| Sl No | Description | Qty | Unit | SHUKLA ENTERPRISE L1 | PSM ENGINEERING SERVICES L4 | SHYAM JITENDRA MODHA L3 | MITRA MARINE WORKS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | L-056:- MF/HF (Make- I-COM, Model-IC-M802) unit display is flickering and appears blurry. The characters are not visible clearly, affecting normal operation. Suspect display board/PCB defective. Display board to be inspected and repaired/renewed as per sample. Post rectification, system to be tested & proved for satisfactory operation.display board/PCB defective. Display board to be inspected and repaired/renewed as per sample. Post rectification, system to be tested & proved for satisfactory operation.(Make-Furuno Electric Co. Ltd, Model: FM 4000) display not showing, however the system is working satisfactorily. Display to be rectified and proved for satisfactory operation. | 1 | Nos | 2,08,000 ₹2.1 L | 2,21,000 ₹2.2 L | 2,14,000 ₹2.1 L | 2,06,500 ₹2.1 L |
| 2.00 | L-059:- 02 in nos sensor of Flood alarm system not working properly. During routine testing, alarm buzzar & visual indication not activating. Suspect sensor malfunctioning or cable from sensor to control unit defective. DI/DR to be undertaken and cable to be renewed (Length- 30 mtrs). | 1 | Nos | 2,36,000 ₹2.4 L | 99,000 ₹99,000 | 95,500 ₹95,500 | 2,34,500 ₹2.3 L |
| 3.00 | L-057:- Emergency light not working during main Power supply failure. Suspect automatic changeover/control system failure. DI to be carried out and repaired/renewed the defective unit. Post defect rectification system to be proved for satisfactory performance. | 1 | Nos | 92,000 ₹92,000 | 2,56,500 ₹2.6 L | 2,52,000 ₹2.5 L | 90,500 ₹90,500 |
| 4.00 | L-064: The Ship is fitted with DGPS (Make: Koden, Model: KGP-920). Erratic reading occurred in DGPS display. Suspect Co-axial cable of antenna short circuited & DGPS software malfunctioning. DI/DR of system to be carried out. All inway job includes laying of co-axial cable from bridge top to wheel house (length approx.. 15 Mtrs.) Defective components to be repaired/ renewed and system to be proved for satisfactory operation. | 1 | Nos | 1,80,500 ₹1.8 L | 1,99,000 ₹2.0 L | 1,91,000 ₹1.9 L | 1,84,500 ₹1.8 L |
| 5.00 | L-039: Ship's galley hot plate (Make: M/s Kantilal & Chunilal, Capacity: 3 PH, 415V, 5.1 KW) not working view rotary switch defective and control wiring short circuited. Same to be renewed as per sample. All inway job includes renewal of rotary switches 02 Nos, cable length 20 Mtrs approx., Heating elements 02Nos. Defect to be rectified and proved for satisfactory operation of the Hot plate. | 1 | Nos | 52,500 ₹52,500 | 60,000 ₹60,000 | 55,600 ₹55,600 | 56,500 ₹56,500 |
Tender Value
Refer Docs
Closing Date
10 Mar 2026, 9:00 amClosed
District Technical Officer
The Commander, DHQ-1
Defect Rectification
2026_ICG_754559_1
344/161/44/25-26
Limited
Marine Services
AT ICGS C-161 and C-445
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
12 Mar 2026
27 Feb 2026
11 Mar 2026
27 Feb 2026
10 Mar 2026
27 Feb 2026
L-056:- MF/HF (Make- I-COM, Model-IC-M802) unit display is flickering and appears blurry. The characters are not visible clearly, affecting normal operation. Suspect display board/PCB defective. Display board to be inspected and repaired/renewed as per sample. Post rectification, system to be tested & proved for satisfactory operation.display board/PCB defective. Display board to be inspected and repaired/renewed as per sample. Post rectification, system to be tested & proved for satisfactory operation.(Make-Furuno Electric Co. Ltd, Model: FM 4000) display not showing, however the system is working satisfactorily. Display to be rectified and proved for satisfactory operation.
L-059:- 02 in nos sensor of Flood alarm system not working properly. During routine testing, alarm buzzar & visual indication not activating. Suspect sensor malfunctioning or cable from sensor to control unit defective. DI/DR to be undertaken and cable to be renewed (Length- 30 mtrs).
L-057:- Emergency light not working during main Power supply failure. Suspect automatic changeover/control system failure. DI to be carried out and repaired/renewed the defective unit. Post defect rectification system to be proved for satisfactory performance.
L-064: The Ship is fitted with DGPS (Make: Koden, Model: KGP-920). Erratic reading occurred in DGPS display. Suspect Co-axial cable of antenna short circuited & DGPS software malfunctioning. DI/DR of system to be carried out. All inway job includes laying of co-axial cable from bridge top to wheel house (length approx.. 15 Mtrs.) Defective components to be repaired/ renewed and system to be proved for satisfactory operation.
L-039: Ship's galley hot plate (Make: M/s Kantilal & Chunilal, Capacity: 3 PH, 415V, 5.1 KW) not working view rotary switch defective and control wiring short circuited. Same to be renewed as per sample. All inway job includes renewal of rotary switches 02 Nos, cable length 20 Mtrs approx., Heating elements 02Nos. Defect to be rectified and proved for satisfactory operation of the Hot plate.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_845150.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
BOQ_845150.xls
BOQ • 0.28 MB
RFP.pdf
Tender Documents • 0.23 MB
Download all tender documents and submit your bid