| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.4 LAccepted-AOC GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L-1 | Accepted-AOC Due to lowest | |
| 2 | L-2₹25.0 L+₹3.1 L (14.0%)Rejected-Finance C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L-2 | Rejected-Finance Due to not lowest | |
| 3 | Rejected-Technical VILLAGE BHANADA TEH ABADASA DISTT KUTCH PIN 370645 GUJARAT | KACHCHH | GUJARAT | 370645 | - | Rejected-Technical The firm is not enlisted in required category as per NIT | |
| 4 | Rejected-Technical BANADA TA ABADASA DISTT KUTCH PIN 370 645 GUJARAT | KACHCHH | GUJARAT | 370645 | - | Rejected-Technical The firm is not enlisted in required category as per NIT |
| Sl No | Description | Qty | Unit | Krishna Engineering L2 | AARTI ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Supply & Fix in replacement Display controller of 45 KW capacity Hot Water generator of Make- Rapid Cool all as directed by EIC. | 1 | Each | 24,500 ₹24,500 | 21,470 ₹21,470 Lowest |
| 2.00 | Supply & Fix in replacement Air release valve complete assy suitable for 45 KW capacity Hot Water generator of Make- Rapid Cool all as directed by EIC. | 1 | Each | 13,000 ₹13,000 | 11,770 ₹11,770 Lowest |
| 3.00 | Supply and fix in repairs V-belts type A-23 model suitable for CSU motors for AC plant Make; Fenner/ Dunlop or equivalent | 460 | Each | 280 ₹1,28,800 | 250 ₹1,15,000 Lowest |
| 4.00 | Supply and fix in repairs V-belts type B-62 model suitable for AHU motors for AC plant Make; Fenner/ Dunlop or equivalent | 55 | Each | 650 ₹35,750 | 550 ₹30,250 Lowest |
| 5.00 | Supply and fix in repairs V-belts type A-44 model suitable for AHU motors for AC plant Make; Fenner/ Dunlop or equivalent | 40 | Each | 400 ₹16,000 | 350 ₹14,000 Lowest |
| 6.00 | M&L for top up/ gas charging with refrigerant gas (R-410) for dehumidifier after vacuuming and leak testing including brazing suction/ discharge line and testing complete all as specified and as directed by EIC. | 16 | Kg | 2,200 ₹35,200 | 1,940 ₹31,040 Lowest |
| 7.00 | S&F in replacement rotary / invt type compressor of split type AC 1.5/2 Ton capacity in position, charging of refrigerant gas of required quantity, brazing of discharge and suction line and leak testing complete all as specified and as directed | 4 | Each | 14,000 ₹56,000 | 12,000 ₹48,000 Lowest |
| 8.00 | Running/running capacitor of 35 MFD for dehumidifier all as specified and as directed by EIC. | 8 | Each | 700 ₹5,600 | 500 ₹4,000 Lowest |
| 9.00 | Blower motor of dehumidifier FDNF96, 2 KG,230V, 50Hz all as specified and as directed by EIC. | 2 | Each | 3,500 ₹7,000 | 2,900 ₹5,800 Lowest |
| 10.00 | Fan blade for blower motor of dehumidifier FDNF96, 2 KG,230V, 50Hz all as specified and as directed by EIC. | 3 | Each | 900 ₹2,700 | 700 ₹2,100 Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
12 Mar 2026, 6:00 pmClosed
Garrison Engineer (AF) Naliya No. 1
Garrison Engineer (AF) Naliya No.1
REPAIR AND MAINTENANCE OF CASSET AC CSUS MOTORS AND ASSOCIATED ITEMS AT CERTAIN LOCATION INSIDE TECHNICAL AREA AT AF STN NALIYA
2026_MES_753772_1
8099/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Air Force Station Naliya
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE(AF) Naliya No. 1
₹40,000
Yes
20 Jul 2026
21 Feb 2026
14 Mar 2026
21 Feb 2026
12 Mar 2026
7 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & Fix in replacement Display controller of 45 KW capacity Hot Water generator of Make- Rapid Cool all as directed by EIC. | 1 | Each | 100 | ₹100 |
| 2 | Supply & Fix in replacement Air release valve complete assy suitable for 45 KW capacity Hot Water generator of Make- Rapid Cool all as directed by EIC. | 1 | Each | 10 | ₹10 |
| 3 | Supply and fix in repairs V-belts type A-23 model suitable for CSU motors for AC plant Make; Fenner/ Dunlop or equivalent | 460 | Each | 10 | ₹4,600 |
| 4 | Supply and fix in repairs V-belts type B-62 model suitable for AHU motors for AC plant Make; Fenner/ Dunlop or equivalent | 55 | Each | 10 | ₹550 |
| 5 | Supply and fix in repairs V-belts type A-44 model suitable for AHU motors for AC plant Make; Fenner/ Dunlop or equivalent | 40 | Each | 100 | ₹4,000 |
| 6 | M&L for top up/ gas charging with refrigerant gas (R-410) for dehumidifier after vacuuming and leak testing including brazing suction/ discharge line and testing complete all as specified and as directed by EIC. | 16 | Kg | 10 | ₹160 |
| 7 | S&F in replacement rotary / invt type compressor of split type AC 1.5/2 Ton capacity in position, charging of refrigerant gas of required quantity, brazing of discharge and suction line and leak testing complete all as specified and as directed | 4 | Each | 10 | ₹40 |
| 8 | Running/running capacitor of 35 MFD for dehumidifier all as specified and as directed by EIC. | 8 | Each | 10 | ₹80 |
| 9 | Blower motor of dehumidifier FDNF96, 2 KG,230V, 50Hz all as specified and as directed by EIC. | 2 | Each | 10 | ₹20 |
| 10 | Fan blade for blower motor of dehumidifier FDNF96, 2 KG,230V, 50Hz all as specified and as directed by EIC. | 3 | Each | 100 | ₹300 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
Tender8099.pdf
Tender Documents • 0.75 MB
BOQ_844272.xls
BOQ • 1.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .