| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC 3RD FLOOR 840 1A CHIRAG DELHI NEW DELHI 110017 CHIRAG DELHI 3RD FLOOR 840 1A CHIRAG DELHI NEW DELHI 110017 SOUTH DELHI SOUTH DELHI DELHI 110017 | SOUTH DELHI | DELHI | 110017 | ₹2.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.2 Cr+₹1.1 Cr (49.5%)Rejected-AOC S N B 4 AP NO 14 KHANDGE HOSPITAL ROAD SHITOLE NAGAR JIJAI NIWAS SANGAVI PUNE MAHARASHTRA 411027 | PUNE | MAHARASHTRA | 411027 | ₹3.2 Cr+₹1.1 Cr (49.5%) | L2 | Rejected-AOC L2 |
| 3 | L3₹3.3 Cr+₹1.1 Cr (53.6%)Rejected-AOC OLYMPIA PLATINA PLOT NO 33B SOUTH PHASE GUINDY CHENNAI 600032 | CHENNAI | CHENNAI | TAMIL NADU | 600032 | ₹3.3 Cr+₹1.1 Cr (53.6%) | L3 | Rejected-AOC L3 |
| 4 | L4₹3.7 Cr+₹1.5 Cr (72.3%)Rejected-AOC 309 SKYLARK BUILDING 309 SKYLARK BUILDING 60 NEHRU PLACE NEW DELHI NEW DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | ₹3.7 Cr+₹1.5 Cr (72.3%) | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹9.3 L
Closing Date
4 Jun 2021, 2:00 pmClosed
CE, ITnC Cell, WBSEDCL
ITnC Cell Vidyut Vhavan Saltlake Kolkata
Comprehensive Annual Maintenance Contract (CAMC) of Critical and Non-Critical Non-IT Infrastructure for Central Data Center Rajarhat and Disaster Recovery Center, Berhampore, WBSEDCL for the period of 3 years
2021_WBSED_330859_1
WBSEDCL/ITnC/33.10(i)/3664 Dated 04.05.2021
Open Tender
Support/Maintenance Service
Turn-key
1095 days
DC and DRC WBSEDCL
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,620
WBSEDCL
₹9.3 L
9 Sept 2021
12 May 2021
9 Jun 2021
12 May 2021
4 Jun 2021
21 May 2021
12 May 2021 - 17 May 2021
Amount
Disel Generator of 625 KVA, Make:- Jackson, Engine:- Cummins, Model:-CJ625D5P (DC)
Disel Generator of 625 KVA, Make:- Jackson, Engine:- Cummins, Model:-CJ625D5P (DRC)
Syncronising-cum-load managing panel of Make :- Woodword (DC)
Syncronising-cum-load managing panel of Make :- Woodword (DRC)
LT Panel of make EAP (Electro allied Products) (DC)
LT Panel of make EAP (Electro allied Products) (DRC)
PAC Panel of make EAP (Electro allied Products) with feeder particulars (DC)
PAC Panel of make EAP (Electro allied Products) with feeder particulars (DRC)
Precision Power Centre for 160 KVA UPS of make Emerson (DC)
Precision Power Centre for 160 KVA UPS of make Emerson (DRC)
A.C. Utility Panel of make :Electro Allied Products (EAP) (DC)
A.C. Utility Panel of make :Electro Allied Products (EAP) (DRC)
Utility Output DB for 10 KVA UPS of make: ABB (DC)
Utility Output DB for 10 KVA UPS of make: ABB (DRC)
LDB for Lighting points of make :ABB (DC)
LDB for Lighting points of make :ABB (DRC)
PDB for Power points of make : ABB (DC)
PDB for Power points of make : ABB (DRC)
1000A FP ATS with overlapping neutral and bypass circuit With BMS Compatibility in an enclosure with double input and single output : Make : Emerson (DC)
1000A FP ATS with overlapping neutral and bypass circuit With BMS Compatibility in an enclosure with double input and single output : Make : Emerson (DRC)
70A FP ATS with overlapping neutral in an enclosure with double input and single output : Make : Emerson (DC)
70A FP ATS with overlapping neutral in an enclosure with double input and single output : Make : Emerson (DRC)
32A DP Push type Starter Switch for Comfort AC units : Make : Schiender (DC)
32A DP Push type Starter Switch for Comfort AC units : Make : Schiender (DRC)
CABLE TRAYS (DC)
CABLE TRAYS (DRC)
POWER CABLES (DC)
POWER CABLES (DRC)
CONTROL CABLES details: 1100V grade multicore PVC insulated and sheathed armoured stranded copper conductor cables (DC)
CONTROL CABLES details: 1100V grade multicore PVC insulated and sheathed armoured stranded copper conductor cables (DRC)
Termination kits for Cable (DC)
Termination kits for Cable (DRC)
Switch, Sockets and wire installed in different lighting points and other electrical points (DC)
Switch, Sockets and wire installed in different lighting points and other electrical points (DRC)
INDUSTRIAL SOCKETS AND HOUSING of Make : Legrand (DC)
INDUSTRIAL SOCKETS AND HOUSING of Make : Legrand (DRC)
Earthing pits with 600 x 600 x 6mm Copper Plate earth upto 10 feet deep with all accessories (DC)
Earthing pits with 600 x 600 x 6mm Copper Plate earth upto 10 feet deep with all accessories (DRC)
160 KVA UPS : Make : Emerson, Model : Hipulse (12 Pulse) HX (DC)
160 KVA UPS : Make : Emerson, Model : Hipulse (12 Pulse) HX (|DRC)
10 KVA UPS : Make : Emerson , Model : 7400 M
10 KVA UPS : Make : Emerson , Model : 7400 M
Precision Air Conditioning (PAC) Units of Libert PeX Model with inert gas based refrigerant in compliance to Kiyoto protocol each of 9.5 TR complete with instruments, gauges, microprocessor controller and other accessories complete for precision air-conditioning of electronic control equipment at data centre (DC)
Precision Air Conditioning (PAC) Units of Libert PeX Model with inert gas based refrigerant in compliance to Kiyoto protocol each of 9.5 TR complete with instruments, gauges, microprocessor controller and other accessories complete for precision air-conditioning of electronic control equipment at data centre (DRC)
Split type non-ductible Refrigeration Unit each of 1.5 TR with Air-cooled condensing unit, room unit, interconnecting refrigerant pipe, protection and temperature & humidity control panel, instruments, gauges and other accessories complete for air-conditioning of electronic control equipment at data centre rooms excepting Server Room and Electrical Room , Make : Bluestar (DC)
Split type non-ductible Refrigeration Unit each of 1.5 TR with Air-cooled condensing unit, room unit, interconnecting refrigerant pipe, protection and temperature & humidity control panel, instruments, gauges and other accessories complete for air-conditioning of electronic control equipment at data centre rooms excepting Server Room and Electrical Room , Make : Bluestar (DRC)
Building Management System : Make : Siemens (DC)
Building Management System : Make : Siemens (DRC)
Integrated Intelligent building management server software having capacity to accomodate points (hardware & software) and more with graphics user interface comprising of the various modules (DC)
Integrated Intelligent building management server software having capacity to accomodate points (hardware & software) and more with graphics user interface comprising of the various modules (DRC)
Field Device (DC)
Field Device (DRC)
ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM (DC)
ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM (DRC)
SAPPHIRE - FIRE SUPPRESSION SYSTEM (DC)
SAPPHIRE - FIRE SUPPRESSION SYSTEM (DRC)
VESDA SYSTEM (DC)
VESDA SYSTEM (DRC)
ACCESS CONTROL SYSTEM (DC)
ACCESS CONTROL SYSTEM (DRC)
WATER LEAK DETECTION SYSTEM & RODENT REPELLENT SYSTEM (DC)
WATER LEAK DETECTION SYSTEM & RODENT REPELLENT SYSTEM (DRC)
CCTV SERVELLIANCE SYSTEM (DC)
CCTV SERVELLIANCE SYSTEM (DRC)
PUBLIC ADDRESS SYSTEM (DC)
PUBLIC ADDRESS SYSTEM (DRC)
Manpower Cost- DC (24*7*365)
Manpower Cost- DRC (24*7*365)
Detailed Hardware breakup to be reffered from Annexure V. Mention GST (%) and HSN/SAC Code Properly
NIRVAA SOLUTIONS PRIVATE LIMITED
Vertiv Energy Private Limited
Nikom InfraSolutions Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .