Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC awarded to L1 | |
| 2 | L2₹9.2 L+₹25,845 (2.90%)Rejected-Finance HYDERABAD | HYDERABAD | TELANGANA | 500001 | L2 | Rejected-Finance AWARDED TO L1 | |
| 3 | L3₹9.3 L+₹35,395 (3.97%)Rejected-Finance | L3 | Rejected-Finance AWARDED TO L1 | |
| 4 | L4₹9.3 L+₹42,219 (4.74%)Rejected-Finance 5 6 NEW ST COLONY N 2 CIDCO CIDCO AURANGABAD AURANGABAD MAHARASHTRA 431005 | AURANGABAD | MAHARASHTRA | 431005 | L4 | Rejected-Finance AWARDED TO L1 | |
| 5 | L5₹10.0 L+₹1.1 L (12.6%)Rejected-Finance G 52 ROOP MANGAL CORNER OF MAIN AVENUE 16TH ROAD SANTACRUZ WEST MUMBAI MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | L5 | Rejected-Finance AWARDED TO L1 |
Tender Value
₹10.2 L
EMD Value
₹20,500
Closing Date
14 Nov 2019, 3:00 pmClosed
AGM EE
Airports Authority of India, Vijayawada Airport
Provision of Flood lighting for Isolation Bay at Vijayawada Airport
2019_AAI_35065_1
AAI/BZ/ENGGE/AGM/NIT10
Open Tender
Electrical Works
Item Rate
60 days
Airports Authority of India, Vijayawada Airport
As per NIT criteria
5 documents required · 5 mandatory
₹1,180
Airports Authority of India
₹20,500
11 Sept 2020
4 Nov 2019
18 Nov 2019
4 Nov 2019
14 Nov 2019
5 Nov 2019
5 Nov 2019 - 8 Nov 2019
Amount
Supply of 1.1KV grade 3.5C 70Sq.mm. armoured aluminium conductor PVC/XLPE insulated and PVC sheathed cable conforming to IS - 1554 (Part - I) 1988/ IS - 7098 (Part - I) 1985 respectively with upto date ammendments.
Supply of 1.1KV grade 4C 10 Sq.mm. armoured aluminium conductor PVC/XLPE insulated and PVC sheathed cable conforming to IS - 1554 (Part - I) 1988/ IS - 7098 (Part - I) 1985 respectively with upto date ammendments.
Supply of integral LED type of 250W Floodlight Luminaire with out put of not less than 25,000 lumens consisting of extruded aluminum housing, Driver with inbuilt protection against surge voltage (upto 4.5KV) open/short circuit and MS mounting bracket etc. with a protection of IP-66 and all accessories etc. complete as required. (Similar to Model no. BENP 20FL Series of Bajaj make ).
Supplying and Laying of 63 mm dia HDPE pipe ISI marked PN4, PE63 along with all accessories like soket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective convering etc. complete as required.
Supplying and Laying of 40 mm dia HDPE pipe ISI marked PN4, PE63 along with all accessories like soket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective convering etc. complete as required.
Supplying and Laying of 40 mm dia HDPE pipe ISI marked PN4, PE63 along with all accessories like soket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct on surface including suitable supporting clamps etc. complete as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size 35 sq.mm to upto 95 sq. mm in the existing RCC/ HUME/ METAL pipe as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size upto 35 sq.mm. in the existing RCC/ HUME/ METAL pipe as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 35 sq. mm and upto 95 sq. mm. in the existing masonry open duct as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size upto 35 sq. mm. in the existing masonry open duct as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Upto 35 sq. mm (clamped with 1mm thick saddle) on wall surface as required.
Supplying and making end termination with brass compression gland for 3.5C 70 Sq.mm. Size PVC/XLPE insulated and PVC sheathed armoured aluminium conductor cable of 1.1kv grade as required.
Supplying and making end termination with brass compression gland for 4C 10 Sq.mm. Size PVC/XLPE insulated and PVC sheathed armoured aluminium conductor cable of 1.1kv grade as required.
Supply, Installation, Testing and Commissioning of MV Switch Board Outdoor Type Sub Feeder Pillar meeting IP 54, Type tested and made out of 3mm thick CRCA Sheet Steel for outer Shell (width not less than 400 mm) and 2mm thick CRCA Sheet for inner partition, dust tight, vermin proof, totally enclosed, cubicle type, floor mounting, free standing suitable for operation at 433 V, 3 Phase, 4 Wire, 50 Hz AC System complete with all accessories, interconnection, connection, earthing, painting, provided with bottom base channel and locking arrangements including excavation for foundation, providing foundation, suitable masonary pedestal up to 45 cm height, fixing of panel etc. complete as required and comprising of the following: a). 100 A, 36 KA, 4P Change over switch Aux contact s ,100/5, class resin cast C.T. operated Digital VAF Meter , ON/OFF/TRIP 3-phase Indication Lamps and Phase Indication Lamps, 6 A-SP MCB-3 numbers, 6 A-TP MCB-1numbers, . including wiring as required as - 1 No. b). 63 A, , 4P panel mounting type socket-1no. c). 32A, 10 KA, 4P MCCB with Micro processor based Releases for OC/SC Protection and ROM , ON/OFF/TRIP Indication Lamps and Phase Indication Lamps as required as outgoing.- 3 sets d). spare compartments for future outgoing - 2 Nos. without swithcgears. e) All accessories such as fuses, auxillary contactors, auxillary switches, etc. as required.
Supply and Installation of 1.5m high 50mm dia GI pipe with 200x200xx10mm GI base plate, 50mm dia breakable couling i/c. providing necessary cement concrete foundation with 150mm x12 dia foundation bolts as per soil conditions with suitable light fixing arrangement at the top and with junction box of Hensel k9500 (210X310X110) or equivalent with 1 No. 4W 16A terminal block and 1 Nos. 2A DP MCB C series with DIN rail etc. compte as required.
Installation, Testing and Commissioning of LED flood light fittings supplied against item No.1 along with all accessories on the perimter 1.5Mtr pole top including connections with 3C 2.5 Sq.mm. PVC insulated PVC sheathed flexible copper conductor cable from junction box to fitting etc. i/c. painting with 2 coats of aviation yellow painting over a coat of red oxide primer complete as required.
Providing and Fixing 6 SWG dia G.I. wire for loop earthing along with existing cable as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc.as required.
Earthing with GI earth pipe 4.5 meter long ,40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangemnt and watering pipe etc. with charcoal/coke and salt as required.
Capart Industries Pvt. Ltd.,
DEEPAKELECTRICALS
GK ELECTRICALS AND ENGINEERS
Kripa Electronics india pvt ltd
Manish Electricals
Shantha ELectricals and Engineers Pvt Ltd
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .