| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹24.4 L+₹1.9 L (8.33%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹24.8 L+₹2.3 L (10.2%)Rejected-Finance PLOT NO 127 3 A RATNASAGAR FLATS SECTOR 19 GANDHINAGAR 382019 | GANDHINAGAR | GANDHINAGAR | GUJARAT | 382019 | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹23.3 L
EMD Value
₹46,600
Closing Date
27 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHUJ
GE (AF) BHUJ ,KHAVDA ROAD, BHUJ GUJARAT-370001
COMPREHENSIVE MAINT B/R AND E/M OF VARIOUS BLDGS LOCATED AT OWSA AND NWSA AND OTHER MISC WORKS UNDER GE (AF) BHUJ AT AF STN BHUJ
2022_MES_542777_1
8617
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BHUJ
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (AF) BHUJ
₹46,600
Yes
10 Nov 2022
2 Aug 2022
29 Aug 2022
2 Aug 2022
27 Aug 2022
14 Aug 2022
8 Aug 2022 - 12 Aug 2022
Amount
Taking out settled soil/broken stone aggregates size exc 40 mm to 65 mm at traverse walls area not exc 1.50 m depth and getting out in any type of soils complete all as specified and as directed by Engineer-in-Charge.
Removing excavated soil to a distance exc. 250 m but n. exc. 500 m and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by Engineer-in-Charge.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick, watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base with excavated material complete all as specified and as directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-in-Charge.
Dismantling plain or corrugated steel sheeting any gauge and any thickness sheets in walls, roof covering etc complete all as specified and as directed by Engineer-in-Charge.
Supply & fix mild steelwork in tubulartrusses/structures of square/round /retangular pipes, rafters, purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. 1161-1979 grade St.-240 including notching, drilling, fitting, rivetting and or welding or connection bolts and nuts, cleats, gusset plates etc complete all as specified and as directed by Engineer-in-Charge.
Supply & fix mild steel for wind tiel for roof including securing bolts including cutting tops to shape as directed, drilling holes and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge.
Supply & fix framed work such as grills, gratings, etc framed, guard bars, railings and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
M&L for expanded metal, not less than 4.00 Kg per SQM, and 25mmX25mm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed by Engineer-in-Charge.
Supply & fix pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-Charge.
Supply & fix pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new or previously un-treated steel and iron surfaces over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over one coat of red oxide or zinc chrome on steel and iron surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of old painted iron surfaces of any description exc 10 cm width or girth and appying one coat of synthetic enamel paint on steel and iron surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new or previously un-treated steel and iron surfaces of any description over 10 cm in width or girth not otherwise described and applying two coat of synthetic enamel paint over one coat of red oxide or zinc chrome on steel and iron surfaces in comouflage complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of plastered or unplastered old decorated external surfaces of walls and applying one coat of exterior emulsion paint in camouflage pattern as approved by the GE complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete unreinforced in ground floors/roof and pavings n.exc 15cm thick (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Demolition of PCC block masonry built in cement mortar complete all as specified and directed by Engineer-in-Charge.
Material & labour for 75 mm thick cement concrete type C-0, 1:2:4 using 20mm graded stone aggregate in sub base etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for 100mm thick PCC 1:2:4,type B1,using 40 mm graded stone aggregate as in hard standings/ pavings including use necessary formwork and finishing concrete topping even and fair without using extra cement and spike rolling to surface or making impressions of expanded metal whilst the concrete is green complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping kerb and the like including weathering slightly rounded or chamfered angles and throating as directed including use of necessary form work complete all as specified and directed by Engineer-in-Charge.
Material & labour for precast cement concrete type C1, (1:5:8) (using 20mm graded stone aggregate) solid block masonry witrh solid blocks, exc. 10 cm in width and setting in mortor (1:4) complete all as specified and as directed.
Material & labour for 15 mm thick rendering for fair faces of brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
Material & labour for 10 mm thick rendering for fair faces of concrete surfaces in CM 1:3 and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
Demolition of reinforced cement concrete in any position complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing precast reinforced cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in cover slabs for drains, man holes etc set in cement mortal (1:6) complete all as specified and directed by Engineer-in-Charge.
Material & labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including crancking, bending spiraly for column & hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
Taking down chowkhat or frames with shutter (without taking off shutters from the frames) exc 1.5 sqm but n.exc 4.00 sqm complete all as specified and directed by Engineer-in-Charge.
Taking down shutter of any description exc 1.0 sqm but n. exc 2.0 sqm complete all as specified and directed by Engineer-in-Charge.
Supply & fix anodised aluminium door shutters (single/double shutter), aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing anodised aluminum snap beading handles in each door, hinges handles anodised snap beading screws hold fast etc. complete all as specified. complete all as specified and directed by Engineer-in-Charge.
Supply & fix anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified complete all as specified and directed by Engineer-in-Charge.
Supply only aluminium anodised grill of approved shape with opening in grill 66mmx80mm (diagonally) or nearest to +5 mm made out of standard aluminium moulded section of size 6mmx7mm complete all as specified and directed by Engineer-in-Charge.
Supply & fix 35mm thick 2nd class hard wood factory made plain framed, paneled shutters (any number of panels), with lock rail and panel of 9mm BWP commercial ply or 12mm veveered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (part-I), kiln seasoned and chemically pressure treated. complete all as specified and directed by Engineer-in-Charge.
Supply & fix 300mmlength of mild steel sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, two on staple plate and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fix 150mm size extruded aluminium alloy handles, fabricated type, complete all as specified and directed by Engineer-in-Charge.
Supply & fix 100mm size Butt hinges, medium weight, cold rolled mild steel, and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply & fix 200mm size Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge.
Supply & fix 140 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge.
Supply & fix In repairs 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete fixed in door complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer on wooden surface complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparing new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparing new plastered ceiling/soffits of chajjas surfaces and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation olf treated surfaces of wall and applying one coat of white wash including removing of nails, making good holes, cracks etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation olf treated surfaces of ceiling and applying one coat of white wash including removing of nails, making good holes, cracks etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for writing letter or figures ( Block, roman , Italic or Indain ) n,exc 30 cm high using synthetic enamel paint with thick paint so that they stand out boldly and solidly without showing signs of brush marks complete all as specified and directed by Engineer-in-Charge.
Material & labour for rendering 15 mm thick in cement mortar 1:4 on brick walls or on concrete surfaces mixing with WPC as per manufactures instructions, plastered surfaces finished fair and even complete all as specified and directed by Engineer-in-Charge. Note :- WPC will be measured and paid as supply only under appropriate item
Supply only integral water proofing compound conforming to IS-2465-1975 and/or as approved complete all as specified and directed by Engineer-in-Charge
Material & labour for cement concrete 1:2:4 (using 12.5 graded stone aggregate) 25 mm thickness as in roof padding after applying/ brushing neat cement slurry @ 3.0 Kg of cement per Sqm and levelling maintaining slope complete all as specified and directed by Engineer-in-Charge
Material & labour for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturers instructions complete all as specified and directed by Engineer-in-Charge (a) Rendering 10 mm thick in cement mortar 1:4, plastered surfaces finished even and smooth. The plastered surfaces shall be cured properly for 7 days by ponding of water over roof. (b) Prapering and cleaning of fully dry plastered surfaces as per IS-3067-1966 (c) Applying bitumen primer conforming to IS-3384-1986 over the cleaned plastered surface @ 0.30 litre per sqm. (d) Applying evenly one coat blow hot bitumen of grade 85/25 @ 1.20 kg per sqm on primed surfaces. (e) Applying a layer of APP based polymeric membrance 3.0 mm thick (mimimum) weighing 3.50 kg per sqm (reinforced) with polyster non-woven fabric weighing not less than 160 grams per sqm by torch application. The overlaps shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (f) Applying one coat of aluminium paint @ 0.10 litre per sqm over APP based polymeric membrane.
Material & labour for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 15 cm long fixed complete all as specified and directed by Engineer-in-Charge
Supply only MS base wheel of dia 100 mm and depth 40 mm long with 2 Nos bal bearing and central pin on each wheel for hanger/BPs door complete all as specified and directed by Engineer-in-Charge
Supply only mild steel top guide roller of dia 100 mm and thickness 50/75 mm, fabricated with nuts and bolts alongwith ball bearing and pin on each roller/pully for hanger/BPs doors complete all as specified and directed by Engineer-in-Charge
Lifting up carefully mechanical means steel hangar/blast pen door leaf of size area n exc 40 sqm each, inspecting the parts/members of doors, including repairs, welding as required, removing unserviceable membbers, unserviceable pully/base wheels/top roller/nut bolt etc and fixing only new parts/members as mentioned herein before, fixing steel door back in same position after proper servicing & greasing for smooth noise-less movement/operation of doors complete all as specified and directed by Engineer-in-Charge Note:- Supply only spare parts to replace unserviceable members, nuts, bolts, wheel, rollers etc shall be measured and paid separately.
Easing, adjusting, cleaning of rails, greasing of base wheels and top guide wheel of hanger/BP door leaf having area not less than 40 sqm each and height not exc 10 m including minor repairs, welding adjusting base wheel and top rollers etc to make the sliding door leaf noise-less smooth operation complete all as specified and directed by Engineer-in-Charge
Welding only exc 2.50 cm but n exc 5 cm in length, thickness ofmetal to be welded exc 6 mm but n exc 9 mm sheets/plates/any other steel members, including cleaning and preparing the surfaces while welding and bevilling of edges as required complete all as specified and directed by Engineer-in-Charge
Supply & fix in repairs anti bird proofing net of polyester wooven of aperture size 20mmx20mmx2mm thread (garpil) at a height of 12 m complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable point wiring of any description complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable Flame proof lights complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable Flame proof DBs/ switches complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable SPN DB with MCBs complete all as specified and directed by Engineer-in-Charge.
Material & labour for point wiring complete with 1.5 sqmm single core multi stranded copper conductor FRLSH PVC insulated but unsheathed cable 1100 volts grade drawn through and including rigid steel ERW conduit of 25 mm dia (external) heavy duty including necessay flame proof /weather proof conduit accessories and fitting concealed in wall/ceiling etc including sealing threaded jointsin conduit accessories with teflon tape including 1.5 sqmm single core FRLSH PVC insulated but unsheathed multistranded copper conductor cable as in continuous earth.Wiring shall be suitable for flame proof area as per STEC-7 for the followings:-
One flame proof light point controlled by one,single pole flame proof switch complete all as specified and directed by Engineer-in-Charge.
One flame proof fan point controlled by one,single pole flame proof switch complete all as specified and directed by Engineer-in-Charge
Supply and fixing LED light fitting 2X16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement Flame proof and weather proof rotary type switch,16 Amps,230 Volts,AC single pole, (LM-6) aluminium alloywith flame proof cable entry glands CMRS certified,ISI marked complete all as specified and directed by Engineer-in-Charge
M&L for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through and including ERW conduit of 25 mm dia (external) heavy duty ISI marked with accessories and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engineer-in-Charge .(Note: Two runs of conductor with one run of earth wire and ERW conduit will be measured & paid as one unit)
Supply & fix in replacement double door Sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 Single pole and neutral 8 ways with 200 Amp rated bus bar 240 volts powder coated complete all as specified and directed by Engineer-in-Charge
Supply & fix MCB/Isolator SPN of 240 Volts 63 Amp capacity, 'C' series, 10 KA in existing DB complete all as specified and directed by Engineer-in-Charge.
Supply & fix MCB/Isolator SP of 240 Volts 6-40 Amp capacity, 'C' series, 10 KA in existing DB complete all as specified and directed by Engineer-in-Charge.
Supply & fix MCB DB cover made up of GI sheet of dimensions 45cmX 45 cm with suitable hinges and painting it with matching colour complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement flame proof/ weather proof DB consisting of 01 Nos 32 Amp MCB and 02 Nos 16 Amp MCB with copper busbar, cable entry glands, Class I & II complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement flame proof/ weather proof DB consisting of 01 Nos 100 Amp MCCB in box with copper busbar, cable entry glands, Class I & II complete all as specified and directed by Engineer-in-Charge.
Taking down existing window AC of any capacity and covering the existing hole with PCC complete all as specified and directed by Engineer-in-Charge. (Note :- 02 Nos window AC to be deposited in AGE E/M sore yard)
Supply, install & testing air cooled split unit Air Conditioner 100% Copper condenser & copper evaporator electric driven single Phase of capacity of 1.5 TR indoor & outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating (as per 2019 BEE rating) including MS stand for outdoor unit, suction and delivery line copper material of suitable length as per site requirement complete including flexible copper cable 3 core 2.5 Sqmm appx 2 M, PVC drain pipe 20mm dia approx 3 RM of including making holes to existing wall to draw cable and pipes to connect the indoor unit to the out door unit including provision of extra copper tubing/ hoses etc and making good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, wall mounted type single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with low and high cutoff facility including under and over current protection with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable LT cables from trenches/ducts etc of of any size complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable PVC insulated cables from trenches/ducts/ Walls etc of any size complete all as specified and directed by Engineer-in-Charge.
Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 25 sqmm, 2.0 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6.0 sq. mm 4.0 core nominal cross section connection for siren complete all as specified and directed by Engineer-in-Charge.
Supply & fix 1.0 sqmm 4 core communication cable and proper routing by making suitable hole in existing wall to pass the cable to other end complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches n.exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth and getting out soft / loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25 cm thick in soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by Engineer-in-Charge.
Material & labour fo sand cushioning for UG cables using dry river sand; gently punning down complete all as specified and directed by Engineer-in-Charge. ( Note : For measurement purpose punned thickness shall be considered)
Supply and laying unreinforced precast concrete cable cover,classLV type 2 with flat size 300mm x 180mm x 40mm complete all as specified and directed by Engineer-in-Charge.
Supply & fix of tubes light grade of 50 mm bore galvanised with all fitting for cable protection trenches/ wall/ on pole including necesarry clamps sets and nut & bolts complete all as specified and directed by Engineer-in-Charge.
Supply & fix 250 Ltrs Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engineer-in-Charge.
Supply & fix GI tubing 25 mm bore, medium grade, ISI marked, with and including all fittings such as bends, elbows, tees, short pices etc compelete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
Cutting & screwing extg steel tubing of size 25 mm dia for alterations or additions or lengthening screw on pipe to form connector and done in position complete all as specified and directed by Engineer-in-Charge.
Supply & Fix Gun-metal, globe or gate valves 25mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Supply and laying in repalcement of 20mm outer dia CPVC pipes SDR 11 including plain CPVC fittings on walls/ceiling or laying in floors complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement of 15mm bore bib taps ISI marked cast copper alloy fancy type chroumium plated with crutch butterfly handle screw down for iro n pipe or brass ferrule complete all as specified and directed by Engineer-in-Charge.
Supply and fixing single pointed air termination aluminium rod, 12 mm dia, 300 mm longcomplete all as specified and directed by Engineer-in-Charge.
Supply and fixing single pointed air termination copper rod, 12 mm dia, 300 mm long.complete all as specified and directed by Engineer-in-Charge.
Taking down old Al strip of any size from pole / walls complete all as specified and directed by Engineer-in-Charge.
Supply and fixing aluminium strip 25 mm X 3.15 mm complete with saddles and fixing screws for roof conductors and down conductors above ground. complete all as specified and directed by Engineer-in-Charge.
Supply and fixing copper strip 20 mm X 3.15 mm complete with saddles and fixing screws for roof conductors and down conductors above ground. complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron strip 25X4mm as earthing lead by means of nut, bolts, check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge. including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed by Engineer-in-Charge. (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed by Engineer-in-Charge.. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Earthing complete with copper earth plate electrode 60 cm x60 cm x 3.15 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including copper strip 20X3mm as earthing lead by means of nut, bolts, check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed by Engineer-in-Charge (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply & fix test point terminal block made of gunmetal or phospohorus bronze size 75 x75x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screws complete all as specified and directed by Engineer-in-Charge.
Material & labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate for foundation of stay assembly, pole and struts etc complete all as specified and directed by Engineer-in-Charge
Material & labour for plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate for foundation of stay assembly, pole and struts etc complete all as specified and directed by Engineer-in-Charge.
Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole) Prestressed concrete pole , 11 m long , minimum cross section 152mm x 152mm at top and minimum cross section 152x260 at bottom, class 9 erected in true vertical position complete all as specified. Note:- Excavation and earth work PCC in foudation, plinth block/ coping cross arms, bracing clamp for strut poles etc shall be measured and paid seperately complete all as specified and directed by Engineer-in-Charge.
Sanjay Enterprise
divyarsh entrprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .