| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.3 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹22.3 L Quoted ₹23.5 L | 1 | Accepted-AOC AOC |
| 2 | 2₹25.8 L+₹2.2 L (9.55%)Rejected-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹25.8 L+₹2.2 L (9.55%) | 2 | Rejected-Finance NOT L1 |
| 3 | 3₹27.1 L+₹3.6 L (15.3%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹27.1 L+₹3.6 L (15.3%) | 3 | Rejected-Finance NOT L1 |
| 4 | 4₹28.3 L+₹4.8 L (20.4%)Rejected-Finance | ₹28.3 L+₹4.8 L (20.4%) | 4 | Rejected-Finance NOT L1 |
| 5 | 5₹31.9 L+₹8.3 L (35.5%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹31.9 L+₹8.3 L (35.5%) | 5 | Rejected-Finance NOT L1 |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
11 Oct 2022, 6:00 pmClosed
GE ARMY BHUJ
GE ARMY BHUJ
CERTAIN REPAIR/ REPLACEMENT OF LT PANEL BOARD / LT FEEDER PILLAR BOX, MCCB, LIGHTNING PROTECTION AND EARTHING IN MD ACCN AND UNIT AREA UNDER AOR OF GE (A) BHUJ
2022_MES_551444_1
8947
Open Tender
Civil Works - Others
Item Rate
180 days
ARMY AREA BHUJ
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY BHUJ
₹83,000
Yes
21 Dec 2022
12 Sept 2022
12 Oct 2022
12 Sept 2022
11 Oct 2022
28 Sept 2022
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables.
S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
S & F GI pipe, light grade, of size 40 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection .
Disconnecting, taking out, removing old existing unserviceable LT underground cable and Laying, jointing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed of size 2 core 10 sqmm (Note : Cable will be issued under Sch B free for laying only)
All as per item no 8 here in before but of capacity 2 core 16 Sqmm complete all as specified and directed
All as per item no 8 here in before but of capacity 3.5 core 50 Sqmm complete all as specified and directed
All as per item no 8 here in before but of capacity 3.5 core 70 Sqmm complete all as specified and directed
Disconnecting, taking out, removing old existing unserviceable LT underground cable and Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed of size 4 core 16 sqmm
- do- as per Item 12 here in above but of size 3.5 core 25 Sqmm
- do- as per Item 12 here in above but of size 3.5 core 35 Sqmm
- do- as per Item 12 here in above but of size 3.5 core 95 Sqmm
M & L for stainless Steel Nut bolts with double washer suitable sizes and length for Fixing the Aluminium Terminals in the LT Panell Box and taking out the old existing Nuts,bolts complete all as specified and directed
S & F for Digital panel mounted Voltmeter flush mounted case of suitable sizes fixed in the existing LT panel board with internal wiring connection and taking out the old existing VlotMeter complete all as specified and directed
S & F for Digital panel mounted Ammeter flush mounted case of suitable sizes fixed in the existing LT panel board with internal wiring connection and taking out the old existing Ammeter complete all as specified and directed
S & F for LED indicator lamps for phase indication for the existing LT panel board with internal wiring connection and taking out the old existing Indicator lamp complete all as specified and directed
Supply and fix in repiars the following items and disconnecting,taking out the old unserviceable one, including necessary lugs of any size and capacity wherever reqd :-
MCCB Thermal Magnetic release Adjustable type 4 pole 63 Amps 16 KA.
MCCB Thermal Magnetic release Adjustable type 4 pole 100 Amps 16 KA.
MCCB Thermal Magnetic release Adjustable type 4 pole 160 Amps 36 KA.
MCCB Thermal Magnetic release Adjustable type 4 pole 250 Amps 36 KA.
MCCB Thermal Magnetic release Adjustable type 4 pole 400 Amps 36 KA.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flat twin core cable of size 6 Sqmm.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed flat twin core cable of size 10 Sqmm.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron strip 25 X 4 mm , (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ NOTE - The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced with 8mm dia TMT bars @ 150mm C/C both ways, funnel with watering pipe
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 4 mm galvanised iron earth strip complete all as specified and directed
Dismantling of old deteriorated ACSR Conductor , of any size , any type and supply and fix aluminium conductor , steel reinforced (ACSR) , of any size, any type , as per existing one and stringing properly on the insulators and binding with aluminium wire , connectors , jumpers etc complete., Note :- Measurement and payment shall be made by measuring horizontal distance between centres of two adjacent poles and adding 3 % for sag , jointings, jumpers etc.
S&F pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 100mm height and 65mm dia suitable for working pressure upto and including 1100 volts grade for LT lines fixed on poles complete all as specified and as directed.
S&F Shackle type 75mm height and 90mm dia insulator, porcelain, vitreous, white, brown or green including galvanised mild steel strap 31mm X 3mm, insulator bolts 12mm dia with suitable washers and nut, suitable for working pressure upto & including 1100 volts fixed on LT poles complete all as specified and directed.
Dismantling of old unserviceable stay assembly, and Supply and fix Stay assembly complete with all accessories as shown in electrical plate no. 1 of SSR Part - I ,1991, using stay rod 16 mm dla including stay wire. Note :- Excavation , earth work , foundation concrete ,loop insulator, stay clamps, for the new stay shall be measured and paid separately under respective item of schedule.
Testing of lightning conductor earthing with the help of earth tester in presence of users rep presventative and recording the earth results in register duly signed by User Rep complete all as directed.
(a) Copper Bus Bar 150 A rating for 3 Phase and 150 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 160 Amps 36 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 63 Amps 16 KA - 04 Nos (04 No for outgoing)
All as per item no 30 here in before but LT Panel consisting of following items Location : AMN PL
(a) Copper Bus Bar 150 A rating for 3 Phase and 150 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 160 Amps 36 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 63 Amps 16 KA - 02 Nos (02 No for outgoing)
All as per item no 30 here in before but LT Panel consisting of following items:- Location : Single Offrs Accn
(a) Copper Bus Bar 150 A rating for 3 Phase and 150 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 400 Amps 36 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 250 Amps 36 KA - 01 Nos (01 No for outgoing)
(g) MCCB 4 Pole 100 Amps 16 KA - 03 Nos (03 No for outgoing)
All as per item no 30 here in before but LT Panel consisting of following items Location : KS II & 23 Jat CH
(a) Copper Bus Bar 150 A rating for 3 Phase and 150 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 250 Amps 36 KA - 01 Nos (01 No for Incoming)
(f) MCCB 4 Pole 100 Amps 16 KA - 03 Nos (03 No for outgoing)
(g) MCCB 4 Pole 63 Amps 16 KA - 02 Nos (02 No for outgoing)
(a) Copper Bus Bar 150 A rating for 3 Phase and 150 A for Neutral - 01 Set
(b) Digital Voltmeter 0 to 500 V
(d) LED Indication Lamp for 3 Phase - 01 Set
(e) MCCB 4 Pole 63 Amps 16 KA - 01 Nos (01 No for Incoming)
Shree Karni Construction
M/s Bombay Novelty Stores
Sai Ram Electricals and Refrigeration Works
ALBA AC AND REF SERVICES
anand enterprises
Ashok Electric and Electronics
SHUBHAM INTERNATIONAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .