Executive Engineer, Kachchh Branch Canal Division No.2/3, Adipur
Supply, Installation Erection, testing and Commissioning of Electrical Equipment for Gate Electrification works at Ch.276.857 km of Kachchh Branch Canal
262062
Seconed Trial Tender Notice 10 of 20235
Open
Electrical Works
Works
Kutch
6 documents required · 6 mandatory
₹1,062
Yes
Executive Engineer ,Kachchh Branch Canal, Division No. 2/3, Adipur
₹7,000
Yes
7 Jan 2026
7 Jan 2026
7 Jan 2026
28 Jan 2026
7 Jan 2026
BILL OF QUANTITIES
(A) Percentage Rate Tender (Up to INR 50 Cr.)
Item Description Uom Total Amount
Item Description Uom Total Amount
No. Qty. (without
Supply and installation of powder coated junction box
outdoor type in two compartments made from 2/3 mm
thick M.S.Sheet . The junction box provided with 4 Nos
32 A MCB FP (C & S/ Siemens/ L&T make) & 1 nos
63A 4 pole MCB (C & S/ Siemens/ L&Tmake) complete
with internal wiring 4 sq.mm copper wire & CSTSN
1 Stud type terminal block (Polymide) suitable lugs. All No. 1 11699.042
necessary Accessories including the item. The box shall
be provided with front door hinged at one end and locking
at other end and having bakelite sheet cover inside for
M.C.B. Junction box size to be provided as
per site requirement and mounted on wall or flour with
Rate of supply of Gate Control Panel for 5 HP, 960 RPM,
415 V Induction Motor
Rate for Supply of Local control board for remote
operation of gate from gate structure
Rate for Installation/Erection /Commissioning and testing
of Gate control panel & local control board.
Providing and erecting armoured 12 core x 2.5 s.mm
copper cable multistrand copper conductor for 1.1 KV to
be laid on wall with necessary clamps or in existing
trench/pipe as per site requirement
(Polycab/Universal/Finolex/RR/ OR ISO make
Providing and erecting armoured 3 core x 6 s.mm copper
cable multistrand copper conductor for 1.1 KV to be laid
6 on wall with necessary clamps or in existing trench/pipe Mtr. 200 392.00
as per site requirement (Polycab/Universal/Finolex/RR/
OR ISO make equivelemt) )
Providing and erecting armoured 4 core x 6 s.mm copper
cable multistrand copper conductor for 1.1 KV to be laid
7 on wall with necessary clamps or in existing trench/pipe Mtr. 25 505.00
as per site requirement (Polycab/Universal/Finolex/RR/
OR ISO make equivelemt) )
Providing and erecting armoured 4 core x 2.5 s.mm
copper cable multistrand copper conductor for 1.1 KV to
be laid on wall with necessary clamps or in existing
trench/pipe as per site requirement
(Polycab/Universal/Finolex/RR/ OR ISO make
Contractor Engineer in charge
Point wiring for Light/ Fan primary point with 2 - 1.5 sq.
mm & earth wire of 1.5 sq. mm (Green) both are of ISI
marked 1.1 kv grade FRLS PVC insulated multistrand
copper wires, in with medium class Rigid PVC pipe and
accessories to be erected concealed in/ flushed on wall/
ceiling, complete with 6 A Tissino type ISI marked flush
9 type switch and accessories erected on metal/ PVC box 10 351.00
covered with 3 mm thick PC with medium class rigid
PVC pipe and accessories (Polycarbonate)/ Acrylic sheet
with necessary Lamp holder /Ceiling rose/ H.D connector
as directed/ instructed by Engineer / Site- in -Charge
and as per actual site requirement. (Make :Finolex/
Havells/RR/ Anchor/Hi-Fi)
Point wiring for loopd plug with 16 A Tissino type single
pole ISI mark switch and socket erected with necessary
10 connection erected on wooedn/metal/PVC block covered 10 162.00
with 3 mm thick PC/acrylic sheet for open/conceled
Mains with 1.1 KV grade FRLS PVC insulated ISI
marked stranded copper conductor wire of 2 wire 2.5 sq.
mm with medium class rigid PVC pipe and accessories to
be erected concealed in/ flushed on wall/ceiling, with
sq. mm copper conductor FRLS PVC insulated stranded
wire of green color for earth continuity with medium
class rigid PVC pipe and accessories. (Make :Finolex/
Havells/RR/Anchor)
Supplying and erecting 22-24 watts,surge-2KV,IP-20,4
feet LED indoor fittings with LEDs of wattage 0.2 Watt
to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel
conforming to IS: 513/CRCA powder coated and high
U.V. & corrosion resistance with diffuser and/or
Polycarbonate optics with company mark/name 120 to
300 V, Power Factor more than 0.9, THD < 10 %,CCT
4000 K to 6500K, Uniformity ratio
>0.7,Luminaireefficacy> 100 lumens/watt ,LED driver
efficiency > 85 % CREE / OSRAM / PHILIPS Lumileds /
NICHIA / SEOUL/Bridgelux(U.S.A.) make LED used for
luminaire. ( fitting required LM-79 & LM-80
Certificates.(Cat-III)
Providing & erecting Approved make Power Saving
Watt Ceiling Fan with double ball bearing ISI mark with
13 Condenser 230 volt A.C. 50 Hz 1200 mm sweep No. 2 1929.00
complete having 3blades with aluminium blades with
canopy & 30 cms. down rod erected with earthing.
Supplying & Erecting Galvanized iron pipe post "B"
Class 88.9 mm OD, 4 mtr long duly painted with two
14 coats of aluminuim paint complete with metalic base plate No 3 3194.00
of 300x300x4 mm thickness for using as a compound
light pole with approx weight 32 Kg.
Supplying 50 mm dia.G.I . Pipe & erecting as directed
by Engineer-in-charge.
Supplying & Erecting approved make SMC press
mouldede composite FRP loop in , loop out approx 2mm
thick box complete with bakelite connector strip 4 way &
16 hinged doors having locking arrangements with mounting No 3 510.00
clamp with nuts, bolts & washer suitable for erection on
pole with cable clamps & earth bolt including copper
lugs. Size of box -250 mm x 200 mm x 100 mm (Deep).
Contractor Engineer in charge
Providing M 150/1:2:4 cement concrete foundation &
70% PCC from bottom including excavation for the pole
17 of size 45x45x100 cms Deep in below gound level with No 1 801.00
plinth of 45x45x cms higher upper ground level with
necessary curing and finishing in approved manner.
Providing street light pole Double Arm Bracket
comprising main B Class MS pipe of 4.2 cm/require
outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for
mm / 80mm. / require size pole top having sufficient
18 fastners for fixing the brackets and having spread of 1 No. 3 821.00
mtr. length with suitable rise as per site condition &
suitable welded stiffener reducer and nipple with
check nut complete painted with one coat of Red oxide
/ PU base primer and two coats of Aluminium / PU
Providing and erecting 240 v MCB double pole 6A to
32A switch for lighting Load (B Curve) having 10 KA
breaking capacity & confirms to IS : 8828 in existing
Supplying and erecting above 48 to 60 watts LED
street light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and corrosion
free High pressure die cast aluminum housing with
smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/
lenses .( Street light IP-65 surge protection 4KV
internal and light must have 440 v AC line supply with
over voltage protection ) ( OSRAM / PHILIPS
Lumileds / NICHIA / SEOUL/ BridgeLux (U.S.A.) /ISO
Make LED used for luminaire. [ CAT- III ]
Providing, Erection and connection charges for approved
make, ISI mark (L&T/ Havells/Siemens/ABB) 63 A
21 Triple Pole Metal clad Switch fuse unit 415/500 V with No. 1 3366.00
HRC fuse of suitable load and neutral link (Cat.III) on
new angle iron frame duly painted with red oxide.
Providing and erecting Approved make 63 Amp ELCBs /
RCCBs (cat-III) conforming to IS: 12640 and having
22 sensitivity of 30 mA and Short Circuit withstand capacity No. 1 3010.00
of 10 KA and suitable for operation on 3 phase and
neutral 415V,50Hz.
Work of Cleaning / Servicing / Maintenance / Repairing
23 of Motors, complete followed by inspection and testing No. 3 994.00
for raising and lowering of gates with effective braking .
Work of Cleaning / Servicing / Maintenance / Repairing
of E.M Brake assembly, complete followed by inspection
and testing for raising and lowering of gates with
effective braking.
Provding & erecting roler type limit switch with 1 no +
nc contact ,415 v. having aluminium housing with I.P.55
protection ( /L&T, BCH, siemens, or eqvivalent make
approved by Eng'r.in charge)
Contractor Engineer in charge
Supply of plate /sheet up to 20 mm thick (work as per site
requirement/instruction)
Supply of various size MS angle for gate parts & hoist
maintenance (work as per site requirement/instruction)
Fabrication work including labour,welding,gases,power
28 jigs & fixtures,machinery etc. for job of hoist plateform & MT 0.5 22653.62
Hoist mechanism parts.
Erection charges including labour,welding,gases,power
29 jigs & fixtures,machinery etc. for embeded & Hoist MT 0.5 11479.87
mechanism parts.
30 Rewinding of EM brake coil as per site requirement Set 3 2302.79
Supply and Ereting perforated G.I.cable tray size
200x50x2mm with all necessary accessories for fitting
like coupler S.S. Nut bolt, and cable tray cover with
fabricated GIMS Sheet having thickness 2 mm.
Providing & lying 300 mm Dia RCC Hum pipe for cable
to be laid 90 cms or required depth below ground in Hard
murmur/Tar road across the road crossing or on the floor
with necessary materials in an approved manner and
backfilling the depth of road and making surface as
normal ground level with cement mixtures materials.
Supplying & erecting funnel type earthing having C.I.
earth plate of 45 x 45 x 0.35 cms. burred in specifically
prepared earth pit 3 mtr. below ground with 40 kg.
charcoal and salt with alternate layers of charcoal & salt,
20mm.dia. G.I. pipe with Funnel with a wire mesh for
watering & bricks masonry block, C.I. Cover complete as
per para 7.3 of IS 3043 with necessary length of double
Galvanised Iron / copper earth wire No 6 SWG bolted
with lug to the plate and covered in 12 mm dia. G.I. pipe
2.5 mtr long complete connected to the nearest switch
gear with end socket as per direction & duly tested by
earth tester confirming to IS .
Providing and Erecting required size HOT deep
Galvanised iron strip/8 to 16 SWG/ wire for earthing .
Labour charges for making of Cable trench in Hard
Murrum / Tar Road of suitable width of 90 cm or required
35 depth for laying any size of cable or locating the fault all Mtr. 25 74.00
over the run and back filling the same and making the
surface as normal ground.
Supplying rubber matting of 4 mm thickness and of
36 required length and breadth with good insulation property 6 1017.00
Providing pair of rubber handgloves suitable for working
on 11 KV/22 KV supply.
Supplying standard first AID box with antiseptic
cream,medicine for use on wounds due burn,crepe
bandage,gauge bandage,medicated ready to use (Band-
aid) adhesive tape formed icinaluser ,Scissors, anti-septic
solution (Savlonor similar) etc.(All above contents shall
be of standard makes)
Contractor Engineer in charge
Supplying & erecting D.C.P. Type fire extinguisher of
Kg. capacity cartridge type with gun metal cap 150 gram
CO2 gas cartridge,powder and brackets confirming to ISO
and complete erected on wall .
Transportation charges including loading and unloading
of materials (to and from) to transport the panels,
cables,poles etc all the tender items to caary out the
subjected work of KBC at chainage 276.857 km.
Contractor Engineer in charge
I/We am/are willing to carry out the work at… ...................... % above/below percent (Should
be written in figures and words) of the estimated rate mentioned above. Amount of my /our
tender works out as under.
Estimated amount put to tender Estimated amount put to tender
De Add………% Above
In words In words
(B) For Item Rate Tender (For above INR 50 Cr.):
Item Description of Item Quantity Unit Rate Amount
No. (with brief specification
and reference to book of In In
specifications) figures Words
(A) Total Tendered Amount
(B) Rebate on above tendered amount (if any) % (in figure) ………………………………
(C)Net Tendered Amount (A-B) (in figure) ………………………………
1 The Contractor shall exhibit a board with detailed specification and details of work as
directed by the Engineer-In-Charge for which no extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills
4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per
Govt. G.R.: PRC-10/2017 Cement Consumption/16/C, Date:11/05/2017 as stated in
S.O.R. therefore in R.C.C. items where there is a change as per actual mix design the cost
of difference of cement consumption have been deducted from the rate of original item
at the rate of input rate mentioned in all the tender.
Contractor Engineer in charge
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Seconed Tender Notice No. 10 of 2025-2026 - Copy.pdf
SBD Electrification KBC Ch.276.pdf
BOQ.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .