Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 47 VED NAGAR COLONY DEORI ROAD AGRA 282 001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹9.4 L | L1 | Accepted-AOC Lowest and Reasonable |
| 2 | L2₹9.9 L+₹45,530 (4.84%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹9.9 L+₹45,530 (4.84%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹10.5 L+₹1.1 L (11.7%)Rejected-Finance | ₹10.5 L+₹1.1 L (11.7%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹11.9 L+₹2.5 L (26.7%)Rejected-Finance | ₹11.9 L+₹2.5 L (26.7%) | L4 | Rejected-Finance Not Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
27 Feb 2021, 6:00 pmClosed
GE Army Bhuj
GE Army Bhuj, Madhapar Road, Bhuj-Kutch, Gujarat- 370 001
REPAIR / MAINTENANCE AND PAINTING OF CEILING FANS, EXHAUST FANS INCLUDING REPAIR / REPLACEMENT OF AC, WATER COOLER, REFRIGERATION ETC AT MIL STN BHUJ
2021_MES_418413_1
8735/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhuj
As Per Tender
7 documents required · 7 mandatory
₹500
GE Army Bhuj
₹20,000
Yes
13 Apr 2021
3 Feb 2021
1 Mar 2021
3 Feb 2021
27 Feb 2021
13 Feb 2021
Amount
Disconnecting , taking down & removing carefully the existing ceiling fan, exhaust fans, wall bracket fans, Pedestal Fans and air circulating fans etc , of any description, any sweep and from any position / locations,sealing cable end, for repairs / servicing / overhauling / painting / numbering etc and hanging / fixing the repaired fans in same position or at position as directed by Engr-in-Charge after , dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades,connecting to existing electric sources with using new 1.5 Sqmm 3 core multistrandd PVC insulated copperwire (FRLS) to required length and testing at site to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation of fans to & from workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Remetaling of motor shaft, polishing and grinding and making to standard size to matching with GM Bush shall be measured and paid for separately under appropriate item of Sch ‘A’ (v) Writing of fan No. and painting of fans shall be measured and paid for separately under appropriate item of Sch ‘A’
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal) as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction including painting of fans of any description (ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan) with applying one coat of synthetic enamel paint (White/grey) by spray machine including preparation of existing decorated surfaces of fans including engraving / painting MES No. on fan in capital letters of height not less than 20 mm on fan body complete as directed for the following Fans:- (a) Rewinding of motor of ceiling fans 1200/1400 mm sweep
All as per Item No. 2 here in above but rewinding of motor of exhaust fans of 300 mm sweep complete all as specified and directed.
All as per Item No. 2 here in above but rewinding of motor of exhaust fans of 375 mm sweep complete all as specified and directed.
All as per Item No. 2 here in above but rewinding of motor of exhaust fans of 450 mm sweep complete all as specified and directed.
All as per Item No. 2 here in above but rewinding of motor of air circulating fan/wall mounting fans of 400mm sweep complete all as specified and directed.
All as per Item No. 2 here in above but rewinding of motor of air circulating fan of 610 mm sweep complete all as specified and directed.
All as per Item No. 2 here in above but rewinding of motor of pedestal fan of 400 mm sweep complete all as specified and directed.
Supply only the following new parts suitable for the ceiling/ exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep :- (a) Supplying only ball bearing No 6201 complete all as specified and directed. Make SKF/NRB/NBC
All as per Item No. 9 here in above but Supplying only ball bearing No 6202 complete all as specified and directed. Make SKF/NRB/NBC
All as per Item No. 9 here in above but Supply only gun metal bushes of any description and size to suit existing motor shaft including remetaling grinding & polishing of fan motor shaft to required shape/size complete all as specified and directed.
All as per Item No. 9 here in above but Supplying only capacitor of capacity 2.5 mfd (PVC body) complete all as specified and directed. Make:-PHILIPS/USHA/BAJAJ/SURYA
All as per Item No. 9 here in above but Supplying only capacitor of capacity 4 mfd (PVC body) complete all as specified and directed. Make:- PHILIPS/USHA/BAJAJ/SURYA
All as per Item No. 9 here in above but Supplying only armature shaft of fans of any description and in any position complete all as specified and directed.
All as per Item No. 9 here in above but Supply only PVC canopy of any description and suitable for any type & any make of fan complete all as specified and directed.
All as per Item No. 9 here in above but Supply only rubber real of suitable size of hanging assembly complete all as specified and directed.
All as per Item No. 9 here in above but Supply only 450 mm long down rod 15 mm dia of MS tube light grade, factory made , painted & duly finished with powder coating of white colour, including necessary holes and threading etc complete all as specified.
Supplying and fixing in repairs capacitor of capacity 2.5 mfd (PVC body) in fans of any description and in any position complete all as specified and directed. Make:-PHILIPS/USHA/BAJAJ/SURYA
Supplying and fixing in repair capacitor of capacity 4 mfd (PVC body) in fans of any description and in any position complete all as specified and directed. Make:-PHILIPS/USHA/BAJAJ/SURYA
S & F in repairs ceiling fan regulator deluxe rotary step type 100 Watt suitable for any type of ceiling fan complete all as specified and directed. Make : Confirming to Cta part No 55502 of Anchor or equilavent of BAJAJ/KHETAN/ORIENT
Labour only for repairing and attending the complaint of Split/WindowAC/ Water cooler/Refrigerator/deep freezer by highly skilled tradesman and carryout minor repair and making functional complete all as specified and directed at site. Note :- (replacement of spare part will be measured and paid separately under appropriate items )
Disconnecnting, dismantling and taking out the non functional Air Conditioner window type/Split type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
Disconnecting, dismantling and taking out the non-functional water coolers of any description, any make and in any position, capacity 40 ltrs to 150 ltrs, including water connections, single phase AC connection, 50 Hz, strip opening, cleaning and servicing of the water cooler with using MAIC-DS solution with and including taking out and replacing unserviceable/defective wiring & damaged/un-serviceable parts, necessary brazing, reassembling water cooler, restoring water supply connections and testing of the water coolers complete as all specified and directed. Note :- (i) The replacement of defective / nonfunctional parts/damaged body portions shall be measured & paid separately as “Supply only” under appropriate item of Sch ‘A’ Part -I and fixing charges for new/ repaired items are deemed to be included under this item. (ii) Burnt out windings, if any, replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ Part-I. (iii) Internal wiring, if any, replaced, shall be measured and paid for separately as 'supply only' of internal wiring kit. (iv) The rates for above items are deemed to include for transportation of Water coolers to & from workshop as approved by Engineer-in-charge for necessary repairs and testing of Water coolers at workshop & replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one. (v) Charging of gas to make up required pressure, if any, shall be measured and paid separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. (vi) Rates quoted by the contractor for this item are also deemed to be included for de-scaling of chilled water pipe line including brazing of damaged portion of pipe line.
Disconnecting and taking out the non-functional Refrigerator/Deep Freezer of any description and in any position, strip opening of Refrigerator/Deep Freezer 165 Ltr. to 490 Ltr. Capacity, cleaning and servicing, taking out un-serviceable / defective parts/spares and internal wiring, replacement of un-serviceable parts/spares like Relay, capacitor, wiring , over load protector, Compressor, inner liner Puff, evaporator, freezer, condenser, Lamp & holders etc. necessary brazing, reassembling and testing all as specified and directed. Note :-(i) Replacement of un-serviceable parts shall be measured paid for separately under appropriate item of sch ‘A’ as supply only but fixing and testing element of the parts replaced / repaired is deemed to be included in this item. (ii) The rates for above items are deemed to include for transportation of Refrigerators to & from workshop as approved by Engineer-in-charge for necessary repairs and testing of Refrigerators at workshop & replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one. (iii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.
S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of window AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas (R-22) & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed. Make, Kirloskar,Tecumsha, Whrilpool
All as per Item No. 25 here in above but for Window AC 2 TR Capacity Make, Kirloskar,Tecumsha & Whrilpool
All as per Item No. 25 here in above but for Split 2 TR Capacity Make, Kirloskar,Tecumsha & Whrilpool
All as per Item No. 25 here in above but for Split 1.5 TR capacity Make, Kirloskar,Tecumsha & Whrilpool
S&F Flame proof compressor sealed unit suitable for 2 TR Capacity for Flame proof AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed. Make, Shriram,Tecumsha, Whrilpool
S&F in replacement of Sealed unit compressor for 40/80 ltrs capacity water cooler including vacuum testing and filling of refrigerant gas to required pressure. Make : Emerson Copland / Carrier/ Bluestar/ Tecumsah
M&L in replacement Sealed unit compressor for 165 ltrs capacity including vacuum testing and filling of refrigerant Gas to required pressure Make : Godrej /Tecumseh / Voltas /Whirlpool/ Emerson / Copland
All as per Item No. 31 here in above but for 220 to 320 ltr capacity
All as per Item No. 31 here in above but for 330 to 490 ltr capacity
M&L for replacment of old unsv starting relay box carefully from window/Split type A/C 1 to 2 TR capacity of any make including making necessary elect connections, (Make - Arvind/Shriram)
All as per Item No. 34 here in above but for water coolers 40 to 150 Ltr capacity (Make Arvind/Shriram)
All as per Item No. 34 here in above but for Refrigerator and deep Freezer any make & type (Make- Renutrol/Hitech)
S&F in replacement over load protector suitable for 1.5 AC/WC 40/80 Ltr capacity Make: Renutral / Shriram/Usha/Keltron or equivalent
All as per item no 37 here in above but for 2.0 Ton AC / 120ltr WC capacity
All as per Item No. 37 here in above but for Refrigerator and Deepfreezer for any size of capacity
S&F Thermostat suitable for A/C, Water coolers, Refrigerators, Make- Kelton/Infass/Renutrol
S & Fix repair Starting capacitor 240 V, Make Kelton/BHEL/Tesla of the following size complete all as specified and as directed for 80 to 100 MFD
S & Fix repair Starting capacitor 240 V, Make Kelton/BHEL/Tesla of the following size complete all as specified and as directed for 100 to 150MFD
S & Fix repair of Running capacitor 240 Volts, Make Epcos,Tesla of following size for 4/6 MFD
S & Fix repair of Running capacitor 240 Volts, Make Epcos,Tesla of following size for 30/36 MFD
S & Fix repair of Running capacitor 240 Volts, Make Epcos,Tesla of following size for 45/50/60 MFD
M&L for charging of refrigerant gas R-22/R-410A complete unit or to make up required pressure in existing air conditioner, window type invertor split AC/hot & cold split AC of any description any capacity any make and in any position complete all as specified and directed complete all as specified and directed.
M&L for charging of refrigerant gas 134A/600A to make up the required pressure in any type refrigerator complete all as specified and as directed.
Disconnecnting and taking out existing defective AC electric motor of any description & in any position of size 1/7 HP to 1/5 HP 230 Volts, strip opening for rewinding and removing to & from workshop for rewinding as apporved by Engr-in-Charge, rewiding with appropriate size copper supper enameled wire as approved incl insulating material such as illuminous paper, leatherized paper , cotton tape, glass sleeving, insulating varnish etc, testing at workshop to the entire satisfaction of Engr-in-Charge, transpotation & fixing the motor at site incl necessary connecting & testing complete all as specified and directed.
S& F in replacement fan motor AC 230 V high speed suitable for split AC 1.5/2 ton for any Make of AC all as specified and directed.
Supply and fix in repair copper made Condenser/Evaporator coil assembly complete suitable for 1.5/2.0 Ton window type/Split type AC unit complete including necessary brazing, welding, pressure and testing etc, replacement of worn out misc items required at site complete all as specified and as directed.
Supply and fix in repair copper made Condenser coil assembly complete suitable for all type Refrigerator complete including necessary brazing, welding, pressure and testing etc, replacement of worn out misc items required at site complete all as specified and as directed.
S&F in replacement Swing motor for indoor unit of Split type AC 1.5/2 Ton capacity all as specified and directed.
S&F in replacement of PCB of electronic circuit complete including display panel, signal receiving slot, display PCB (ie Remote) all as per existing one and suitable for 1.5/2 Ton Window type A/C : Make Blue Star, Videocon, LG, Samsung
All as per item No 53 but for 1.5/2 Ton Split Type A/C Ltr capacity
All as per item No 53 but for Refrigerator any make & type.
M & L for repair of defective electronic components in PCB circuit plate of Window/split type AC /Refrigerator of any model as directed.
Supply and fix in replacement of remote controller unit of Air Conditioner Split Type/Window type of any description any make and in any position 1.5/2 TR capacity
S&F in replacement capillary assembly suitable for 1.5/2 Ton capacity AC Make : SRIRAM/RENUTRAL
S&F in replacement of front cover including grill panel of window type A/C of capacity 1.5 / 2 Ton as per existing one. Make : Blue star / Videocon / Amtrex / GEM or equivalent
S&F in repair of blower motor suitable for 230 volts three speed of Blower motor three speed 1/7HP to 1/5 HP 900 rpm suitable for 230 volts of 1.5/2 TR AC.
Supply and fix in replacement blower motor 1/10 HP, 1350 RPM suitable for Split type AC 1.5/2 Ton out door unit single ended or double ended shaft as per existing one. Make :- AUE/Marathon Electric
S&F in replacement of air filter pad of nylon cleanable/washable type of existing thickness for Split type AC 1.5/2.0 ton Capacity as per existing sample all as specified and directed
S&F in replacement of drain pipe for water Cooler & Split type AC 1.5/2.0 ton Capacity as per existing sample all as specified and directed
M&L for testing of complete existing Window type/Split type AC unit of any description, any make & in any position by vacuum and pressure testing with Nitorgen (N2) and brazing the leakage/damaged copper pipe as required at site and charging of the refrigerant gas to required pressure and testing on completion complete all as directed by Engr-in-Charge. Make:- as per existing make of unit.
Dismantling and taking out exiting defective Copper tubing off Size of any description & in any position and supplying and fixing new copper tubing special annealed pressure copper purity min 99.9% and making flairing at both ends for connections including Brass nut of any size as required and incl insulating material etc and testing complete all as Specified and directed.
Supply and fixing fan blade of any type and any description suitable for motor of any capacity for AC/water cooler/Refrigerator complete all as specified and directed.
Supply and fixing wall mounting stand suitable for Split type AC incl two coat of painting complete all as specified and directed.
S&F in replacement of flare valves for Split type AC 1.5/2.0 ton Capacity as per existing sample all as specified and directed
S&F of workshop cable for lead wire pvc seathed 3 core size 40/0.0076 of multistranded copper conductors for water coolers/ AC, Make Plaza/Havells/Finolex
S&F of workshop cable for lead wire pvc seathed 3 core size 23/0.0076 of multistranded copper conductors for Desert coolers/ refrigerators, Make Plaza/Havells/Finolex
M&L for scrapping out old bubbled paint, cleaning the surface, leveling, spray painting with one coat of synthetic enameled paint over one coat of primer as per existing colour to Water cooler any make and type at site including writing MES/SM/SL No with black enameled paint complete all as specified and directed. Note :- painting will be carried out at site by bringing compressor machine rate quoted deemed to be included complete.
All as per item No 72 but for window/Split type A/C up to 2 TR capacity
Taking out existing damaged/unserviceable copper tube insulation of any description & in any position and supply and fixing new insulation for copper tube of any size complete all as directed .
M&L for Replacement of existing unserviceable / damaged portion of the body of the water coolers i.e. in bottom / top / frame etc. with and including using new, 18 SWG, MS black sheet, cut to size, made to shape and size including necessary mouldings etc and fixing and riveting /bolting with existing parts / portion of the water cooler complete all as specified and directed.
Disconnecting dismanlting and taking out the functional Air Conditioner window type of any description any make and in any position 1.5/2 TR capacity Single Phase 50 HZ and reassembling fixing and testing the dismantled AC in new position complete all as specified and directed Note:- (i) The rate for above items are deemed to include for transportation to any distance inside the Army Area as appoved by Engr-in-Charge (ii) Charging of gas if required shall be measured and paid separatly under appropriate item of schedule `A'
Disconnecting,dismantling and taking out the functional air conditioner split type of any description, any make, and in any poition single/three phase 50 HZ and reassembling, fixing and testing incl installation of AC in new position/location after making necessary cutting/opening in wall and making good to match with the existing surface complete all as specified and directed Note : (i) The rate for above items are deemed to include for necessary servicing, cleaning and testing of indoor/outdoor unit of AC & replacement of necessary unserviceable screws/nuts/bolts/washer/packing's etc with new one brazing of copper pipe & provn of pvc drain pipe of suitable size & length for split AC transpotation to any distance inside the AF area as approved.(ii) Charging of gas in required shall be measured and paid seperatly/under appropriate item of schedule A
M&L for repair of electric wiring, PCB Circuits , relays,contactor etc and replacment of defective wiring of Automatic Voltage Stablizer of 1/2/3/5KVA capacity of any make and carryout minor repair of PCB by changing resistance,condensor,transistor,indicator lamp,2 way switch ,PVC insulating sleeves etc and making functional complete all as specified and directed at site.
Supply and fix in replacement AC electric condenser motor 25 Watt, 230 Volts, 1250 RPM single speed for water cooler complete all as specified and directed Make : AUE / GE
Supply and fix in replacement AC electric condenser motor 30 to 35 Watt, 230 Volts, 930 RPM single speed for water cooler complete all as specified and directed Make : AUE / GE
S&F in replacement NRV suitable for 40/80 Ltr capacity water cooler storage type as per existing Make and Model.
S&F in replacement chromium plated push/lifting cock, 15 mm, made up of brass and suitable for 40/80/150 Ltr capacity storage type water cooler as per existing Make and Model.. Make : JOHNSON/COSMA
Removing the unserviceable condenser fan motor from the Water cooler of 40/80/150 Ltr capacity and M&L for rewinding of condenser fan motor of capacity 1 / 30 or 1 / 32 HP 1350 RPM single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, in position connecting up all including testing and refixing complete all as specified and directed.
M&L for opening body of water coolers, taking out cooling tank to rectifiy leakage of refrigerant tube/condensor and refixing the same after carryout necessary repairs, including leakage test, filling insulation material and clamping with GI strip complete all as specified and directed.
M&L for repairing of foundation/bottom base of water coolers any make & type with suitable size angle iron by welding/screwed/screwed/nutbolts after giving proper shape and making good complete all as specified and directed.
Supply only following new parts suitable for refrigerator of any description, make and capacity 165 ltrs to 490 ltrs:- (a) Freezer door with spring & clamp complete all as specified and as directed. Note :- (i) Make of the parts must be same as per existing Refrigerator (ii) The cost of fixing and testing of spare parts is deemed to be included under Schedule `A' item No.3 Sch A Part IV
All as per Item No. 86 here in above but Pin type / screw type bulb Make : Philips/ Bajaj/ Crompton
All as per Item No. 86 here in above but Chiller tray plastic
All as per Item No. 86 here in above but Refrigerator Freezer coil & freezer coil type / roll bound type for 165 ltrs to 230 ltrs capacity
All as per Item No. 86 here in above but Refrigerator Freezer coil & freezer coil type / roll bound type for 250 ltrs to 360 ltrs capacity
All as per Item No. 86 here in above but Fan motor of frost free for double door refrigerator of capacity 300 to 360 ltrs
All as per Item No. 86 here in above but Freezer box suitable for all type refrigarator
All as per Item No. 86 here in above but Main door gasket magnetic type
All as per Item No. 86 here in above but Bi-metal thermostat of capacity – 5 0 C cut in temperature for 300 to 360 ltrs capacity
All as per Item No. 86 here in above but Freezer defrost Heater
All as per Item No. 86 here in above but Door shelf bin & retainer bar
M&L for repair of desert cooler of any type and capacity and of any make and making necessary replacement of unserviceable and defective items complete all as specified and directed
S&F in replacement of electric pump motor 1/80 HP single phase 230 Volts AC 50 Hz including connecting and testing etc complete suitable for desert cooler. Make of pump : TULLU/AUE/Crompton
S&F in replacement of electric fan motor 230V, AC, 50 HZ, for the following sizes of fans as suitable for desert cooler for 300 mm Sweep Make : Cromoton/AUE/Khaitan/Tullu
S&F in replacement of electric fan motor 230V, AC, 50 HZ, for the following sizes of fans as suitable for desert cooler for 350 mm Sweep Make : Cromoton/AUE/Khaitan/Tullu
S&F in replacement of electric fan motor 230V, AC, 50 HZ, for the following sizes of fans as suitable for desert cooler for 400 mm Sweep Make : Cromoton/AUE/Khaitan/Tullu
S&F in replacement of Swing motor single phase 230 Volts AC 50 Hz including connecting and testing etc complete suitable for desert cooler. Make of motor : TULLU/Bajaj/Crompton
S & F in replacement wood wool /grass pads of approved quality and size alongwith square mesh of any size as required on ground to suit the existing door size of desert cooler.
S &F in replacement of plastic fan blade 3/4 wing suitable for motor 1/8 HP of desert cooler. Make : Crompton or equivalent
S & F in replacement of 5 Amps top 3 pin incl 3 mtr 2.5 Mtr flexible copper wire suitable for desert cooler Make : Anchor Anchor/Cona/Havells
S&F in replacement of control switches set of desert cooler as per existing sample
M&L for making new fan motor base incl with clamps, nut bolts, two coat of painting suitablefor existing type of desert cooler all as specified and directed.
S&F PVC transparent pipe set complete for distribution of water of desert cooler (having droping elbow -3 Nos, distribution 3 way ) as per existing size, including clamping by screw/strip all as specified and directed. Note :- The retreived materials have been mentioned in the Sch of credit in the tender documents in pdf form. The amount of Sch of credit will be deducted offline from the amount of BOQ at the time of acceptance.
M/s Bombay Novelty Stores
M/s Pal Builders
Ashok Electric and Electronics
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .