| 1 | L1₹42.0 LAccepted-AOC PLOT NO 44 SIDDARTH PARK BEHIND ICE FACTORY KODKI ROAD BHUJ PIN 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹43.9 L+₹1.9 L (4.48%)Rejected-Finance | L2 | Rejected-Finance HIGHER BID | |
| 3 | L3₹45.0 L+₹2.9 L (6.96%)Rejected-Finance | L3 | Rejected-Finance HIGHER BID |
| Sl No | Description | Qty | Unit | M/S S. SINGH TRADERS L1 | machine vision plus L2 | Sanjay Enterprise L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. | 311.45 | Cum | 200 ₹62,290 Lowest | 300 ₹93,435 | 270 ₹84,091.5 |
| 2.00 | Excavation in trenches exceeding 1.5m but not exceeding 3.00 m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil all as specified & directed by Engineer-in-Charge. | 54 | Cum | 300 ₹16,200 | 450 ₹24,300 | 240 ₹12,960 Lowest |
| 3.00 | M&L PCC 1:4:8 type D2 (40 mm graded aggregate) in foundation filling and mass concreteetc complete etc.all as specified and as directed. | 14.2 | Cum | 3,500 ₹49,700 Lowest | 4,000 ₹56,800 | 3,800 ₹53,960 |
| 4.00 | M&L for precast cement concrete block masonry with solid blocks of PCC (1:5:8) (using 20mm and 12.5 mm graded stone aggregate in the proportion as directed) exc 10cm in width and set and jointed in Cement Mortar (1:6) complete all as specified and directed. | 62.3 | Cum | 500 ₹31,150 Lowest | 5,000 ₹3,11,500 | 4,800 ₹2,99,040 |
| 5.00 | M&L for Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides of soffits (if any) of foundations and plinth beams and similar work etc; rough finish surfaces complete all as specified and as directed. | 146.6 | Sqm | 500 ₹73,300 | 400 ₹58,640 Lowest | 600 ₹87,960 |
| 6.00 | M&L for Form work to sides of concrete pillars, posts, struts, piers, columns and stanchion etc; rough finish surfaces complete all as specified and as directed. | 142 | Sqm | 500 ₹71,000 | 400 ₹56,800 Lowest | 600 ₹85,200 |
| 7.00 | M&L for Form work to sides and soffits of floor or roof RCC beam sides of lintel beam flat rough finish surfaces to receive the plaster, complete all as specified and as directed. | 178.1 | Sqm | 500 ₹89,050 | 400 ₹71,240 Lowest | 600 ₹1,06,860 |
| 8.00 | M&L for Formwork for chullah hoods, chajjas through and similar items including edges, surface rough finish surfaces to receive the plaster, complete all as specified and as directed. | 5 | Sqm | 500 ₹2,500 | 400 ₹2,000 Lowest | 600 ₹3,000 |
| 9.00 | M&L for Form work to soffits of suspended slabs such as roof slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping), rough finish surfaces complete all as specified and as directed. | 157.1 | Sqm | 500 ₹78,550 | 400 ₹62,840 Lowest | 600 ₹94,260 |
| 10.00 | M&L for Form work to edges of concrete flats, floor and roofs not exceeding 20cm wide (horizontal or sloping), rough finish surfaces complete all as specified and as directed. | 52 | Rm | 500 ₹26,000 | 300 ₹15,600 Lowest | 600 ₹31,200 |
Tender Value
₹44.9 L
EMD Value
₹89,734
Closing Date
25 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY
BHUJ
PROVN OF TRAINING ROOM AT 46 AD REGT AND EXTERNAL SERVICE FOR TOILET AND BATHROOM AT TRAINING CENTER AT MIL STN BHUJ UNDER GE ARMY BHUJ
2025_MES_738445_1
8351
Open Tender
Civil Works
Item Rate
180 days
BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE ARMY
₹89,734
Yes
12 Jan 2026
4 Nov 2025
27 Nov 2025
4 Nov 2025
25 Nov 2025
18 Nov 2025
Amount
Excavation in trenches n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches exceeding 1.5m but not exceeding 3.00 m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil all as specified & directed by Engineer-in-Charge.
M&L PCC 1:4:8 type D2 (40 mm graded aggregate) in foundation filling and mass concreteetc complete etc.all as specified and as directed.
M&L for precast cement concrete block masonry with solid blocks of PCC (1:5:8) (using 20mm and 12.5 mm graded stone aggregate in the proportion as directed) exc 10cm in width and set and jointed in Cement Mortar (1:6) complete all as specified and directed.
M&L for Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides of soffits (if any) of foundations and plinth beams and similar work etc; rough finish surfaces complete all as specified and as directed.
M&L for Form work to sides of concrete pillars, posts, struts, piers, columns and stanchion etc; rough finish surfaces complete all as specified and as directed.
M&L for Form work to sides and soffits of floor or roof RCC beam sides of lintel beam flat rough finish surfaces to receive the plaster, complete all as specified and as directed.
M&L for Formwork for chullah hoods, chajjas through and similar items including edges, surface rough finish surfaces to receive the plaster, complete all as specified and as directed.
M&L for Form work to soffits of suspended slabs such as roof slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping), rough finish surfaces complete all as specified and as directed.
M&L for Form work to edges of concrete flats, floor and roofs not exceeding 20cm wide (horizontal or sloping), rough finish surfaces complete all as specified and as directed.
M&L for providing RCC design Mix M-25 (using 20mm graded stone aggregate) as in foundations, including raft footings, foundations beams, plinth beams, bases of columns etc; complete all as specified and as directed.
M&L for providing RCC design Mix M-25 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc; complete all as specified and as directed.
M&L for providing RCC design Mix M-25 (using 20mm graded stone aggregate) as in beams, lintel up to 1.5m clear span, lintel bands etc; complete all as specified and as directed.
M&L for providing RCC design Mix M-25 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in roof, landings, balconies, canopies and in shelves etc; complete all as specified and as directed.
M&L for providing RCC design Mix M-25 (using 20mm graded stone aggregate) as in chajjas etc; complete all as specified and as directed.
M&L for Reinforcement 10mm dia and over TMT bars cut to length, bent to shape required and binding with MS wire not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Reinforcement 8 to 10mm dia TMT bars cut to length, bent to shape required and binding with MS wire not less than 0.9mm dia in stirrups complete all as specified and as directed.
M&L for carrying out water proofing treatment for roofs in the following stages - (i) Rendering 10mm thick in 1:4 mixed with integral water proofing liquid all as per manufacturer's instructions over concrete surfaces finished even and smooth with out using extra cement. (ii) First coat of bitumen primer confirming to IS 3384 @0.300 Kg/ Sqm over plastered surafces (iii) Second layer of 3.0 mm thick APP modified polymeric membrane with centre core of Single non woven polyster reinforcement and having weight 3 Kg/ Sqm with mineral gravel finish on top complete laid with blown type bitumen grade 85/25 @ 1.20 Kg/ Sqm complete all as specified and as directed.
Supply only integral water proofing liquid ISI marked
Returning,filling in,including spreading,levelling,watering and well ramming in layers not exc 25 cm each layer in hard/dense soil all as specified and directed.
Removing excavated soil n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete wall surfaces in CM 1:4 finished fair and even all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:6 finished even without using extra cement over fair faces of brick work or concrete wall surfaces all as specified and as directed.
M&L for 10mm thick rendering in CM 1:3 on ceiling surfaces finished surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C-2, (40mm graded stone aggregate) as in sub floor, sub bases, floor and paving etc; complete all as specified.
M&L for PCC 1:2:4 type B0 25 mm thick using 12.5mm graded stone aggregates as in sub floors/base floors under tiles as in levelling course etc all as specified and directed.
M & L Hard core, broken to gauge n exc 63 mm broken stone / boulders as in paving/ramp/plinth protection deposited, spread and levelled in layers n exc. 75 mm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and fair without using extra cement including provision of construction joints complete all as specified.
S & F for anodised Aluminium partition/ door frame of size 100 x44 x 1.98mm thick with one or more rebates and shutters pull and push type or side hung type (with or without aluminium sash bars) comprising of top & lock rails of section 115 x 44 x 1.98mm thick, bottom rail of section 150 x 44 x 1.98mm thick and stiles of section 85 x 44 x1.98mm thick including necessary jointing cleat, glazing clip, rubber packing anodized aluminium beading, screws, anodized aluminium fittings or hinges 100mm size with hydrolic door closer, handles 'D' type 125mm, floor door stopper, tower bolts 200mm, sliding door bolt 300mm or mortice lock with 5mm thick tinted glass /pre laminted particle board (Novapan) panel and making good to the disturbed wall surfaces to match existing surface complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall and applying 2 coats of Oil Bound distemper over 1.5mm to 2mm thick wall putty finished to a even and smooth finish over a coat of alkali primer complete all as specifed directed by Engg-in-charge.
Preparing new plastered/ pointed surfaces and material & labour for applying Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
M&L for preparation of new plastered surfaces of ceiling etc. & applying three coats of lime white wash on ceiling complete all as specified.
M & L Steel rolling shutters thickness of laths 1.25 mm , with sufficient ball bearing as per IS standard for smooth functioning of shutter ,including top cover, side channels/member , anchoring rod, hasp and staple etc , gear operated type with bevel gear box and crank handle complete and one shop coat of primer with two coat of synthetic enamel paint erected in position as indicated, complete all as specified and directed by Engg-in-charge.
M&L for Point wiring complete with FR PVC insulated unsheathed , 1100 V grade conforming to IS 694 , 1.5 Sqmm (Norminal area) multistranded ,copper conductor cable drawn through in non metallic rigid PVC conceled/surface conduit medium grade ,minimum 20 mm dia, ISI Marked, with sutaible size of 1 to 8 module metal flush boxes and back plate for mounting of modular switches/socket and regulators and including modular fornt plate with all acessories complete .
(a) One light point controlled by one way one switch SP 5 Amps ,240 V.
(b) One ceiling/exhaust fan point controlled by one way one switch SP 5 Amps, 240 V.
(c) One switch socket outlet 3 Pin, 5 Amps, SP on independent board.
(d) One switch socket outlet 3 Pin, 5 Amps, SP on same board.
All as per the above item No 34 herein before but with 2.5 Sqmm cable for 3 Pin 5/15 Amps switch socket outlet.
S&F modular switch one way 6 Amps , 1 module type complete .
S& f modular socket , 6 Amps , 2/3 pin combined 2 module complete.
S& f modular switch socket combination, 6 Amps / 16 Amps , 2/3 pin combined 2 module complete.
S&F ceiling rose surface backlite 65 x 20mm size three terminal ISI marked complete
Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting upto PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit including as per site requirement and 2 Nos of round or square PVC bolck for fixing of FTL fitting complete all as per directed by Engr-in-charge.
S & F in repairs earth plug and socket, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 volts with and including one MCB, SP, 20A, 240 Volts as per all as specified and directed.
M/L for Sub main wiring with 2 runs of PVC FRLS insulated unsheathed multi stranded single core copper conducter 4 Sqmm drawn through PVC conclead conduit including accessaries with 4sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting up ,all as directed. Note: (a)2 runs of cable and one run earth wire and conduit will be measured as one length. (b) cutting chases in to the wall of any thickness , fixing suitable size conduit and drawing copper conductor and and make odd the disturbed surface to match with the existing surface after pluging the holes complete all as specified and directed.
S&F sheet metal enclosures for distribution board when MCB to be used TPN ( Triplepole and neutral ) 4 way, 415Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door type complete all as specified and directed.
S&F in MCB TPN, 63 Amps,415 Volts, rupturing capacity 10 KA."C" Series complete.
S&F MCB SP, 5 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series complete.
M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.
Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.
(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.
Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
Supplying, Laying, jointing and testing new XLPE insulated, armoured, LT aluminum conductor cable 1100 volts 3.5 core, 35sqmm size, laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed
S & F GI pipe, light grade, of size 40 mm dia including necessary fittings laid in trenches/ fixed on wall/ pole for LT cable protection and complete all as specified and directed for cable protection.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and laying un-reinforced precast concrete cable cover, class LV, Type I flat size 250 x 150 x 40 mm laid dry in trenches over under ground cables.
Supply, laying, connecting, jointing and testing of UPCC sch 40, 50mm dia pipe including joints and fittings as per site like tee, elbow, bend, reducer..etc laid in tenches complete all as specified & directed
Supply, laying, connecting, jointing and testing of UPCC sch 40, 25mm dia pipe including joints and fittings as per site like tee, elbow, bend, reducer..etc laid in tenches complete all as specified & directed
M&L for cutting of existing mainline DI/CI pipe line in position and any size reducing to required length, in position, including supply and fixing all required fittings , dewatering etc,if any involed, complete all as specified and directed
M & L for Construction of new PCC solid Masonary valve chamber of size 900X900 X 900 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets alround over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense/rock soil 3 mm thick MS sheet cover fixed on 50 mm X 50 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified & directed.
supply and fix sluice value 50mm dia PN1.6 including necessary flange , nusts, bolts complete all as specified and directed.
supply and fixUPVC ball valve 25mm dia complete all as specified and directed.
Supply and lay in ground pass through wall and on wall connect test and commission the following XLPE LT armored heavy duty electrical cable with aluminum conductor 1100 V grade of cross sectional area:-
(a) 3.5 C 35Sqmm
(b) 3.5 C 70Sqmm
M&L for supply, install, connecting and commissioning of CPRI approved main LT distribution panel board outdoor type, KIOSK Type, double door, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4wire, 415V, factory made free standing, angle iron 50x50x6mm base frame, dust and vermin proof, cubical type, 3 mm thick CRCA sheet steel for load bearing and 2 mm thick for non load bearing, with anticorrosive coating and finally epoxy polyster powder coating of grey shade fully compartmentalised design etc and comprising of the following.
(b) MCCB 100A Amps three phase , 415 Volt manual operated type with 4 pole microprocessar based rated breaking capacity / making capacity 16 KA short time current with adjustable over current and short circuit capacity Ics=100%Icu.
OUTGOING (a) MCCB ,63 Amps,16 kA at 433V Microprocessor Type with O/L and S/C, protection 4 Pole- 02 Nos(01 working+01 spare)
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supply and fix Stay assembly complete with all accessories as shown in electrical plate no. 1 of SSR Part - I ,1991, using stay rod 16 mm dla including stay wire, loop insulator , stay clamp complete all as specified and as directed. Note Excavation , foundation concrete for the new stay shall be measured and paid separately under respective item of schedule.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables.
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
machine vision plus (BID ID -3486349)
Sanjay Enterprise (BID ID -3487177)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
8351TENDER.pdf
Tender Documents • 0.63 MB
8351PS.pdf
Tender Documents • 0.95 MB
8351LISTOFMAKE.pdf
Tender Documents • 0.24 MB
BOQ_826849.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .