Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.6 CrAccepted-AOC | ₹1.6 Cr | 1 | Accepted-AOC 1 |
| 2 | 2₹1.6 Cr+₹32,188.30 (0.20%)Rejected-AOC | ₹1.6 Cr+₹32,188.30 (0.20%) | 2 | Rejected-AOC 2 |
Tender Value
Refer Docs
EMD Value
₹3.2 L
Closing Date
19 Sept 2022, 5:00 pmClosed
Executive Engineer
Executive Engineer, Uttarakhand Jal Sansthan Haldwani Rural (Lalkuan) situated at Goraparao Bareilly Road Haldwani District Nainital
Construction, Testing and Commissioning of Tularampur-Dhanpur (MVS) Water Supply Scheme Haldwani Block District Nainital
2022_UKJS_48675_4
909/E-Nivida/32 Dated 24.08.2022
Open Tender
Civil Works - Water Works
Item Wise
365 days
Haldwani Rural- Lalkaun
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
Executive Engineer, UJS
₹3.2 L
Haldwani Rural- Lalkaun
6 Oct 2023
31 Aug 2022
21 Sept 2022
31 Aug 2022
19 Sept 2022
31 Aug 2022
5 Sept 2022
Rates for Construction, Testing & Commissioning of Tularampur-Dhanpur (MVS) Water Supply Scheme with OHT, Pumping Plant, Rising main, Distribution Main & Distribution Pipe Line, FHTC, Repair of Pump House, Boundary Wall, Miscellaneous & Other works etc. at Haldwani Block District Nainital.
Pump and Related E&M Items.
Supply, Installation, Testing & Commissioning on turnkey basis for fully automatic pump automation control pannel of 1000Lpm of 130 mtr. head capaciy having intelegent unit having" FIELD PROGRAMMABLE LOGIC CONTROLER based SCADA operated pump motor startRun Control Protactagainst faults automatically operated controle and management system" for supervisory control and data acquasition system at pumping water supply schemes & two year freeof cost AMC for warranty period of following dutiesas per specifications sheet enclosed &suaitable for integrationsin the existing system including cartage from works of manufactures up to site of work Capacity of 1000Lpm of 130 mtr. head.
Supply and fixing of 400 Amp TPN main switch 3 phase, 415 volt, 50 H havells make heavy duty double break main switch with HRC fuse making connection at this testing complete work etc at dewalatallatubewell.
Supply and fixing of 35 KVAR heavy duty power capacitor L & T make 440 volt 50 H box type.
Supply installation testing and commissioning of three phase digital rolling contract survo voltage stabilizer suitable for unbalnce voltage and unbalanced load including fixing of proper size copper lugs on input and output cables on both ends at different sites on turnkey basis including 5 year cost free maintenance Input voltage 330-460 volts (Phase to phase) 100 KVA
Main piping and valves as per specification.
Supply and fixing of suitable 16 mm thick MS Flange for column pipe both end with fixing trangle support and cutting of groove for cable all complete with labour & T&P
Supply of Heavy Duty Suitable 16mm thick MS Flanged, Cutting of Edges/Thread of column pipe for fixing of Heavy Duty suitable flange for two end on column pipe, fixing of 4 Nos. triangle corner each side on column pipe for supporting of flange, cutting of Grooves in flanges for submersible cable (2 Nos. on each side). Drilling of 8 hole on each side of flange for jointing of column pipe including supply of all labour T&P required for the proper completion of work. Supply of 150mm dia as per directed by Engineer-In-Charge.
Supply of 150mm dia size column pipe clamps as per directed by Engineer-In-Charge.
Supply of 3 Core flat submersible cable KSB make Conti Cable 3/35.0 sq.mm suitable for Submersible as per directed by Engineer-In-Charge.
Supply of Tool Kits as per directed by Engineer-In-Charge.
Supply of Lifting tackle 10 tonne capacity Chain pulley as per directed by Engineer-In-Charge.
Installatuion as for as per directed by Engineer-In-Charge.
INJECTING DOSER:
Supply & Installation of Electronically controlled,Electricallyactuated,diaphragmoperated,chemical metering pump,wall mounting suitable for deliveing up to 6 Litres of chemical solution/sodium hypochlorite solution per hour under maximum delivery pressure up to 10.0KG/cm2 and suction lift not less than 1.5 meter with accessories.
Pump House A: -Repari Work :-
Providing and laying in position cement concrete of 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) grade - All work up to plinth level
Providing and laying in position 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) grade of Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. - for Thermo-Mechanically Treated bars
Centering and shuttering including strutting,ropping etc. and removal of form Slab, Chhajja
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand).
12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand).
Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) grade. - Apron
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. - New work (Two or more coat )
Finishing walls with exterior paint of required shade - New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. - Using M.S. angels 40x40x6 mm for diagonal braces.
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. for window, ventilator and similar works. use angle, square bar, etc
Providing & fixing glass panes with putty and glazing clips in steel windows & ventilator all complete. With 4.0 mm thick glass panes.
Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. - ISMB 300 x 140
Painting Steel work(doors, windows, etc.) with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture.
B:- Water supply & sanitary installations :-
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. for external works. 25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. for internal works. 20 mm dia nominal bore
Providing and fixing brass bib cock of approved quality. 15 mm nominal bore
20 mm nominal bore
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet. 150 mm diameter
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank
Excavation of earth below G.L. by manually or by mechanical means for laying of Sewers, Manholes, Gully pits, Chambers etc. in soil including extra excavation below inverts, trimming and dressing of sides, leveling and back filling of trenches by excavated earth in 20cm layers, watering and ramming the same including removal of surplus earth or other dismantled material upto a distance of 50 meters from the centre of trenches and cleaning of sites properly after completion of the work. Excavation by mechanical means shall be restricted upto 90 cm above invert levels at every point of excavation. Excavation from invert levels to 90cm above shall be done manually only. Soil mixed with moorum, shingle &kankar etc. using of any specials, T&P, if required. (95% of relevant quantity) 0.00m to 1.50m B.G.L.
Supply & Laying-Jointing of following dia R.C.C. S&S pipes with rubber gaskets to the site of work, lowering the same into trenches below ground level true to alignment, making the joints with rubber gaskets and with necessary spun yarn soaked in bitumen jointing with 1:2 cement mortar in coarse sand including cost of all jointing materials and testing etc. complete but excluding excavation and back filling of trenches upto ground level. (Class - NP3) 150mm dia 0.00m to 1.50m B.G.L.
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)
BOUNDARY WALL
Earth work in excavation by manual means in foundation trenches or drain (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of side and ramming of bottoms, lift upto 1.5 m including getting out the excavation soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Ordinary rock
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size)
Ist class Brick work 1:6 in foundation including necessary cutting and moulding as required and thickness of wall one brick. including supply of all materials, labour and T&P etc. required for proper completion of the work
Ist class Brick work 1:6 in super structure including necessary cutting and moulding as required and thickness of wall one brick. including supply of all materials, labour and T&P etc. required for proper completion of the work
PC plaster with cement mortar in 1:6 (one cement and six local sand) minimum thickness 12 mm including raking of joint upto 1.27 cm 10 1/2 '' depth and also including supply of all materials labour T&P and require for proper completion of the work
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Centering shuttering including struttings, propping etc. and removal of form work Lean Concrete
M.S. IRON GATE WITH PILLARS
Earth work in excavation by manual means in foundation trenches or drain (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of side and ramming of bottoms, lift upto 1.5 m including getting out the excavation soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Ordinary rock
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size)
Ist class Brick work 1:6 in foundation including necessary cutting and moulding as required and thickness of wall one brick. including supply of all materials, labour and T&P etc. required for proper completion of the work
Ist class Brick work 1:6 in super structure including necessary cutting and moulding as required and thickness of wall one brick. including supply of all materials, labour and T&P etc. required for proper completion of the work
PC plaster with cement mortar in 1:6 (one cement and six local sand) minimum thickness 12 mm including raking of joint upto 1.27 cm 10 1/2 '' depth and also including supply of all materials labour T&P and require for proper completion of the work
M.S. work in heavy size such as build up gates doors, frames etc wrought to required from including drilling of holes revanting of welding share necessary and also including supply of steel bolts, nuts etc and their fixing required for proper completion of work
Acrylic smooth exterior paints three coats on pillars
Painting two coats of approved paint over one base (priming coat) on new surface of Gate and Pillars
Centering shuttering including struttings, propping etc. and removal of form work For CC work
EARTHWORK FOR CUTTING, FILLING AND DISPOSAL OF SURPLUS EARTH (RISING MAIN)
Excavation in Pipe Line TrenchesExcavation in soil mixed with single bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches.
PROVIDING AND LAYING OF PIPES (RISING MAIN)
Proving of all materials, carting from site store to site of work, lowering into trenches with true to alignment, Laying of MSREW Pipes grade Yst 210, confirming to IS: 1978-1982, jointing by electric welding process with proper grade of electrodes suitable for jointing of water supply pipe lines (Ador, L&T or equivalent electrodes) by cutting of pipes and making required bends by welding, completion of works with testing of pipe line etc complete. MSERW PIPE - 5.6mm thick 150 mm dia
Valves & Valve Chambers (Rising Main / Gravity Main)
Supplying, Installation, testing and commissioning of Non Return Valves Including Carting the same upto the site of workas per engineering norms anywhere in uttarakhand. C.I. D/F Non Return Valves Pressure PN 10 150 mm dia
Supplying and Installation of Air Valves as per engineering norms of approved quality with bolts, nuts, rubber insertions etc. complete anywhere in uttarakhand C.I. Air Valve Double Acting 65 mm dia
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Making connection with the existing M.S. Galvanised mains of upto 25mm nominal dia, including cutting and threading of pipe, bailing out water, fixing, if required, specials and testing etc. complete, but excluding cost of insertion pipes and specials besides boring out (and also subsequent back fill) existing main. 100mm-150 mm
Over Head Tank / GLSR
Supply of all materials, labour, T&P etc and construction of R.C.C. O.H.T. of 40 KL and 18m staging height including cost of all material, labour, shuttering, scaffolding, T&P completed for following capacity (in KL) with 1.00m wide R.C.C. stair case from G.L. to balcony and from balcony to top dome 1m x1m R.C.C. landing at suitable locations and railed with 3 rows of 20mm dia G.I. (M) pipe on 65x65x5 mm angle iron posts fixed with ladder, from top to the floor inside of the tank, M.S. M.H. cover with locking arrangement, lightning conductor as per electricity rules, water level indicator, supply and fixing of outlet, inlet, over flow and washout pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover, ventilator column etc. complete with approved water proofing (apex.)/enamel paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials, assuming bearing capacity as 8MT/SQM and staging 18.00 meter.
Submission of Soil testing, Detailed Design and drawing from any recognized University such as I.I.T etc or Govt accredited firm/Lab as per direction of Engineer in -charge. R.C.C. as per approved design including fixing various pipes and ventilator at top and fixing of M.S. sheet of 10mm gauge manhole cover of 60X60cm size with frame and locking arrangement and railing including supply of all material. Two column R.C.C. stair case with 1.0 mtr minimum clear width attached with tank body as an access to balcony and top dome of tank from ground level as per design and drawing with 1.25m high railling and gate with cabin as per specification including supply of all materials. Supply of fixing of M.S. Ladder form inside the tank body from room to the bottomdome of the tank in the slope of 3:1 (3vertical:1 horizontal) with railing as specified. Railing on staircase & its landings, all around balcony & top dome for access up to ventilator as specifications including supply of all material, Railing shall be provided in three rows of G.I. pipes (medium Quality) Supply and fixing of digital water level indicator along with all necessory equipment such as invertor a per specifications and fixing of lightening conductor and earth plate etc. as per specifications. Testing of tank of water tightness as per specifications enclosed including supply of water. Supply of all materials and construction of 80mm thick R.C.C. floor, apron and 15cm diasemi circular drain around apron in a slope towards wash out chamber. Three coats of approved quality and shade of Apex Asian Paint for Painting of as per direction of Engineer in charge over concrete work including supply of all materials etc. Three coats of anti corrosive/aluminum/black Japan paint of approved quality on all iron work including supply of all material, laborand T&P etc. Supplying, carting and fixing of following sizes MSERW/D.I D/F pipes with required specials such as reducers, duck foot bend, (bell mouth etc. in inlet of tank) rubber insertion sheet, nut bolts, washer etc. complete as per specifications: a- 150 mm dia in inlet b- 200mm dia in outlet c- 200 mm dia in overflow d- 100 mm dia in wash out Supplying, carting and fixing of following sizes D.I. D/F sluice valves as per relevent latest I.S. Specifications including supply of all jointing and other materials such as rubber insertion sheet, nut bolts, washer etc. complete as per specifications: a- 150 mm da in inlet b- 200mm dia in outlet c- 200 mm dia in overflow Supply of all materials labour T&P and construct brick masonry sluice valve chambers including R.C.C. cover as per deptt. Type design at inlet, outlet and washout pipes. The R.C.C. cover shall be casted in M.S. Channel section with handles on both sides.(Sluice valve chamber for over flow & wash out may be combined). The words JalJeevan Mission, year of construction, capicity of O.H.T. and slogan approved by Engineer in charge shall be painted prominently in letter not less than 30cm. In height. Maintenance of 12 months including supply of all materials etc complete. Maintenance period shall be counted from date of completion.
Repair of Existing OHT (45 KL) Cleaner for Clean & Condition of OHT
High Voltage epoxy to Arrest Leakages
Repairing of existing OHT 15 % Extra labour Charge
Dismantling of Road
Dismantling of flexible pavements and disposal ofdismantledmaterialsuptoalead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202
For Pipe Laying
Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately
Restoration of Road For Pipe Laying
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
EARTHWORK FOR CUTTING, FILLING AND DISPOSAL OF SURPLUS EARTH (DISTRIBUTION MAIN)
Excavation in soil mixed with shingle bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling,waterring and ramming of Excavated earth in the trenches.
PROVIDING AND LAYING OF PIPES (DISTRIBUTION MAIN)
Providing of all materials, Carting from site store of work , Laying and Jointing of G.I Pipes confirming to IS: 1239 (PART-1) including supply of all jointing materials like specials white lead,hemp and oil etc in trenches with its cutting, threading and testing of pipe line etc complete. G.I. PIPE CONFORMING TO IS : 1239 (PART-1) -2004 Medium Duty (Class 'B') 50 mm dia GI Pipe
65 mm dia GI Pipe
80 mm dia GI Pipe
100 mm dia GI Pipe
Replacement and reparing of exsiting pipeline and Valve.
Dismantling of following dia screwed and socketed G.I. Pipes, specials and fittings including taking out of dismantled G.I. pipes and specials from trenches and stacking them properly within 50m but excluding the cost of earth work (Note :- This item shall be paid with the condition that the recovered pipe from dismantling is reusable.) Dismantling of G.I. pipes. 50 mm dia GI Pipe
80 mm dia GI Pipe
100 mm dia GI Pipe
Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc. etc.) in trenches with it's cutting, threading and testing of pipeline etc. complete. 50 mm dia GI Pipe
80 mm dia GI Pipe
100 mm dia GI Pipe
Welding Works
Making connection with the existing M.S. Galvanised mains of upto 25mm nominal dia, including cutting and threading of pipe, bailing out water, fixing, if required, specials and testing etc. complete, but excluding cost of insertion pipes and specials besides boring out (and also subsequent back fill) existing main. 50mm-80 mm
Valves & Valve Chambers (DISTRIBUTION MAIN)
65 mm dia
80 mm dia
100 mm dia
Supplying Installation testing and commissioning of Non Return Valves Including the same upto the site of workas per engineering norms anywhere in Uttarakhand.
Supplying and Installation of Air Valves as per engineering norms of approved quality with bolts, nuts, rubber insertions etc. complete anywhere in uttarakhand C.I. Air Valve Double Acting 50 mm dia
Supplying and Fixing of Fire Hydrant Valve IS 5290 (Flanged) Including carting the same upto site of work and fixing the same and water supply line Including the cost of valves,specials,labour and T&P Complete in all respect. 80 mm diameter
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. For in line pressure Transmeter in distribution network.
Flow Meter
Providing and fixing Woltman type Bulk water meter Inline type, flange end with Integral mounted display and all necessary fittings etc complete At Distribution For DMA 100 mm
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. For in line pressure Transmeter in distribution network.
Shifting of FHTC's from old PVC line to new GI line. FHTC (Functional Household Tap Connection)
Excavation in soil mixed with single bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches. 15 mm dia GI Pipe
Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc complete. 15 mm dia GI Pipe
Making ferrule connection in the existing main of G.I, A.C, PVC or any type of pressure mains with saddle piece, service connections, fittings and fixing of G.M. ferrule including tapping the main, but excluding the cost of earth work and cost of all materials. 19.01 Ferrule Connection (Labour cost only)/Connection Ferrule Connection (Labour cost only) for shifting of connection.
Cost of Material for ferruling in FHTC per connection as Lump Sum
M/S BAJPAI CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .