 3 | Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, & storage of 33/11 kV, 16 MVA Power Transformer complete along with all accessories , Off Circuit Tap Changer (OCTC) and Online Health conditioning monitoring & PD monitoring solution (As per Scope/Brief Description of Works &Technical Specification ). | 2 | No. | - | - |
| 4 | Installation, testing, commissioning and operation of 33/11 kV, 16 MVA Power Transformer complete along with all accessories , Off Circuit Tap Changer (OCTC) and Online Health conditioning monitoring and PD monitoring solution. (As per Scope/Brief Description of Works &Technical Specification ). | 2 | No. | - | - |
| 5 | Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, & storage of 11/0.433 kV, 200 KVA Station Transformer (As per Scope/Brief Description of Works &Technical Specification ).. | 1 | No. | - | - |
| 6 | Installation, testing, commissioning and operation 11/0.433 kV, 200 KVA Station Transformer (As per Scope/Brief Description of Works &Technical Specification ). | 1 | No. | - | - |
| 7 | 33 kV Indoor Type Gas Insulated Switchgear (GIS) with 1250 Amps Bus having fault current withstand capacity of 31.5 kA for 3 sec and IAC AFLR 31.5 kA for 1 sec, Single Bus System, Segregated Plug-in type Busbar in GIS switchgears, SF6 shall be prefilled in busbar compartment at factory. 33 kV Protection, Control and Metering (PCM) in same 33 KV GIS panel (As per Scope/Brief Description of Works &Technical Specification). | - | - | - | - |
| 8 | Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 33 kV Line Incoming/Outgoing (1250 A) Feeder with Line Potential Transformer (PT) & Plugin Type Surge Arrester. Bushing CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). PT Ratio: 33000/√ 3:110/ √ 3:110/ √ 3 V,0.2 and 3P. Short Circuit Current Capacity: 31.5 kA for 3 sec.For PCM (Integrated with GIS switchgear): (a) Control, Protection, Metering Panel with complete assembly (b) Measuring instruments (0.2s class Programmable energy meter, multifunction meter, Ammeter, Voltmeter etc.) and others (c) Control & Protection IEDs (d) All circuit breaker's control with Local/Remote switch and metering data shall be brought under Substation Automation System (SAS). | 5 | Set | - | - |
| 9 | Installation, testing, commissioning and operation of 33 kV Line Incoming/Outgoing (1250 A) Feeder with Line Potential Transformer (PT) & Plugin Type Surge Arrester. Bushing CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). PT Ratio: 33000/√ 3:110/ √ 3:110/ √ 3 V,0.2 and 3P. Short Circuit Current Capacity: 31.5 kA for 3 sec.For PCM (Integrated with GIS switchgear): (a) Control, Protection, Metering Panel with complete assembly (b) Measuring instruments (0.2s class Programmable energy meter, multifunction meter, Ammeter, Voltmeter etc.) and others (c) Control & Protection IEDs (d) All circuit breaker's control with Local/Remote switch and metering data shall be brought under Substation Automation System (SAS). | 5 | Set | - | - |
| 10 | Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 33kV Bus Coupler with Riser (1250 A). CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). Short Circuit Current Capacity: 31.5 kA for 3 sec. For PCM (Integrated with GIS switchgear): (a).Control, Protection, Metering Panel with complete assembly (b).Control & Protection IEDs (c).All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS). | 1 | Set | - | - |
| 11 | Installation, testing, commissioning and operation of 33kV Bus Coupler with Riser (1250 A). CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). Short Circuit Current Capacity: 31.5 kA for 3 sec. For PCM (Integrated with GIS switchgear): (a).Control, Protection, Metering Panel with complete assembly (b).Control & Protection IEDs (c).All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS). | 1 | Set | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.81 MB
Tendernotice_2.pdf
PDF • 4.60 MB
BOQ_69326.xls
BOQ • 0.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].