| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 CrAdmitted-Finance | ₹21.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹21.9 CrAdmitted-Finance | ₹21.9 Cr | L2 | Admitted-Finance |
| 3 | L3₹24.2 CrAdmitted-Finance T 3 PARMESHWARI BLDG CHATRIBARI RD GUWAHATI ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | ₹24.2 Cr | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Curiosity Constructions Pvt Ltd L1 | T AND T PROJECTS LIMITED L3 | M/S HEMEN DEKA L2 |
|---|---|---|---|---|---|---|
| 2.00Power Transformer & Station Transformer | ||||||
| 3.00 | Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, & storage of 33/11 kV, 16 MVA Power Transformer complete along with all accessories , Off Circuit Tap Changer (OCTC) and Online Health conditioning monitoring & PD monitoring solution (As per Scope/Brief Description of Works &Technical Specification ). | 2 | No. | 2,60,10,000 ₹6.1 Cr | 2,49,85,641.78 ₹5.9 Cr | 2,35,57,000 ₹5.6 Cr |
| 4.00 | Installation, testing, commissioning and operation of 33/11 kV, 16 MVA Power Transformer complete along with all accessories , Off Circuit Tap Changer (OCTC) and Online Health conditioning monitoring and PD monitoring solution. (As per Scope/Brief Description of Works &Technical Specification ). | 2 | No. | 5,00,000 ₹11.8 L | 1,83,246.36 ₹4.3 L | 3,00,000 ₹7.1 L |
| 5.00 | Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, & storage of 11/0.433 kV, 200 KVA Station Transformer (As per Scope/Brief Description of Works &Technical Specification ).. | 1 | No. | 4,25,000 ₹5.0 L | 11,78,787.21 ₹13.9 L | 5,17,500 ₹6.1 L |
| 6.00 | Installation, testing, commissioning and operation 11/0.433 kV, 200 KVA Station Transformer (As per Scope/Brief Description of Works &Technical Specification ). | 1 | No. | 10,000 ₹11,800 | 15,881.35 ₹18,739.99 | 10,000 ₹11,800 |
| 7.0033 kV Indoor Type Gas Insulated Switchgear (GIS) with 1250 Amps Bus having fault current withstand capacity of 31.5 kA for 3 sec and IAC AFLR 31.5 kA for 1 sec, Single Bus System, Segregated Plug-in type Busbar in GIS switchgears, SF6 shall be prefilled in busbar compartment at factory. 33 kV Protection, Control and Metering (PCM) in same 33 KV GIS panel (As per Scope/Brief Description of Works &Technical Specification). | ||||||
| 8.00 | Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 33 kV Line Incoming/Outgoing (1250 A) Feeder with Line Potential Transformer (PT) & Plugin Type Surge Arrester. Bushing CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). PT Ratio: 33000/√ 3:110/ √ 3:110/ √ 3 V,0.2 and 3P. Short Circuit Current Capacity: 31.5 kA for 3 sec.For PCM (Integrated with GIS switchgear): (a) Control, Protection, Metering Panel with complete assembly (b) Measuring instruments (0.2s class Programmable energy meter, multifunction meter, Ammeter, Voltmeter etc.) and others (c) Control & Protection IEDs (d) All circuit breaker's control with Local/Remote switch and metering data shall be brought under Substation Automation System (SAS). | 5 | Set | 48,25,000 ₹2.8 Cr | 49,35,435.41 ₹2.9 Cr | 45,12,500 ₹2.7 Cr |
| 9.00 | Installation, testing, commissioning and operation of 33 kV Line Incoming/Outgoing (1250 A) Feeder with Line Potential Transformer (PT) & Plugin Type Surge Arrester. Bushing CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). PT Ratio: 33000/√ 3:110/ √ 3:110/ √ 3 V,0.2 and 3P. Short Circuit Current Capacity: 31.5 kA for 3 sec.For PCM (Integrated with GIS switchgear): (a) Control, Protection, Metering Panel with complete assembly (b) Measuring instruments (0.2s class Programmable energy meter, multifunction meter, Ammeter, Voltmeter etc.) and others (c) Control & Protection IEDs (d) All circuit breaker's control with Local/Remote switch and metering data shall be brought under Substation Automation System (SAS). | 5 | Set | 45,000 ₹2.7 L | 48,865.7 ₹2.9 L | 2,00,000 ₹11.8 L |
| 10.00 | Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 33kV Bus Coupler with Riser (1250 A). CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). Short Circuit Current Capacity: 31.5 kA for 3 sec. For PCM (Integrated with GIS switchgear): (a).Control, Protection, Metering Panel with complete assembly (b).Control & Protection IEDs (c).All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS). | 1 | Set | 48,25,000 ₹56.9 L | 49,35,435.41 ₹58.2 L | 45,12,500 ₹53.2 L |
| 11.00 | Installation, testing, commissioning and operation of 33kV Bus Coupler with Riser (1250 A). CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). Short Circuit Current Capacity: 31.5 kA for 3 sec. For PCM (Integrated with GIS switchgear): (a).Control, Protection, Metering Panel with complete assembly (b).Control & Protection IEDs (c).All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS). | 1 | Set | 45,000 ₹53,100 | 48,865.7 ₹57,661.52 | 50,000 ₹59,000 |
Updated dates
Tender Value
₹22.1 Cr
EMD Value
₹50 L
Closing Date
30 Jan 2026, 5:00 pmClosed
DGM,ED-I,Banamalipur,TSECL
O/O The DGM,ED-I, Banamalipur,TSECL
33/11 KV Gas Insulated Sub station at collegetilla under Electrical Division 1 TSECL Agartala West Tripura
2025_POWER_68129_1
DGM/ED-I/TSECL/2025-26/10
Open Tender
Electrical Works
Agartala, West Tripura
Please refer Tender documents.
8 documents required · 8 mandatory
₹50,000
Tripura State Electricity Corporation Limited
₹50 L
Corporate Conference Hall, Bidyut Bhavan, TSECL
23 Mar 2026
8 Dec 2025
2 Feb 2026
10 Dec 2025
30 Jan 2026
29 Dec 2025
11 Dec 2025 - 17 Dec 2025
20 Dec 2025
Power Transformer & Station Transformer
Total Unit price/Amount Column(4*13)
Total Freight & Insurance Charges Column(4*14)
33 kV Indoor Type Gas Insulated Switchgear (GIS) with 1250 Amps Bus having fault current withstand capacity of 31.5 kA for 3 sec and IAC AFLR 31.5 kA for 1 sec, Single Bus System, Segregated Plug-in type Busbar in GIS switchgears, SF6 shall be prefilled in busbar compartment at factory. 33 kV Protection, Control and Metering (PCM) in same 33 KV GIS panel (As per Scope/Brief Description of Works &Technical Specification).
Total Erection Charges Column(4*15)
Total amount of GST applied Column(4*16)
Total Ex-works price (inclusive all taxes) Column(22+27)
GRAND TOTAL AMOUNT Column (24+27)
GRAND TOTAL AMOUNT (With Taxes) Column (24+25+26+27)
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, & storage of 33/11 kV, 16 MVA Power Transformer complete along with all accessories , Off Circuit Tap Changer (OCTC) and Online Health conditioning monitoring & PD monitoring solution (As per Scope/Brief Description of Works &Technical Specification ).
Installation, testing, commissioning and operation of 33/11 kV, 16 MVA Power Transformer complete along with all accessories , Off Circuit Tap Changer (OCTC) and Online Health conditioning monitoring and PD monitoring solution. (As per Scope/Brief Description of Works &Technical Specification ).
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, & storage of 11/0.433 kV, 200 KVA Station Transformer (As per Scope/Brief Description of Works &Technical Specification )..
Installation, testing, commissioning and operation 11/0.433 kV, 200 KVA Station Transformer (As per Scope/Brief Description of Works &Technical Specification ).
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 33 kV Line Incoming/Outgoing (1250 A) Feeder with Line Potential Transformer (PT) & Plugin Type Surge Arrester. Bushing CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). PT Ratio: 33000/√ 3:110/ √ 3:110/ √ 3 V,0.2 and 3P. Short Circuit Current Capacity: 31.5 kA for 3 sec.For PCM (Integrated with GIS switchgear): (a) Control, Protection, Metering Panel with complete assembly (b) Measuring instruments (0.2s class Programmable energy meter, multifunction meter, Ammeter, Voltmeter etc.) and others (c) Control & Protection IEDs (d) All circuit breaker's control with Local/Remote switch and metering data shall be brought under Substation Automation System (SAS).
Installation, testing, commissioning and operation of 33 kV Line Incoming/Outgoing (1250 A) Feeder with Line Potential Transformer (PT) & Plugin Type Surge Arrester. Bushing CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). PT Ratio: 33000/√ 3:110/ √ 3:110/ √ 3 V,0.2 and 3P. Short Circuit Current Capacity: 31.5 kA for 3 sec.For PCM (Integrated with GIS switchgear): (a) Control, Protection, Metering Panel with complete assembly (b) Measuring instruments (0.2s class Programmable energy meter, multifunction meter, Ammeter, Voltmeter etc.) and others (c) Control & Protection IEDs (d) All circuit breaker's control with Local/Remote switch and metering data shall be brought under Substation Automation System (SAS).
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 33kV Bus Coupler with Riser (1250 A). CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). Short Circuit Current Capacity: 31.5 kA for 3 sec. For PCM (Integrated with GIS switchgear): (a).Control, Protection, Metering Panel with complete assembly (b).Control & Protection IEDs (c).All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS).
Installation, testing, commissioning and operation of 33kV Bus Coupler with Riser (1250 A). CT Ratio: 600-1200/1-1 A, 0.2S (1 nos), 5P30 (1 nos). Short Circuit Current Capacity: 31.5 kA for 3 sec. For PCM (Integrated with GIS switchgear): (a).Control, Protection, Metering Panel with complete assembly (b).Control & Protection IEDs (c).All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS).
Control, Protection, Substation Automation and Metering (Automation Should Consider the future integration of Smart Grid and Must be Compatible with SCADA and Smart Grid Protocol) (As per Scope/Brief Description of Works, Technical Specification and GTP).
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 33kV Transformer Feeder Panel (1250 A) with Potential Transformer (PT) & Plugin Type Surge Arrester. Bushing CT Ratio: 300-600/1-1-1 A, 0.2S (1 nos), 5P30 (2 nos). PT Ratio: 33000/√3:110/√3:110/√3 V, 0.2 and 3P. Short Circuit Current Capacity: 31
.5 kA for 3 sec. For PCM (Integrated with GIS switchgear): (a) Control, Protection, Metering Panel with complete assembly (b) Measuring instruments (0.2s class Programmable energy meter, multifunction meter, Ammeter, Voltmeter etc) and others (c) Control & Protection IEDs (d) All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS).
Installation, testing, commissioning and operation of 33kV Transformer Feeder Panel (1250 A) with Potential Transformer (PT) & Plugin Type Surge Arrester. Bushing CT Ratio: 300-600/1-1-1 A, 0.2S (1 nos), 5P30 (2 nos). PT Ratio: 33000/√3:110/√3:110/√3 V, 0.2 and 3P. Short Circuit Current Capacity: 31.5 kA for 3 sec. For PCM (Integrated with GIS switchgear): (a) Control, Protection, Metering Panel with complete assembly (b) Measuring instruments (0.2s class Programmable energy meter, multifunction meter, Ammeter, Voltmeter etc) and others (c) Control & Protection IEDs (d) All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS).
11 kV Air insulated Switchgear (As per Scope/Brief Description of Works & Technical Specification ).
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling& storage of 11 KV, 2000 A Transformer Incoming Panel comprising 3 phase bus bars 2000 A including 11 KV CT,11 KV Line Potential Transformer (PT), Numerical relay ( Directional O/C & E/F relay & 1 SEF), HV and LV isolating plug and sockets draw out type VCB with auxiliary switches operating mechanism etc. (As per Scope/Brief Description of Works, Technical Specification and GTP). All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS) . CT Ratio: 900-1800/1-1-0.577 A, 0.2S (1 nos), 5P30 (2 Nos). PT Ratio: 11000/√3:110/√3:110/√3 V, 0.2 and 3P Short Circuit Current Capacity: 31.5 kA for 3 sec and IAC AFLR 31.5 KA for 1 Sec.
Installation, testing, commissioning and operation of 11 KV, 2000 A Transformer Incoming Panel comprising 3 phase bus bars 2000 A including 11 KV CT,11 KV Line Potential Transformer (PT), Numerical relay ( Directional O/C & E/F relay & 1 SEF), HV and LV isolating plug and sockets draw out type VCB with auxiliary switches operating mechanism etc. (As per Scope/Brief Description of Works, Technical Specification and GTP). All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS) . CT Ratio: 900-1800/1-1-0.577 A, 0.2S (1 nos), 5P30 (2 Nos). PT Ratio: 11000/√3:110/√3:110/√3 V, 0.2 and 3P Short Circuit Current Capacity: 31.5 kA for 3 sec and IAC AFLR 31.5 KA for 1 Sec.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 11 KV, 2000 A, Bus-Coupler Panel with Bus Riser including 2000 A Bus, 11 KV CT, Numerical Relay and all other accessories as required (As per Scope/Brief Description of Works, Technical Specification and GTP). All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS) and is to be interfaced with the existing/future SCADA system. CT Ratio: 900-1800/1- 1 A, 0.2S (1 nos), 5P30 (1 Nos) PT Ratio: 11000/√3:110/√3:110/√3 V 0.2 and 3P (two-sided bus PT will be used for Sync function) Short Circuit Current Capacity: 31.5 kA for 3 sec and IAC AFLR 31.5 KA for 1Sec
Installation, testing, commissioning and operation of 11 KV, 2000 A, Bus-Coupler Panel with Bus Riser including 2000 A Bus, 11 KV CT, Numerical Relay and all other accessories as required (As per Scope/Brief Description of Works, Technical Specification and GTP). All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS) and is to be interfaced with the existing/future SCADA system. CT Ratio: 900-1800/1- 1 A, 0.2S (1 nos), 5P30 (1 Nos) PT Ratio: 11000/√3:110/√3:110/√3 V
0.2 and 3P (two-sided bus PT will be used for Sync function) Short Circuit Current Capacity: 31.5 kA for 3 sec and IAC AFLR 31.5 KA for 1Sec
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 11 KV, 800 A Line Feeder panels(Outgoing), comprising 3 phase busbars 2000A, including 11 KV CT mounted on outgoing panel with Numerical Relays for IDMT protection, Ammeters, Voltmeters, kWh m, HV and LV isolating plug and sockets draw out type VCB with auxiliary switches operating mechanism etc . All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS) and is to be interfaced with the existing/future TSECL's SCADA system. CT Ratio: 300-600/1-1 A, 0.2S (1 nos), 5P30 (1 Nos) . Short Circuit Current Capacity: 31.5 kA for 3 sec and IAC AFLR 31.5 KA for 1 Sec. ADDITIONAL: 03(three) nos. 11 KV VCB Trolley, 03(three) nos. CTR for 11 KV incomer panel, 03(nos.) CTR for 11 KV outgoing panels and 02(two) set of Spouts shall be supplied along with the Panel.
33 kV Underground Cable and Termination & Copper Bus Bar (As per Scope/Brief Description of Works, Technical Specification and GTP).
Installation, testing, commissioning and operation of 11 KV, 800 A Line Feeder panels(Outgoing), comprising 3 phase busbars 2000A, including 11 KV CT mounted on outgoing panel with Numerical Relays for IDMT protection, Ammeters, Voltmeters, kWh m, HV and LV isolating plug and sockets draw out type VCB with auxiliary switches operating mechanism etc . All circuit breaker's control with Local/ Remote switch and metering data shall be brought under Substation Automation System (SAS) and is to be interfaced with the existing/future TSECL's SCADA system. CT Ratio: 300-600/1-1 A, 0.2S (1 nos), 5P30 (1 Nos) . Short Circuit Current Capacity: 31.5 kA for 3 sec and IAC AFLR 31.5 KA for 1 Sec
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, & storage of Substation Automation System (SAS) and Metering for 11kV Circuits and 33 kV Circuits, LV circuits. Substation Automation System including RTU's, Data Hub, Communication Cable/Fiber Optic, Ethernet Switch (considering Double ring network topology), Workstation, and Graphical User Software etc for Incoming line circuit, Transformer circuit, Bus-coupler and spare bay circuit and all other necessary equipment for successful SAS implementation.
Installation, testing, commissioning and operation of Substation Automation System (SAS) and Metering for 11kV Circuits and 33 kV Circuits, LV circuits. Substation Automation System including RTU's, Data Hub, Communication Cable/Fiber Optic, Ethernet Switch (considering Double ring network topology), Workstation, and Graphical User Software etc for Incoming line circuit, Transformer circuit, Bus-coupler and spare bay circuit and all other necessary equipment for successful SAS implementation.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling , storage, Installation, testing, commissioning and operation of Online UPS System for SAS Panels 3000 VA.
11 kV & 0.415 KV Underground Cable and Termination, Control Cables & Copper Bus Bar (As per Scope/Brief Description of Works & Technical Specification).
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling ,storage, Installation, testing, commissioning and operationof Telecom Equipment (With Panel) with 2 (Two) nos 110V DC to 48V DC Converter with all accessories for Protection and Communication.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 110 V DC Battery Set with Charger and DC distribution panel.
Installation, testing, commissioning and operation of 110 V DC Battery Set with Charger and DC distribution panel.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage, installation, testing, commissioning and operation of 24-core Optical fiber (ADSS) - for physical connectivity with nearest Two substation (Banamalipur SS & Pragati SS).
Installation, testing, commissioning and operation of 24-core Optical fiber (ADSS) - for physical connectivity with nearest Two substation (Banamalipur SS & Pragati SS).
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling , storage, Installation, testing, commissioning and operationof Integration with SCADA, GIS(Geographic Information system), DMS along with FibreFiber Optic Communication System
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling ,storage , Installation, testing, commissioning and operation of Digital Type Exchange with Telephone Sets, ODF (Optical Distribution Frame) for ADSS,Joint Box for ADSS, Patch Cord & Suspension Kit, Tension Kit, Cable Guard, Stainless Steel Strip, Buckle, pole band, preform and vertical extension for Pole to carry ADSS 24 core optical fiber. incl. all accessories and as per TSECL requirement.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 33 kV, 1Cx500 sq.mm XLPE (Cu), Cable. (As per Scope/Brief Description of Works & Technical Specification ). (a). Connection between 33 kV GIS Panel and 33/11 kV Transformer (b).For underground source from overhead source, the mentioned quantity is minimum. If any additional quantity is required shall be provided by contractor.
Laying, commissioning and operation of 33 kV, 1Cx500 sq.mm XLPE (Cu), Cable. (As per Scope/Brief Description of Works & Technical Specification). (a). Connection between 33 kV GIS Panel and 33/11 kV Transformer (b).For underground source from overhead source, the mentioned quantity is minimum. If any additional quantity is required shall be provided by contractor.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage, installation, testing, commissioning and operation of 33 kV Cable termination kit (Indoor/Outdoor types- Cable Size 1Cx500 mm² XLPE (Cu)) along with all accessories for (a) Connection between 33 kV GIS Panel and 33/11 kV Transformer (b) For underground source from overhead source. (c) The mentioned quantity is minimum. If any additional quantity is required shall be provided by contractor.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling ,storage, installation, testing, commissioning and operation of Copper Bus bar minimum (1000 Sq.mm) for 33 & 11 kV side of Power Transformer (For connecting transformer bushing to XLPE Cu Cable). Following facts should be considered- (a) Cross section of Copper Bus bar shall be of minimum size (1000 mm2) or that used for 33 kV transformer incoming switchgear supplied by switchgear manufacturer which is higher. (b) Length will sufficient so that XLPE Cu Cable does not overlap with transformer body & radiator.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 11 kV, 3 C x 95 sq.mm XLPE (Cu), Cable (As per Scope/Brief Description of Works &Technical Specification ). (a) Connection between 11 kV AIS Panel and 11/0.433 kV Auxiliary Transformer. (b) The mentioned quantity is minimum. If any additional quantity is required shall be provided by contractor.
Laying, testing, commissioning and operation of 11 kV, 3 C x 95 sq.mm XLPE (Cu), Cable (As per Scope/Brief Description of Works &Technical Specification ). (a) Connection between 11 kV AIS Panel and 11/0.433 kV Auxiliary Transformer. (b) The mentioned quantity is minimum. If any additional quantity is required shall be provided by contractor.
AC, DC Panel, Battery & Battery Charger (As per Scope/Brief Description of Works & Technical Specification).
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 11 kV 3Cx240 sq.mm XLPE (
Al), Cable (As per Scope/Brief Description of Works & Technical Specification ). (a) Connection between 11 kV AIS Panel and 11/0.433 kV Auxiliary Transformer. (b) The mentioned quantity is minimum. If any additional quantity is required shall be provided by contractor.
Laying, testing, commissioning and operation of 11 kV 3Cx240 sq.mm XLPE (Al), Cable (As per Scope/Brief Description of Works & Technical Specification). (a) Connection between 11 kV AIS Panel and 11/0.433 kV Auxiliary Transformer. (b) The mentioned quantity is minimum. If any additional quantity is required shall be provided by contractor.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage of 11 kV , 1C x500 sq.mm XLPE (Cu)- (VCV/CCV) Power Cable per phase for connection from power transformer to Switchgear. The mentioned quantity is minimum. If any additional quantity is required shall be provided by contractor.
Laying, testing, commissioning and operation of 11 kV , 1C x500 sq.mm XLPE (Cu)- (VCV/CCV) Power Cable per phase for connection from power transformer to Switchgear. The mentioned quantity is minimum. If any additional quantity is required shall be provided by contractor.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage, installation, testing, commissioning and operation of 11 kV Cable termination kit (Indoor/Outdoor types- Cable Size 1Cx500 mm² XLPE (Alu)) along with all accessories for (a) Connection between 11 kV AIS Panel and RMU& Existing Feeder (b) For underground source from overhead source. (c) The mentioned quantity is minimum. If any additional quantity is required shall be provided by contractor.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage, installation, testing, commissioning and operation of 11 kV Cable termination kit (Indoor/Outdoor types- Cable Size 3Cx240 mm² & 3C X 95 mm² , XLPE (Alu)) along with all accessories for (a) Connection between 11 kV AIS Panel and RMU& Existing Feeder (b) For underground source from overhead source. (c) The mentioned quantity is minimum. If any additional quantity is required shall be provided by contractor.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 1.1 KV, 4Cx95 Sq.mm PVC (Cu) Power Cable for Auxiliary Transformer LV Connection with cable termination kit..
Grounding-Mesh
Erection, testing, commissioning and operation of 1.1 KV, 4Cx95 Sq.mm PVC (Cu) Power Cable for Auxiliary Transformer LV Connection with cable termination kit..
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage, installation, testing, commissioning and operation of 11 kV Cable termination kit (Indoor/Outdoor types- Cable Size 4C X 95 mm² , XLPE (Alu)) along with all accessories.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage, installation, testing, commissioning and operation of 33 KV Surge Arrester .
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling , storage, erection, testing, commissioning and operationof All Control cables of different sizes and all LV PVC copper cable of different sizes as necessary and MCCB, connectors to connect different panels/auxiliary transformer etc. 4Cx4 sq.mm, 4Cx6 sq.mm, 4Cx2.5 sq.mm, 8Cx2.5 sq.mm, 14Cx2.5 sq.mm, 16Cx2.5 sq.mm, 19Cx sq.mm etc including all accessories.
Supply, loading, transportation, unloading, insurance, delivery at site, handling ,storage, installation, testing, commissioning and operation of Copper (Cu ) Bus bar for 11 kV side of (including neutral) Power Transformer (For connecting transformer bushing to XLPE Cu Cable). Following facts should be considered- Cross section of Copper Bus bar shall be of minimum size (2000 sq.mm) or as that used for 11 kV transformer incoming switchgear supplied by switchgear manufacturer which is higher Length will sufficient so that XLPE Cu Cable doesn’t overlap with transformer body & radiator.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of AC Distribution Panel with mechanical and electrical interlocking and Bus Tie Scheme including 2(two) nos main incoming LV MCCB
Air Conditioning & Outdoor /indoor Electrification
Installation, testing, commissioning and operation of AC Distribution Panel with mechanical and electrical interlocking and Bus Tie Scheme including 2(two) nos main incoming LV MCCB
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of DC Distribution Panel with interlocking and Bus Tie Scheme
Fire Detection and Extinguishing Equipment
Installation, testing, commissioning and operation of DC Distribution Panel with interlocking and Bus Tie Scheme
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 110V Battery ( Ni-Cd), 200 Ah, 92+ 5 spare Cell, with accessories.
Installation, testing, commissioning and operation of 110V Battery ( Ni-Cd ), 200 Ah, 92+ 5 spare Cell, with accessories.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 110 V Battery Charger (80 Amps) with accessories and supply of recommended spare parts for at least 5years.
Installation, testing, commissioning and operation of 110 V Battery Charger (80 Amps) with accessories and supply of recommended spare parts for at least 5years.
CCTV Camera/ PC / Television etc.
Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage ,installation, testing, commissioning and operation of minimum 185 sq.mm grounding bare copper conductor. Ground Conductor have to be laid surrounding the switch yard area creating a mesh with minimum 0.6 m depth. Actual Shape of mesh, electrode length, depth, conductor dia etc will be according to design calculation. Consider short circuit current 40 KA and allowable person weight minimum 50 KG and step and touch potential as per IEEE or IEC standard and calculation. Earth resistance of whole substation must be below 0.4 ohm (during test) and 0.3 ohm (during calculation) at dry season (As per scope of works & Technical Specification).
Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling ,storage,installation, testing, commissioning and operation of Grounding rod (Earthing electrode, made of copper & Strip) dia 16 mm. Length of grounding rod will be finalized during earth resistance calculation.
3 Way, 11 KV Ring Main Unit
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 33 kV KV outdoor type Surge Arrester including surge Monitor/counter, Supporting Steel Structure and other accessories.
Installation, testing, commissioning and operation of 33 kV KV outdoor type Surge Arrester including surge Monitor/counter, Supporting Steel Structure and other accessories.
36 KV ,800 Amp, DBCR isolator ( with Earth Switch)
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling & storage of 36 KV ,800 Amp , 25 KA, 3-phase DBCR, Isolator with Earth Switch.
Installation, testing, commissioning and operation of 36 KV ,800 Amp , 3-Phase DBCR, 3-Phase, Isolator with Earth Switch
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage, Installation, testing, commissioning and operation of Galvanised Steel Structures for 36 KV ,800 Amp, DBCR isolator ( with Earth Switch)
Supply of Mandatory Spare parts & Testing Equipment
Supply of Mandatory Spare parts, Testing Equipments
Supply of Health and Safety Equipment’s
Supply of 02(two) nos. of Torque wrench ( 20 - 80 Nm) and 02(two) set of fixed spanner & 02(two) set of adjustable spanner of different sizes.
Annual Maintenance Contract
5 year AMC ( Annual Maintenance Contract ) for GIS Sub-station including relevant spare parts & petty materials as and when required
CIVIL WORKS: Design, engg., supply,construction and finishing work of the following (a) G+2 framed control room building ( b) RCC Boundary Wall ( c) RCC road (d) RCC Cable Trench (e) RCC base for Power Transformer , Auxilliary Transformer , RMU & other supporting structures (f) PCC over switch yard
RCC FRAMED G+2 CONTROL ROOM BUILDING
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. -All kinds of soil
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. (All kinds of soil)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms liftupto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.-All kinds of soil
Filling available excavated earth (excluding rock) intrenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil
Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitablemethod complete.
Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage, installation, testing, commissioning and operation of supporting steel column structure connecting the 33 KV & 11 KV power cables with the necessary connecting clamps.
All work upto plinth level: -1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level:- 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - 1:4:8 ( 1 Cement: 4 fine sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 12.5mm/20mm nominal size):- D.P.C. 40 mm thick
Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per 50 kg of cement.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level: I)1 : 1.5 : 3 ( 1 cement : 1.5 fine sand : 3 graded stone aggregate of 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars,piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement (I)1 : 1.5 : 3 ( 1 cement : 1.5 fine sand : 3 graded stone aggregate of 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement:- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
Foundations, footings, bases for columns etc. for mass concrete with timber plank
Walls (any thickness) including attached pilasters,buttresses, plinth and string courses etc. using shuttering ply
Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply
Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply
Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply
Weather shade, Chajjas, corbels etc., including edges.
Stairs (excluding landings) except spiral-staircases with wooden plank
Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.
Edges of slabs and breaks in floors and walls under 20 cm. wide
Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof: Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level.:- Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars
Providing precast cement concrete Jali 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits:-i)50 mm thick
First class brick work in foundation and plinth including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ).
First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:-(i)In Cement mortar 1:4 ( 1 cement : 4 fine sand )
Half brick masonry work with first class bricks in foundation and plinth including cost of all materials as required complete:-i)In Cement mortar 1:4 ( 1 cement : 4 fine sand )
Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-i)In Cement mortar 1:4 ( 1 cement : 4 fine sand )
Extra for providing & placing in position 2 nos 6mm dia MS bars at every 6th course of full brick masonry work including anchorage in joints of 75mm in each side in superstructure for all level including cost of all materials as required complete:-i)In Cement mortar 1:4 ( 1 cement : 4 fine sand )
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :-Karai wood
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.:-35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured)
Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete :- 20 mm dia
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.:-Fixed to openings /wooden frames with rawl plugs screws etc.
Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size)
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :- i)300 x 16 mm
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :-ii)250 x 16 mm
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :- i)300 x 10 mm
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :- ii)250 x 10 mm
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :- i)125 mm
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :- ii)100 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.:- Single rubber stopper
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board including providing and fixing of frame work made of special section power pressed/ role form G.I. sheet with zinc coating of grade 175 consisting of floor and ceilling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick fixed to the floor and ceilling at the spacing of 610 mm centre to centre with dash fastener of 12.50 mm dia- mater, 40 mm length and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceilling channel and placed at a spacing of 610 mm centre to centreb by 6 mm dia bolts and nuts at both ends of partition fixed flush to wall with rawl plugs at spacing 450 mm centre to centre and fixing of boards to either side of frame work by 25 m
Design, Engineering , planning, supply, loa
ding, transportation, unloading, insurance, delivery at site, handling, storage , installation, testing, commissioning and operationof Split type Air Conditioner of 48,000 BTU/Hr including MCB and all other accessories as required.
m drive all screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre, including jointing and finishing to a flush finish with recommended joiunting compound , jointing tape, joint finisher and two coats of primer siutable for boards as per manufacture's specification and direction of the Engineer-In- charge:- 75mm overall thickness partition with 12.5mm thick double skin plain Gypsum board conforming to IS: 2095:part I
Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws.
Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter).
Supplying and fixing rolling shutters of approved make,made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 275mm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters & with handles, hold fast including embedding in cement concrete of required grade required for fixing in position, all necessary fittings, including applying of approved steel primer etc. complete as required:- 80xl.25mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters (exceeding 10 sqm area) of approved make complete as required
Extra for providing & fixing mechanical device chain and crank operation for operating rolling shutters of approved make complete as required:-Exceeding 16.80 sqm in area.
Extra for providing & fixing grilled rolling shutters manufactured out of 8 mm dia. M.S. plain bar instead of laths as per design approved by Engineer-in-charge (area of grill to be measured) complete as required.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., includingwelding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete,including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:- Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm at 100 mm centre to centre and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia. steel pulleys & with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast /anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required.
Providing and fixing circular/ Hexagonal cast iron or M.S.sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape, including painting the exposed portion as per standard drawing complete as required (provided incase of low ceiling height).
Providing and fixing aluminium work for doors, windows, ventilators, stair railing including hand rail and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling to be paid for separately) :-For fixed portion of approved quality:- (i)Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
For shutters/ sliding shutters of doors, windows & ventilators including providing and fixing hinges / pivots / rollers and making provision for fixing fittings wherever required including the cost of PVC / neoprene gasket required of approved quality ( Fittings shall be paid for separately ):- Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition frames with PVC / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge :- With glass/ float glass panes of 5.5 m thickness ( weight not less than 13.50 kg / sqm )
Filling the gap in between aluminium frame and adjacent RCC/brick work by providing weather silicon sealant over backer rod of approved quality etc. complete as per architectural drawing and direction of the Engineer-in charge:- (i) Upto 5 mm depth and 5 mm width.
Providing and fixing aluminium tubular handle bar of 32 mm outer dia, 3.0 mm thick and 2100 mm long with Stainless Steel screws etc. of approved quality complete as per direction of Engineer-in-charge:- Anodised aluminium of grade AC 15 ).
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel: Cladding, with open grooves for linear as
well as curvilinear portions of the building , for all heights and all levels etc. including:- Aluminium Composite Panels of 4mm total thickness with Top coil – 0.50mm AA3003 / AA3105 / AA5005Grade , manufactured as per IS-737 1986, FR Grade Class A2+ with 3mm Alumini um Corrugated Core as per standard EN 13501-1, class A2, and Bottom coil –0.50mm AA3003 / AA3105 / AA5005 Grade manufactured as per IS-737 1986 with minimum 25 microns lead free PVDF Coating conforming to AAMA2605 on top coil and Service coating on Back Coil (4 - 6 microns) having minimum panel weight of 4 Kg/m2
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. all complete as per direction of Engineer-in-charge.
Providing and fixing Kota stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with ordinary cement mixed with pigment of matching shade, including rubbing and polishing etc. all complete as per direction of Engineer-in-charge.:- Kota stone slab 25mm thick
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1 : 3 ( 1 cement : 3 fine sand ) and joined with ordinary cement slurry mixed with pigment to match theshade of slabs, including rubbing and polishing etc. all complete as per direction of Engineer-in-charge.
Providing and fixing precast chequered cement concrete tiles 22 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and polishing complete. :-In dark shade using ordinary cement
Providing and laying polished vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08 % and conforming to IS : 15622 of approved make in all colours, shades over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete.-Soluble Salt Stainfree vitrified tiles:- Size of tile 60x60 cm
Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622 - 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-charge:- Soluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid)
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 ( thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1 : 3 ( 1 cement : 3 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete.:- 450 mm X 300 mm in all shades and design
Providing and laying ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.complete.-Mat Finish Tiles:- Ceramic Tiles 1st quality 300 x 300mm in all shades and designs
Providing and fixing Marble stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with of matching shade, including rubbing and polishing etc. all complete as per direction of Engineer-in-charge-18 mm thick Marble stone:- Agaria White marble.
Design, Engineering , planning, supply, loading, transportation, unloading, insurance, delivery at site, handling , storage ,Installation, testing, commissioning and operation of Outdoor & Indoor Lighting / Electrification.
Providing and fixing gang saw cut of approved thickness mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 ( 1 cement : 4 fine sand ) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing , curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels:- 18 mm thick Granite of any colour and shade duly approved:- Area of slab over 0.50 sqm.
Providing edge moulding to approved thickness marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete at all levels as required as per design approved by the Engineer-in-charge:- 18 mm thick Granite work.
Providing 10mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level over first class wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame etc. complete as perdirection of Engineer-in-charge. (frame work to be paid separately) :- Flat surfaces
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 Type A includingjointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:- Single socketed pipe - 110 mm OD.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:-Coupler:-110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:-Single equal tee with door:-110 x 110 x 110 mm
Providing and fixing on wall face unpl
asticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:- Single equal tee without door:-110 x 110 x 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:-Bend 87.5 degree:-110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:-Shoe plain-110 mm OD
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.:-110 mm
Providing and fixing to the inlet mouth of rain water pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. complete.:- 100 mm
12 mm cement plaster of mix:-Cement mortar 1:4 ( 1 cement : 4 fine sand )
15 mm cement plaster on the rough side of single or half brick wall of mix: In cement mortar 1 : 4 ( 1 cement : 4 fine sand )
6 mm cement plaster of mix :Cement mortar 1:4 ( 1 cement : 4 fine sand )
Neat cement punning.
Applying one coat of water thinnable cement primer of approved brand and manufacturer on wall surface complete:- Water thinnable cement primer
Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:- New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Wall painting with acrylic plastic emulsion paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :- Two or more coats on new work
Applying priming coat [Payment shall be made aftersubmission of Test Certificate issued by theManufacturer:-With ready mixed Pink or Grey primer of approved brand and manufacture on wood work ( hard & soft wood ).
Applying priming coat [Payment shall be made aftersubmission of Test Certificate issued by theManufacturer:- With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel, galvanised iron / steel work.
Painting with synthetic enamel paint ( two or more coats ) of required colour of approved brand and manufacture on new work to give an even shade.
Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with aluminium paint of approved brand and manufacture over a priming coat of ready mixed zinc chromate yellow primer on new work [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:-100 mm diameter pipes
Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with aluminium paint of approved brand and manufacture over a priming coat of ready mixed zinc chromate yellow primer on new work [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:-75 mm diameter pipes
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :-W.C. pan with ISI marked white solid plastic seat and lid
Providing and Fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes espectively with automatic flushing cistern withstandard flush pipe and C.P. brass preaders with brass unions and G.I clamps complete, includingpainting of fittings and brackets, cutting and makinggood the walls and floors wherever required :- One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings andbrackets, cutting and making good the walls wherever require:- White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.:Semi rigid pipe-32 mm dia
Providing and fixing 100 mm sand cast Iron grating for gully trap.
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved 450mm long towel rail with total length of 495mm, 78mm wide and effective height quality and colour.:- 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms.
Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colours weighingnot less than 80 gms.
Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms
Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (workingpressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion:- Single socketed pipe - 110 mm OD
Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (workingpressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion:- Single socketed pipe - 75 mm OD
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:-Coupler-110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:- Coupler-75 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:- Single equal tee without door:-110x110x110mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:- Single equal tee without door:- 75x75x75 mm
Providing and fixing on wall face unp
lasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:- Single equal tee without door:- Single equal tee with door-75x75x75 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:- Single equal tee without door:- Bend 87.5°-110 mm dia
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:- Single equal tee without door:- Bend 87.5°-75mm
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water,soil, waste & vent pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 1cement : 4 fine sand) making good the wall etc. complete-110mm
Providing and fixing to the inlet mouth of rain water,soil, waste & vent pipes pipe PTMT grating with thickness of 8mm and weighing not less than 100gm-100mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability forhot & cold water supply including all CPVC plain &brass threaded fittings including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction ofEngineer in Charge: Internal work - Exposed on wall.-15 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.:Concealed work including cutting chases and making good the walls etc.-15 mm nominal outer dia .Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.:Concealed work including cutting chases and making good the walls etc.- 20 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supplyncluding all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge: External work- 20 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supplyncluding all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge: External work- 40 mm nominal outer dia .Pipes.
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :-25 to 40 mm nominal bore
Providing and fixing brass bib cock of approved quality :-15 mm dia nominal bore
Providing and fixing brass stop cock of approved quality :-15 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):-25 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):-40 mm dia nominal bore
Providing and fixing gun metal non-return valve of approved quality (screwed end): Horizontal-40 mm dia nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:-100 mm dia
Providing and fixing unplastisised P.V.C. connection pipe with PTMT Nuts of approved quality and colour:-15 mm nominal bore with 30cm length.
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.:-20 mm nominal bore. Weighing not less than 40 gms
Cutting holes upto 30x30 cm in walls including making good the same:-With 1st class bricks
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with well burnt 2nd class bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement:3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for single pipe line :
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement:3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets
Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for fire hydrants, with C.I. surface box 350x350 mm. top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design:-With Second Class bricks
Drilling and boring pilot hole in any soil strata by manual means, collection of soil samples of different strata met with during drilling at various suitable levels, preservation of samples in polythene bags / sample boxes and disposal of excess soil or mud, including the cost for water etc. as required to maintain the pilot hole properly as per specification and direction of the Engineer - in - charge.:-100 mm dia
Reaming of pilot hole to an enlarged bore hole in any soil strata by manual means, disposal of excess
soil or mud,including the cost for water etc. as required to maintain the bore hole properly as per specification and direction of the Engineer - in - charge.:-from 100 mm dia pilot hole to 250 mm bore hole
Washing and development of tube well by using hand pump or by any suitable method and testing of the well as per specification and direction of the Engineer - in - charge
Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual means as per specification and direction of the Engineer - in - charge.:-CM' Casing pipe- 100 mm dia
Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual means as per specification and direction of the Engineer - in - charge.:-RS' pipe-100 mm dia
Shrouding of the deep tube well assembly with washed peagravels ( 2.0 - 4.75 mm effective size ) as per specification (IS:4097) and direction of the Engineer - in - charge. ( pea gravels will be supplied from the deptt. free of cost from the stackyards in which the pea gravels are available.)-with contractor's rig
Providing and fixing of UPVC end cap / well cap suitable for UPVC 'CM' casing or 'CS' casing or 'RS' pipes as per specification and direction of the Engineer - in - charge.:-150 mm dia
Providing and fixing of UPVC reducer suitable for UPVC 'CM' casing or 'CS' casing or 'RS' pipes as per specification and direction of the Engineer - in - charge.:-150 x 100 mm dia
Providing and fixing of housing clamp ( made with 12 mm thick MS sheet ) along with well cap (made with 10 mm thick MS sheet ) with necessary arrangements for SBDTW as per specification and direction of the Engineer - in - charge:-150 mm dia
Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS :14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.: Class - 3 ( working pressure 6.0 kg / cm2)-40 mm OD
Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge:-40 mm dia
Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge:-40 x 40 mm dia
Installation of submerssible pump with motor upto the depth of 100 ft by GI pipe ( conforming to IS : 1239 medium class ) with tailpiece as required welded with GI flange in/c providing fitting fixing by necessary rubber washer, nuts & bolts, MS safety clamp etc. as per required size and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run as per direction of the Engineer-incharge (pump, motor with cable will be issued by the Department at free of cost but G.I. pipe of medium class for column assembly will be supplied by the agency at his cost).:- 2500 GPH capacity with 50 / 65 mm dia G.I. pipe and 10 mm thick GI flange
Providing & supply of 2HP Submersible pump motor of KIRLOSKAR/CROMPTON GREAVES make
Sub Heading2
VRV/VRF AC SYSTEM / LAN SYSTEM / IB BASED EPABX SYSTEM/ FIRE FIGHTING SYSTEM / NON-SCHEDULED ITEM(FIRE FIGHTING SYSTEM)
Supplying , Installation , testing and commissioning of VRV/VRF system including indoor/outdoor units, piping, electrical power distribution/wiring, electrical panel , treated fresh air system etc.
Supplying , installation , testing and commisssioning of LAN system comprising of core swithces & L2 switches with 10G , 10 giga SFP modules, wi fi access points , wi fi controller , network management software , racks , CAT 6 A cable , patch panels , OFC etc,( Rate applicable on Plinth Area excluding service/common areas)
Supplying , Installation , testing & commissionig of IP based EPABX SYSTEM comprising of core switches and L2 Switches 10G , 10 giga SFP modules , Industry standard appliance server , cloud based , eneterprise/Grade UC solutions, MID ENTRY level IP/SIP phone with , dual 1 Gig ports, racks , CAT CA cable , patch panels , OFC etc ( Rate applicable on Plinth area excluding service/common areas )
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : i) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. ii) Suitable HP Squirrel cage induction motor, TEFC,Synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. iii) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. iv) Suitable cement concrete foundation duly plastered with anti vibration pads.:- 1620 LPM at 70 m Head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) i) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. ii) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. iii) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. iv) Suitable cement concrete foundation duly plastered with anti vibration pads.:- 1620 LPM at 70 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) i) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. ii) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. iii) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. iv) Suitable cement concrete foundation duly plastered with anti vibration pads.:- 180 LPM at 70 m Head
Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil:- Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Providing, laying, testing & commissioning of 'c' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: All hangers, clamps, brackets etc. shall be of galvanized iron unless specified other wire and then supply of the same shall also be included for rates under this head. Including two coats of synthetic enamel paint of approved shade over a coat of primer. Prior to application of primer the surface should be cleaned for any dirt, rusts, rough substance etc. Including painting of legends both direction arrow as per the approval of the Engineer in charge.:- 80 mm dia
Providing, laying, testing & commissioning of 'c' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: All hangers, clamps, brackets etc. shall be of galvanized iron unless specified other wire and then supply of the same shall also be included for rates under this head. Including two coats of synthetic enamel paint of approved shade over a coat of primer. Prior to application of primer the surface should be cleaned for any dirt, rusts, rough substance etc. Including painting of legends both direction arrow as per the approval of the Engineer in charge.:-100 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :All hangers, clamps, brackets etc. shall be of galvanized iron unless specified other wire and then supply of the same shall also be included for rates under this head. Including two coats of synthetic enamel paint of approved shade over a coat of primer. Prior to application of primer the surface should be cleaned for any dirt, rusts, rough substance etc. Including painting of legends both direction arrow as per the approval of the Engineer in charge.:-200 mm dia (wall thickness 6.3 mm)
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :All hangers, clamps, brackets etc. shall be of galvanized iron unless specified other wire and then supply of the same shall also be included for rates under this head. Including two coats of synthetic enamel paint of approved shade over a coat of primer. Prior to application of primer the surface should be cleaned for any dirt, rusts, rough substance etc. Including painting of legends both direction arrow as per the approval of the Engineer in charge.:-250 mm dia (wall thickness 6.3 mm)
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia.
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :- 80 mm dia
Supplying, fixing, testin
g and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :- 100 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :- 150 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :- 50 mm dia
Providing, installation, testing and commissioning of non return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :- 80 mm dia
Providing, installation, testing and commissioning of non return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :- 100 mm dia
Providing, installation, testing and commissioning of non return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :- 150 mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.:-150 mm dia
Supply, loading, transportation, unloading, insurance, delivery at site, handling , storage , Installation, testing, commissioning and operation of Fire Detection Alarm System for substation building including smoke detection .
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type A) as required: Stainless Steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.: 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585:- 20 mm nominal internal dia gun metal globe valve & nozzle./Drum and brackets for fixing the equipments on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.-40 m
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :-Stainless Steel (Grade 304)
Supply, loading, transportation, unloading, insurance, delivery at site, handling,storage, Installation, testing, commissioning and operation of Trolley mounted fire extinguisher with dry type chemical for A, B and C type fire (15kg.)
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :- 4 way - 150 mm dia M.S. Pipe
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing & fixing GM fire brigade suction hose coupling (draw-out connection) with nut for female coupling as per IS standards complete with 100 mm dia GI suction pipe and 100 mm dia foot valve (to be connected to static tank). Provision of GI drop pipe and foot valve shall be made in all the fire water static storage tanks (2 No) (GI pipe to be paid separately through appropriate item while cost of foot valve to be included).
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing and fixing of Weather proof hose cabinets fabricated from 16 g G.I. Sheet with full glass door and mortise locking arrangement , suitable to accommodate one Hydrant landing valve, 2 nos. 15 M long hose and 1 No branch pipe. The cabinet shall be painted with one coat of primer and finished stove enamelled "Fire Red", "Fire Hose" written on front including suitably mounted on a raised masonry platform as required. (Approx. 0.75mx0.6 m x 0.25 m).
Providing and fixing MS partly glazed single/double hung lockable shutter fabricated from MS section as required with 5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words "Fire Hydrant" written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire man's axe, fire extinguishers 2 nos, including suitably mounted on a raised masonry platform as required. (Approx. Size 0.90 m x 2.1m)
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators suitable for raw water upto 450C temperature working pressure 12 kg and test pressure 20 kg/cm2.:- 100 mm dia
First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:- i)In Cement mortar 1:4 ( 1 cement : 4 fine sand )
Supplying & laying of following 1100 volt grade XLPE insulated PVC sheathed copper conductor armoured cables as per specification in existing trenches, cable trays, ducts, clamped to wall with suitable clamps including providing and fixing of all fixing accessories, connecting, testing and commissioning.:-Power cable 3.5 core 150 sq mm aluminium conductor armoured cable
Filling available excavated earth (excluding rock) intrenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil
Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitablemethod complete.
Power cable 3 core 16 sq mm aluminium conductor armoured cable.
Control cable copper 2 core 1.5 sq.mm
Providing & fixing 150 mm diameter MS Class ‘C’ suitable as per manufacture of diesel engine exhaust pipe (including all fittings, clamps, steel support) of suitable dia for the diesel engine. The pipe shall be provided with 12 mm thick supercera ceramic fibre rope.
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement:- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
Providing, fixing, testing and commissioning of precharged air vessel (size 450 mm dia & 2000 mm height) for pressurization of hydrant system complete with adequate pressure switches (as per design/requirement) with valves to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, 100 mm dia inlet with isolating valve duly painted from inside and outside complete as required.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level.:- Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars
First class brick work in foundation and plinth including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ).
Automatic Fire alarm system
Sub Heading3
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms liftupto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level: 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced
12 mm cement plaster of mix:-Cement mortar 1:4 ( 1 cement : 4 fine sand )
15 mm cement plaster on the rough side of single or half brick wall of mix: In cement mortar 1 : 4 ( 1 cement : 4 fine sand )
6 mm cement plaster of mix :Cement mortar 1:4 ( 1 cement : 4 fine sand )
cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level:- 1 : 1.5 : 3 ( 1 cement : 1.5 fine sand : 3 graded stone aggregate of 20 mm nominal size)
Wall painting with acrylic plastic emulsion paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :- Two or more coats on new work
Centering shuttering including struttings, propping etc. and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank/Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply/Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. -All kinds of soil
Supplying & laying of following 1100 volt grade XLPE insulated PVC sheathed copper conductor armoured cables as per specification in existing trenches, cable trays, ducts, clamped to wall with suitable clamps including providing and fixing of all fixing accessories, connecting, testing and commissioning.:-Power cable 3.5 core 150 sq mm aluminium conductor armoured cable
Filling available excavated earth (excluding rock) intrenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil
Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitablemethod complete.
Power cable 3 core 16 sq mm aluminium conductor armoured cable.
Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer using steel etc. complete as required:-In grating, frames, guard bar, railing, brackets, gates and similar works, all complete
12 mm cement plaster of mix:- i)Cement mortar 1:4 ( 1 cement : 4 fine sand )
15 mm cement plaster on the rough side of single or half brick wall of mix:- In cement mortar 1 : 4 ( 1 cement : 4 fine sand )
Sub Heading4
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. -All kinds of soil
Supplying & laying of following 1100 volt grade XLPE insulated PVC sheathed copper conductor armoured cables as per specification in existing trenches, cable trays, ducts, clamped to wall with suitable clamps including providing and fixing of all fixing accessories, connecting, testing and commissioning.:-Power cable 3.5 core 150 sq mm aluminium conductor armoured cable
Filling available excavated earth (excluding rock) intrenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil
Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitablemethod complete.
Power cable 3 core 16 sq mm aluminium conductor armoured cable.
CONSTRUCTION OF RCC INTERNAL ROAD
CONSTRUCTION OF RCC BOUNDARY WALL
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement:- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level:-1 : 1.5 : 3 ( 1 cement : 1.5 fine sand : 3 graded stone aggregate of 20 mm nominal size)
Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with timber plank
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level. Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars
12 mm cement plaster of mix:-Cement mortar 1:4 ( 1 cement : 4 fine sand )
Brick soling i) Brick edging laid in full brick width: Providing and laying brick edging on prepared subgrade according to lines, grades and cross-section shown on the drawing, filling joints with Earth, free from clay with a Plasticity Index not exceeding 6, watering and rolling the same with three wheeled road roller 80-100 kN as per MoRD Technical Specification Clause 412.
Sub Heading3
CONSTRUCTION OF RCC CABLE TRENCH
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. -All kinds of soil
Supplying & laying of following 1100 volt grade XLPE insulated PVC sheathed copper conductor armoured cables as per specification in existing trenches, cable trays, ducts, clamped to wall with suitable clamps including providing and fixing of all fixing accessories, connecting, testing and commissioning.:-Power cable 3.5 core 150 sq mm aluminium conductor armoured cable
Filling available excavated earth (excluding rock) intrenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil
Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitablemethod complete.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level: 1 : 1.5 : 3 ( 1 cement : 1.5 fine sand : 3 graded stone aggregate of 20 mm nominal size)
Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required
CONSTRUCTION OF RCC BOUNDARY WALL
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars,piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement: 1 : 1.5 : 3 ( 1 cement : 1.5 fine sand : 3 graded stone aggregate of 20 mm nominal size)
Centering shuttering including struttings, propping etc. and removal of form work for :Foundations, footings, bases for columns etc. for mass concrete with timber plank/Walls (any thickness) including attached pilasters,buttresses, plinth and string courses etc. using shuttering ply/Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply
12 mm cement plaster of mix:- i)Cement mortar 1:4 ( 1 cement : 4 fine sand )
First class brick work in foundation and plinth including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ).
Automatic Fire alarm system
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level.: Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars
12 mm cement plaster of mix:-Cement mortar 1:4 ( 1 cement : 4 fine sand )
Brick soling i) Brick edging laid in full brick width: Providing and laying brick edging on prepared subgrade according to lines, grades and cross-section shown on the drawing, filling joints with Earth, free from clay with a Plasticity Index not exceeding 6, watering and rolling the same with three wheeled road roller 80-100 kN as per MoRD Technical Specification Clause 412.
Providing structural steel work in single section fixed with or without connecting plate including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. -All kinds of soil
Filling available excavated earth (excluding rock) intrenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil
Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitablemethod complete.
Sub Heading6
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.81 MB
Tendernotice_2.pdf
PDF • 4.60 MB
BOQ_69326.xls
BOQ • 0.60 MB
Download all tender documents and submit your bid