Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹42.7 L+₹35,854.19 (0.85%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹43.9 L+₹1.6 L (3.67%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹44.0 L+₹1.6 L (3.85%)Rejected-Finance H NO 05 AASI BAUG OPP VATSALYA SCHOOL BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹45.7 L+₹3.3 L (7.84%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹42.3 L
EMD Value
₹84,600
Closing Date
18 Dec 2021, 6:00 pmClosed
GE (AF) BHUJ
GE (AF) BHUJ ,KHAVDA ROAD, BHUJ GUJARAT
CONSTRUCTION OF SERVICE RAMP ALONGWITH SPECIAL REPAIRS TO CERAIN SMQs UNDER AGE BR-I AND AGE BR-II AT AF STN BHUJ
2021_MES_489465_1
8892/V/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BHUJ
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
Yes
GE (AF) BHUJ
₹84,600
Yes
8 Mar 2022
20 Nov 2021
20 Dec 2021
20 Nov 2021
18 Dec 2021
4 Dec 2021
Amount
Demolition including removal of existing damaged, plaster of Column, chajjas, etc including collecting debris on Ground floor External/ Internal )
Providing & fixing of M.S. Support and maintaining the same till the work is over including removal of the same
Corrosion Protection by applying Zink rich primer for protection of Structural steel sections/Steel rebars in two coats at Intervals of 8 hrs. after 24 hrs. of applying of feovert.Primer of Krishna Conchem: I.P. Net RB
M&L for Corrosion IN- Hibitor by providing and applying/Spraying of Concrete penentrating Corrosion in- Hibitor to the concrete surface primer of Krishna Conchem: EPCO-KP-100
M&L for Steel Rebars Fixing by providing, fixing and welding of Tor steel reinforcement where ever required.
M&L for Polymer Repairs (PMM) by applying bond coat of Polymer & Cement (1:1) and making good the broken surface of RCC with Polymer mortar up to original concrete surface including curing etc complete Polymer – APCOGUARD / MONOBOND ( Polymer 1 Ltr : Cement 5 Kg : Quartz Sand 15 Kg )
M&L for rendering 15 mm 1:4 cement plaster in Single coat and including mixing of plasticizer ( Supercon-100) (200ml per bag) &Fibremesh) ( 125gms per bag) in the mortar including curing etc complete
Providing and executing injection grouting with polymer rich cement slury including drilling and nozzles.
Providing and fixing scaffolding for repair of external chhajjas including dismantling.
Providing V groove zari and applying 1:1 polymer : cement coat and filling crack with 1:5:15 mortar
Disposal of Debris of collecting and disposal of Debris from site ( Approximate 7.15 Cum)
Taking down cement plaster on walls etc, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 5 mm thick rendering for fair faces of concrete surfaces on ceiling in CM 1:3 for fair finished surfaces complete all as specified and directed.
M&L for 10 mm thick rendering for fair faces of concrete surfaces on walls in CM 1:6 and finished even and smooth without using extra cement as specified.
M&L for rendering on concrete surfaces 15mm thick in two layers first coat 10mm thick in CM 1:6 and second coat 5mm thick in CM 1:4 with water proofing compound @3% by wt of cement, finished even and fair complete all as specified and directed..
Supply only integral water proofing compound (ISI marked).
M&L for preparation of new or previously untreated concrete extrernal surfaces and applying two coats of exterior emulsion paint all as specified and directed by EIC .
M&L for preparing new plastered ceiling/soffits of chajjas surfaces and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new plastered wall surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over and including one coat of Acrylic putty by finishing the surfaces even and smooth complete all as specified and directed by EIC.
S & F in repair chicken wire mesh with tack screws of galvanized mild steel wire cloth of 0.56 mm nominal dia of wire and average width of aperture 1.18 mm all as spd and as directed
Supply and fix for hard drawn steel wire fabric square mesh of size 50mm square each with 3mm dia wire, weight not less tha 2.2Kg/Sqm confirming to IS : 1586-1982, on the walls, with minimum 10cm lap to sides and end as required complete all as specified in IS 13935 and directed by Engineer-in-Charge. Note :(i) The net area of mesh, as fixed shall be measured without and extra allowance for lap and weight of spikes which shall be included in rates. (ii)Flat iron supports nut, bolt shall be measured and paid separately.
Complete removal of existing treatment on old treated surfaces applying two coat of distemper over a coat of birla putty all as specified and directed
S&F mild steel bolts, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 38Cm long (dia of neck 6mm) Note : Cost of drilling holes for bolts in stone masonary/PCC block masonary shall be included in cost of bolts etc.
Demolition of Precast concrete block walling built in cement mortar
M&L for Precast cement concrete block masonary with solid blocks exc 10cm in width (1:5:8) 20mm graded and setting in cement mortar 1:6 all as specified and directed
Preparation of old wooden painted surfaces of any description exc 10 cm width or girth and appying one coat of synthetic enamel paint, complete all as specified and as directed.
Preparation of old steel painted surfaces of any description exc 10 cm width or girth and appying one coat of synthetic enamel paint, complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) and removing rubbish off the MD land.
Taking up on down steel tubing and connection incl cleaning for refixing of the following bore of pipe
15mm bore of pipe
20mm bore of pipe
25/32/40mm bore of pipe
S&F CPVC pipes ISI marked, IS-15778 with all fittings for hot and cold water, fixed with solvent cement complete to walls and ceilings or laid in floors of following sizes: (SDR-13.5 of Make : Astral or equivalent of Supreme / Finolex)
20mm outer dia of pipes
25mm outer dia of pipes
32mm outer dia of pipes
S&F in repair GI spouts of 40 mm dia pipe , approxly 700mm long in sunken floors including necessary cutting , chipping of walls and making good with PCC 1:2:4 type B0 or cement mortar 1:3 with WPC all as specified and directed
S&F in repair grating doom 125mm dia with waste hole of PTMT (minimum weight 40 grams)
S&F in repair PVC connection 15mm size with PTMT nuts of length 600mm.
Dismantling of cast iron, PVC or reinforced concrete pipes jointed in cement mortar and taking out of trenches, if required all as directed by Engr-in-charge following bore of pipe
100/110mm dia of pipes
75mm dia of pipe
S&F of PVC(SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls complete
110mm dia of pipe
75mm dia of pipe
S&F of PVC junction single 'Tee' equal with door opening, ISI marked, IS-14735, jointed with solvent cement of following sizes
110mm dia of pipe
75mm dia of pipe
S&F PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls of following size : -
75mm bore
110mm bore
S&F PVC (SWR) bends any radius of following sizes :-
75mm bore
110mm bore
S&F in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement with 75mm outlet dia.
S&F PVC (HDPE) pipe of 32mm dia with all fittings and fixed complete to walls and ceiling or laid in floors including taking down of old pipes. Make : Astal
M&L Reinforced cement concrete (design mix M 30) as in Columns, pillars, piers, posts and struts complete all as specified directed.
M&L Reinforced cement concrete (design mix M 30) as in Beams, cantilevers, bressummers,lintels over 1.5m span complete all as specified directed.
M & L for RCC M-30 design mix as in slabs supported on walls ,beams and column in floors, roofs the like complete all as specified directed.
M&L Reinforced cement concrete (design mix M 30) as in Chajjas complete all as specified directed.
M & L Form work for fair finished surfaces of concrete measured flat for sides of pillars, posts, struts, piers, columns and stanchions
M&L for formwork to sides and soffits of suspened slabs such as roof slabs, floor slabs, ladings and similar work, not exc. 200mm thick (horizontal or sloping) finished even and fair.
M&L, Formwork to edges of concrete in roof, chajja etc exc 10cm and n.exc 20cm wide complete all as specified and directed.
Use and waste of formwork, rough finished to flat sides and soffit of floor / roof beams, lintels, cantilivers, shelves etc complete all as specified and directed.
Use and waste of formwork, rough finished to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide.
S&F structural steel (FE 410-W gde-250 )quality B for Joist,channel,angle,or Tee sections,fixed independently,without connecting plates,etc(cut to ordinary lenghths indicated)
S&Ffor TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending sprially for hooping for columns hooking ends and binding with including mild steel wire ( annealed ) not les than 0.90 mm dia complete all as specified and directed.
S&F for TMT bars 6 to 8 mm dia and over cut to length bent to shape required including cranking bending sprially for hooping for columns hooking ends and binding with and including mild steel ( annealed ) not less than 0.90 mm dia complete all as specified and directed.
All asper item No. 72 above but 5 mm dia and over upto and including 10 mm dia in strirrups, spacers and binder complete all as specified and directed. .
Demolition reinforcement cement concrete of any descprition and in any position not otherise specifically provided for complete all as specified and directed.
Taking down existing tarfelt from roof including plaster and remove from site complete all as specified and directed .
M&L, PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in roof kerbs/coping/ bed block / depression complete all as specified and directed.
M&L, 15mm thick rendering in cement mortar 1: 4 on faces of brick work or concrete surfaces with WPC, finished even and smooth W/O using extra cement as in roof. (WPC shall be measured & paid seperately) complete all as specified and directed .
M&L, water proofing treatment on roof and preparing the surfaces to receive WPT treatment , applying cold bituminous primer @ 0.30 ltr / Sqm conforming to IS 3384 applied on plastered surfaces including side walls , followed by a layers of APP based polymeric membrane reinforced with polyster non woven fabric (weighing 3.5 Kg/Sqm(minimum) and 3 mm thick) with mineral finish laid on primed surface by torch application with side overlap 100 mm and ends over laps 150 mm , joints sealed properly as per manufacturers instructions all as specified and directed .
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete including necessary form work etc.complete all as specified.
Taking down existing water proofing tretment on RCC slab / beams with bitumen felt with out damaging structure and removing the debrise outside the MD land and M&L for plaster 15 mm thck on concrete surfaces in cement mortar 1:4 finished even and smooth using WPC @ 3% by weight of cement and preparing the surfaces to recive WPT treatment , applying a coat of bitumenm primer confirm to IS - 3384-1986 @ 0.3 litre per sqm . providing APP modified memrane with non woven polyster reinforcement/mat ( centre core) by tourch application over primed surfaces all as specified and directed by Engr-In- Charge
Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning etc capacity of tank exc 500 and n.exc 1000 ltr complete all as specified and directed.
S & F rotational moulded polythene white water storage tank tripple layared (cylindrical , vertical with closed top , ISI marked , ) hoisted and fixed in position all as specd in SSR Part 1 of capacity 500 ltrs including taking down existing tank also including provision of 20 mm bore ball valves , high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum wt 455 gms)( Make of tank Sintex cat no CCWS 0075-02-TLW or equivalent of makes given in Appendix B to PS Make of ball valve Prayag or equivalent in polytuff as approved by GE
S & F rotational moulded polythene white water storage tank tripple layared (cylindrical , vertical with closed top , ISI marked , ) hoisted and fixed in position all as specd in SSR Part 1 of capacity 750 ltrs including taking down existing tank also including provision of 20 mm bore ball valves , high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum wt 455 gms)( Make of tank Sintex cat no CCWS 0075-02-TLW or equivalent of makes given in Appendix B to PS Make of ball valve Prayag or equivalent in polytuff as approved by GE
S & F rotational moulded polythene white water storage tank tripple layared (cylindrical , vertical with closed top , ISI marked , ) hoisted and fixed in position all as specd in SSR Part 1 of capacity 1000 ltrs including taking down existing tank also including provision of 20 mm bore ball valves , high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum wt 455 gms)( Make of tank Sintex cat no CCWS 0075-02-TLW or equivalent of makes given in Appendix B to PS Make of ball valve Prayag or equivalent in polytuff as approved by GE
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steelsheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including complete all as specifed. (FE-415)
M&L Preparation of New or previously untreated steel Surfaces of anydescription, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, primer complete all as specified.
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
Excavating over areas, n exc 1.5m deep and getting out in hard/dense soil
M&L for RCC (Nominal Mix) Type A1 1:11/2:3 (20 mm graded aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified
M & L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, antilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M&L for Cement concrete (1:3:6) type C1 using 20mm grade stone aggregate for foundation, filling and mass concrete including necessary form work fair finishing to exposed surface complete.
M&L preparing newly Plastered Surfaces of Walls and applying Two Coats of Cement Base Paint over a coat of Alkali Based Primer, complete all as specified and as directed.
M&L for hardcore broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified.
M&L for 100 mm thick Cement concrete Type D2 1:4:8 (40 mm graded graded aggregate) as in floor finishes and pavings.
Cement concrete type B-2, 1:2:4 (40mm graded aggregate) 100mm thick as in floor finished even and smooth without usng extra cement
Returning, fillining in, including, spreading levelling watering and well ramming in layers n.exc 25cm
Removing excavated meterial to a distance n.exc 250m & depositing where directed at a level n.exc 1.5m above the starting point.
Material and labour for point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 Volts grade conforming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20mm dia (external) but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5mm FRLS PVC insulated unsheathed copper earth wire including Suitable for switches and sockets complete all as specified and directed by Engineer-in-Charge.
(a) One light point controlled by one, one way switch single pole
All as per item No. 80.00 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board.
Supply and Fixing in replacement wall mounted decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 20 W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting as per Make Havells Cat No LUMILINEPLUSBS20WLED865SPCSS or equivalent in Orient/Philips/Bajaj/CG/Surya/Polycab all as directed by EIC.
S&F in Replacement ceiling rose surface bakelite 65mm x 50mm three terminal all as specified and directed
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete.
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep complete.
Supply and fix switch socket outlet mutipurpose 2 in 1,5 pin 6 Amps,240 Volts (ISI marked) flush type complete all as specied and directd
S&F Switch piano, single pole one way 5 Amps 240 volt capacity flush type complete.
S&F double door Sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 Single pole and neutral 4 ways with 200 Amp rated bus bar 240 volts powder coated all as specified (Make : Havell's, L&T, Standard, Crompton/Indoasian/Polycab)
S&F MCB/Isolator SPN of 240 Volts 40 Amp capacity, 'C' series, 10 KA in existing DB (Make : Havell's, L&T, Standard, Crompton/Indoasian/legrand)
S&F MCB/Isolator SP of 240 Volts 10 Amp capacity, 'C' series, 10 KA in existing DB (Make : Havell's, L&T, Standard, Crompton/Indoasian/legrand)
Supplying and fixing or passing through pipe,1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed in service connections of size 10 sqmm, 2 core including taking down old UNSV service cable complete all as specified and directed by Engineer-in-Charge.
S & F Tubes, `light grade', galvanised, 25 mm dia for cable protection with all fittings and fixed complete to walls and ceiling or laid in floors/road crossing all as specified.
Meterial and labour for sub main wiring with two runs (two runs measured as one run) of PVC insulated and unsheathed FRLS cable 650/1100 Volts grade, conforming to IS - 1536-1977 multi-stranded 6 sq. mm single core size copper conductor drawn through and including PVC Casing & Capping with accessoriesfixed to wall/ceiling with proper saddles and 6 sq. mm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI marked earth continuity wire complete all as specified and directed.(Note : Two runs of conductor with one run of earth wire and one run of conduit will be measured and paid as one unit)
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal.(f) Testing of earthing.
M/s Pal Builders
BHAVANI PROVISION STORES
Ahmed B Khatri
M/s Bombay Novelty Stores
Gayatri Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .